Open Access. Powered by Scholars. Published by Universities.®

Acoustics, Dynamics, and Controls Commons™

Open Access. Powered by Scholars. Published by Universities.®

Medicine and Health Sciences

Institution
Keyword
Publication Year
Publication
Publication Type
File Type

Articles 31 - 40 of 40

Full-Text Articles in Acoustics, Dynamics, and Controls

Average Speech Directivity, Samuel D. Bellows, Claire M. Pincock, Jennifer K. Whiting, Timothy W. Leishman Nov 2019

Average Speech Directivity, Samuel D. Bellows, Claire M. Pincock, Jennifer K. Whiting, Timothy W. Leishman

Directivity

Speech directivity describes the angular dependence of acoustic radiation from a talker’s mouth and nostrils and diffraction about his or her body and chair (if seated). It is an essential physical aspect of communication affecting sounds and signals in acoustical environments, audio, and telecommunication systems. Because high-resolution, spherically comprehensive measurements of live, phonetically balanced speech have been unavailable in the past, the authors have undertaken research to produce and share such data for simulations of acoustical environments, optimizations of microphone placements, speech studies, and other applications. The measurements included three male and three female talkers who repeated phonetically balanced passages …


System Integration Of C-Arm Robotic Prototype Using Motion Capture Guidance For Accurate Repositioning, Alireza Yazdanshenas Jul 2019

System Integration Of C-Arm Robotic Prototype Using Motion Capture Guidance For Accurate Repositioning, Alireza Yazdanshenas

Mechanical Engineering Theses

One of the important surgical tools in spinal surgery is the C-Arm X-ray System. The C-Arm is a large “C” shaped and manually maneuvered arm that provides surgeons and X-ray technicians the ability to take quick quality X-rays during surgery. Because of its five degrees of freedom, the C-Arm can be manually maneuvered around the patient to provide many angles and perspectives, ensuring surgical success.

This system works fine for most surgical procedures but falls short when the C-Arm must be moved out of the way for complicated surgical procedures.

The aim of this thesis is to develop an accurate …


Procedure To Measure The Penetration Of One Mechanical Filter For Nanoparticles: Validation By Comparison, Pooya Abdolghader, Clothilde Brochot, Fariborz Haghighat, Ali Bahloul Jan 2019

Procedure To Measure The Penetration Of One Mechanical Filter For Nanoparticles: Validation By Comparison, Pooya Abdolghader, Clothilde Brochot, Fariborz Haghighat, Ali Bahloul

Études primaires

Nanoparticles (NPs) are particles of less than or equal to 100 nm in diameter. Due to their size, they have a significant effect on health and safety of people. Capture of these NPs in general ventilation systems by filters remains one of the most widely used means of protection due to its relative simplicity of implementation and its effectiveness for capturing various size of particles. In North America, filters used in general ventilation systems are tested by the ANSI/ASHRAE Standard 52.2 and are graded according to their efficiency, which is a function of particle diameter. However, the current standard limits …


A Biomimetic Approach To Controlling Restorative Robotics, Matthew T. Boots Jan 2019

A Biomimetic Approach To Controlling Restorative Robotics, Matthew T. Boots

Graduate Theses, Dissertations, and Problem Reports (ETD)

Movement is the only way a person can interact with the world around them. When trauma to the neuromuscular systems disrupts the control of movement, quality of life suffers. To restore limb functionality, active robotic interventions and/or rehabilitation are required. Unfortunately, the primary obstacle in a person’s recovery is the limited robustness of the human-machine interfaces. Current systems rely on control approaches that rely on the person to learn how the system works instead of the system being more intuitive and working with the person naturally. My research goal is to design intuitive control mechanisms based on biological processes termed …


A Transfer Matrix Model Of The Iec 60318-4 Ear Simulator: Application To The Simulation Of Earplug Insertion Loss, Yu Luan, Franck Sgard, Simon Benacchio, Hugues Nélisse, Olivier Doutres Jan 2019

A Transfer Matrix Model Of The Iec 60318-4 Ear Simulator: Application To The Simulation Of Earplug Insertion Loss, Yu Luan, Franck Sgard, Simon Benacchio, Hugues Nélisse, Olivier Doutres

Études primaires

The IEC 60318-4 ear simulator is used to measure the insertion loss (IL) of earplugs in the ear canal of an acoustical test fixture (ATF) and is designed to represent an average acoustic impedance (in a reference plane) of the human ear. The ear simulator is usually modeled using a lumped parameter model (LPM) which has frequency limitations and inadequately accounts for the thermo-viscous effects in the simulator. The simulator numerical models that can better deal with the thermo-viscous phenomena often lack essential geometric details. Most related studies also suffer from the lack of experimental validation of the models. Therefore, …


