Open Access. Powered by Scholars. Published by Universities.®

Signal Processing Commons

Open Access. Powered by Scholars. Published by Universities.®

Biomedical Devices and Instrumentation

Institution
Keyword
Publication Year
Publication
Publication Type
File Type

Articles 1 - 30 of 39

Full-Text Articles in Signal Processing

Transcranial Ac Modulation Of Cerebellar Nuclear Activity In Awake Animals, Nuran Kavakli May 2026

Transcranial Ac Modulation Of Cerebellar Nuclear Activity In Awake Animals, Nuran Kavakli

Dissertations

Entrainment of cerebellar nuclear (CN) cells via cerebellar transcranial alternating current stimulation (ctACS) has been reported in animals under ketamine/xylazine anesthesia. Our main objective was to demonstrate modulation of CN activity in unanesthetized, freely moving animals using ctACS. Multi-channel carbon-fiber electrodes were implanted into the interpositus nucleus for recording multi-unit (MU) activity, and thin-film electrodes were implanted subcutaneously over the posterior cerebellum for stimulation. A frequency-domain-based metric was developed to quantify modulation from MU signals. The results demonstrated modulation in a wide range of frequencies (4 Hz-300 Hz) as in anesthetized animals. In contrast, the amplitude of the peak in …


Visualization And Marker-Less Tracking Of User-Defined Pre-Processed Mri Articulator Data Using Deep Learning, Michael De George May 2026

Visualization And Marker-Less Tracking Of User-Defined Pre-Processed Mri Articulator Data Using Deep Learning, Michael De George

Student Theses

This thesis presents a comprehensive framework for the automated tracking and visualization of articulatory movements based on magnetic resonance imaging (MRI) data. A well-known data analysis tool for markerless pose estimation, known as DeepLabCut, is investigated for this purpose. The performance of this tool is enhanced through the design and implementation of a pre-processor. DeepLabCut is a markerless pose estimation toolbox based on deep learning, which overcomes the issue of making manual annotations frame-by-frame. Limitations from manually marking the MRI images are addressed by implementing transfer learning with convolutional neural networks to achieve accurate, user-defined articulator tracking without markers. Current …


Cochlear Electrode Insertion Training Model, Sarah Powell, Kaelyn E. Kraley, Nathan J. Smith Jan 2025

Cochlear Electrode Insertion Training Model, Sarah Powell, Kaelyn E. Kraley, Nathan J. Smith

Williams Honors College, Honors Research Projects

Cochlear implant surgery is a delicate procedure performed by Otolaryngologists (ENTs) to implant an electronic device into the inner ear to provide a sense of sound for people who are profoundly deaf or hard of hearing. The current practices of training involve cadavers and 3D-printed models. Cadavers are commonly used but are expensive, single-use, and do not provide visual and haptic feedback, which are essential for medical students. 3D printed models are less commonly used and are hard to fabricate and not as realistic. If medical students are not properly trained for this delicate procedure, then risks are significantly increased …


Design Of A Portable Fast Scan Cyclic Voltammetry Device Utilizing Pulse Width Modulation For Waveform Generation, Nora Szymkowski Aug 2024

Design Of A Portable Fast Scan Cyclic Voltammetry Device Utilizing Pulse Width Modulation For Waveform Generation, Nora Szymkowski

Masters Theses

Fast Scan Cyclic Voltammetry (FSCV) is a widely used electrochemical technique for real-time measurement of the brain’s chemical messengers, including the molecule dopamine, with high temporal resolution. Currently the financial burden of performing FSCV is quite high, ranging from $8,000 to $20,000+ making the barrier to entry nearly insurmountable for laboratories and classrooms at small institutions. The purpose of this project was to develop a Do-It-Yourself (DIY), portable, and cost-effective FSCV system for use in laboratory and classroom settings. The project aimed to create a compact and cost-effective system that could be used by researchers and educators to study dopamine …


Computer Vision Algorithms For Assessment Of Surgical Suturing Skill Using Hand And Needle Motion, Jianxin Gao Aug 2024

Computer Vision Algorithms For Assessment Of Surgical Suturing Skill Using Hand And Needle Motion, Jianxin Gao

All Dissertations

Surgical suturing skill assessment is a crucial part of surgical education. Vascular surgery educators have developed a simulation-based examination called Fundamentals of Vascular Surgery, which includes a clock-face model for assessing open surgical suturing skills. The clock-face model, however, requires the valuable time of expert surgeons to determine examinees' skills. Moreover, expert surgeons have different judgments for appropriate sutures, which leads to inconsistent grading. These limitations motivate us to use sensors to measure examinees' needle motions and hand motions during the clock-face suturing exercises, and then use the measurements for objective suturing skill assessment.

