Full-Text Articles in Tribology
Characterization Of The Fatigue Threshold Behavior Of Uhmwpe, Bethany B. Smith, Anurag Roy, Robert O. Ritchie, Lisa A. Pruitt
Characterization Of The Fatigue Threshold Behavior Of Uhmwpe, Bethany B. Smith, Anurag Roy, Robert O. Ritchie, Lisa A. Pruitt
Faculty Journal Articles
Ultra-high-molecular-weight-polyethylene (UHMWPE) has been the material of choice for bearings in total joint replacements (TJRs) for decades as a result of its excellent wear resistance, chemical inertness, energetic toughness, low friction, and biocompatibility. Utilization of this polymer in orthopedic devices requires oxidation, wear, and fatigue resistance. Balancing these important properties by tailoring processing techniques and modulating microstructural features has been an ongoing endeavor in the field. Research into the clinical applications of UHMWPE has primarily focused on the challenges of wear and oxidation while studies into the realm of fatigue have been more limited. Literature gaps exist in fully understanding …
Finite Element Analysis Of The Bearing Component Of Total Ankle Replacement Implants During The Stance Phase Of Gait, Timothy S. Jain
Finite Element Analysis Of The Bearing Component Of Total Ankle Replacement Implants During The Stance Phase Of Gait, Timothy S. Jain
Master's Theses
Total ankle replacement (TAR) implants are an effective option to restore the range of motion of the ankle joint for arthritic patients. An effective tool for analyzing these implants’ mechanical performance and longevity in-silico is finite element analysis (FEA). ABAQUS FEA was used to statically analyze the von Mises stress and contact pressure on the articulating surface of the bearing component in two newly installed fixed-bearing total ankle replacement implants (the Wright Medical INBONE II and the Exactech Vantage). This bearing component rotates on the talar component to induce primary ankle joint motion of plantarflexion and dorsiflexion. The stress response …
Surface Laser Texturing Of Cocrmo Alloys, Gabriel Dharwadker
Surface Laser Texturing Of Cocrmo Alloys, Gabriel Dharwadker
Biomedical Engineering Undergraduate Honors Theses
Artificial orthopedic implants such as hip joints suffer from excessive wear due to excess friction between the polyethylene and cobalt-chromium-molybdenum surfaces of the device. This increase in friction causes a fraction of them to give out within ten years. Therefore, to minimize the probability of this happening, recent research has been conducted regarding laser surface texturing of the cobalt-chromium-molybdenum alloy components of artificial joints. These surface textures serve to mimic the native lubrication mechanisms of cartilage in natural joints, which, in a natural joint, lowers the friction. However, the production of these laser surface textures is still a field of …