Open Access. Powered by Scholars. Published by Universities.®

Biomechanical Engineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Electro-Mechanical Systems

Institution
Keyword
Publication Year
Publication
Publication Type
File Type

Articles 1 - 30 of 44

Full-Text Articles in Biomechanical Engineering

Smart Sleeve, Evan Abalos, Bright Jung, Owen Bowling, Wyatt Eberhart Jun 2026

Smart Sleeve, Evan Abalos, Bright Jung, Owen Bowling, Wyatt Eberhart

Mechanical Engineering

Quantifying human arm muscle activity is essential for understanding human movements and helping individuals who suffer from motor or neurological impairments such as stroke or traumatic brain injuries. Today, these individuals, as well as clinicians, researchers, and athletes, face many challenges when using the traditional surface electromyography (sEMG) systems to monitor muscle activities, including complex setup, restricted mobility, discomfort, inconsistent placement of electrodes, and lack of accuracy. Therefore, a comfortable EMG sleeve device that accurately measures arm movement without interfering with daily tasks is needed, which the team will be designing, manufacturing, and testing as their senior project. In addition, …


Development Of Low-Cost Triaxial Force Sensor For Measurement Of Human-Exoskeleton Interaction Forces, Hamdan Khan Sarvathullah May 2026

Development Of Low-Cost Triaxial Force Sensor For Measurement Of Human-Exoskeleton Interaction Forces, Hamdan Khan Sarvathullah

All Theses

Contemporary research suggests that shear force is a major contributor to discomfort and pressure injury. However, the variation of shear forces during human-exoskeleton interaction dynamics is a highly unexplored field. The high cost of commercial triaxial force sensors may be a major factor in the notable lack of research in this field. Therefore, in this paper, we present a low-cost, 3D-printed triaxial force sensor designed specifically to measure the triaxial interaction forces between an exoskeleton and its user. The triaxial force sensor uses Carbon-Black/Silicone Rubber (CB/SR) strings to measure shear forces, whereas the normal force is measured with a Force …


Implantable, Sensor-Embedded Vascular Graft Towards Wireless Monitoring Of Stenosis, Nnamdi Dike Apr 2026

Implantable, Sensor-Embedded Vascular Graft Towards Wireless Monitoring Of Stenosis, Nnamdi Dike

LSU Master's Theses

Arteriovenous (AV) grafts are commonly used to provide vascular access for hemodialysis in patients with end-stage renal disease. Despite their widespread use, AV grafts are prone to complications such as stenosis and thrombosis. Early detection of these conditions remains challenging with current monitoring methods too costly or insufficient. This work presents the design, fabrication, and validation of an LC pressure sensor embedded within a model AV graft to enable real-time monitoring. The proposed system integrates a parallel-plate capacitive pressure sensor with a spiral inductor to form an LC circuit embedded within an elastomeric graft wall. The Ecoflex 00-30 dielectric layer …


Wearable Sensor System Used To Measure Linear And Angular Acceleration Of The Head Of American Football Players, David A. Emerson Mar 2026

Wearable Sensor System Used To Measure Linear And Angular Acceleration Of The Head Of American Football Players, David A. Emerson

LSU Master's Theses

American football players are repeatedly subject to high-velocity impacts; collisions can exceed 100 g in the NFL [1]. Rotational accelerations of the head caused by high-velocity collisions have been proven to be extremely damaging to the highly organized brain fibers at the brain-skull interface [2]. The sensor system (SS) measures the nonplanar acceleration at four locations on a chin strap using ADXL314 accelerometers and utilizes rigid-body kinematics to estimate the head rotational state from the measured acceleration of the SS [3]. The SS was validated through progressive testing, including steady-state, linear impact, and rotational impact testing. The ADLX314 sensor exhibited …


Automation And Habitat Development For A Space Based Marine Life Environment, Logan Trimmer, Alexander Hang Jan 2026

Automation And Habitat Development For A Space Based Marine Life Environment, Logan Trimmer, Alexander Hang

Harrisburg University Other Works

This project was a cross-collaboration between the Environmental Sciences and Advanced Manufacturing and Robotics programs for the company Monolith Space.

