Open Access. Powered by Scholars. Published by Universities.®

Power and Energy Commons™

Open Access. Powered by Scholars. Published by Universities.®

2010

Discipline
Institution
Keyword
Publication
Publication Type

Articles 61 - 90 of 122

Full-Text Articles in Power and Energy

Fabrication Of Electrochemically Activated Glassy Carbon/Bismuth Film Electrodes For Sensitive Analysis Of Pb(2+) And Cd(2+), Kang Shi, Wen-Jing Wang, Kun Hu May 2010

Fabrication Of Electrochemically Activated Glassy Carbon/Bismuth Film Electrodes For Sensitive Analysis Of Pb(2+) And Cd(2+), Kang Shi, Wen-Jing Wang, Kun Hu

Journal of Electrochemistry

The application of electrochemically activated glassy carbon (GC) in the in-situ preparing of bismuth film electrodes (BiFEs) to analyze Pb2 + and Cd2 + was investigated. The glassy carbon electrodes were electrochemically activated by either potentiostic or cyclic polarization in 1 mol·L-1 NaOH solution. Experimental results show that employment of HCl solution as the analytical solution not only can reproducibly renew the electrochemically activated GC electrode surface with an electrochemical clear procedure, but also can greatly enhance the sensitivity of BiFes method for analysis of Pb2 + and Cd2 +. The test range thus …


Synthesis Of Cosalen Composite In Apo-5 And Its Electrocatalytic Behaviour For Reaction Of Dioxygen Reduction, Rong Zhang, Li-Hua Tang, Bin-Bin Fan, Jing-Hong Ma, Rui-Feng Li May 2010

Synthesis Of Cosalen Composite In Apo-5 And Its Electrocatalytic Behaviour For Reaction Of Dioxygen Reduction, Rong Zhang, Li-Hua Tang, Bin-Bin Fan, Jing-Hong Ma, Rui-Feng Li

Journal of Electrochemistry

CoAPO-5 molecular sieve was hydrothermally synthesized. The Cobalt ions in CoAPO-5 were coordinated with the SALEN ligend diffusing into the channels of the molecular sieve to form CoSALEN complexes. The electrochemical behaviors and electrocatalysis for dioxygen reduction of the CoSALEN complex immobilized in APO-5 modified glassy carbon electrodes (GCEs) have been investigated by cyclic voltammetry (CV) and chronoamperometry (CA) in differrent pH aqueous solutions. The results showed that the PS/CoSALEN/APO-5 /GC modified electrode is of the high electrocatalytic activity towards dioxygen reduction in pH 6. 86 buffer solution with a reduced overpotential of 447 mV lower than bare GC electrode. …


Failure Reaction Mechanism Of Internal Short-Circuit For Lithium-Ion Batteries, He Li, Shen-Jun Yu, Zhi-Kui Chen, Guang-Chuan Liang May 2010

Failure Reaction Mechanism Of Internal Short-Circuit For Lithium-Ion Batteries, He Li, Shen-Jun Yu, Zhi-Kui Chen, Guang-Chuan Liang

Journal of Electrochemistry

In this work, the battery impact testing machine has been used to study the failure progress of internal short-circuit (ISC) for lithium ion batteries. The reaction mechanisms between cathode/anode and electrolyte in the battery at different temperatures were characterized by differential scanning calorimetry (DSC), gas chromatography/mass spectrometry (GC/MS) and X-ray diffraction (XRD). The experimental results show that the ISC failure of the battery was mainly due to the reaction between cathode Li0.5CoO2 and electrolyte. The decomposition and oxygen evolution reactions of cathode occurred when the temperature reached a certain value. At the same time a fierce oxidation …


Influence Of Ions Dimension On The Electric Field Activation Of Micro-Crystallite Carbon, Gang-Wei Sun, Wen-Hua Song, Guo Cheng, Wen-Ming Qiao, Li-Cheng Ling May 2010

Influence Of Ions Dimension On The Electric Field Activation Of Micro-Crystallite Carbon, Gang-Wei Sun, Wen-Hua Song, Guo Cheng, Wen-Ming Qiao, Li-Cheng Ling

