Open Access. Powered by Scholars. Published by Universities.®
- Discipline
-
- Energy Systems (280)
- Civil and Environmental Engineering (2)
- Acoustics, Dynamics, and Controls (1)
- Aerospace Engineering (1)
- Applied Mechanics (1)
-
- Civil Engineering (1)
- Computational Engineering (1)
- Controls and Control Theory (1)
- Electrical and Computer Engineering (1)
- Environmental Engineering (1)
- Industrial Engineering (1)
- Operations Research, Systems Engineering and Industrial Engineering (1)
- Systems Engineering and Multidisciplinary Design Optimization (1)
- Institution
- Publication Year
- Publication
- Publication Type
Articles 241 - 270 of 283
Full-Text Articles in Mechanical Engineering
Energy Efficiency For Florida Educational Facilities: The 1996 Energy Survey Of Florida Schools, Florida Solar Energy Center, Danny Parker
Energy Efficiency For Florida Educational Facilities: The 1996 Energy Survey Of Florida Schools, Florida Solar Energy Center, Danny Parker
FSEC Energy Research Center®
A detailed survey of energy use and related physical and operational characteristics of Florida's public schools has been completed. A mailed survey instrument was sent to all 2,512 schools throughout the state in March 1996. A total of 1, 298 surveys were returned -- a response rate of approximately 52%. Of these some 680 provided matching utility data. The survey data was analyzed to create a school energy use profile as well as to identify characteristics that may influence efficiency. Based on our findings, the total annual energy cost for the Florida school system totaled $205 million in 1995. As …
Impact Of Evaporator Coil Air Flow In Residential Air Conditioning Systems, Florida Solar Energy Center, Danny Parker
Impact Of Evaporator Coil Air Flow In Residential Air Conditioning Systems, Florida Solar Energy Center, Danny Parker
FSEC Energy Research Center®
The performance of conventional split system residential air conditioners is highly dependent on adequate air flow across the evaporator coil. Sufficient air flow is necessary to achieve a proper balance between sensible and latent cooling capacity. Typical target air flow rates are approximately 350 - 450 cubic feet per minute per ton (581 - 747 L/S per kW) of cooling capacity. The authors have measured the air flow across the coil in 27 installations in Florida. Both flow hood and strip heat resistance methods were used to measure air flow with an established protocol. The installations measured ranged in capacity …
Evaluation Of Resources And Energy Systems At Fort Jefferson Garden Key, Dry Tortugas National Park, Florida Solar Energy Center, James Dunlop
Evaluation Of Resources And Energy Systems At Fort Jefferson Garden Key, Dry Tortugas National Park, Florida Solar Energy Center, James Dunlop
FSEC Energy Research Center®
This report presents an evaluation of the resources and energy systems at Fort Jefferson, located on Garden Key in Dry Tortugas National Park, Florida. Conducted by Florida Solar Energy Center staff on June 11-12, 1997, this evaluation builds on a prior evaluation conducted in May 1989. The purpose of this evaluation was to document the energy and resource needs at the site, and to identify possibilities for reduced costs through conservation measures and renewable energy options.
