Open Access. Powered by Scholars. Published by Universities.®

Energy Systems Commons™

Open Access. Powered by Scholars. Published by Universities.®

University of Central Florida

Discipline
Keyword
Publication Year
Publication
Publication Type

Articles 271 - 300 of 531

Full-Text Articles in Energy Systems

Cooling Performance Assessment Of Building America Homes, Florida Solar Energy Center, Dave Chasar Jul 2006

Cooling Performance Assessment Of Building America Homes, Florida Solar Energy Center, Dave Chasar

FSEC Energy Research Center®

Long-term monitoring of building energy use and environmental conditions has been a strong component of FSEC research since the 1980s. Fully-automated data collection, verification, archiving and management ensure accurate logging of large amounts of data simultaneously from numerous field sites prior to being made available for analysis and display via the internet. Homes are typically monitored using 15 to 50 channels of data to measure indoor and outdoor environmental conditions and energy use of heating, cooling, water heating, whole house, and other points (e.g. Solar PV or Solar DHW) if needed.

Energy performance in many Building America homes has been …


Energy Performance Aspects Of A Florida Green Roof, Florida Solar Energy Center, Jeffrey Sonne Jul 2006

Energy Performance Aspects Of A Florida Green Roof, Florida Solar Energy Center, Jeffrey Sonne

FSEC Energy Research Center®

Previous green roof studies have found that planted roofs significantly reduce roof temperatures and roof heat flux, and simulations indicate cooling load reductions of up to 25%. This monitored study evaluates summer and winter energy performance aspects of a green roof on a central Florida university building addition that was completed in 2005.

Analysis of 2005 summer data indicates significantly lower peak roof surface temperatures for the green roof compared with the conventional roof and a significant shift in when the peak temperature occurs compared to the conventional roof. Summer roof heat flux estimates show the green roof to have …


Measured Crawlspace Conditions In A Hud-Code Home, Florida Solar Energy Center, David Beal Jul 2006

Measured Crawlspace Conditions In A Hud-Code Home, Florida Solar Energy Center, David Beal

FSEC Energy Research Center®

The Florida Solar Energy Center conducted research utilizing two unconditioned, old, singlewide side-by-side manufactured homes, one with a ground cover and one with exposed dirt under it. Three different skirting options were tested, open or no skirting, perforated skirting, and solid skirting.

Ambient and crawlspace dewpoints were recorded. The data is summarized in the table below. The skirting configurations tested are in Column 1, Column 2 lists the average ambient dewpoint, 3 the ground cover crawlspace, 4 the exposed dirt crawlspace dewpoint.

Successfully sealing HUD code home crawlspaces is the last piece of the puzzle of floor failures plaguing homes …


School Conditions Will Continue To Earn Failing Grades, Florida Solar Energy Center, Jeffrey Sonne Jul 2006

School Conditions Will Continue To Earn Failing Grades, Florida Solar Energy Center, Jeffrey Sonne

FSEC Energy Research Center®

This study addresses indoor air quality and general conditions problems in schools throughout the United States. Tools employed to investigate conditions include a nationwide, web-based survey, characterization of actual operating conditions in schools through field audits and diagnostic tests, and retrofits in problem schools.

Survey results found temperature to be by far the greatest comfort complaint in regular classrooms, with indoor air quality (IAQ) and then humidity being the next greatest areas of complaints. Ventilation problems were found at each of eight audited schools. These problems appear to be occurring due to a combination of factors including lack of maintenance, …


Comparison Matrix Of Florida Residential Building Energy Code And The International Energy Conservation Code (Iecc) 2006, Florida Solar Energy Center, Mangesh Basarkar Jun 2006

Comparison Matrix Of Florida Residential Building Energy Code And The International Energy Conservation Code (Iecc) 2006, Florida Solar Energy Center, Mangesh Basarkar

FSEC Energy Research Center®

This report presents a comparison of the differences between the Florida and the IECC (2006) residential energy code requirements. In addition to this summary, the documentation is divided into three sets of distinct comparisons: Comparison of Performance-based methods, Comparison of Prescriptive methods and Comparison of key provisions of the texts. In order to provide the best housing stock, with a code that is easy to implement and enforce, the final recommendation of the study was for Florida to maintain its own code, but consider incorporating some of the newer IECC measures.