Journal of Electrochemistry

Micro-crystallite carbon (CC) was synthesized by KOH activation of carbonized petroleum coke precursors. The porous properties structure and crystallite structure were characterized by N2 adsorption-desorption, X-ray diffraction (XRD) measurements. The capacitive behavior of CC was investigated in the electrolyte of Et4NBF4/PC, Et4NBF4/AN, Bu4NBF4/PC and Bu4NBF4/AN, respectively. Results showed that the lower potential of electric field activation (EFA) was obtained in the solvent of AN than in PC, which was ascribed to the fact that smaller solvated ions dimension in AN facilitating the intercalation …


Hydrogen Evolution Reaction Activtity Of Ni-Ru-Ir Oxide Cathode Coating, Yin-Hui Fu, Xue-Ming Li, Wu-Lin Li, Jun Zhang May 2010

Hydrogen Evolution Reaction Activtity Of Ni-Ru-Ir Oxide Cathode Coating, Yin-Hui Fu, Xue-Ming Li, Wu-Lin Li, Jun Zhang

Journal of Electrochemistry

The Ni-Ru-Ir electrode coating was fabricated by thermal decomposition and oxidation. Electrochemical properties of Ni-Ru-Ir electrode coating and pure nickel cathode in the 30% NaOH solutions at 90 ℃(conditions of the industrial electrolysis) ,have been investigated by cyclic voltammetry,Tafel curves and chronoamperometry. The results show that the Ni-Ru-Ir oxide electrode coating exhibited high catalytic activity. At the current density of 0. 3 A·cm-2,the lowest hydrogen evolution overpotential of Ni-Ru-Ir oxide electrode coating was about 300 mV lower than Ni. The roughness and excharge current density of Ni-Ru-Ir electrode coating were 32 and 4 times,respectively,larger than those of pure …


Synthesis And Electrochemical Properties Of Li3V2(Po4)3/C Cathode Materials For Lithium Ion Battery, Li-Ying Liu, Hai-Yan Zhang, Lian Chen, Yu-Chun Zhai May 2010

Synthesis And Electrochemical Properties Of Li3V2(Po4)3/C Cathode Materials For Lithium Ion Battery, Li-Ying Liu, Hai-Yan Zhang, Lian Chen, Yu-Chun Zhai

Journal of Electrochemistry

Cathode material Li3V2(PO4) 3 /C for Lithium-ion battery was synthesized by combination of ball milling and baking. Physical and electrochemical performances of as-prepared materials were characterized through XRD,EIS and galvanostatic cell cycling. The results show that the products were monoclinic Li3 V2 (PO4) 3 with well-developed crystal structure. At 0. 1C,0. 25C and 0. 5C,the initial discharge capacities were 150. 6,134. 1 and 107. 1 mAh·g-1 ,respectively. Capacity retention rates were 87. 3% after 130 cycles at 0. 25C and 87. 2% after 105 cycles at 0. 5C. Charge-discharge …


Nano-Sized Au On Nickel Foam As Cathode Of Alkaline Al-H2O2 Semi Fuel Cell, Shu-Li Chen, Bang-An Lu, Yao Liu, Gui-Ling Wang, Dian-Xue Cao May 2010

Nano-Sized Au On Nickel Foam As Cathode Of Alkaline Al-H2O2 Semi Fuel Cell, Shu-Li Chen, Bang-An Lu, Yao Liu, Gui-Ling Wang, Dian-Xue Cao

Journal of Electrochemistry

Nano-sized Au particles were deposited on a nickel foam substrate by a fast spontaneous deposition method using AuCl3 as the source of Au. The effects of AuCl3 concentration and deposition time on the size and distribution of Au particles,and the performance of the obtained Au/Ni electrode as the cathode of Al-H2O2 semi fuel cell were investigated. It was found that after the nickel foam was immersed in a 2 mmol·L-1 AuCl3 solution for 60 s,Au particles with diameters smaller than 100 nm were deposited on its surfaces and cover the surface completely. The …


2010 Spring Engr333 Project Final Report, Eric Ledy, Rachel Jelgerhuis, Jasper Gondhi, Michael Gondhi, Steve Brink, John Mantel, Kyle Harvey, Jim Vanleeuwen, Jacob Speelman, Mitch Brummel, Tyler Van Dongen, Nathan Van Heukelum, Lynette Hromada, Jen Meneely, Matthew Brouwer, Marc Eberlein, Steve Demaagd, Tim Opperwall, Andrew Dejong, Joel Love, Alex Boelkins, Amanda Hollinger, Betsy Huyser, Jason Dornbos, Jason Handlogten, Justin Karsten, Matt Milan May 2010