Approximately 700 kWh of electrical energy is used at Fort Jefferson on a daily average, supplied exclusively by diesel-fueled generators. Average diesel fuel consumption …
Field Measurement Of Uncontrolled Air Flow And Depressurization In Restaurants, Florida Solar Energy Center, James Cummings
Field Measurement Of Uncontrolled Air Flow And Depressurization In Restaurants, Florida Solar Energy Center, James Cummings
FSEC Energy Research Center®
Field investigations were done in seven restaurants (subsample of a 63 commercial buildings study) to identify uncontrolled air flows and pressure imbalances. Testing included building airtightness tests, identification of building air barrier location, duct system airtightness, characterization of pressure differentials, building air flow balance, and infiltration/ventilation rates. All restaurants were found to operate at negative pressures which ranged from -0.003 inWC (-0.8 Pa) to -0.173 inWC (-43 Pa) and averaged -0.051 inWC (-12.7 Pa) under normal operation. The variables which affect depressurization are large exhaust fans, missing or undersized make-up air, intermittent outdoor air caused by the cycling of air …
How Contractors Really Size Air Conditioning Systems, Florida Solar Energy Center, Robin Vieira
How Contractors Really Size Air Conditioning Systems, Florida Solar Energy Center, Robin Vieira
FSEC Energy Research Center®
This paper presents results from 489 of the 5559 Florida air conditioning contractors surveyed (an 8.5% response rate) regarding equipment sizing methods in new residences. Air conditioning sizing is accomplished by using ACCA's Manual-J procedure by 33% of the respondents, software by 34.4% of the respondents, square-footage by 24.2% and other estimate procedures by about 8.4%. Those using square-footage estimates varied from 350 square-feet- per-ton to 700 square-feet-per-ton. Over a third of respondents indicated oversizing intentionally on some jobs, in order to avoid complaints, accommodate future expansions, enable quicker cooling down of homes, and to allow for lower cooling set …
Daylight Dimming Systems: Studies In Energy Savings And Efficiency, Florida Solar Energy Center, Lynn Schrum
Daylight Dimming Systems: Studies In Energy Savings And Efficiency, Florida Solar Energy Center, Lynn Schrum
FSEC Energy Research Center®
Three studies were conducted at Florida Solar Energy Center (FSEC) to study the lighting energy savings of daylight dimming systems. The Daylighting Test Facility (DTF) was used to study daylight dimming systems and how aperture orientation and blinds affect performance. The energy consumption was compared in two pairs of offices for all four window orientations: north, south, east and west. One office in each pair had blinds in a fixed position (down and open) and the other office had no blinds. The study showed that the energy savings ranged from 24% to 51% depending on the orientation and blinds.
The …
Measured Field Performance And Energy Savings Of Occupancy Sensors: Three Case Studies, Florida Solar Energy Center, David Floyd
Measured Field Performance And Energy Savings Of Occupancy Sensors: Three Case Studies, Florida Solar Energy Center, David Floyd
FSEC Energy Research Center®
Occupancy sensors have the potential to significantly reduce energy use by switching off electrical loads when a normally occupied area is vacated. While occupancy sensors can be used to control a variety of load types, their most popular use has been to control lighting in commercial buildings. Manufacturers claim savings of 15% to 85%, although there is little published research to support the magnitude or timing of reductions. Energy savings and performance are directly related to the total wattage of the load being controlled, effectiveness of the previous control method, occupancy patterns within the space and proper sensor commissioning. In …
Results From A Comprehensive Residential Lighting Retrofit. 09-96, Florida Solar Energy Center, Danny Parker
Results From A Comprehensive Residential Lighting Retrofit. 09-96, Florida Solar Energy Center, Danny Parker
FSEC Energy Research Center®
A single family residence in Miami, Florida was used as a case study to determine how residential lighting energy use could be reduced by substituting energy efficient lamps and fixtures. The three person household was chosen based both on its high utility bills and extensive use of interior lighting. A detailed audit revealed 40 lamps or bulbs on 26 controls (switches) with a total connected load of 2.5 kW.
All major energy using appliances in the home were sub-metered so that lighting and other plug loads could be differenced from the measured total power demand. Also, each of the individual …
Flastar: Florida Alliance For Saving Taxes And Energy Resources. Final Report., Florida Solar Energy Center, John Sherwin
Flastar: Florida Alliance For Saving Taxes And Energy Resources. Final Report., Florida Solar Energy Center, John Sherwin
FSEC Energy Research Center®
This document comprises the final project report in supporting the demonstration of the pilot Florida Public Building Loan Concept. This loan program provides low cost funds to eligible public entities for upgrade of building energy systems. The FLASTAR program (Florida Alliance for Saving Taxes And Resources) was modeled after the successful Texas LoanSTAR project [1, 2]. Within that program, funds provided from oil overcharges are loaned to various facilities for building system retrofits. These loans are repaid (with interest) from energy cost savings. As of the most recent reporting, the LoanSTAR program had saved the State of Texas some $13.7 …
Measured Impacts Of Air Conditioner Condenser Shading, Florida Solar Energy Center, Danny Parker
Measured Impacts Of Air Conditioner Condenser Shading, Florida Solar Energy Center, Danny Parker
FSEC Energy Research Center®
A study has been conducted by the Florida Solar Energy Center (FSEC) to examine if space cooling energy savings can be achieved from shading of residential air conditioning (AC) condenser units. The investigation consisted of before-and-after experiments conducted on three homes over a two year period. A recent EPA study recommends shading of exterior AC condensers, using landscaping or other means, as a method to reduce space cooling energy use (Akbari et al., 1992).