Impact Of Solar Powered Disaster-Resistant Communities, Florida Solar Energy Center, William Young Apr 2006

Impact Of Solar Powered Disaster-Resistant Communities, Florida Solar Energy Center, William Young

FSEC Energy Research Center®

Natural and man made disasters can destroy lives, homes, businesses, the economy and the environment. Disasters can happen with little or no warning, leaving hundreds or even thousands of people without medical services, potable water, sanitation, communications and electrical services for up to several weeks. This paper identifies the imperative for and value of creating disaster-resistant homes and communities. The use of renewables, the application of distributed generation, implementation of energy-efficient building designs and construction of disaster-resistant structures can minimize the destruction of property, cost of recovery and disruption of lives. Through enhanced construction practices and the use of solar …


Potential Of Energy Efficiency And Renewable Energy Savings To Impact Florida's Projected Energy Use In 2014, Florida Solar Energy Center, Philip W. Fairey Feb 2006

Potential Of Energy Efficiency And Renewable Energy Savings To Impact Florida's Projected Energy Use In 2014, Florida Solar Energy Center, Philip W. Fairey

FSEC Energy Research Center®

Florida's 2004 electrical energy use was 233 billion kilowatt-hours. Over half (51%) of this energy use went to residential building energy. The state's current 10-year predictions for electrical energy use in 2014 show a requirement for approximately 308 billion kilowatt-hours of electricity, an increase of approximately 75 billion kilowatt-hours. This study presents an example of how Florida can radically alter its 2014 energy use projection by aggressively pursuing residential building energy efficiency improvements and aggressively increasing its use of proven renewable energy resources.


Unbalanced Return Air In Residences: Causes, Consequences, And Solutions, Florida Solar Energy Center, James Cummings Jan 2006

Unbalanced Return Air In Residences: Causes, Consequences, And Solutions, Florida Solar Energy Center, James Cummings

FSEC Energy Research Center®

Field research performed in 70 central Florida homes found that return grills are almost always located in the central zone of the house, and that individual rooms rarely have ducted return air or return transfer pathways. When interior doors were closed, the closed rooms went to +0.0249 inches of water gauge (in w.g.) (+6.2 pascals (Pa)) wrt outdoors (wrt = with respect to), and the central zone went to -0.0116 in w.g. (-2.9 Pa) wrt outdoors. Room pressures as high as +0.150 in w.g. (+37.3 Pa) and central zone pressure as low as -0.059 in w.g. (-14.7 Pa) wrt outdoors …


Unbalanced Return Air In Commercial Buildings, Florida Solar Energy Center, Charles Withers, Jr. Jan 2006

Unbalanced Return Air In Commercial Buildings, Florida Solar Energy Center, Charles Withers, Jr.

FSEC Energy Research Center®

Research in 88 central Florida commercial buildings during the last decade has found that 26% of the air distribution systems had substantially unbalanced return air. Unbalanced return air occurs when there is a restriction to air flow between the supply discharge and the return air, creating positive and negative pressure fields throughout the building. Severe consequences in commercial buildings can occur as a result of unbalanced air flows. This paper examines unbalanced return air and its consequences in three commercial buildings, and explains why balancing air flow in buildings is a critical part of maintaining a healthy and energy efficient …


Understanding The Dehumidification Performance Of Air-Conditioning Equipment At Part-Load Conditions, Florida Solar Energy Center, Don B. Shirey Iii Jan 2006