2010 Spring Engr333 Project Final Report, Eric Ledy, Rachel Jelgerhuis, Jasper Gondhi, Michael Gondhi, Steve Brink, John Mantel, Kyle Harvey, Jim Vanleeuwen, Jacob Speelman, Mitch Brummel, Tyler Van Dongen, Nathan Van Heukelum, Lynette Hromada, Jen Meneely, Matthew Brouwer, Marc Eberlein, Steve Demaagd, Tim Opperwall, Andrew Dejong, Joel Love, Alex Boelkins, Amanda Hollinger, Betsy Huyser, Jason Dornbos, Jason Handlogten, Justin Karsten, Matt Milan

ENGR 333

Calvin is developing plans for a new data center to provide business continuity and quick recovery in the event of a disaster. The new data center will not replace the existing data center; rather, it will provide redundancy for the operations of the campus. Because of the energy demands of data centers, there is a worldwide push for energy efficiency. So-called “green data centers” provide the same functionality as a normal data center with reduced energy usage and reduced energy costs. Calvin, like most organizations, must weigh the long-term economic benefits of energy efficiency projects against higher initial cost. The …


2010 Spring Engr333 Poster 1, Eric Ledy, Rachel Jelgerhuis, Jasper Gondhi, Michael Gondhi, Steve Brink, John Mantel, Kyle Harvey, Jim Venleeuwen, Jacob Speelman, Mitch Brummel, Tyler Van Dongen, Nathan Van Heukelum, Lynette Hromada, Jen Meneely, Matthew Brouwer, Marc Eberlein, Steve Demaagd, Tim Opperwall, Andrew Dejong, Joel Love, Alex Boelkins, Amanda Hollinger, Betsy Huyser, Jason Dornbos, Jason Handlogten, Justin Karsten, Matt Milan May 2010

2010 Spring Engr333 Poster 1, Eric Ledy, Rachel Jelgerhuis, Jasper Gondhi, Michael Gondhi, Steve Brink, John Mantel, Kyle Harvey, Jim Venleeuwen, Jacob Speelman, Mitch Brummel, Tyler Van Dongen, Nathan Van Heukelum, Lynette Hromada, Jen Meneely, Matthew Brouwer, Marc Eberlein, Steve Demaagd, Tim Opperwall, Andrew Dejong, Joel Love, Alex Boelkins, Amanda Hollinger, Betsy Huyser, Jason Dornbos, Jason Handlogten, Justin Karsten, Matt Milan

ENGR 333

Calvin is developing plans for a new data center to provide business continuity and quick recovery in the event of a disaster. The new data center will not replace the existing data center; rather, it will provide redundancy for the operations of the campus. This new data center will be placed in the Spoelhof Complex. Because of the energy demands of data centers, there is a worldwide push for energy efficiency. So-called “green data centers” provide the same functionality as a normal data center with reduced energy usage and reduced energy costs. Calvin, like most organizations, must weigh the long-term …


2010 Spring Engr333 Poster 2, Eric Ledy, Rachel Jelgerhuis, Jasper Gondhi, Michael Gondhi, Steve Brink, John Mantel, Kyle Harvey, Jim Vanleeuwen, Jacob Speelman, Mitch Brummel, Tyler Van Dongen, Nathan Van Heukelum, Lynette Hromada, Jen Meneely, Matthew Brouwer, Marc Eberlein, Steve Demaagd, Tim Opperwall, Andrew Dejong, Joel Love, Alex Boelkins, Amanda Hollinger, Betsy Huyser, Jason Dornbos, Jason Handlogten, Justin Karsten, Matt Milan May 2010

2010 Spring Engr333 Poster 2, Eric Ledy, Rachel Jelgerhuis, Jasper Gondhi, Michael Gondhi, Steve Brink, John Mantel, Kyle Harvey, Jim Vanleeuwen, Jacob Speelman, Mitch Brummel, Tyler Van Dongen, Nathan Van Heukelum, Lynette Hromada, Jen Meneely, Matthew Brouwer, Marc Eberlein, Steve Demaagd, Tim Opperwall, Andrew Dejong, Joel Love, Alex Boelkins, Amanda Hollinger, Betsy Huyser, Jason Dornbos, Jason Handlogten, Justin Karsten, Matt Milan

ENGR 333

The new redundant data center requires that Network Operations Center personnel are able to monitor certain conditions within the data center for the safety of the server equipment. Server equipment will fail if it gets too hot or if the surrounding environment becomes too humid, therefore the baseline instrumentation design must monitor both temperature and humidity in the data center. The system must also be capable of remotely alerting NOC personnel when there is a problem.