Monitored Energy Use Patterns In Low-Income Housing In A Hot And Humid Climate, Florida Solar Energy Center, Danny Parker
Monitored Energy Use Patterns In Low-Income Housing In A Hot And Humid Climate, Florida Solar Energy Center, Danny Parker
FSEC Energy Research Center®
The Florida Solar Energy Center (FSEC) is metering energy use in two Habitat for Humanity developments. The objective is to understand how energy is used in low income housing and how it can be effectively reduced. The ten "control homes" come from a conventional housing project built by in 1993 Habitat for Humanity in Homestead, Florida. Another ten "experimental homes" have been recruited from the 190 home Jordan Commons development in the same vicinity. These houses, which are soon to be metered, are designed to be energy efficient with high SEER air conditioners, reflective roofing, solar water heaters and energy …
Side-By-Side Testing Of Commercial Office Lighting Systems: Two-Lamp Fluorescent Fixtures, Florida Solar Energy Center, Danny Parker
Side-By-Side Testing Of Commercial Office Lighting Systems: Two-Lamp Fluorescent Fixtures, Florida Solar Energy Center, Danny Parker
FSEC Energy Research Center®
Lighting systems in commercial office buildings are primary determinants of building energy use. In warmer climates, lighting energy use has important implications for building cooling loads as well as those directly associated with illumination tasks. To research the comparative performance of conventional and advanced office lighting systems, Florida Solar Energy Center (FSEC) set up the Lighting Flexible Test Facility (LFTF) which allows side-by-side comparison of lighting options in two otherwise identical 2.7 m x 3.7 m (9' x 12') south facing offices.
The ceiling of the LFTF contains 0.61 m x 1.2 m (2' x 4') recessed fluorescent fixtures designed …
Daylighting Dimming And Energy Savings: The Effects Of Window Orientation And Blinds, Florida Solar Energy Center, Lynn Schrum
Daylighting Dimming And Energy Savings: The Effects Of Window Orientation And Blinds, Florida Solar Energy Center, Lynn Schrum
FSEC Energy Research Center®
The Daylighting Test Facility (DTF) located at Florida Solar Energy Center, was used to study daylight dimming systems and how orientation and blinds effect energy savings. To evaluate the impact of blinds on dimming savings, the energy consumption was compared in two pairs of offices for all four window orientations: north, south, east and west. One office in each pair had blinds in a fixed position (down and open) and the other office had no blinds. From September through December of 1994, data were collected on the north- and south-facing offices. The DTF was rotated 90 degrees and data were …
Uncontrolled Air Flow In Non-Residential Buildings, Florida Solar Energy Center, James Cummings
Uncontrolled Air Flow In Non-Residential Buildings, Florida Solar Energy Center, James Cummings
FSEC Energy Research Center®
The objective of this study was to develop the capability to substantially reduce energy use, building degradation and indoor air pollution caused by uncontrolled air flow in nonresidential buildings. For purposes of the study, 'uncontrolled air flow' was defined as air moving across the building envelope or between zones or components of a building, where the pathways of flow, the direction of flow, and the origin of the air are unknown, unspecified, or unintended. The study comes to three major conclusions as follows: 1. Uncontrolled air flow is pervasive in buildings, often resulting in severe -- and sometimes even catastrophic …
An Interdisciplinary Solar Energy Project, William J. Hutzel
An Interdisciplinary Solar Energy Project, William J. Hutzel
School of Engineering Technology Faculty Publications
An HVAC course, previously offered to students in Mechanical Engineering Technology (MET), has been re-structured to include students in Building Construction Management (BCM). A large project is always an integral part of this course, creating a unique opportunity for collaboration between two distinctly different groups of Technology students. This cooperation is particularly beneficial because MET and BCM graduates frequently cross paths during their professional careers. Many MET graduates operate and service heating, ventilating, and air conditioning equipment that was originally specified and installed by BCM graduates. This paper discusses and evaluates student interactions during a solar …
Energy Efficient Office Building Design For A Hot And Humid Climate: Florida's New Energy Center, Florida Solar Energy Center, Philip W. Fairey
Energy Efficient Office Building Design For A Hot And Humid Climate: Florida's New Energy Center, Florida Solar Energy Center, Philip W. Fairey
FSEC Energy Research Center®
Hot and humid climates, such as those in Florida, pose unique challenges to architects and engineers seeking energy efficient office building designs. The severe impact of internal loads on cooling, the intense solar conditions and the need for increased ventilation set against high relative humidities, all serve to limit the success of many conventional methods of reducing building energy use. To provide a high-visibility demonstration of potential energy design solutions, the Florida Solar Energy Center (FSEC) is building a state-of-the-art office complex for its new facility in Cocoa, Florida.