An Axisymmetric Finite Element Model To Study The Earplug Contribution To The Bone Conduction Occlusion Effect, Martin K. Brummund, Franck Sgard, Yvan Petit, Frédéric Laville, Hugues Nélisse Jan 2015

An Axisymmetric Finite Element Model To Study The Earplug Contribution To The Bone Conduction Occlusion Effect, Martin K. Brummund, Franck Sgard, Yvan Petit, Frédéric Laville, Hugues Nélisse

Études primaires

An axisymmetric linear elasto-acoustic finite element (FE) model of an occluded human external ear is proposed to simulate the bone conduction occlusion effect (OE). The model consists of a cylindrical ear canal cavity surrounded by layers of biological tissues (skin, cartilage and bone) in which an earplug is inserted. Geometrical and material properties are taken from the literature. OEs are predicted for foam and silicone earplug FE-models using COMSOL Multiphysics (COMSOL®, Sweden). The FE-model is shown to predict the experimental OE measured in two healthy human reference groups wearing foam or silicone earplugs, satisfactorily. Deviations between model and experiment are …


Age-Related Changes To The Production Of Linguistic Prosody, Daniel Richard Barnes Jan 2013

Age-Related Changes To The Production Of Linguistic Prosody, Daniel Richard Barnes

Open Access Theses

The production of speech prosody (the rhythm, pausing, and intonation associated with natural speech) is critical to effective communication. The current study investigated the impact of age-related changes to physiology and cognition in relation to the production of two types of linguistic prosody: lexical stress and the disambiguation of syntactically ambiguous utterances. Analyses of the acoustic correlates of stress: speech intensity (or sound-pressure level; SPL), fundamental frequency (F0), key word/phrase duration, and pause duration revealed that both young and older adults effectively use these acoustic features to signal linguistic prosody, although the relative weighting of cues differed by group. Differences …


Intelligibility Of Electrolarynx Speech Using A Novel Actuator, Brian Madden, Mark Nolan, Ted Burke, James Condron, Eugene Coyle Jun 2010

Intelligibility Of Electrolarynx Speech Using A Novel Actuator, Brian Madden, Mark Nolan, Ted Burke, James Condron, Eugene Coyle

Conference Papers

During voiced speech, the larynx provides quasi-periodic acoustic excitation of the vocal tract. Following a laryngectomy, some people speak using an electrolarynx which replaces the excitatory function of the absent larynx. Drawbacks of conventional electrolarynx designs include the buzzing monotonic sound emitted, the need for a free hand to operate the device, and difficulty experienced by many laryngectomees in adapting to its use. Despite these shortcomings, it remains the preferred method of speech rehabilitation for a substantial minority of laryngectomees. In most electrolarynxes, mechanical vibrations are produced by a linear electromechanical actuator, the armature of which percusses against a metal …


Indentation Fracture Of Bovine Cortical Bone: Acoustic Emission Technique, Ashkan Safari, Ger Reilly, Brendan Mccormack Jan 2006

Indentation Fracture Of Bovine Cortical Bone: Acoustic Emission Technique, Ashkan Safari, Ger Reilly, Brendan Mccormack

Conference Papers

Indentation cutting may result in microcracking and main crack growth which was previously reported. In this study, we recorded the AE signals produced by cracking processes during cutting on cortical bone, measuring the cutting force and correlating between load-displacement curves and AE activities.


Analysis Of Indentation Loading Of Cortical Bone Using Acoustic Emission Techniques, Ashkan Safari, Ger Reilly, Brendan Mccormack Dec 2005

Analysis Of Indentation Loading Of Cortical Bone Using Acoustic Emission Techniques, Ashkan Safari, Ger Reilly, Brendan Mccormack

Conference Papers

In this study, we recorded the number of Acoustic emission (AE) hits and related AE energy during indentation fracture of cortical bone using a PAC PCI-2 card and pico sensor. A threshold value of 43dB was used to filter premature trigger due to background noise. Registered AE hits had more than one count (threshold crossing). Amplifier gain was set at 40dB with a (0.1-1) MHz band pass filter. 8mm cubes of cortical bones were indented in the longitudinal direction at constant crosshead speed of 1 mm min-1 using a large 2D, 50˚ wedge indenter. We hypothesised that signals occurring as …