Open Access. Powered by Scholars. Published by Universities.®

Structural Engineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 30 of 51

Full-Text Articles in Structural Engineering

Determination Of The Tensile And Shear Strengths Of Screws And The Effect Of Screw Patterns On Cold-Formed Steel Connections, Marc Allen Sokol, Roger A. Laboube, Wei-Wen Yu Dec 1998

Determination Of The Tensile And Shear Strengths Of Screws And The Effect Of Screw Patterns On Cold-Formed Steel Connections, Marc Allen Sokol, Roger A. Laboube, Wei-Wen Yu

CCFSS Library (1939 - present)

PREFACE This report summarizes two studies related to the design of cold-formed steel connections. The study topics included the creation of a test standard for determining the strength of a screw, and the determination of the strength of a screw connection. A standard test protocol does not exist for determining the strength of a screw. Today, manufacturers use test protocols developed for their products. Thus, there is no consistency in defining the structural performance of a screw. A test standard has been developed. The standard used as its model the American Society of Testing and Material's F 606, Standard Test …


Behaviour Of Thin G550 Sheet Steel Screwed Connections, Colin A. Rogers, Gregory J. Hancock Oct 1998

Behaviour Of Thin G550 Sheet Steel Screwed Connections, Colin A. Rogers, Gregory J. Hancock

CCFSS Proceedings of International Specialty Conference on Cold-Formed Steel Structures (1971 - 2018)

This paper provides a summary of results detailing the behaviour of screwed connections tested in shear, which were composed of thin G550 and G300 sheet steels (to the 1993 Australian Standard AS 1397). Recommendations concerning the adequacy of current design standards with respect to the design of thin sheet steel screwed connections are made.


Spacing Of Connections In Compression Flanges Of Built-Up Cold-Formed Steel Beams, Roger A. Laboube, Wei-Wen Yu, Michael L. Jones Oct 1998

Spacing Of Connections In Compression Flanges Of Built-Up Cold-Formed Steel Beams, Roger A. Laboube, Wei-Wen Yu, Michael L. Jones

CCFSS Proceedings of International Specialty Conference on Cold-Formed Steel Structures (1971 - 2018)

Built-up cold-formed steel sections may offer greater economy in building construction. Typical built-up sections are cellular decks or door and window header beams. A research project was initiated to determine if the current spacing criteria outlined in Section D1.2 of the AISI Specification accurately predicted the capacity of built-up sections with the cover plate in compression. This study showed that criteria No.2 of the AISI Design Specification spacing criteria is restrictive when applied to built-up cross sections in bending. All test sections continued to carry additional load after the cover plate buckled. The tests showed that as the spacing of …


Frequently Asked Questions Concerning The Aisi Base Test And The Use Of The Aisi Anchorage Equations, Roger A. Laboube, Thomas M. Murray, Joe N. Nunnery, James M. Fisher Oct 1998

Frequently Asked Questions Concerning The Aisi Base Test And The Use Of The Aisi Anchorage Equations, Roger A. Laboube, Thomas M. Murray, Joe N. Nunnery, James M. Fisher

CCFSS Proceedings of International Specialty Conference on Cold-Formed Steel Structures (1971 - 2018)

The AISI Base Test Method was first introduced into the 1996 AISI Specification. Section C3.1.4 of the Specification provides a method for determining the nominal moment strength of a C- or Z- section under gravity load in the plane parallel to the web with the top flange supporting a standing seam roof system. A standing seam roof system is defined as a roof system in which the side laps between the roof panels or deck are arranged in a vertical position above the roof line, and the roof panel system is secured to the purlins by means of concealed hold …


Web Crippling Of Single Web Cold Formed Steel Members Subjected To End One-Flange Loading, R. R. Gerges, R. M. Schuster Oct 1998

Web Crippling Of Single Web Cold Formed Steel Members Subjected To End One-Flange Loading, R. R. Gerges, R. M. Schuster

CCFSS Proceedings of International Specialty Conference on Cold-Formed Steel Structures (1971 - 2018)