To assess suturing skills based on …


Shape Memory Alloy Capsule Micropump For Drug Delivery Applications, Youssef Mohamed Kotb Jun 2024

Shape Memory Alloy Capsule Micropump For Drug Delivery Applications, Youssef Mohamed Kotb

Theses and Dissertations

Implantable drug delivery devices have many benefits over traditional drug administration techniques and have attracted a lot of attention in recent years. By delivering the medication directly to the tissue, they enable the use of larger localized concentrations, enhancing the efficacy of the treatment. Passive-release drug delivery systems, one of the various ways to provide medication, are great inventions. However, they cannot dispense the medication on demand since they are nonprogrammable. Therefore, active actuators are more advantageous in delivery applications. Smart material actuators, however, have greatly increased in popularity for manufacturing wearable and implantable micropumps due to their high energy …


2-Channel Eeg Neurofeedback System, Tim Erwin, Donna Nikjou, Sebastian Turkewitz Jun 2024

2-Channel Eeg Neurofeedback System, Tim Erwin, Donna Nikjou, Sebastian Turkewitz

Electrical Engineering

This work describes the design of an EEG-based neurofeedback system which provides users with real-time feedback on their level of focus or relaxation. By analyzing the spectral content of the brain activity measured via scalp electrodes, focus and relaxation levels can be quantified. Based on these measurements, live feedback in the form of moving bar graphs is provided to users, allowing them to gain awareness of their mental-state and more efficiently learn how to consciously relax or focus. This project covers the design of the system, including amplification and filtering stages, digitization, and signal processing. The system interfaces with a …


Database And Machine Learning Model For Classifying Autism Spectrum Disorder From Smartphone Based Electroretinography, Rory Harris May 2024

Database And Machine Learning Model For Classifying Autism Spectrum Disorder From Smartphone Based Electroretinography, Rory Harris

Honors Scholar Theses

Autism Spectrum Disorder (ASD) is a neurodevelopmental disorder that negatively affects a patient’s cognitive and communication aptitude and, therefore, can severely impact that patient’s quality of life. Because of this, early diagnosis is paramount. In recent studies, electroretinography (ERG), which is a measure of the retina’s electrical response to a brief flash of light into the eye, has shown promise in detecting ASD. Access to these scans can provide early diagnosis, improving well-being. Current ERG devices are very expensive due to their on board processing capabilities. This paper aims to create an ERG device using a smartphone as the main …


Towards A Wearable Device For Measuring Impedance Plethysmography Of The Radial Artery, Pritom Chowdhury Apr 2024

Towards A Wearable Device For Measuring Impedance Plethysmography Of The Radial Artery, Pritom Chowdhury

Dartmouth College Master’s Theses

Recent advancements in bioimpedance technology have demonstrated significant promise in the application of cardiac health monitoring. This research explores the design and development of a forearm-based wearable bioimpedance device for non-invasive measurement of heart rate and respiratory rate at an accuracy level comparable to medical-grade monitors. It utilizes a tetrapolar electrode configuration to analyze bioimpedance changes in the radial artery due to blood flow.

An ongoing aspect of this work involves the preliminary development of an embedded framework intended to integrate signal generation, acquisition, and processing within the device to achieve compact and efficient system design, anticipated to contribute to …


Non-Invasive Monitoring Device For Early Detection Of Breast Cancer Related Lymphedema, Amy Prendergast Jan 2024

Non-Invasive Monitoring Device For Early Detection Of Breast Cancer Related Lymphedema, Amy Prendergast

Honors Theses and Capstones

Breast Cancer Related Lymphedema (BCRL) is a common co-morbidity in cancer survivors following neoadjuvant therapies such as chemotherapy, radiation, and/or surgery. It is brought about by the disruption in the lymphatic system (think lymph node biopsy) that leads to a buildup of lymphatic fluid in the arm. Current diagnostic strategies for this condition are merely retroactive, and fairly limited in the parameters that are examined to ensure patient well-being long term. We hypothesize that with an approach that mimics bioimpedance spectroscopy analysis, we will be able to provide a clinical support tool that would better determine early stages of lymphedema …