Understanding The Dehumidification Performance Of Air-Conditioning Equipment At Part-Load Conditions, Florida Solar Energy Center, Don B. Shirey Iii

FSEC Energy Research Center®

Air conditioner cooling coils typically provide both sensible cooling and moisture removal. Data from a limited number of field studies (Khattar et al. 1985; Henderson and Rengarajan 1996; Henderson 1998) have demonstrated that the moisture removal capacity of a cooling coil degrades at part-load conditions - especially when the supply fan operates continuously while the cooling coil cycles on and off. Degradation occurs because moisture that condenses on the coil surfaces during the cooling cycle evaporates back into air stream when the coil is off. This degradation affects the ability of cooling equipment to maintain proper indoor humidity levels and …


Abstract/Conclusion: Understanding The Dehumidification Performance Of Air-Conditioning Equipment At Part-Load Conditions, Florida Solar Energy Center, Don B. Shirey Iii Jan 2006

Abstract/Conclusion: Understanding The Dehumidification Performance Of Air-Conditioning Equipment At Part-Load Conditions, Florida Solar Energy Center, Don B. Shirey Iii

FSEC Energy Research Center®

Air conditioner cooling coils typically provide both sensible cooling and moisture removal. Data from a limited number of field studies (Khattar et al. 1985; Henderson and Rengarajan 1996; Henderson 1998) have demonstrated that the moisture removal capacity of a cooling coil degrades at part-load conditions, especially when the supply fan operates continuously while the cooling coil cycles on and off. Degradation occurs because moisture that condenses on the coil surfaces during the cooling cycle evaporates back into air stream when the coil is off. This degradation affects the ability of cooling equipment to maintain proper indoor humidity levels and may …


Energy Efficient Transportation For Florida, Florida Solar Energy Center, Danny Parker Nov 2005

Energy Efficient Transportation For Florida, Florida Solar Energy Center, Danny Parker

FSEC Energy Research Center®

Nearly 30% of energy used in Florida is consumed by our 13 million personal automobiles. Annual gasoline consumption in Florida is about 7.5 billion gallons. Florida also has more registered cars per capita than any other state in the U.S. - nearly one car for each person. The average Florida automobile is driven over 10,000 miles a year burning about 550 gallons of gasoline and costing its owner about $1,500 in fuel costs alone (not to mention payments, insurance, service, repairs, tires, tags, license etc.). Based on a comprehensive analysis, total automobile operating costs average over $850 per month.


Technical Support For Development Of An Attic Simulation Model For The California Energy Commission, Florida Solar Energy Center, Danny Parker Sep 2005

Technical Support For Development Of An Attic Simulation Model For The California Energy Commission, Florida Solar Energy Center, Danny Parker

FSEC Energy Research Center®

The California Energy Commission (CEC) is developing a new attic simulation model for assessing residential energy performance within its Title 24 residential compliance methodology. Within this project, we are providing technical support to assist Bruce Wilcox and CEC in development of the model based on Florida Solar Energy Center (FSEC) experience with similar models. We assisted the effort by using data from FSEC instrumented facilities to help verify the eventual simulation. We also outlined critical issues for modeling with the development of the simulation. Given the importance of attic ventilation, we are also conducting new studies of varied ventilation rates …


Showering In The Sun, Florida Solar Energy Center, James Haggard Aug 2005

Showering In The Sun, Florida Solar Energy Center, James Haggard

FSEC Energy Research Center®

For thousands of years, man has used energy from the sun to heat water. Today, the typical way of obtaining hot water for a shower is through a residential or commercial thermal system installed on a building. This type of shower is too big and heavy to use outdoors, although camping facilities and parks may have such systems for their patrons. Original outdoor showers that were developed for use in remote locations were bulky and not particularly portable. Today's solar shower is designed to be practical for camping, recreational and marine use. New products are made of plastic for lighter …


Disasters: Photovoltaics For Special Needs, Florida Solar Energy Center, William Young Aug 2005

