Open Access. Powered by Scholars. Published by Universities.®

Manufacturing Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 9 of 9

Full-Text Articles in Manufacturing

A Collagen‐Glycosaminoglycan‐Fibrin Scaffold For Heart Valve Tissue Engineering Applications, Claire Brougham, Stefan Jockenhoevel, Thomas Flanagan, Fergal O'Brien Sep 2014

A Collagen‐Glycosaminoglycan‐Fibrin Scaffold For Heart Valve Tissue Engineering Applications, Claire Brougham, Stefan Jockenhoevel, Thomas Flanagan, Fergal O'Brien

Conference Papers

The field of heart valve biology and tissue engineering a heart valve continue to expand. The presentatio ns at this meeting reflect the advances made in both areas due to the multi-disciplinary approach taken by many laboratories.


Intelligibility Of Electrolarynx Speech Using A Novel Hands-Free Actuator, Brian Madden, Mark Nolan, Ted Burke, James Condron, Eugene Coyle Jan 2011

Intelligibility Of Electrolarynx Speech Using A Novel Hands-Free Actuator, Brian Madden, Mark Nolan, Ted Burke, James Condron, Eugene Coyle

Conference Papers

During voiced speech, the larynx provides quasi-periodic acoustic excitation of the vocal tract. In most electrolarynxes, mechanical vibrations are produced by a linear electromechanical actuator, the armature of which percusses against a metal or plastic plate at a frequency within the range of glottal excitation. In this paper, the intelligibility of speech produced using a novel hands-free actuator is compared to speech produced using a conventional electrolarynx. Two able-bodied speakers (one male, one female) performed a closed response test containing 28 monosyllabic words, once using a conventional electrolarynx and a second time using the novel design. The resulting audio recordings …


Therapeutic Ultrasound Angioplasty: The Risk Of Arterial Perforation. An In Vitro Study, Mark Wylie, Garrett Mcguinness, Graham Gavin Jan 2009

Therapeutic Ultrasound Angioplasty: The Risk Of Arterial Perforation. An In Vitro Study, Mark Wylie, Garrett Mcguinness, Graham Gavin

Conference Papers

The use of therapeutic ultrasound delivered via small diameter wire waveguides may represent an emerging minimally invasive approach in the treatment of chronic total occlusions (CTOs), calcified and fibrous plaques. The distal-tip mechanical vibrations (typically 0-210 μm peak-to-peak) have been reported to debulk rigid calcified and fibrous tissues while healthy elastic arterial tissue remains largely unaffected. The risk of arterial (healthy tissue) perforation with energized waveguides is not fully understood. An ultrasonic apparatus capable of delivering a range of wire waveguide distal-tip displacements, up to 80 μm peak-to-peak (p-p), at an operational frequency of 22.5 KHz (+/- 6%) has been …


Ultrasonic Angioplasty: Assessing The Risk Of Arterial Perforation, Mark Wylie, Garrett Mcguinness, Graham Gavin Jan 2009

Ultrasonic Angioplasty: Assessing The Risk Of Arterial Perforation, Mark Wylie, Garrett Mcguinness, Graham Gavin

Conference Papers

Atherosclerosis is a cardiovascular disease that effects large and medium muscular arteries (such as coronary and iliac) and also large elastic arteries (such as aorta) [1]. It causes thickening of the arterial wall and over time can result in a completely blocked artery or chronic total occlusion (CTO). While the majority of atherosclerotic lesions can be attempted by typical Percutaneous Transluminal Coronary Angioplasty (PTCA) such as balloon and stent implantation, calcified CTOs are often problematic as they do not lend themselves to be accessed by the guidewire which is required to implant the balloon and stent. Excessive guidewire pushing force …


Force Measurement And Evaluation For Surgical Cutting Applications: Development Of An Effective Characterisation Testbed, Dean Callaghan Mar 2008

Force Measurement And Evaluation For Surgical Cutting Applications: Development Of An Effective Characterisation Testbed, Dean Callaghan

Conference Papers

Sensorized instruments that cater for accurate measurement of the interaction forces (between biological tissue and instrument end-effector) during surgical procedures offer surgeons a greater sense of immersion during minimally invasive robotic surgery (MIRS). There is much ongoing research into force measurement/evaluation involving surgical graspers. However, comparatively little corresponding effort has been expended in the measurement and subsequent evaluation of forces between scissor blades and tissue. This paper presents the design and development of a force/strain measurement test apparatus, which will ultimately serve as an effective sensor characterisation and evaluation platform. Data acquired from the testing platform can be used to …