A Novel Brain Computer Interface Design, Steven Vogan Aug 2023

A Novel Brain Computer Interface Design, Steven Vogan

Senior Honors Theses

A brain computer interface (BCI) is a system which connects neural signals to a computer system. They have been used for controlling systems including robotics, on-screen computer control such as mouse movement, typing, and synthesizing audio signals. Invasive, or implanted, systems are often long-term medical solutions, or used for research where very clear signal is required. Non-invasive systems usually rely on exterior signals gathered through a headset using one or more electrode sensors. These signals are composed of sums of neuron activation potentials from brain activity and can be used to determine particular aspects of brain function. All BCIs rely …


Characterization And Estimation Of Musculoskeletal Pain Using Machine Learning, Boluwatife Faremi Jul 2023

Characterization And Estimation Of Musculoskeletal Pain Using Machine Learning, Boluwatife Faremi

Master's Theses

Traditional scales utilized for recording pain are known to be highly subjective and biased due to inaccuracies in recollecting actual pain intensities. As a result, machine learning (ML) models that are trained using these scores as ground truth are reported to have low performance for objective pain classification because of the huge disparity between what was felt in moments of pain and the scores recorded afterward.

In the present study, two devices were designed for gathering real-time, continuous in-session subjective pain scores and the recording of the autonomic nervous system (ANS) altered endodermal (EDA) activity. 24 participants were recruited to …


Small-Separation Speckle Contrast Optical Spectroscopy For Intraoperative Assessment Of Parathyroid Glands Viability During Thyroid Surgery, Connor Berger Dec 2022

Small-Separation Speckle Contrast Optical Spectroscopy For Intraoperative Assessment Of Parathyroid Glands Viability During Thyroid Surgery, Connor Berger

Symposium of Student Scholars

The parathyroid glands (PTGs) are often damaged during thyroid surgeries due to a lack of methods identifying PTGs and assessing their viability. Damage to PTGs can cause hypocalcemia, a deficiency of calcium in the body. This complication can lead to detrimental consequences with economic burden. The surgeon’s current method of viability assessment is qualitative and subjective. Our technical solution is to employ an optical technique called speckle contrast optical spectroscopy (SCOS) that noninvasively quantifies the blood flow index (Db) of biological tissues at deep tissue levels (>1cm). The goal of this project is to verify SCOS at small source-detector-separation …


Predicting Insulin Pump Therapy Settings, Riccardo L. Ferraro, David Grijalva, Alex Trahan Sep 2022

Predicting Insulin Pump Therapy Settings, Riccardo L. Ferraro, David Grijalva, Alex Trahan

SMU Data Science Review

Millions of people live with diabetes worldwide [7]. To mitigate some of the many symptoms associated with diabetes, an estimated 350,000 people in the United States rely on insulin pumps [17]. For many of these people, how effectively their insulin pump performs is the difference between sleeping through the night and a life threatening emergency treatment at a hospital. Three programmed insulin pump therapy settings governing effective insulin pump function are: Basal Rate (BR), Insulin Sensitivity Factor (ISF), and Carbohydrate Ratio (ICR). For many people using insulin pumps, these therapy settings are often not correct, given their physiological needs. While …


Error Prevention In Sensors And Sensor Systems, Pedro J. Chacon Dominguez May 2021

Error Prevention In Sensors And Sensor Systems, Pedro J. Chacon Dominguez

LSU Doctoral Dissertations

Achievements in all fields of engineering and fabrication methods have led towards optimization and integration of multiple sensing devices into a concise system. These advances have caused significant innovation in various commercial, industrial, and research efforts. Integrations of subsystems have important applications for sensor systems in particular. The need for reporting and real time awareness of a device’s condition and surroundings have led to sensor systems being implemented in a wide variety of fields. From environmental sensors for agriculture, to object characterization and biomedical sensing, the application for sensor systems has impacted all modern facets of innovation. With these innovations, …


Design And Control Of A Peristaltic Pump To Simulate Left Atrial Pressure In A Conductive Silicone Model, Jeremy Collins May 2021

Design And Control Of A Peristaltic Pump To Simulate Left Atrial Pressure In A Conductive Silicone Model, Jeremy Collins