The Measured Summer Performance Of Tile Roof Systems And Attic Ventilation Strategies In Hot, Humid Climates, Florida Solar Energy Center, David Beal
The Measured Summer Performance Of Tile Roof Systems And Attic Ventilation Strategies In Hot, Humid Climates, Florida Solar Energy Center, David Beal
FSEC Energy Research Center®
During 1994, simultaneous full-scale testing of residential plywood-decked roofing system was conducted using a flexible roof facility (FRF). The facility consists of a 24-ft by 48ft rectangular building with one large conditioned space under an attic that is partitioned into six separate test cells. Throughout the test protocol one cell was configured as a residential black-shingle roof system, employed as the baseline for comparison of the alternative roofing systems.
Two identical cells were employed during the summer of 1994 to investigate soffit and ridge venting. Tests of two different configurations best illustrate the results. A comparison of a sealed attic …
Measured Cooling Energy Savings From Reflective Roofing Systems In Florida: Field And Laboratory Research Results, Florida Solar Energy Center, Danny Parker
Measured Cooling Energy Savings From Reflective Roofing Systems In Florida: Field And Laboratory Research Results, Florida Solar Energy Center, Danny Parker
FSEC Energy Research Center®
A series of field experiments in Florida have examined the impact of reflective roof coatings on air conditioning energy use in occupied homes. The tests were conducted on nine residential buildings from 1991 to 1994 using a before and after protocol where the roofs were whitened at mid-summer. Measured AC electrical savings in the buildings during similar pre- and post-retrofit periods averaged 19%, ranging from a low of 2% to a high of 43%. Utility peak coincident peak savings averaged 22%. Cooling energy reductions appear to depend on ceiling insulation level and roof solar reflectance, air duct system location and …
Indoor Air Quality Impacts Of Uncontrolled Air Flow And Depressurization In Eight Commercial Buildings In Central Florida, Florida Solar Energy Center, James Cummings
Indoor Air Quality Impacts Of Uncontrolled Air Flow And Depressurization In Eight Commercial Buildings In Central Florida, Florida Solar Energy Center, James Cummings
FSEC Energy Research Center®
Field investigations were done in 68 commercial buildings to identify uncontrolled air flows and pressure imbalances. Results from eight buildings (six restaurants and two sports facilities) are reported in this paper. Testing included building airtightness tests, identification of building air barrier location, duct system airtightness, characterization of pressure differentials, building air flow balance, and infiltration/ventilation rates. Six restaurants and one sports facility were found to operate at negative pressures which ranged from -0.003 inWC (-0.8 Pa) to -0.173 inWC (-43 Pa) and averaged -0.051 inWC (-12.7 Pa) under normal operation. A second sports facility operates partially at positive pressure and …
Laboratory Testing Of The Reflectance Properties Of Roofing Materials, Florida Solar Energy Center, Danny Parker
Laboratory Testing Of The Reflectance Properties Of Roofing Materials, Florida Solar Energy Center, Danny Parker
FSEC Energy Research Center®
Past simulation and test cell studies have shown potential reduction to building cooling loads from higher exterior surface solar reflectances (Givoni and Hoffman, 1968; Givoni, 1976; Chuan and Busching, 1983; Griggs and Shipp, 1988; Anderson, 1989; Akbari et al., 1990; Chandra and Moalla, 1991; Bansal et al., 1992). Furthermore, simulation analysis of macro-climatic effects have shown that light colored surfaces may reduce the magnitude of the urban heat island (Taha et al., 1988; Akbari et al, 1989; Akbari et al., 1992).