The goal of this project was to design an autonomous system to be able to track qualities of water in an aquaculture system designed to be sent to space.


Advancing Prosthetic Technology: 3d-Printed Robotic Arm With Micro Linear Actuators, Vu Tran, Nathan Reed, Mahdi Yazdanpour Jan 2025

Advancing Prosthetic Technology: 3d-Printed Robotic Arm With Micro Linear Actuators, Vu Tran, Nathan Reed, Mahdi Yazdanpour

Posters-at-the-Capitol

The increasing demand for affordable and accessible prosthetic solutions has driven innovation in the field of robotics. In this project, we present the design and development of a 3D-printed robotic prosthetic arm aimed at addressing the challenges faced by individuals with upper limb amputations. Our prosthetic arm utilizes five micro linear actuators to achieve precise and naturalistic movement. The design of the prosthetic arm prioritizes affordability and accessibility, with a focus on leveraging 3D printing technology to reduce manufacturing costs and enable customization. The use of micro linear actuators offers advantages in terms of compactness, lightweight construction, and efficient power …


Simplified Molecular Diagnostics Methods For Environmental Testing Of Pathogens And Other Applications, Mohammad Dehghan Banadaki Jan 2025

Simplified Molecular Diagnostics Methods For Environmental Testing Of Pathogens And Other Applications, Mohammad Dehghan Banadaki

Theses and Dissertations--Mechanical and Aerospace Engineering

Environmental Surveillance (ES) has emerged as a powerful tool to monitor the emergence and persistence of a pathogen within a facility or community using wastewater/water analysis. Over the past four years, implementation of ES has experienced an explosive acceleration, driven by efforts to monitor the spread of SARS-CoV-2, which has made ES a routinely used public health tool in many locations. We can now use ES to measure the emergence/presence/abundance of different viruses (e.g., SARS-CoV-2, influenza, mpox), bacteria (e.g., E. coli, V. cholerae, antibiotic-resistant strains), fungi (e.g., C. auris), and other biological markers indicative of infectious diseases. However, its broad …


3d Printed Microfluidic Fabrication Methodology, Characterization, Mechanical Design, And Applications In Electrostatic Artificial Muscles And Benthic Microbial Fuel Cells, Terak B. Hornik Nov 2024

3d Printed Microfluidic Fabrication Methodology, Characterization, Mechanical Design, And Applications In Electrostatic Artificial Muscles And Benthic Microbial Fuel Cells, Terak B. Hornik

Master's Theses

The fabrication of microfluidic devices often requires specialized methods. The development of these methods requires careful characterization and understanding of the processes involved. Using primarily PolyJet 3D printing technology, microfluidics offers a wide scope of applications such as microfluidic benthic microbial fuel cells (MBMFCs) and electrostatic artificial muscles. MBMFCs benefit from the confinement of the microbes resulting in close proximity between the electrode and the organisms. Using a modular design called the Sponge, assembly and upscaling is possible. Electrostatic artificial muscles benefit from a microfluidic approach due to the non-linearity of electrostatic attraction creating disproportionate benefits when miniaturized. When designed …


Analysis Of Shock Absorption By Spring-Assisted Crutch Tips, Noah Hirschegger, Daegan Caime, Mohamed Atta Oct 2024

Analysis Of Shock Absorption By Spring-Assisted Crutch Tips, Noah Hirschegger, Daegan Caime, Mohamed Atta

Senior Theses

Angel Consulting was originally created to address the problem of excessive wear and tear on the joints of individuals who use crutches for long periods of time. This company has sought to alleviate these issues with a proprietary spring-assisted crutch tip, which reduces the impact of crutch use and will hopefully be able to assist people in alleviating joint damage and discomfort. The team's main purpose is to determine an optimal metric for both marketability and effectiveness and to test the prototype design to ensure the validity of assistance for people who require chronic crutch use. To do this, we …


Development Of A 2-Dof Robotic Uterus Manipulator, Jeremiah Eggleston, Nicole Pishnery, Siddharth Navaneetha Raj Jan 2024