Mechanical Engineering Undergraduate Honors Theses

According to the CDC, atrial fibrillation is responsible for more than 454,000 hospitalizations and approximately 158,000 deaths per year. A common treatment for atrial fibrillation is catheter ablation, a process in which a long flexible tube is guided through the femoral artery and to the source of arrhythmia in the heart, where it measures the electrical potential at various locations and converts problematic heart tissue to scar tissue via ablation. This paper details the design and control of a low-cost ($400) peristaltic pump system using repetitive control to replicate blood pressure in the left atrium in a conductive silicone model …


Novel Tools For Analysis Of Disordered Sleep And Motor Behavior In Preclinical Models Of Disease, Dillon M. Huffman Jan 2021

Novel Tools For Analysis Of Disordered Sleep And Motor Behavior In Preclinical Models Of Disease, Dillon M. Huffman

Theses and Dissertations--Biomedical Engineering

Subtle changes in sleep architecture can accompany and be symptomatic of various diseases or disorders. Understanding the complex interactions between sleep and health requires the ability to characterize sleep, probe its underlying mechanisms through perturbation, and quantify dependent physiological outcomes. Rodent models have come to be accepted as a valuable tool for preclinical investigations. However, experimental tools to accomplish such research typically rely on laborious methods that limit throughput and flexibility. Thus, research tools that minimize workload could be of great value to the research community and expedite investigation of the underlying mechanisms of sleep and further the development of …


Improve The Prototype Of Low-Cost Near-Infrared Diffuse Optical Imaging System, Chen Xu, Mohammed Z. Shakil Dec 2020

Improve The Prototype Of Low-Cost Near-Infrared Diffuse Optical Imaging System, Chen Xu, Mohammed Z. Shakil

Publications and Research

Diffuse Optical Tomography (DOT) and Optical Spectroscopy using near-infrared (NIR) diffused light has demonstrated great potential for the initial diagnosis of tumors and in the assessment of tumor vasculature response to neoadjuvant chemotherapy. The aims of this project are 1) to test the different types of LEDs in the near-infrared range, and design the driving circuit, and test the modulation of LEDs at different frequencies; 2) to test the APDs as a detector, and build the receiver system and compare efficiency with pre-built systems. In this project, we are focusing on creating a low-cost infrared transmission system for tumor and …


Detection Of Standing And Sitting Variations Based On In-Socket Piezoelectric Sensors For Transfemoral Amputees, Alnusairi Tawfik Yahya Aug 2020

Detection Of Standing And Sitting Variations Based On In-Socket Piezoelectric Sensors For Transfemoral Amputees, Alnusairi Tawfik Yahya

Student Works (2020-2029)

A transfemoral prosthesis is required to assist amputees to perform activities of daily living (ADL). The purely mechanical or passive prosthesis has some drawbacks such as consumption of high metabolic energy and limitations in mimicking normal dynamics and kinematics of gait pattern. In contrast, the active prosthesis offers better performance and consumes less metabolic energy. However, recent active prosthesis uses surface electromyography as its sensory system which requires massive preparation work, causes sores to the patient by its electrodes and requires a lot of computation to extract meaningful features. This thesis focuses on developing signal conditioning circuitry to classify six …


Heel Down And Toe-Off Time Measured With Ultrasonic Doppler System And Force Plate Sensor, Sabin Timsina May 2020

Heel Down And Toe-Off Time Measured With Ultrasonic Doppler System And Force Plate Sensor, Sabin Timsina

Honors Theses

Collie Box is a medical device that measures the gait parameters of the person walk- ing in front of it. This device uses the Ultrasonic Doppler system to extract the heel-contact and toe-off times of a person walking within the range of 2-10 meters. These times are used to determine the leg’s swing phase and double stance times. The ultrasonic transducer of 10mm diameter is driven at 40kHz. At the time of the heel-contact and toe-off, foot velocity is zero while the torso part of the human body is still in motion. The wide directivity of 10mm diameter ultrasonic transducer …


Paper-Based Flexible Electrode Using Chemically-Modified Graphene And Functionalized Multiwalled Carbon Nanotube Composites For Electrophysiological Signal Sensing, Md Faruk Hossain, Jae Sang Heo, John Nelson, Insoo Kim Oct 2019