A Numerical Acoustic Fluid-Structure Simulation Of Therapeutic Ultrasound Angioplasty, Graham Gavin, Finbar Dolan, M.S J. Hashmi, Garrett Mcguinness Jan 2006

A Numerical Acoustic Fluid-Structure Simulation Of Therapeutic Ultrasound Angioplasty, Graham Gavin, Finbar Dolan, M.S J. Hashmi, Garrett Mcguinness

Conference Papers

INTRODUCTION Therapeutic ultrasound angioplasty is the delivery of high amplitude ultrasonic displacements to the distal-tip of small diameter wire waveguides with the goal of disrupting atherosclerotic plaques. This is a minimally invasive procedure that may have potential' in the treatment of complicated chronic total occlusions. The disruption of plaque is due to direct contact ablation and also cavitation, pressure waves and acoustic streaming in the fluid surrounding the vibrating waveguide distal-tip [1]. Cavitation appears to play a major role and some authors have suggested that plaque ablation is only evident above the cavitation threshold [2]. Makin and Everbach [3] performed …


A Numerical Acoustic Fluid-Structure Model Of A Therapeutic Ultrasound Angioplasty Device, Graham Gavin, M.S. J. Hashmi, Finbar Dolan, Garrett Mcguinness Jan 2006

A Numerical Acoustic Fluid-Structure Model Of A Therapeutic Ultrasound Angioplasty Device, Graham Gavin, M.S. J. Hashmi, Finbar Dolan, Garrett Mcguinness

Conference Papers

Ultrasonic angioplasty involves the use of ultrasonic vibrations delivered to the distal-tip of small diameter wire waveguides and is an emerging technology the may have potential use in the treatment of complicated atherosclerotic plaques during cardiovascular surgery. Complicated plaques, including chronic total occlusions and calcified lesions, seriously reduce success rates during standard intervention involving guidewire access, followed by balloon dilation or stent delivery. The large amplitude (0-150 μm) wire waveguide distal-tip displacements in the low-frequency ultrasonic (18-45 kHz) range have been shown to disrupt plaque material by direct contact ablation and cavitation, acoustic streaming and pressure wave components in adjacent …


Development And Performance Characteristics Of An Ultrasound Angioplasty Device, Graham Gavin, Garrett Mcguinness, Finbar Dolan, M.S. J. Hashmi Jan 2005

Development And Performance Characteristics Of An Ultrasound Angioplasty Device, Graham Gavin, Garrett Mcguinness, Finbar Dolan, M.S. J. Hashmi

Conference Papers

INTRODUCTION The effect of atherosclerosis is well documented and many procedures such as balloon angioplasty and stentimplantation have been developed to reopen occluded arteries. However, there are considerable differences in the material properties of various atherosclerotic lesions as they develop. Many authors have suggested that rigid calcified plaques may require specific procedures that target this rigid material through de-bulking or complete removal (Salunke et al, 1997). Ultrasound angioplasty is the delivery of high power low frequency ultrasound via a wire waveguide to the lesion location. This results in distal tip wire displacements of up to 100um peak-to-peak (p-p) at frequencies …


Pressure Distribution Around Spherical Distal Ball-Tip In Ultrasound Angioplasty, Graham Gavin, Garrett B. Mcguinness, Finbar Dolan, M.S. J. Hashmi Jul 2004

Pressure Distribution Around Spherical Distal Ball-Tip In Ultrasound Angioplasty, Graham Gavin, Garrett B. Mcguinness, Finbar Dolan, M.S. J. Hashmi

Conference Papers

INTRODUCTION Ultrasound Angioplasty has been shown to be effective in the removal and re-canalising of blockages in arteries (Siegel RJ, 1993). By delivering therapeutic ultrasound to the blockage, via a wire waveguide to a ball-tip, the lesion or thrombus is affected by pressure waves, micro streaming, cavitation and direct contact with the oscillating ball-tip. Most work to date has concentrated on a spherical ball-tip geometry at the distal end of the wire waveguide (Steffen, 1994 and Rosenschein, 1996). Tip displacements usually lie between 10 - 100m (peak-to peak) and ball tip diameters between 1 - 2mm (Atar, 1999 and Yock, …