Development Of A 2-Dof Robotic Uterus Manipulator, Jeremiah Eggleston, Nicole Pishnery, Siddharth Navaneetha Raj

Williams Honors College, Honors Research Projects

The objective for our senior design project was to design a better uterus manipulator to assist with hysterectomies. We worked with our advisor Dr. Sam Song from the university’s Mechanical Engineering department. There are a variety of uterus manipulators on the market currently, each with unique design features to make the manipulator safer and more effective (van den Haak et al, 2015). Our group’s design modifies and sets itself apart from manipulators currently on the market. Going off others’ attempts to make a better manipulator (Fournelis, 2022), the key modifications our design incorporates are an additional degree of freedom (for …


A Novel Magnetorheological Pump Concept For Insulin Delivery, Mohammad Towhidul Islam Rimon Jan 2024

A Novel Magnetorheological Pump Concept For Insulin Delivery, Mohammad Towhidul Islam Rimon

College of Graduate Studies: Theses & Dissertations

Over the past 25 years, awareness of type 1 diabetes has significantly increased, leading to a comprehensive understanding of various aspects, including its genetics, epidemiology, and disease burden. According to the Type 1 Diabetic Index, about 8.7 million people around the world live with this long-term autoimmune disease characterized by insulin deficiency and resultant hyperglycemia. However, the increased availability and utilization of artificial pancreas systems could potentially save 673,000 lives by 2040. Although, the advancement of diabetes technology offers Type 1 diabetic patients more tools to enhance glycemic management and achieve effective outcomes, many patients are still hesitant to adopt …


Controlled Voltage Of Hot Snare Polypectomy Device In Electrosurgical Device, Saidi Olayinka Olalere Jan 2022

Controlled Voltage Of Hot Snare Polypectomy Device In Electrosurgical Device, Saidi Olayinka Olalere

College of Graduate Studies: Theses & Dissertations

The study is used to understand the working procedure of the Olympus PSD-30 Electrosurgical Unit which a high-frequency alternating current is to measure the voltage and power output from the unit when used for a surgical operation to determine the extent of tissue damage. The output power and voltage were as examined with the stopwatch, then with an Arduino time based for 1, 2, and 3 seconds to understand the different modes of the cut and coagulation feedback with an RCC circuit used to mimic the human body. This shows a pattern in which the feedback power increases, and voltage …


3-D Positioning System For Trackable Adjustments Of Papillary Muscles, Ryan Michael Winters, Micaela Andrea Bataclan, Christine Do, Giselle Morales Jun 2021

3-D Positioning System For Trackable Adjustments Of Papillary Muscles, Ryan Michael Winters, Micaela Andrea Bataclan, Christine Do, Giselle Morales

Biomedical Engineering

Redacted.


Magnetic Gradient-Based Magnetic Tweezer System For 3d And Swarm Control Of Microswimmer, Xiao Zhang May 2021

Magnetic Gradient-Based Magnetic Tweezer System For 3d And Swarm Control Of Microswimmer, Xiao Zhang

Mechanical Engineering Research Theses and Dissertations

Microscale manipulation has very promising potential in medical applications such as drug delivery, minimal and invasion surgery. Contactless control is preferable as remote manipulation is necessary for in vivo applications. Among different control methods, magnetic power source is more suitable and robust for the applications mentioned above. Presented here is a magnetic tweezer system, which manipulates microscale magnetic particles using magnetic forces created by magnetic field gradient. The proposed system has three advantages: First, force applied by the magnetic tweezer system does not contact with the target object and can be generated in different directions. Second, the magnetic tweezer system …


Husky Hand: A Low-Cost Electro-Mechanical Prosthetic Arm For The Underprivileged, Adam Robert Apr 2021

Husky Hand: A Low-Cost Electro-Mechanical Prosthetic Arm For The Underprivileged, Adam Robert

Thinking Matters Symposium

A continuation of a low-cost prosthetic upper limb prototype design which was investigated in EGN 301. The prosthetic is specifically designed for the needs and requirements of under privileged individuals in the Dominican Republic with upper limb amputations. The project focuses on the creation of an open-source computer aided prosthetic hand/arm model. The design allows consumer-grade fused filament fabrication (FFF) 3-D printers to be used. The improved design allows for the integration of the PQ-12 linear actuator for grasp and finger control. This simplifies the assembly, while, also reducing the size and mass of the whole unit. Producing a low-cost …


