Articles 31 - 35 of 35

Full-Text Articles in Manufacturing

A Numerical Acoustic Fluid-Structure Model Of A Therapeutic Ultrasound Angioplasty Device, Graham Gavin, M.S. J. Hashmi, Finbar Dolan, Garrett Mcguinness Jan 2006

A Numerical Acoustic Fluid-Structure Model Of A Therapeutic Ultrasound Angioplasty Device, Graham Gavin, M.S. J. Hashmi, Finbar Dolan, Garrett Mcguinness

Conference Papers

Ultrasonic angioplasty involves the use of ultrasonic vibrations delivered to the distal-tip of small diameter wire waveguides and is an emerging technology the may have potential use in the treatment of complicated atherosclerotic plaques during cardiovascular surgery. Complicated plaques, including chronic total occlusions and calcified lesions, seriously reduce success rates during standard intervention involving guidewire access, followed by balloon dilation or stent delivery. The large amplitude (0-150 μm) wire waveguide distal-tip displacements in the low-frequency ultrasonic (18-45 kHz) range have been shown to disrupt plaque material by direct contact ablation and cavitation, acoustic streaming and pressure wave components in adjacent …


Development And Performance Characteristics Of An Ultrasound Angioplasty Device, Graham Gavin, Garrett Mcguinness, Finbar Dolan, M.S. J. Hashmi Jan 2005

Development And Performance Characteristics Of An Ultrasound Angioplasty Device, Graham Gavin, Garrett Mcguinness, Finbar Dolan, M.S. J. Hashmi

Conference Papers

INTRODUCTION The effect of atherosclerosis is well documented and many procedures such as balloon angioplasty and stentimplantation have been developed to reopen occluded arteries. However, there are considerable differences in the material properties of various atherosclerotic lesions as they develop. Many authors have suggested that rigid calcified plaques may require specific procedures that target this rigid material through de-bulking or complete removal (Salunke et al, 1997). Ultrasound angioplasty is the delivery of high power low frequency ultrasound via a wire waveguide to the lesion location. This results in distal tip wire displacements of up to 100um peak-to-peak (p-p) at frequencies …


An Acoustic Fluid-Structure Simulation Of A Therapeutic Ultrasound Wire Waveguide Apparatus, Graham Gavin, M. Hashmi, Finbar Dolan, Garret Mcguinness Jan 2005

An Acoustic Fluid-Structure Simulation Of A Therapeutic Ultrasound Wire Waveguide Apparatus, Graham Gavin, M. Hashmi, Finbar Dolan, Garret Mcguinness

Conference Papers

The use of high-power low-frequency ultrasound transmitted down small diameter wire waveguides is an emerging technology that may have potential in the treatment of complicated atherosclerotic plaques in cardiovascular surgery. This form of energy delivery results in vibrating the distal-tip of the wire waveguide disrupting material by means of direct contact ablation and also cavitation, pressure waves and acoustic streaming in the surrounding fluid. This work describes a numerical acoustic fluid-structure model of the ultrasound wire waveguide and blood surrounding the distal tip. The structural analysis of the model predicts the natural frequencies of the waveguide and shows the extent …


Pressure Distribution Around Spherical Distal Ball-Tip In Ultrasound Angioplasty, Graham Gavin, Garrett B. Mcguinness, Finbar Dolan, M.S. J. Hashmi Jul 2004

Pressure Distribution Around Spherical Distal Ball-Tip In Ultrasound Angioplasty, Graham Gavin, Garrett B. Mcguinness, Finbar Dolan, M.S. J. Hashmi

Conference Papers

INTRODUCTION Ultrasound Angioplasty has been shown to be effective in the removal and re-canalising of blockages in arteries (Siegel RJ, 1993). By delivering therapeutic ultrasound to the blockage, via a wire waveguide to a ball-tip, the lesion or thrombus is affected by pressure waves, micro streaming, cavitation and direct contact with the oscillating ball-tip. Most work to date has concentrated on a spherical ball-tip geometry at the distal end of the wire waveguide (Steffen, 1994 and Rosenschein, 1996). Tip displacements usually lie between 10 - 100m (peak-to peak) and ball tip diameters between 1 - 2mm (Atar, 1999 and Yock, …


Knowledge-Based System For Casting Process Selection, Ahmet Er, Edward Sweeney, Voya Kondic Jan 1996

Knowledge-Based System For Casting Process Selection, Ahmet Er, Edward Sweeney, Voya Kondic

Articles

Design of casting entails the knowledge of various interacting factors that are unique to casting process, and, quite often, product designers do not have the required foundry-specific knowledge. Casting designers normally have to liaise with casting experts in order to ensure the product designed is castable and the optimum casting method is selected. This two-way communication results in long design lead times, and lack of it can easily lead to incorrect casting design. A computer-based system at the discretion of a design engineer can, however, alleviate this problem and enhance the prospect of casting design for manufacture. This paper proposes …