Results of an extensive experimental investigation of the web crippling behavior of cold formed steel C-sections are presented. This study was devoted to the End One Flange, EOF, loading case, with particular emphasis on large inside bend radius to thickness ratios, (R = ri/t). Seventy-two C-sections with R values ranging between five and 10 were tested at the University of Waterloo. Comparing the experimental results with predictions using the current North American Cold Formed Steel Design Standards, considerable underestimation was observed. Using the same model of the design expression currently used in the Canadian Standard (S136-94), and including 164 test …


A Simplified Model For Distortional Buckling Of Channels And Zees In Flexure, Duane S. Ellifritt, Robert L. Glover, Jonathan D. Hren Oct 1998

A Simplified Model For Distortional Buckling Of Channels And Zees In Flexure, Duane S. Ellifritt, Robert L. Glover, Jonathan D. Hren

CCFSS Proceedings of International Specialty Conference on Cold-Formed Steel Structures (1971 - 2018)

Certain cold-formed sections like channels and zees, when subjected to bending in the plane of the web, often fail in laboratory tests at a load less than that predicted by standard specification equations. The mode of failure is an upward movement of the compression flange and lip relative to the web, which may remain fairly plane. When bends which were right angles change dramatically under load, the section changes shape, or distorts, resulting in a reduction of the section stiffness followed by buckling of the flange. Such a failure is referred to as "distortional buckling". An analytical solution to the …


Buckling Mode Interaction In Cold-Formed Steel Columns And Beams, C. Jiang, Viorel Ungureanu, J. Michael Davies Oct 1998

Buckling Mode Interaction In Cold-Formed Steel Columns And Beams, C. Jiang, Viorel Ungureanu, J. Michael Davies

CCFSS Proceedings of International Specialty Conference on Cold-Formed Steel Structures (1971 - 2018)

The buckling behaviour of cold-formed steel columns and beams is far from simple. The three generic forms of buckling, namely local buckling, distortional buckling and overall buckling, generally have different wavelengths and are usually restricted to different span ranges. However, there is also the possibility of interaction among these buckling modes at a certain span length. Thus, local plate buckling and distortional buckling may occur together with lateral-torsional buckling in such a way that they all have an influence on the ultimate load carrying capacity of a member. The influence of local buckling is taken into consideration in design codes …


Distortional Buckling Formulae For Thin Walled Channel And Z-Sections With Return Lips, John T. Merrick, Gregory J. Hancock, M. R. Bamach Oct 1998

Distortional Buckling Formulae For Thin Walled Channel And Z-Sections With Return Lips, John T. Merrick, Gregory J. Hancock, M. R. Bamach

CCFSS Proceedings of International Specialty Conference on Cold-Formed Steel Structures (1971 - 2018)

Cold-formed Channel- and Z-sections subject to both flexure and torsion may undergo distortional buckling where the flange and lip rotate about the flange/web junction. This mode of failure is prevalent in purlin sections when lateral deformation of the section is prevented and when the sections are manufactured from high strength steel. In an attempt to prevent distortional buckling, some manufacturers have added additional return lips to the flange lips to produce complex edge stiffeners. The Australian/New Zealand Standard for Cold-Formed Steel Structures includes design rules for determining the distortional buckling strength of cold-formed beam and column sections. These design rules …


Laterally Braced Cold-Formed Steel Flexural Members With Edge Stiffened Flanges, Benjamin W. Schafer, Teoman Pekoz Oct 1998

Laterally Braced Cold-Formed Steel Flexural Members With Edge Stiffened Flanges, Benjamin W. Schafer, Teoman Pekoz

CCFSS Proceedings of International Specialty Conference on Cold-Formed Steel Structures (1971 - 2018)

The moment capacity of a laterally braced cold-formed steel flexural member with edge stiffened flanges (e.g., a channel or zee section) may be adversely affected by local or distortional buckling. Traditional design methods recognize the need to explicitly account for local buckling, but not distortional buckling. Experimental data and numerical analyses suggest that proper strength prediction of laterally braced cold-formed steel flexural members requires explicit treatment of distortional buckling. New procedures for hand prediction of the buckling stress in the local and distortional mode are presented. Numerical investigations are employed to highlight post-buckling behavior unique to the distortional mode. A …


Behaviour Of Thin G550 Sheet Steel Bolted Connections, Colin A. Rogers, Gregory J. Hancock Oct 1998

Behaviour Of Thin G550 Sheet Steel Bolted Connections, Colin A. Rogers, Gregory J. Hancock

CCFSS Proceedings of International Specialty Conference on Cold-Formed Steel Structures (1971 - 2018)

This paper provides a summary of results detailing the behaviour of bolted connections tested in shear, which were composed of 0.42 mm G550, 0.60 mm G550 and 0.60 mm G300 sheet steels (to the 1993 Australian Standard AS 1397). Recommendations concerning the adequacy of current design standards with respect to the design of thin sheet steel bolted connections are made, along with the calibration of applicable limit states resistance equations for the three observed modes of failure; end pull-out, bearing, and net section fracture.