Disasters: Photovoltaics For Special Needs, Florida Solar Energy Center, William Young

FSEC Energy Research Center®

The National Hurricane Center tracks the path of a hurricane to determine where it will make landfall. People in harm's way are informed of its approach and the need to evaluate options to prevent injury and protect lives. One of the many groups of people at high risk is those with special needs. They have health conditions that require special care. Before a disaster, these individuals live in hospitals, care facilities and homes. During and following a disaster, many would be moved, along with their supplies, equipment and a caretaker, to a special needs shelter. Others would stay with relatives …


Renewable Energy And Disaster-Resistant Buildings, Florida Solar Energy Center, William Young Aug 2005

Renewable Energy And Disaster-Resistant Buildings, Florida Solar Energy Center, William Young

FSEC Energy Research Center®

Hurricanes, floods, tornados and earthquakes create natural disasters that can destroy homes, businesses and the natural environment. Such disasters can happen with little or no warning, leaving hundreds or even thousands of people without medical services, potable water, sanitation, communications and electrical services for up to several weeks. The 2004 hurricane season ravaged the State of Florida, U.S.A., with four major hurricanes within a 6-week timeframe. Over nine million people evacuated their homes and damage to property was extensive.

One proactive strategy to minimize this type of destruction and disruption to lives is the implementation of disaster-resistant buildings that are …


Flexible Roofing Facility: 2004 Summer Test Results, Florida Solar Energy Center, Danny Parker Jul 2005

Flexible Roofing Facility: 2004 Summer Test Results, Florida Solar Energy Center, Danny Parker

FSEC Energy Research Center®

The Flexible Roof Facility (FRF) is a test facility in Cocoa, Florida designed to evaluate five roofing systems at a time against a control roof with black shingles and vented attic (Figure E-1). Since 1989 the testing has evaluated how roofing systems impact summer residential cooling energy use and peak demand. In the summer of 2004, the following roofing systems were tested. Materials tested were: Galvalume® unfinished (unpainted) 5-vee metal with vented attic (3rd year of exposure), galvanized unfinished 5-vee metal with vented attic (3rd year of exposure, black shingles with standard attic ventilation (Control Test Cell), white standing seam …


Development Of High Efficiency Air Conditioner Condenser Fans, Florida Solar Energy Center, Danny Parker Jun 2005

Development Of High Efficiency Air Conditioner Condenser Fans, Florida Solar Energy Center, Danny Parker

FSEC Energy Research Center®

With sponsorship from the U.S. Department of Energy, a research project has designed, fabricated and tested improvements to an air conditioner outdoor unit fan system. The primary objective was to improve condenser fan performance while reducing motor power. We also examined potential changes to the condenser exhaust configuration to enhance air moving efficiency performance. A secondary objective was to provide sound reductions as lower noise AC equipment is important to consumers.

Within conducted tests, an improved high efficiency fan design and advanced exhaust diffuser section reduced fan motor power requirements by approximately 49 W (26%) while providing superior air flow. …


Literature Review Of The Impact And Need For Attic Ventilation In Florida Homes, Florida Solar Energy Center, Danny Parker May 2005

Literature Review Of The Impact And Need For Attic Ventilation In Florida Homes, Florida Solar Energy Center, Danny Parker

FSEC Energy Research Center®

The Florida Department of Community Affairs (DCA) is seeking to examine the impact and necessity of residential attic ventilation in Florida homes. Here, we provide technical support by examining existing data sources on the impacts of attic ventilation both on cooling and heating energy use as well as to attic and home moisture levels. In particular we evaluate the issues with sealed attic construction where the attic is unvented and expanded foam insulation is applied directly to the underside of the roof decking.