2010 Spring Engr333 Project Seminar Presentation, Eric Ledy, Rachel Jelgerhuis, Jasper Gondhi, Michael Gondhi, Steve Brink, John Mantel, Kyle Harvey, Jim Vanleeuwen, Jacob Speelman, Mitch Brummel, Tyler Van Dongen, Nathan Van Heukelum, Lynette Hromada, Jen Meneely, Matthew Brouwer, Marc Eberlein, Steve Demaagd, Tim Opperwall, Andrew Dejong, Joel Love, Alex Boelkins, Amanda Hollinger, Betsy Huyser, Jason Dornbos, Jason Handlogten, Justin Karsten, Matt Milan Apr 2010

2010 Spring Engr333 Project Seminar Presentation, Eric Ledy, Rachel Jelgerhuis, Jasper Gondhi, Michael Gondhi, Steve Brink, John Mantel, Kyle Harvey, Jim Vanleeuwen, Jacob Speelman, Mitch Brummel, Tyler Van Dongen, Nathan Van Heukelum, Lynette Hromada, Jen Meneely, Matthew Brouwer, Marc Eberlein, Steve Demaagd, Tim Opperwall, Andrew Dejong, Joel Love, Alex Boelkins, Amanda Hollinger, Betsy Huyser, Jason Dornbos, Jason Handlogten, Justin Karsten, Matt Milan

ENGR 333

File for student presentation, given by students in the Spring 2010 class of ENGR333.


Maintenance Optimization For Substations With Aging Equipment, Haifeng Ge Apr 2010

Maintenance Optimization For Substations With Aging Equipment, Haifeng Ge

Department of Electrical and Computer Engineering: Dissertations, Theses, and Student Research

Today’s electric utilities are confronted with a myriad of challenges that include aging infrastructure, enhanced expectation of reliability, reduced cost, and coping effectively with uncertainties and changing regulation requirements. Utilities rely on Asset Management programs to manage inspections and maintenance activities in order to control equipment conditions. However, development of strategies to make sound decisions in order to effectively improve equipment and system reliability while meeting constraints such as a maintenance budget is a challenge.

The primary objective of this dissertation is to develop models and algorithms to study the impact of maintenance toward equipment/system reliability and economic cost, and …


Wave Energy Converter Performance Modeling And Cost Of Electricity Assessment, Dmitri Jarocki Apr 2010

Wave Energy Converter Performance Modeling And Cost Of Electricity Assessment, Dmitri Jarocki

Master's Theses

California is experiencing a rapid increase in interest for the potential of converting ocean waves into clean electricity. Numerous applications have been submitted for the permitting of such renewable energy projects; however the profitability, practicability, and survivability have yet to be proven. Wave energy conversion technology has steadily matured since its naissance in the 1970’s, several wave energy power installations currently exist, and numerous plans for commercial power plant are in the works on the shores of multiple continents. This study aims to assess the economic viability of two proposed commercial wave energy power plant projects on the Central California …


Electric Field Computation Of Wet Insulating Surfaces, Bhargavi Sarang Apr 2010

Electric Field Computation Of Wet Insulating Surfaces, Bhargavi Sarang

Electrical & Computer Engineering Theses & Dissertations

High voltage outdoor insulators form the backbone of modem power systems and therefore play a pivotal role in reliable supply of power. The presence of water droplets/films due to rain, fog, etc. enhances the electric field intensity and leads to electrical breakdown subsequently affecting the longevity of the insulator. The magnitude of surface E-fields necessary for initiation of electrical breakdown is a function of water repellent characteristic of an insulator called hydrophobicity. Thus, knowledge of field distribution around water droplets/films at various hydrophobic levels is significant in designing a better insulating material.