Factors Influencing The Strength Of Mechanical Clinching, Remo Pedreschi, Braj Sinha, Russell Davies, Rory Lennon Oct 1998

Factors Influencing The Strength Of Mechanical Clinching, Remo Pedreschi, Braj Sinha, Russell Davies, Rory Lennon

CCFSS Proceedings of International Specialty Conference on Cold-Formed Steel Structures (1971 - 2018)

The influence of material strength and thickness, direction of load, multi-layer connections and dis-similar thicknesses of steel on the strength of mechanical clinching is considered.. Expressions to predict the strength of mechanical clinching are presented.


Lateral Load Strength Of Screw Connections In 29ga Metal, G. A. Anderson, V. C. Kelley Oct 1998

Lateral Load Strength Of Screw Connections In 29ga Metal, G. A. Anderson, V. C. Kelley

CCFSS Proceedings of International Specialty Conference on Cold-Formed Steel Structures (1971 - 2018)

The results of 300 tests on screwed connections in shear are presented. The load capacity of screws in a row is shown to be additive and screws placed in narrow ribs of 29ga steel have the same strength as screws placed in flat sheets. The AISI equation for tilting strength of screw connections under predicts the strength of the screw connections tested. A regression equation is developed for tilting and compared to the AISI tilting equation and a third party test data. The regression equation is more accurate but less precise than the AISI equation.


A Cost Based Approach To Design Of Residential Steel Roof Systems, B. Mobasher, S-Y Chen, C. Young, S. D. Rajan Oct 1998

A Cost Based Approach To Design Of Residential Steel Roof Systems, B. Mobasher, S-Y Chen, C. Young, S. D. Rajan

CCFSS Proceedings of International Specialty Conference on Cold-Formed Steel Structures (1971 - 2018)

A comprehensive system for the design of residential steel roof truss systems is presented. The research involved three distinct stages. In the first stage, components of the truss systems were tested in order to determine their member properties subjected to axial force and bending moments. Finite element simulations of these tests were carried out to further verify the, calculations obtained using the AISI-LRFD code guidelines. The AlSI-LRFD code based design curves were used for the actual design, while the laboratory experiments and the finite element results provided additional checks and verification of the AlSI values. The second stage of the …


Compressional Behaviour Of Stainless Steel Short Struts, M. Macdonald, J. Rhodes, G. T. Taylor Oct 1998

Compressional Behaviour Of Stainless Steel Short Struts, M. Macdonald, J. Rhodes, G. T. Taylor

CCFSS Proceedings of International Specialty Conference on Cold-Formed Steel Structures (1971 - 2018)

The effects of cold forming on both carbon steel and stainless steel structural members has been the subject of extensive research since the early 1940's. Design code specifications for carbon steel members have been published in many countries around the world, including BS 5950, Part 5 in the UK (1) the AlSI Specification in the USA (2), and the new Eurocode 3, Part 1.3 (3). For stainless steel members there are fewer design code specifications available, and those that are available, which include the ANSI/ASCE in the USA (4) and the new Eurocode 3, Part 1.4 (5), do not give …


The Effect Of Cold Forming On Type 3cr12 Square Tubes, Rudolph Laubscher Oct 1998

The Effect Of Cold Forming On Type 3cr12 Square Tubes, Rudolph Laubscher

CCFSS Proceedings of International Specialty Conference on Cold-Formed Steel Structures (1971 - 2018)