We also report the data from Florida Solar Energy Center (FSEC) instrumented facilities to add unique information …


Theoretical Evaluation Of The Nightcool Nocturnal Radiation Cooling Concept, Florida Solar Energy Center, Danny Parker Apr 2005

Theoretical Evaluation Of The Nightcool Nocturnal Radiation Cooling Concept, Florida Solar Energy Center, Danny Parker

FSEC Energy Research Center®

An evaluation has been conducted of the potential of a night sky cooling system to substantially reduce space cooling needs in homes in North American climates. The report describes the innovative residential cooling system which uses nocturnal night sky radiation from a roof integrated radiator. The system uses a sealed attic covered by a highly conductive metal roof which is selectively linked by air flow to the main zone with the attic zone to provide cooling- largely during nighttime hours. Available house mass is used to store sensible cooling. Additional dehumidification is done during the evening hours as warranted by …


Executive Summary: Evaluation Of The Impact Of Vacant Home Space Conditioning Strategies On Summer Relative Humidity, Energy, And Peak Load, Florida Solar Energy Center, Charles Withers, Jr. Jan 2005

Executive Summary: Evaluation Of The Impact Of Vacant Home Space Conditioning Strategies On Summer Relative Humidity, Energy, And Peak Load, Florida Solar Energy Center, Charles Withers, Jr.

FSEC Energy Research Center®

The Vacant Home Space Conditioning Study was sponsored by Florida Power & Light (FPL) as part of its Conservation R&D Program and carried out by the Florida Solar Energy Center (FSEC). In the US, about one in four retiree "snowbirds" make Florida their destination to escape the northern cold. Snowbird residents number more than 900,000 in Florida during the winter. In some counties of FPL's territory these seasonal residents compose up to 15% of the population (Shih, 1981). This pattern of seasonal occupancy creates a need for space conditioning guidelines for vacant homes to avoid mold problems while minimizing both …


Validation Of Energygauge® Usa Using The Hers Bestest, Florida Solar Energy Center, Philip W. Fairey Dec 2004

Validation Of Energygauge® Usa Using The Hers Bestest, Florida Solar Energy Center, Philip W. Fairey

FSEC Energy Research Center®

This report presents results from the testing and validation of the EnergyGauge USA home energy rating software conducted using the HERS BESTEST procedures. The results show that EnergyGauge USA is an excellent and verifiable simulation program that is capable of meeting all national requirements for home energy rating software tools.


Cold Climate Case Study; High Efficiency North Dakota Twin Homes, Florida Solar Energy Center, Dave Chasar Dec 2004

Cold Climate Case Study; High Efficiency North Dakota Twin Homes, Florida Solar Energy Center, Dave Chasar

FSEC Energy Research Center®

The Eastern Dakota Housing Alliance has completed 8 of 20 planned multi-family and single-family dwellings on Selkirk Circle in Grand Forks, North Dakota. Four twin-home (duplex) units were completed in March of 2003 (Phase I) and four more identical units were completed in February of 2004 (Phase II). Four additional units (Phase III) are due for completion by mid-summer, 2004. Design assistance and performance testing were provided by the Building America Industrialized Housing Project with the goal of achieving up to 50% energy savings over the 1993 Model Energy Code.

To approach this level of savings, various envelope and equipment …


Cooling Load Reduction And Air Conditioner Design In A 19th Century Florida House Museum, Florida Solar Energy Center, Dave Chasar Nov 2004

Cooling Load Reduction And Air Conditioner Design In A 19th Century Florida House Museum, Florida Solar Energy Center, Dave Chasar

FSEC Energy Research Center®

Restoration plans at the H.S. Williams house included the installation of a space conditioning system. This contract report details how building envelope construction and air conditioner design were optimized as a system. Many aspects of the effort lent themselves to maintaining important "character-defining" features of the building including the resurrection of passive cooling attributes like light colored exterior paint and operable storm shutters. In addition, outside air infiltration was measured on the Williams house and six other balloon-frame homes to document this often significant cooling load component.