Paper-Based Flexible Electrode Using Chemically-Modified Graphene And Functionalized Multiwalled Carbon Nanotube Composites For Electrophysiological Signal Sensing, Md Faruk Hossain, Jae Sang Heo, John Nelson, Insoo Kim

Bioelectrics Publications

Flexible paper-based physiological sensor electrodes were developed using chemically-modified graphene (CG) and carboxylic-functionalized multiwalled carbon nanotube composites (f@MWCNTs). A solvothermal process with additional treatment was conducted to synthesize CG and f@MWCNTs to make CG-f@MWCNT composites. The composite was sonicated in an appropriate solvent to make a uniform suspension, and then it was drop cast on a nylon membrane in a vacuum filter. A number of batches (0%~35% f@MWCNTs) were prepared to investigate the performance of the physical characteristics. The 25% f@MWCNT-loaded composite showed the best adhesion on the paper substrate. The surface topography and chemical bonding of the proposed CG-f@MWCNT …


Development Of A Myoelectric Detection Circuit Platform For Computer Interface Applications, Nickolas Andrew Butler Mar 2019

Development Of A Myoelectric Detection Circuit Platform For Computer Interface Applications, Nickolas Andrew Butler

Master's Theses

Personal computers and portable electronics continue to rapidly advance and integrate into our lives as tools that facilitate efficient communication and interaction with the outside world. Now with a multitude of different devices available, personal computers are accessible to a wider audience than ever before. To continue to expand and reach new users, novel user interface technologies have been developed, such as touch input and gyroscopic motion, in which enhanced control fidelity can be achieved. For users with limited-to-no use of their hands, or for those who seek additional means to intuitively use and command a computer, novel sensory systems …


Gui For Mri-Compatible Neural Stimulator And Recorder, Soo Han Soon, Nishant Babaria, Ranajay Mandal, Zhongming Liu Aug 2017

Gui For Mri-Compatible Neural Stimulator And Recorder, Soo Han Soon, Nishant Babaria, Ranajay Mandal, Zhongming Liu

The Summer Undergraduate Research Fellowship (SURF) Symposium

Functional magnetic resonance imaging (fMRI) and electroencephalography (EEG) are useful tools to analyze brain activities given active stimulation. However, the electromagnetic noise from the MRI distorts the brain signal recording and damages the subject with excessive heat generated on the electrodes attached to the skin. MRI-compatible recording and stimulation systems previously developed at LIBI lab were capable of removing the electromagnetic noise during the imaging process. Previously, the hardware systems had required the integrative software that could control both circuits simultaneously and enable users to easily change recording and stimulation parameters. Graphical user interface (GUI) programmed with computer language informed …


Psychophysiological Analysis Of A Pedagogical Agent And Robotic Peer For Individuals With Autism Spectrum Disorders., Mohammad Nasser Saadatzi Dec 2016

Psychophysiological Analysis Of A Pedagogical Agent And Robotic Peer For Individuals With Autism Spectrum Disorders., Mohammad Nasser Saadatzi

Electronic Theses and Dissertations

Autism spectrum disorder (ASD) is a neurodevelopmental disorder characterized by ongoing problems in social interaction and communication, and engagement in repetitive behaviors. According to Centers for Disease Control and Prevention, an estimated 1 in 68 children in the United States has ASD. Mounting evidence shows that many of these individuals display an interest in social interaction with computers and robots and, in general, feel comfortable spending time in such environments. It is known that the subtlety and unpredictability of people’s social behavior are intimidating and confusing for many individuals with ASD. Computerized learning environments and robots, however, prepare a predictable, …


Analysis Of Vocal Fold Kinematics Using High Speed Video, Harikrishnan Unnikrishnan Jan 2016

Analysis Of Vocal Fold Kinematics Using High Speed Video, Harikrishnan Unnikrishnan

Theses and Dissertations--Electrical and Computer Engineering

Vocal folds are the twin in-folding of the mucous membrane stretched horizontally across the larynx. They vibrate modulating the constant air flow initiated from the lungs. The pulsating pressure wave blowing through the glottis is thus the source for voiced speech production. Study of vocal fold dynamics during voicing are critical for the treatment of voice pathologies. Since the vocal folds move at 100 - 350 cycles per second, their visual inspection is currently done by strobosocopy which merges information from multiple cycles to present an apparent motion. High Speed Digital Laryngeal Imaging(HSDLI) with a temporal resolution of up to …