A non linear finite element simulation is conducted which completely simulates the forming of the tube from flat virgin plate to its final shape. The predicted residual stresses and amount of cold forming in the tube sides and comers are then compared to actual experimental data from cold formed tubes where the initial material properties and the material properties after the cold forming process are known. This illustrates the usefulness of the non linear finite element method in predicting how the material properties change during cold forming and gives a useful insight in what the actual condition of the material …


A Non Linear Design Model For Continuous Multi-Span Light Gauge Sheeting And Members, Leopold K. Sokol Oct 1998

A Non Linear Design Model For Continuous Multi-Span Light Gauge Sheeting And Members, Leopold K. Sokol

CCFSS Proceedings of International Specialty Conference on Cold-Formed Steel Structures (1971 - 2018)

The calculation of profiled sheeting and members by using the post-critical stage in which a plastic hinge is originated at the internal support is possible provided that the relationships between the support moment, reaction and hinge rotation are known. There are two alternative procedures of testing for obtaining these data: double-span test or internal support test. In the second one, instead of a global behaviour, only the local relationships between the three above characteristics are determined. When calculating with the model proposed in Eurocode 3, Part 1.3, the above two different test procedures do not lead to close enough results. …


Analysis Of Hat Sections With Multiple Intermediate Longitudinal Stiffeners, V. V. Acharya, R. M. Schuster Oct 1998

Analysis Of Hat Sections With Multiple Intermediate Longitudinal Stiffeners, V. V. Acharya, R. M. Schuster

CCFSS Proceedings of International Specialty Conference on Cold-Formed Steel Structures (1971 - 2018)

This paper is the second paper by the authors on the subject of the behavior of cold formed steel hat sections in bending with multiple intermediate longitudinal stiffeners. The first paper, also contained in these Proceedings, deals with the test results only (Acharya and Schuster, 1998). Presented in this paper is the analysis associated with the test program that was conducted at the University of Waterloo. The main objective was to develop a consistently accurate and practical method of predicting the ultimate bending strength of sections that fail in overall plate buckling. Recent testing carried out by previous researchers indicates …


Bending Tests Of Hat Sections With Multiple Longitudinal Stiffeners, V. V. Acharya, R. M. Schuster Oct 1998

Bending Tests Of Hat Sections With Multiple Longitudinal Stiffeners, V. V. Acharya, R. M. Schuster

CCFSS Proceedings of International Specialty Conference on Cold-Formed Steel Structures (1971 - 2018)

This paper is the first in a series of articles that report findings of the authors investigation into the behavior of cold formed steel hat sections in bending with multiple intermediate longitudinal stiffeners. Presented in this paper is the test program that was carried out at the University of Waterloo as part of a two year research program. It is known that sections with multiple intermediate stiffeners can fail either in a local sub-element buckling mode, or alternatively, can experience an overall plate buckling mode of failure. Although both failure modes were examined, the main objective was to develop a …


Shear Plus Bending In Lapped Z-Purlins, Keith Almoney, Thomas M. Murray Oct 1998

Shear Plus Bending In Lapped Z-Purlins, Keith Almoney, Thomas M. Murray

CCFSS Proceedings of International Specialty Conference on Cold-Formed Steel Structures (1971 - 2018)

Six two purlin line, three span continuous Z-purlin tests were conducted to show that combined shear plus bending is a possible failure mode immediately outside the lapped portion of the purlin lines. AISI Specification provisions predicted that combined shear plus bending was the controlling limit state. Strain gage data showed that local buckling occurred immediately outside of the lapped portion of the purlins lines prior to failure which caused moment to redistribute to the positive moment region. It is concluded that shear plus bending is a possible controlling limit state for continuous lapped purlins.


Web Crippling Behaviour Of Cold-Formed Unlipped Channels, Ben Young, Gregory J. Hancock Oct 1998

Web Crippling Behaviour Of Cold-Formed Unlipped Channels, Ben Young, Gregory J. Hancock

CCFSS Proceedings of International Specialty Conference on Cold-Formed Steel Structures (1971 - 2018)

An experimental investigation of cold-formed unlipped channels subject to web crippling is described. The tests were carried out under four loading conditions according to the AISI Specification, namely End-One-Flange (EOF), Interior-One-Flange (IOF), End-Two-Flange (ETF), and Interior-Two-Flange (ITF) loading. The concentrated load or reaction forces were applied by means of bearing plates which acted across the full flange widths of the channels. The web crippling test results are compared with the American Iron and Steel Institute (AISI 1996) Specification and the Australian/New Zealand Standard (AS/NZS 4600-1996) for cold-formed steel structures. The design web crippling strength predictions given by the specifications have …