Performance And Applications Of Gossamer Wind (Tm) Solar Powered Ceiling Fans, Florida Solar Energy Center, M. Lubliner Sep 2004

Performance And Applications Of Gossamer Wind (Tm) Solar Powered Ceiling Fans, Florida Solar Energy Center, M. Lubliner

FSEC Energy Research Center®

Ceiling fans provide a cooling breeze, reduce temperature stratification and improve thermal comfort. Ceiling fans save energy in homes by improving thermal comfort, which results in changes to the thermostat set-point or reduced use of air conditioning.


Photovoltaics: Disaster And Energy Security Applications, Florida Solar Energy Center, William Young Aug 2004

Photovoltaics: Disaster And Energy Security Applications, Florida Solar Energy Center, William Young

FSEC Energy Research Center®

The modernization of our lives with the use of electronic devices has contributed to a steadily increasing dependence on electric power. The degree of importance of electricity is temporarily highlighted with any type of power outage, whether caused by an accident, a natural disaster or a terrorist attack. A disaster can leave many people without adequate medical services, potable water, electrical service and communications.

There is a value in applying photovoltaics (solar electric) to create disaster-resistant buildings and communities, which is to reduce losses and improve quality of life. Photovoltaics provide a viable source of electric power for energy security …


Geographic Variation In Potential Of Rooftop Residential Photovoltaic Electric Power Production In The United States, Florida Solar Energy Center, Matthew Lombardi Aug 2004

Geographic Variation In Potential Of Rooftop Residential Photovoltaic Electric Power Production In The United States, Florida Solar Energy Center, Matthew Lombardi

FSEC Energy Research Center®

This paper describes a geographic evaluation of Zero Energy Home (ZEH) potential, specifically an assessment of residential roof-top solar electric photovoltaic (PV) performance around the United States and how energy produced would match up with very-efficient and super-efficient home designs. We performed annual simulations for 236 TMY2 data locations throughout the United States on two highly-efficient one-story 3-bedroom homes with a generic grid-tied solar electric 2 kW PV system. These annual simulations show how potential annual solar electric power generation (kWh) and potential energy savings from PV power vary geographically around the U.S. giving the user in a specific region …


Energy Star Manufactured Homes: The Plant Certification Process, Florida Solar Energy Center, Dave Chasar Aug 2004

Energy Star Manufactured Homes: The Plant Certification Process, Florida Solar Energy Center, Dave Chasar

FSEC Energy Research Center®

In an on-going collaboration over the last ten years, researchers have worked with the manufactured housing industry offering building science advice and conducting diagnostic testing (Chandra et al 2002). This partnership resulted in the first two HUD code ENERGY STAR homes in 1997 and the development of standardized, in-plant Duct Blaster testing in 2001. One manufacturer is currently testing duct leakage on every home in 12 factories, representing over 8,000 homes per year.

In 2001, the U.S. Environmental Protection Agency (EPA) introduced the ENERGY STAR label for manufactured homes. Guidelines for this program focus on certification of the HUD-code plant …


Measured Energy And Peak Demand Reductionfrom High Efficiency Air Conditioner Replacement, Florida Solar Energy Center, John Masiello Aug 2004

Measured Energy And Peak Demand Reductionfrom High Efficiency Air Conditioner Replacement, Florida Solar Energy Center, John Masiello

FSEC Energy Research Center®

A utility load research project has monitored over 167 single-family residences in Central Florida collecting baseline 15-minute data on air conditioner (AC) power consumption, interior air temperatures and appliance loads over a two year period. Within the project we evaluated the impact of replacing older existing air conditioners with modern high efficiency equipment.


Preliminary Evaluation Of Performance Enhanced Relocatable Classrooms In Three Climates, Florida Solar Energy Center, Danny Parker Aug 2004

Preliminary Evaluation Of Performance Enhanced Relocatable Classrooms In Three Climates, Florida Solar Energy Center, Danny Parker

FSEC Energy Research Center®