The current research analyzed electric field distributions on …


Multilevel Dc-Ac Converter Interface With Solar Panels, Yue Cao Apr 2010

Multilevel Dc-Ac Converter Interface With Solar Panels, Yue Cao

Pursuit - The Journal of Undergraduate Research at The University of Tennessee

This paper presents a single-phase 11-level (5 H-bridge) cascaded multilevel DC-AC converter that has implemented a Phase Locked Loop (PLL) and Maximum Power Point Tracking (MPPT) with 5 separate solar panel DC sources. This topology upgrades the conventional 3-level Pulse Width Modulation (PWM) controlled converter with advantages such as smoother output waveforms, more flexibility in voltage range, smaller filter size, and switching angle control. Simulation results of voltage synchronization using PLL and experimental setup and results implementing the entire converter interface are also presented.


Input-Output Analysis Of Irish Construction Sector Greenhouse Gas Emissions, Adolf Acquaye, Aidan Duffy Apr 2010

Input-Output Analysis Of Irish Construction Sector Greenhouse Gas Emissions, Adolf Acquaye, Aidan Duffy

Articles

Ireland is committed to limiting its greenhouse gas (GHG) emissions to 113% of 1990 levels over the period 2008-12 and to 84% of 2005 levels by 2020 under the Kyoto Agreement and the EU’s ’20 20’ by 2020 respectively. National policies have targeted many industry sectors but have failed to directly tackle GHG emissions associated with construction activity. This paper estimates energy and GHG emissions intensities of the Irish construction sector and subsectors and estimates its contribution to Irish national emissions. This information is used to identify and assess the impacts of policy measures which would result in a reduction …


Projected Costs Of A Grid-Connected Domestic Pv System Under Different Scenarios In Ireland, Using Measured Data From A Trial Installation, Lacour Ayompe, Aidan Duffy, Sarah Mccormack, Michael Conlon Apr 2010

Projected Costs Of A Grid-Connected Domestic Pv System Under Different Scenarios In Ireland, Using Measured Data From A Trial Installation, Lacour Ayompe, Aidan Duffy, Sarah Mccormack, Michael Conlon

Articles

This paper presents results of a study of projected costs for a grid-connected PV system for domestic application in Ireland. The study is based on results from a 1.72kWpPV system installed on a flat rooftop in Dublin, Ireland. During its first year of operation a total of 885.1kWh/kWp of electricity was generated with a performance ratio of 81.5%. The scenarios employed in this study consider: a range of capital costs; cost dynamics based on a PV module learning rate of 2+/-75%; projections for global annual installed PV capacity under an advanced and moderate market growth conditions; domestic electricity cost growth …


Harmonic Distortion State Estimation Using An Evolutionary Strategy, Elcio F. De Arruda, Nelson Kagan, Paulo F. Ribeiro Apr 2010

Harmonic Distortion State Estimation Using An Evolutionary Strategy, Elcio F. De Arruda, Nelson Kagan, Paulo F. Ribeiro

University Faculty Publications and Creative Works

This paper presents a new methodology to estimate harmonic distortions in a power system, based on measurements of a limited number of given sites. The algorithm utilizes evolutionary strategies (ES), a development branch of evolutionary algorithms. The main advantage in using such a technique relies upon its modeling facilities as well as its potential to solve fairly complex problems. The problem-solving algorithm herein proposed makes use of data from various power-quality (PQ) meters, which can either be synchronized by high technology global positioning system devices or by using information from a fundamental frequency load flow. This second approach makes the …


Dc/Dc Converter For A Small Scale Wind Hydrogen System, Joel M. Jacobs Apr 2010

Dc/Dc Converter For A Small Scale Wind Hydrogen System, Joel M. Jacobs

Department of Electrical and Computer Engineering: Dissertations, Theses, and Student Research

An electronic converter is designed for an isolated renewable energy system. In this system, energy produced by a small wind turbine is used to extract hydrogen from water. Unique aspects of this application that affect the performance of the converter will be defined. Design considerations of the individual components will be discussed. Calculations on performance and validation of those calculations are also presented. Lastly, an economic analysis of the produced hydrogen will be performed.