Figure 1 shows a graphic illustration of the potential influence of surface reflectance on roof solar heat gain. The …
Rebuilding For Efficiency: Improving The Energy Use Of Reconstructed Residences In South Florida, Florida Solar Energy Center, Danny Parker
Rebuilding For Efficiency: Improving The Energy Use Of Reconstructed Residences In South Florida, Florida Solar Energy Center, Danny Parker
FSEC Energy Research Center®
On August 24th, 1992, Hurricane Andrew devastated a large part of South Dade County in Florida. With over 35,000 homes to be rebuilt, there is interest in seeing if these reconstructed residences can be made more energy-efficient.
This report provides a comprehensive assessment of potential energy efficiency improvements for both new and existing homes in South Florida. Over forty energy-efficiency measures were considered in the analysis. Many homes in the effected zone experienced damage to their windows, roofs and the surrounding landscape. As a result, the analysis closely examined options associated with these design aspects. All major end-uses of electricity …
Measured Electricity Savings Of Refrigerator Replacement: Case Study And Analysis, Florida Solar Energy Center, Ted Stedman
Measured Electricity Savings Of Refrigerator Replacement: Case Study And Analysis, Florida Solar Energy Center, Ted Stedman
FSEC Energy Research Center®
There are approximately seven million refrigerator-freezers in the State of Florida. The average demand of these units is at least 1,000 MW. The average life of a residential refrigerator is approximately 20 years (U.S. DOE, 1989). At least 25% of Florida's existing stock are old inefficient units built before the advent of recent appliance efficiency standards. The least efficient are existing models of which approximately 5% of the stock is replaced each year. This represents a significant opportunity for efficiency improvement since recently established standards will greatly improve refrigerator efficiency by 1993 (NAECA, 1987). A number of studies have identified …
Fsec 3.0: Florida Software For Enervironment Computation: V3.0 Draft User's Manual. 01-92, Florida Solar Energy Center, Alp Kerestecioglu
Fsec 3.0: Florida Software For Enervironment Computation: V3.0 Draft User's Manual. 01-92, Florida Solar Energy Center, Alp Kerestecioglu
FSEC Energy Research Center®
FSEC 3.0 was developed to support research. It is a general-purpose software package especially designed to simulate complex building science problems. The program offers several unique features.
The major feature is its ability to solve user-defined systems of governing equations. Up to 250 coupled differential equations and their corresponding boundary conditions may be either selected from libraries or defined by the user. The equations may be linear or nonlinear; spatially-lumped or spatially-distributed; steady-state or transient; ordinary or partial. The structure of the software also allows users to incorporate their own routines or programs. Thus, researchers may define their specific problem …
Measured Natural Cooling Enhancement Of A Whole House Fan, Florida Solar Energy Center, Danny Parker
Measured Natural Cooling Enhancement Of A Whole House Fan, Florida Solar Energy Center, Danny Parker
FSEC Energy Research Center®
An experimental study was carried out in the summer of 1991 to investigate the natural cooling potential of use of a whole house fan in Central Florida's hot and humid climate. The residential building, in Cocoa Beach, FL, is typical of much of the existing housing stock in Florida: a concrete block structure with R-11 ceiling insulation. The building was ventilated with all windows open during the three month summer test period (June-August). Air temperatures and relative humidity inside the home interior along with exterior meteorological conditions (insolation, wind speed, air temperature, relative humidity) were scanned every five seconds with …
Energy Use In Attached And Detached Residential Developments: Survey Results, Florida Solar Energy Center, Robin Vieira
Energy Use In Attached And Detached Residential Developments: Survey Results, Florida Solar Energy Center, Robin Vieira
FSEC Energy Research Center®
The relationship between land use, density, dwelling types and energy use in Florida has never been comprehensively examined. Few people consider both energy used in housing and energy used for local transportation. Florida state officials and some land planners have called for compact urban growth to reduce traffic congestion and travel distances. However, energy is rarely mentioned in these arguments. Local governments are trying to respond to the state's concern for compact growth. Developers, on the other hand, are concerned with meeting the local regulations. Unfortunately, energy use is seldom considered and there is little data available to guide decision …
Investigation Of Air Distribution System Leakage And Its Impacts In Central Florida Homes, Florida Solar Energy Center, James B. Cummings
Investigation Of Air Distribution System Leakage And Its Impacts In Central Florida Homes, Florida Solar Energy Center, James B. Cummings
FSEC Energy Research Center®
Testing for air leakage in air distribution systems was done in 160 central Florida homes. Tracer gas tests found that infiltration rates were three times greater when the air handler was operating that when it was off, indicating that there are large leaks in the air distribution system. Infiltration averaged 0.91 air changes per hour (ach) with the air handler (AH) operating continuously and 0.28 ach with the AH off. Return leaks were measured by tracer gas and found to average 10.7% of AH total flow. House airtightness, in 99 of these homes, determined by blower door testing, averaged 12.7 …
Measuring Thermostat And Air Conditioner Performance In Florida Homes, Florida Solar Energy Center, Hugh Henderson, Jr.