Design Of Compact Signal Distribution Device For Hoffman Reflex Methodologic Applications In Sports Medicine, Abayomi E. Folaranmi Jan 2021

Design Of Compact Signal Distribution Device For Hoffman Reflex Methodologic Applications In Sports Medicine, Abayomi E. Folaranmi

College of Graduate Studies: Theses & Dissertations

A study is presented on the design of compact sized signal distribution device for Hoffman reflex methodological applications in sports medicine. Established conventional method for measuring and recording human or animal nervous system response to external electrical stimulus was considered in this study. Challenges with measuring and recording techniques which introduces inaccuracies and unreliability of reflex response data obtained was analyzed, this work is aimed at improving the reliability of H-reflex d measuring and recording technique for the purpose of reducing inaccuracies introduced to data obtained because of conventional methodologic approach. Inaccuracies due to changes in subject muscle geometry and …


Nebulizer-Based Systems To Improve Pharmaceutical Aerosol Delivery To The Lungs, Benjamin M. Spence Jan 2021

Nebulizer-Based Systems To Improve Pharmaceutical Aerosol Delivery To The Lungs, Benjamin M. Spence

Theses and Dissertations

Combining vibrating mesh nebulizers with additional new technologies leads to substantial improvements in pharmaceutical aerosol delivery to the lungs across therapeutic administration methods. In this dissertation, streamlined components, aerosol administration synchronization, and/or Excipient Enhanced Growth (EEG) technologies were utilized to develop and test several novel devices and aerosol delivery systems. The first focus of this work was to improve the poor delivery efficiency, e.g., 3.6% of nominal dose (Dugernier et al. 2017), of aerosolized medication administration to adult human subjects concurrent with high flow nasal cannula (HFNC) therapy, a form of continuous-flow non-invasive ventilation (NIV). The developed Low-Volume Mixer-Heater (LVMH) …


Deep-Sea Water Collector, Chandler Jones, Jenny Verheul, Michael Di Giorgio Nov 2020

Deep-Sea Water Collector, Chandler Jones, Jenny Verheul, Michael Di Giorgio

Mechanical Engineering

Properties such as nutrients, DNA, pH levels, and primary productivity are difficult to measure onboard an Underwater Remotely Operated Vehicle (UROV) as mobile submarine sensors are highly expensive and conventional water capture devices are too large to be equipped. However, these properties provide an integral view into our oceans, the species that inhabit them, and our influence on the environment. Collected samples of seawater taken back to labs allow researchers to see a clearer picture of ecosystems’ inhabitants and lifecycle with the analysis of Environmental DNA (eDNA) among many other properties. The scope of this project is to design a …


Control And Locomotion Of Inertially And Magnetically Actuated Multi-Scale Robotic Systems, Ehab Al Khatib May 2020

Control And Locomotion Of Inertially And Magnetically Actuated Multi-Scale Robotic Systems, Ehab Al Khatib

Mechanical Engineering Research Theses and Dissertations

In this research, two actuation systems were introduced, inertial and magnetic actuation. In the inertial actuation, the robot used the transfer of momentum to navigate, and this momentum could be generated by spinning masses and wheels. Recent studies in our System Laboratory proved that a wide range of inertially actuated locomotion systems could be generated. This can be achieved by using a family tree approach, starting from a very simple system, and progressively evolving it to more complex ones. The motion diversity of these robots inspired us to extend their locomotion from a macro scale to millimeter and micro scales. …


System Integration Of C-Arm Robotic Prototype Using Motion Capture Guidance For Accurate Repositioning, Alireza Yazdanshenas Jul 2019

System Integration Of C-Arm Robotic Prototype Using Motion Capture Guidance For Accurate Repositioning, Alireza Yazdanshenas

Mechanical Engineering Theses

One of the important surgical tools in spinal surgery is the C-Arm X-ray System. The C-Arm is a large “C” shaped and manually maneuvered arm that provides surgeons and X-ray technicians the ability to take quick quality X-rays during surgery. Because of its five degrees of freedom, the C-Arm can be manually maneuvered around the patient to provide many angles and perspectives, ensuring surgical success.