Quantification Of Blood Flow Velocity Using Color Sensing, Aditya Deepak Sanghani Oct 2015

Quantification Of Blood Flow Velocity Using Color Sensing, Aditya Deepak Sanghani

Master's Theses

Blood flow velocity is an important parameter that can give information on several pathologies including atherosclerosis, glaucoma, Raynaud’s phenomenon, and ischemic stroke [2,5,6,10]. Present techniques of measuring blood flow velocity involve expensive procedures such as Doppler echocardiography, Doppler ultrasound, and magnetic resonance imaging [11,12]. They cost from $8500-$20000. It is desired to find a low-cost yet equally effective solution for measuring blood flow velocity. This thesis has a goal of creating a proof of concept device for measuring blood flow velocity.

Finger blood flow velocity is investigated in this project. The close proximity to the skin of the finger’s arteries …


Design, Characterization And Application Of A Multiple Input Stethoscope Apparatus, Spencer Geng Wong Aug 2014

Design, Characterization And Application Of A Multiple Input Stethoscope Apparatus, Spencer Geng Wong

Master's Theses

For this project, the design, implementation, characterization, calibration and possible applications of a multiple transducer stethoscope apparatus were investigated. The multi-transducer sensor array design consists of five standard stethoscope diaphragms mounted to a rigid frame for a-priori knowledge of their relative spatial locations in the x-y plane, with compliant z-direction positioning to ensure good contact and pressure against the subject’s skin for reliable acoustic coupling. When this apparatus is properly placed on the body, it can digitally capture the same important body sounds investigated with standard acoustic stethoscopes; especially heart sounds. Acoustic signal inputs from each diaphragm are converted to …


Independent Component Analysis Enhancements For Source Separation In Immersive Audio Environments, Yue Zhao Jan 2013

Independent Component Analysis Enhancements For Source Separation In Immersive Audio Environments, Yue Zhao

Theses and Dissertations--Electrical and Computer Engineering

In immersive audio environments with distributed microphones, Independent Component Analysis (ICA) can be applied to uncover signals from a mixture of other signals and noise, such as in a cocktail party recording. ICA algorithms have been developed for instantaneous source mixtures and convolutional source mixtures. While ICA for instantaneous mixtures works when no delays exist between the signals in each mixture, distributed microphone recordings typically result various delays of the signals over the recorded channels. The convolutive ICA algorithm should account for delays; however, it requires many parameters to be set and often has stability issues. This thesis introduces the …


The Presence Of Regional Accents In Electrolarynx Speech And The Resultant Effect On Overall Intelligibility., Brian Madden, Eugene Coyle Apr 2012

The Presence Of Regional Accents In Electrolarynx Speech And The Resultant Effect On Overall Intelligibility., Brian Madden, Eugene Coyle

Conference Papers

During voiced speech, the larynx provides quasi-periodic acoustic excitation of the vocal tract. In most electrolarynxes, mechanical vibrations are produced by a linear electromechanical actuator, the armature of which percusses against a metal or plastic plate at a frequency within the range of glottal excitation. In this paper, a phonological analysis of a section of results from an online perceptual intelligibility test was performed which compared speech produced using a novel hands-free electrolarynx and a commercially available electrolarynx. A portion of the test consisted of a closed-set format containing a selection of four sets of four random CVC audio samples …


Intelligibility Of Electrolarynx Speech Using A Novel Hands-Free Actuator, Brian Madden, Mark Nolan, Ted Burke, James Condron, Eugene Coyle Jan 2011

Intelligibility Of Electrolarynx Speech Using A Novel Hands-Free Actuator, Brian Madden, Mark Nolan, Ted Burke, James Condron, Eugene Coyle

Conference Papers

During voiced speech, the larynx provides quasi-periodic acoustic excitation of the vocal tract. In most electrolarynxes, mechanical vibrations are produced by a linear electromechanical actuator, the armature of which percusses against a metal or plastic plate at a frequency within the range of glottal excitation. In this paper, the intelligibility of speech produced using a novel hands-free actuator is compared to speech produced using a conventional electrolarynx. Two able-bodied speakers (one male, one female) performed a closed response test containing 28 monosyllabic words, once using a conventional electrolarynx and a second time using the novel design. The resulting audio recordings …