Power Quality In Grid Connected Renewable Energy Systems: Role Of Custom Power Devices, Shafiuzzaman Khan Khadem, Malabika Basu, Michael Conlon Mar 2010

Power Quality In Grid Connected Renewable Energy Systems: Role Of Custom Power Devices, Shafiuzzaman Khan Khadem, Malabika Basu, Michael Conlon

Conference papers

This paper deals with the technical review of power quality problems associated with the renewable based distributed generation systems and how the custom power devices like STATCOM, DVR and UPQC play important role in power quality improvement. IEEE and IEC standard for the grid connected renewable energy systems are one of the critical point of interest for the selection of custom power devices. Special attention has been given on the compensation of reactive power, harmonic current and voltage fluctuation during the interconnected as well as islanding mode of operation. As the solar and wind are the most abundant resources therefore …


The Control Of Rotor Side And Grid Side Converters In A Dfig During Network Voltage Unbalance Conditions Using Resonant Current Controllers., Joseph Kearney, Michael Conlon, Eugene Coyle Mar 2010

The Control Of Rotor Side And Grid Side Converters In A Dfig During Network Voltage Unbalance Conditions Using Resonant Current Controllers., Joseph Kearney, Michael Conlon, Eugene Coyle

Conference papers

This paper implements control techniques to enable improved operation of DFIG’s when subjected to the effects of network voltage unbalance conditions. The control scheme involves the integration of a resonant regulator into the PI controllers of both the rotor side and grid side converters in a DFIG. The resonant controller is tuned to twice the network frequency (2ωe) and designed to mitigate against the oscillations in a DFIG due to network voltage unbalance conditions. The grid side converter controller also incorporates a second resonant controller tuned to three times the grid frequency (3ωe) to alleviate the …


Reputation-Based Trust For A Cooperative, Agent-Based Backup Protection Scheme For Power Networks, John F. Borowski Mar 2010

Reputation-Based Trust For A Cooperative, Agent-Based Backup Protection Scheme For Power Networks, John F. Borowski

Theses and Dissertations

This thesis research explores integrating a reputation-based trust mechanism with an agent-based backup protection system to improve the performance of traditional backup relay methods that are currently in use in power transmission systems. Integrating agent technology into relay protection schemes has been previously proposed to clear faults more rapidly and to add precision by enabling the use of adaptive protection methods. A distributed, cooperative trust system such as that used in peer-to-peer file sharing networks has the potential to add an additional layer of defense in a protection system designed to operate with greater autonomy. This trust component enables agents …


Investigating The Use Of Frequency Selective Surfaces In High Power Microwave Applications, Steven M. Pugh Mar 2010

Investigating The Use Of Frequency Selective Surfaces In High Power Microwave Applications, Steven M. Pugh

Theses and Dissertations

This thesis explores new territory with the theoretical investigation of the use of Frequency Selective Surfaces (FSS) in High Power Microwave (HPM) applications. Work was performed in a simulation environment where rectangular and ring-shaped FSS elements were evaluated. Incident electric field levels of 0.5MV/m were propagated toward the FSS in a plane wave that was perpendicular to the surface. Results show that the total electric field in the apertures of the FSS can reach more than 6MV/m. This necessitates the use of high strength dielectric materials surrounding the FSS to reduce the risk of electrical breakdown. It is shown that …


The Effect Of Synthetic Aperture Radar Image Resolution On Target Discrimination, John E. Mcgowan Mar 2010

The Effect Of Synthetic Aperture Radar Image Resolution On Target Discrimination, John E. Mcgowan

Theses and Dissertations

This research details the effect of spatial resolution on target discrimination in Synthetic Aperture Radar (SAR) images. Multiple SAR image chips containing targets and non-targets are used to test a baseline Automatic Target Recognition (ATR) system with reduced spatial resolution. Spatial resolution is reduced by lowering the pixel count or synthesizing a degraded image by filtering and reducing the pixel count. A two-parameter Constant False Alarm Rate (CFAR) detector is tested, and three feature sets, size, contrast, and texture, are used to train a linear classifier and to estimate probability density functions for the two classes. The results are scored …


Near Real-Time Exercise Machine Power Statistics Reporting, Brendan C. Asche Mar 2010

Near Real-Time Exercise Machine Power Statistics Reporting, Brendan C. Asche

Master's Theses

Cal Poly’s Recreation Center expansion project provides an opportunity to implement Energy Harvesting From Exercise Machines (EHFEM). Part of this implementation is a system that reports the exercise machines’ energy production. Although products capable of reporting exercise machine energy harvesting statistics exist, they have limited capabilities. This thesis project defends a system capable of reporting exercise machine power statistics in near real-time.