This system works fine for most surgical procedures but falls short when the C-Arm must be moved out of the way for complicated surgical procedures.

The aim of this thesis is to develop an accurate …


Development Of A Sonically Powered Biodegradable Nanogenerator For Bone Regeneration, Avi S. Patel May 2019

Development Of A Sonically Powered Biodegradable Nanogenerator For Bone Regeneration, Avi S. Patel

University Scholar Projects

Background: Reconstruction of bone fractures and defects remains a big challenge in orthopedic surgery. While regenerative engineering has advanced the field greatly using a combination of biomaterial scaffolds and stem cells, one matter of difficulty is inducing osteogenesis in these cells. Recent works have shown electricity’s ability to promote osteogenesis in stem cell lines when seeded in bone scaffolds; however, typical electrical stimulators are either (a) externally housed and require overcomplex percutaneous wires be connected to the implanted scaffold or (b) implanted non-degradable devices which contain toxic batteries and require invasive removal surgeries.

Objective: Here, we establish a biodegradable, piezoelectric …


Danny’S Recumbent Bike Accessibility Device Final Design Report, Joseph J. Lee, Huy Nguyen, Jack Mcatee, John Kulick May 2019

Danny’S Recumbent Bike Accessibility Device Final Design Report, Joseph J. Lee, Huy Nguyen, Jack Mcatee, John Kulick

Mechanical Engineering

The purpose of this document is to fully define our design solution and explain our manufacturing and testing results. Our project’s goal is to find a way to allow Danny Knutson, a retired Navy pilot and incomplete quadriplegic with limited use of his arms and an impaired sense of balance, to enter and exit his recumbent tricycle without any discomfort for him or his aide. We completed multiple interviews with Danny, patent research, existing product research, and other technical literature research in order to fully understand the problem. We synthesized this information to create a concrete list of customer wants …


Exoskeleton Leg Brace, Aaron Indermuhle, Magomed Kasumov, Cevat Bagcioglu, Lucas Battaglia Jan 2019

Exoskeleton Leg Brace, Aaron Indermuhle, Magomed Kasumov, Cevat Bagcioglu, Lucas Battaglia

Williams Honors College, Honors Research Projects

This report details the design process of a lower limb exoskeleton leg brace for elderly people with walking disabilities or others with disabilities that limit mobility. While there are other similar products on the market, the general design can be improved and these improvements have been implemented into the design presented within. Among these improvements are progress in efficiency, weight, user comfort, and cost. The results of the study are the design of a novel leg brace that improves on existing designs in each of these areas.

Our design solution incorporates the use of a single leg brace with no …


Wheelie King Trainer And Controller, Michael C. Uytingco, Paul E. Hubner, Dmitriy Petrovykh Dec 2018

Wheelie King Trainer And Controller, Michael C. Uytingco, Paul E. Hubner, Dmitriy Petrovykh

Mechanical Engineering

The ``wheelie'' is a popular, classic bicycle trick which novice bicyclists often attempt as an introduction to advanced bike tricks. However, many are hesitant to try due to the risks and safety hazards associated with performing one. The purpose of this project is to create an on-board system which will assist a user in maintaining a wheelie after achieving the required position while incorporating safety mechanisms to prevent the user from injuring themselves or others. Additional requirements of the system are non-obstructive features and seamless transitioning between wheelie conditions.