Web Crippling Of Cold Formed Steel Members, K. Prabakaran, R. M. Schuster Oct 1998

Web Crippling Of Cold Formed Steel Members, K. Prabakaran, R. M. Schuster

CCFSS Proceedings of International Specialty Conference on Cold-Formed Steel Structures (1971 - 2018)

A new design expression for web crippling of cold formed steel members has been developed. An extensive statistical analysis was performed using published test data from Canada, the United States, Sweden and France to develop new expressions for the web crippling strength of cold formed steel members under four different loading cases, i.e. (1) end one-flange loading (EOF), (2) interior one-flange loading (lOF), (3) end two-flange loading (ETF) and (4) interior two-flange loading (lTF). I-sections made of two channels connected back-to-back, Z-sections, channels and multiple web sections (decks) were considered. Comparisons were made with the web crippling expressions presented in …


Web Crippling Strength Of Members Using High-Strength Steels, Shaojie Wu, Wei-Wen Yu, Roger A. Laboube Oct 1998

Web Crippling Strength Of Members Using High-Strength Steels, Shaojie Wu, Wei-Wen Yu, Roger A. Laboube

CCFSS Proceedings of International Specialty Conference on Cold-Formed Steel Structures (1971 - 2018)

A total of 148 web crippling tests were conducted using high-strength, low-ductility Structural Grade 80 of ASTM A653 steel (former ASTM A446 Grade E steel) and tests results were evaluated along with additional 114 web crippling tests which were reported in 1986 as part of a project on Design of Automotive Structural Components Using High-Strength Sheet Steels. Four loading conditions, namely End-One-Flange (EOF),lnterior-One-Flange (IOF), End-Two-Flange (ETF), and Interior-Two-Flange (ITF) conditions, were considered in the web crippling tests. Test results indicate that the tested ultimate loads for the four loading conditions were higher than the predicted loads using the AISI Specifications …


Behaviour Of Locally Buckled Singly Symmetric Columns, Ben Young, Kim J. R. Rasmussen Oct 1998

Behaviour Of Locally Buckled Singly Symmetric Columns, Ben Young, Kim J. R. Rasmussen

CCFSS Proceedings of International Specialty Conference on Cold-Formed Steel Structures (1971 - 2018)

An experimental investigation into the behaviour of locally buckled cold-formed plain and lipped channel columns compressed between fixed and pinned ends is described in this paper. It is shown experimentally that local buckling does not induce overall bending of fixed-ended singly symmetric columns, as it does of pin-ended singly symmetric columns. Consequently, local buckling has fundamentally different effects on the behaviour of fixed-ended and pin-ended singly symmetric columns. In order to demonstrate this result experimentally, a series of tests was performed on plain and lipped channels brake-pressed from high strength structural steel sheets. The different effects of local buckling on …


Columns Under Loads Of Varying Eccentricity, J. Rhodes Oct 1998

Columns Under Loads Of Varying Eccentricity, J. Rhodes

CCFSS Proceedings of International Specialty Conference on Cold-Formed Steel Structures (1971 - 2018)

A series of tests on small lipped channel section columns is reported in this paper. The columns were loaded with varying degrees of eccentricity. The eccentricity of loading was produced by offsetting the loading line from the neutral axis of the section, and the offset could be set to a different degree at each end of the column. By this means the effect of moment variation along the column could be examined experimentally and the results compared with the predictions of different design codes for this type of loading. The predictions of the 1986 AISI Specification, the British Standard and …


Tests Of Cold-Formed Channel Columns, Ben Young, Kim J. R. Rasmussen Oct 1998

Tests Of Cold-Formed Channel Columns, Ben Young, Kim J. R. Rasmussen

CCFSS Proceedings of International Specialty Conference on Cold-Formed Steel Structures (1971 - 2018)