Measuring Thermostat And Air Conditioner Performance In Florida Homes, Florida Solar Energy Center, Hugh Henderson, Jr.
FSEC Energy Research Center®
This report summarizes the experimental results from 30 field tests in 23 Central Florida homes during the Summer of 1990. Detailed thermostat measurements were made at each site for a one to three day period. The purpose of this study was to determine how thermostats operate in actual buildings. This knowledge is necessary to understand the part load performance of air conditioners (ACs).
Impacts Of Duct Leakage On Infiltration Rates, Space Conditioning Energy Use, And Peak Electrical Demand In Florida Homes, Florida Solar Energy Center, James Cummings
Impacts Of Duct Leakage On Infiltration Rates, Space Conditioning Energy Use, And Peak Electrical Demand In Florida Homes, Florida Solar Energy Center, James Cummings
FSEC Energy Research Center®
Testing for duct leakage was done in 91 homes. Tracer gas tests found that infiltration rates were four times greater when the air handler was operating than when it was off. Return leaks were found to average 10.0% of air handler total flow. House airtightness, in 63 of these homes, determined by blower door testing, averaged 12.38 air changes per hour at 50 Pascals (ACH50). When the duct registers were sealed, ACH50 decreased to 10.93, indicating that 11.7% of the house leaks were in the duct system.
Duct repairs were made on 25 homes. Blower door tests found 12.30 air …
A Stratified Air Model For Simulation Of Attic Thermal Performance, Florida Solar Energy Center, Danny Parker
A Stratified Air Model For Simulation Of Attic Thermal Performance, Florida Solar Energy Center, Danny Parker
FSEC Energy Research Center®
An improved computer simulation model for attics has been developed. The model accounts for detailed radiation, buoyancy and wind driven air flows and thermal stratification within the attic airspace. Through comparison with measured data, the paper examines the relative importance of the various modeling parameters and assumptions upon simulation accuracy. Stratification of the attic air was found to be a critical modeling characteristic which is typically ignored in building energy simulations. Both model and measurement results shows that air stratification increases significantly when low-emittance surfaces are included.
Electrical Use, Efficiency, And Peak Demand Of Electric Resistance, Heat Pump, Desuperheater, And Solar Hot Water Systems, Florida Solar Energy Center, Timothy Merrigan
Electrical Use, Efficiency, And Peak Demand Of Electric Resistance, Heat Pump, Desuperheater, And Solar Hot Water Systems, Florida Solar Energy Center, Timothy Merrigan
FSEC Energy Research Center®
Eighty single family residences in Florida were monitored for two years in order to collect data on water heating electrical energy consumption, efficiency, and time-of-day demand. The homes were divided into equally sized samples of four different water heating systems: conventional electric resistance, heat pump, desuperheater and solar hot water systems. Electrical consumption for electric resistance water heaters averaged 8.3 kWh per day in Florida with an average water heating system efficiency of 82%. Desuperheaters used an annual average of 7.4 kWh per day at an annual system efficiency of 110% and heat pump water heaters used 6.1 kWh per …