Upon researching the state of wheelie technology, existing products, such as …


Modeling Of Swimming Cells From Nano-Scale To Micro-Scale, Yicheng Zhao May 2018

Modeling Of Swimming Cells From Nano-Scale To Micro-Scale, Yicheng Zhao

McKelvey School of Engineering Graduate Student Theses & Dissertations

Certain human genetic diseases -- primary ciliary dyskinesia, infertility, and hydrocephalus -- are characterized by changes in beat frequency and waveform of cilia and flagella. Chlamydomonas reinhardtii, which is a single-cell green alga about ten micrometers in diameter that swims with two flagella, serves as an excellent biological model because its flagella share the same structure and genetic background as mammalian cilia and flagella. This study uses the finite element method to investigate the behavior of C. reinhardtii swimming from nano-scale to micro-scale. At the device-level, micro-scale modeling indicates that well-designed acoustic microfluidic devices can be used to trap groups …


Microfluidic Technology And Application In Urinal Analysis, Jiwen Xiang Feb 2018

Microfluidic Technology And Application In Urinal Analysis, Jiwen Xiang

LSU Doctoral Dissertations

Microfluidic technology offers numerous advantages in minimizing and integrating the traditional assays. However, the lack of efficient control components of the microfluidic systems has been hindering the widely commercialization of the technology. The research work in this dissertation focused on the development of effective control components for microfluidic applications.

A linear peristaltic pump was firstly designed, fabricated, and tested for conventional microfluidics by synchronously compressing the microfluidic channel with a miniature cam-follower system in Chapter 2. The miniature cam-follower system and microfluidic chip was prototyped using three-dimensional (3D) printing technology and soft lithography technology. Results from experimental test showed that …


Simulation Of Human Ankle Trajectory During Stance Phase Of Gait, Leslie Castelino Jan 2017

Simulation Of Human Ankle Trajectory During Stance Phase Of Gait, Leslie Castelino

Dissertations, Master's Theses and Master's Reports

A simulation was developed which mimics the human gait characteristics based on the input of an individual’s gait trajectory. This simulation also estimates the impedance of the human ankle based on the ground reaction forces measured by the force plate. This simulation will accept alterations of the following parameters: total body weight, weight of the shank, weight of the foot, trajectories of the shank and foot of the individual and orientation of the force plate, which would generate a new gait trajectory for the ankle during the stance phase of gait. The goal of this simulation was to validate the …


Mechanical Reliability Of Implantable Polyimide-Based Magnetic Microactuators For Biofouling Removal, Christian G. Figueroa-Espada, Qi Yang, Hyowon Lee Aug 2016

Mechanical Reliability Of Implantable Polyimide-Based Magnetic Microactuators For Biofouling Removal, Christian G. Figueroa-Espada, Qi Yang, Hyowon Lee

The Summer Undergraduate Research Fellowship (SURF) Symposium

Hydrocephalus is a neurological disorder that typically requires a long-term implantation of a shunt system to manage its symptoms. These shunt systems are notorious for their extremely high failure rate. More than 40% of all implanted shunt systems fail within the first year of implantation. On average, 85% of all hydrocephalus patients with shunt systems undergo at least two shunt-revision surgeries within 10 years of implantation. A large portion of this high failure rate can be attributed to biofouling-related obstructions and infections. Previously, we developed flexible polyimide-based magnetic microactuators to remove obstructions formed on hydrocephalus shunts. To test the long-term …


Biomimetic Seal Flipper Test Rig, Gordon D. Belyea, Laura Kawashiri, Dylan Rinker, Kurt Beske Jun 2016

Biomimetic Seal Flipper Test Rig, Gordon D. Belyea, Laura Kawashiri, Dylan Rinker, Kurt Beske

Mechanical Engineering

No abstract provided.


Health Condition Monitoring And Fault-Tolerant Operation Of Adjustable Speed Drives, Jiangbiao He Oct 2015

Health Condition Monitoring And Fault-Tolerant Operation Of Adjustable Speed Drives, Jiangbiao He

Dissertations (1934 -)

Adjustable speed drives (ASDs) have been extensively used in industrial applications over the past few decades because of their benefits of energy saving and control flexibilities. However, the wider penetration of ASD systems into industrial applications is hindered by the lack of health monitoring and fault-tolerant operation techniques, especially in safety-critical applications. In this dissertation, a comprehensive portfolio of health condition monitoring and fault-tolerant operation strategies is developed and implemented for multilevel neutral-point-clamped (NPC) power converters in ASDs. Simulations and experiments show that these techniques can improve power cycling lifetime of power transistors, on-line diagnosis of switch faults, and fault-tolerant …