The paper presents a series of tests on cold-formed plain and lipped channel columns, compressed between fixed and pinned ends. While it is well-known that local buckling of pin-ended channel columns induces overall bending, this phenomenon does not occur in fixed-ended channel columns which remain straight after local buckling and only bend when overall buckling occurs. These fundamentally different effects of local buckling on the behaviour of pin-ended and fixed-ended channel sections lead to inconsistencies in traditional design approaches, which account for full or partial rotational end restraint solely by using effective lengths. A series of tests was performed on …


A European Design Code For Pallet Racking, M. H. R. Godley, J. Michael Davies Oct 1998

A European Design Code For Pallet Racking, M. H. R. Godley, J. Michael Davies

CCFSS Proceedings of International Specialty Conference on Cold-Formed Steel Structures (1971 - 2018)

The work leading to a European design code for pallet racking started almost 25 years ago. Many difficulties were encountered in the early days of this work. Notable were the absence of a consistent safety philosophy between the various countries of Europe and the existence of procedures with which the manufacturers were comfortable but which were potentially unsafe. There were also difficulties in defining acceptable standard. test procedures. The emergence of Eurocode 3, especially Part 1.3 dealing with cold formed sections, provided a new impetus to the work because here was a European code which provided the required basis for …


Experimental Procedures For Stub Column Tests, Y. Pu, M. H. R. Godley, R. G. Beale Oct 1998

Experimental Procedures For Stub Column Tests, Y. Pu, M. H. R. Godley, R. G. Beale

CCFSS Proceedings of International Specialty Conference on Cold-Formed Steel Structures (1971 - 2018)

In this paper a total of 36 stub columns was tested by two different experimental procedures, namely the FEM and AISI procedures, to investigate the difference in the ultimate load between these procedures. Of these 26 were carried out in the pin-ended condition according to FEM, the rest were in the fixed-end condition according to AlSI specification. It is shown that the failure loads obtained by the two experimental procedures were very close to each other. Both procedures worked well. The AISI procedure is recommended as the standard procedure.


Rotational Stiffnesses Of Semi-Rigid Baseplates, X. Feng, M. H. R. Godley, R. G. Beale Oct 1998

Rotational Stiffnesses Of Semi-Rigid Baseplates, X. Feng, M. H. R. Godley, R. G. Beale

CCFSS Proceedings of International Specialty Conference on Cold-Formed Steel Structures (1971 - 2018)

The paper describes a test procedure to determine the rotational stiffnesses and moment-curvature relationships of semi-rigid baseplates of cold-formed structures. The influence of the modulus of the foundation subgrade on baseplate performance is determined. Increasing the axial load applied to a baseplate is shown to increase the ultimate moment-rotation capacity of a baseplate.


Fire Resistance On Bearing Wall Using Steel & Gypsum, In-Kyu Kwon, Kwang Choi, Jee Nam-Yong Oct 1998

Fire Resistance On Bearing Wall Using Steel & Gypsum, In-Kyu Kwon, Kwang Choi, Jee Nam-Yong

CCFSS Proceedings of International Specialty Conference on Cold-Formed Steel Structures (1971 - 2018)

The conventional loadbearing wall systems generally used in Korea are composed of concrete and brick. Which materials have many defaults like long-term construction period and cost increase. Recently in us, a rapid increase in the usage of cold-formed steel section in housing and commercial building construction can widely be seen. The loadbearing wall assembly composed of light gauge-steel and gypsum board can preferably be applied to residential and commercial building of 5 stories or below. In order that light-gauge steel framing can be prevalently introduced in our domestic housing market, the wall assembly must have sufficient fire-resistant performance. Fire-resistant tests …


Seismic Design Of Light Gauge Steel Structures: A Discussion, Reynaud Serrette Oct 1998

Seismic Design Of Light Gauge Steel Structures: A Discussion, Reynaud Serrette

CCFSS Proceedings of International Specialty Conference on Cold-Formed Steel Structures (1971 - 2018)

In a highly competitive and aggressive construction market, designers are always looking for new, proven ways to design safe, economical building structures. This is even more relevant in tract residential construction where a few dollars saved on one detail can affect who is awarded a project. In residential construction, a complete load bearing light gauge steel (LGS) system is now somewhat commonplace in the United States. Architects and engineers who once designed almost exclusively with other conventional materials are now consider LGS as an alternative. Although, it is feasible to make a direct substitution of LGS for conventional wood framing, …