The system consists of display, database, and power measurement modules. The display module presents statistics in an interactive, graphical, and widely-accessible way. The database module provides an efficient way of organizing and accessing stored statistics. Multiple power measurement …


Barrier Coatings For Thin Film Solar Cells: Final Subcontract Report, L. C. Olsen Mar 2010

Barrier Coatings For Thin Film Solar Cells: Final Subcontract Report, L. C. Olsen

Publications (E)

This program has involved investigations of the stability of CdTe and copper-indium-gallium-diselenide (CIGS) solar cells under damp heat conditions and effects of barrier coatings. CdTe and CIGS cells were subjected to environmental conditions characterized by 60ºC and 90% relative humidity (60/90), and to some extent 85ºC and 85 % relative humidity (85/85). Barrier coating technology developed at PNNL for OLEDs was used to investigate approaches to encapsulation of the two types of thin film solar cells. Moisture barriers consisting of multi-layer coatings involving alternating layers of polymer and aluminum oxide were deposited directly onto the front surface of CIGS cells …


Novel Ac Side P&O Maximum Power Transfer Control For Grid Connected Photovoltaic Systems, Mohamed Moin Hanif, Malabika Basu, Kevin Gaughan Mar 2010

Novel Ac Side P&O Maximum Power Transfer Control For Grid Connected Photovoltaic Systems, Mohamed Moin Hanif, Malabika Basu, Kevin Gaughan

Conference papers

Grid connected Photovoltaic inverters can convert PV energy into electricity with very high efficiencies. Power from the PV panels fluctuates depending on various weather conditions. PV inverters usually include a maximum power point tracker (MPPT) to track this varying power, in order to transfer all the available power to the grid efficiently. Control of power transferred to the grid along with the MPPT plays a crucial role in determining the efficiency of a PV system. This paper discusses about the basic power transfer theory between sources (PV and Grid) and focuses on the need of a DC-DC boost circuit, along …


Transmission System Construction And Analysis, Siyuan Wang Mar 2010

Transmission System Construction And Analysis, Siyuan Wang

Electrical Engineering

In this project we designed and analyzed a simple power system from scratch using Positive Sequence Load Flow (PSLF) and Computer Aided Protection Engineering (CAPE). PSLF is used to solve the balance transmission system. The simulation results from PSLF prove the proposed methodology numerical accuracy. Short circuit duty is simulated using CAPE to find the fault current each bus can have on the system, so engineers can protect the system with the appropriate protection scheme. This project totals two major loads with a combine MW intake of 450 MW. In order to supply multiple loads with constant power, the system …


Solar Power And The Electric Grid, Energy Analysis, Nrel Energy Analysis Mar 2010

Solar Power And The Electric Grid, Energy Analysis, Nrel Energy Analysis

Publications (E)

In today’s electricity generation system, different resources make different contributions to the electricity grid. This fact sheet illustrates the roles of distributed and centralized renewable energy technologies, particularly solar power, and how they will contribute to the future electricity system. The advantages of a diversified mix of power generation systems are highlighted.


Consortia Focused On Photovoltaic R&D, Manufacturing, And Testing: A Review Of Existing Models And Structures, Charlie Coggeshall, Robert M. Margolis Mar 2010

Consortia Focused On Photovoltaic R&D, Manufacturing, And Testing: A Review Of Existing Models And Structures, Charlie Coggeshall, Robert M. Margolis

Publications (E)

As the U.S. Department of Energy's (DOE's) Solar Energy Technologies Program prepares to initiate a new cost-shared research and development (R&D) effort on photovoltaic (PV) manufacturing, it is useful to review the experience to date with consortia focused on PV R&D, manufacturing, and testing. Information was gathered for this report by conducting interviews and accessing Web sites of 14 U.S. consortia and four European consortia, each with either a primary focus on or an emerging interest in PV technology R&D, manufacturing, or testing. Additional input was collected from several workshops held by the DOE and National Academy of Sciences (NAS) …