Open Access. Powered by Scholars. Published by Universities.®
- Keyword
-
- Beams (2)
- Analytical modeling (1)
- Columns (1)
- Concrete (1)
- Concrete topping (1)
-
- Construction materials; fire-resistance testing; fire standards; full-scale testing (1)
- Elevated temperatures (1)
- Fire resistance (1)
- Frames (1)
- GFRP (1)
- Heat transfer (1)
- Hollowcore slabs (1)
- Incremental dynamic analysis (1)
- Inter-storey drift (1)
- Modular steel building (1)
- Moment frame (1)
- Peel stress (1)
- Push-off tests (1)
- Pushover (1)
- Reinforced concrete (1)
- Reinforced concrete (RC) (1)
- Residual drift (1)
- Retrofitting (1)
- SS (1)
- Seismic damage (1)
- Seismic damage; seismic residual deformations; shape memory alloy; superelasticity; moment frame; reinforced concrete (1)
- Seismic performance (1)
- Seismic residual deformations (1)
- Shape memory alloy (1)
- Shape memory alloys (SMAs) (1)
- Publication
- Publication Type
Articles 1 - 30 of 149
Full-Text Articles in Structural Engineering
Fire-Resistance Testing Procedures For Construction Elements—A Review, Shashikant Chaturvedi, Ajitanshu Vedrtnam, Maged A. Youssef, Martin T. Palou, Gonzalo Barluenga, Kishor Kalauni
Fire-Resistance Testing Procedures For Construction Elements—A Review, Shashikant Chaturvedi, Ajitanshu Vedrtnam, Maged A. Youssef, Martin T. Palou, Gonzalo Barluenga, Kishor Kalauni
Civil and Environmental Engineering Publications
Fire accidents are a significant risk to human life and civil infrastructure. As a countermeasure, the regulatory bodies of different countries have established standards for evaluating the performance of construction elements during fire exposure. ISO 834 is the globally accepted fire-resistance testing standard. Other standards include ASTM E119, BS 476, IS 3809, JIS A 1304, AS 1503, EN 1363, and GB/T 9978, which are utilized by the US, Britain, India, Japan, Australia, Europe, and China, respectively. This article presents a summary and comparison of the fire-resistance testing standards. In reality, standard tests for isolated structural members may not efficiently portray …
Experimental And Numerical Structural Assessment Of Transparent And Tinted Glass During Fire Exposure, A Vedrtnam, C Bedon, Maged A. Youssef, M Wamiq, Amer Sabsabi, S Chaturvedi
Experimental And Numerical Structural Assessment Of Transparent And Tinted Glass During Fire Exposure, A Vedrtnam, C Bedon, Maged A. Youssef, M Wamiq, Amer Sabsabi, S Chaturvedi
Civil and Environmental Engineering Publications
Transparency, illumination, aesthetic and energy requirements have considerably increased the use of glass in modern high-rise buildings. During fire exposure, fracture and shattering of windows and facades accelerate the spread and severity of fire, which increases the risk for the occupants and the amount of structural damage. This paper aims at analyzing the effect of non-uniform thermal gradients on the flexural capacity of ordinary glass panels. Both transparent and tinted glass panels are considered to account for widely-used glass compositions. The bending response of fire-damaged glass panels is experimentally explored considering different durations of thermal exposure. The thermal breakage due …
Seismic Performance Of Reinforced Concrete Frames Retrofitted Using External Superelastic Shape Memory Alloy Bars, Yamen Ibrahim Elbahy, Maged A. Youssef, Mohamed E. Meshaly
Seismic Performance Of Reinforced Concrete Frames Retrofitted Using External Superelastic Shape Memory Alloy Bars, Yamen Ibrahim Elbahy, Maged A. Youssef, Mohamed E. Meshaly
Civil and Environmental Engineering Publications
Pre-1970s designed and built reinforced concrete frame structures are considered unsafe when subjected to seismic loads. Insufficient anchorage of the beam reinforcement in the beam-column joints of these structures is considered a main deficiency. Newly built frame structures are seismically designed for safety, where high inelastic deformations can occur under moderate to strong earthquakes. Minimizing these inelastic deformations makes the structure repairable. One way to minimize these residual deformations is by using smart materials such as superelastic shape memory alloys (SMAs). In this paper, the seismic performance of RC frames retrofitted using external superelastic SMA bars is investigated and compared …
Seismic Fragility Assessment Of Superelastic Shape Memory Alloy Reinforced Concrete Shear Walls, Emad A. Abraik, Maged A. Youssef
Seismic Fragility Assessment Of Superelastic Shape Memory Alloy Reinforced Concrete Shear Walls, Emad A. Abraik, Maged A. Youssef
Civil and Environmental Engineering Publications
Mitigation of seismic damage can be achieved through self-centering techniques. One of the potential techniques involves the use of Superelastic Shape Memory Alloy (SE-SMA) bars in Reinforced Concrete (RC) structures. This study explores the use of such bars in the plastic-hinge regions of RC walls. The seismic performance and vulnerability of SE‑SMA RC walls of ten- and twenty-story buildings are analytically assessed using fragility curves. The maximum inter-story drift, residual drift, and fragility are evaluated using multi strip analysis. The results clearly demonstrate the superior seismic performance of SE-SMA RC walls as compared to steel RC walls.
Seismic Performance Of Modular Steel Frames Equipped With Shape Memory Alloy Braces, Papia Sultana, Maged A. Youssef
Seismic Performance Of Modular Steel Frames Equipped With Shape Memory Alloy Braces, Papia Sultana, Maged A. Youssef
Civil and Environmental Engineering Publications
The demand for modular steel buildings (MSBs) has increased because of the improved quality, fast on-site installation, and lower cost of construction. Steel braced frames are usually utilized to form the lateral load resisting system of MSBs. During earthquakes, the seismic energy is dissipated through yielding of the components of the braced frames, which results in residual drifts. Excessive residual drifts complicate the repair of damaged structures or render them irreparable. Researchers have investigated the use of superelastic shape memory alloys (SMAs) in steel structures to reduce the seismic residual deformations. This study explores the potential of using SMA braces …
Shape Memory Alloy Reinforced Concrete Frames Vulnerable To Strong Vertical Excitations, M A. Elfeki, Maged A. Youssef
Shape Memory Alloy Reinforced Concrete Frames Vulnerable To Strong Vertical Excitations, M A. Elfeki, Maged A. Youssef
Civil and Environmental Engineering Publications
Reinforced concrete (RC) framed buildings dissipate the seismic energy through yielding of the reinforcing bars. This yielding jeopardizes the serviceability of these buildings as it results in residual lateral deformations. Superelastic shape memory alloys (SMAs) can recover inelastic strains by stress removal. This paper extends previous research by the authors that optimized the use of SMA bars in RC frames considering the horizontal seismic excitation by addressing the effect of the vertical seismic excitation. A steel RC six-storey building designed according to current seismic standards is considered as case study. Five different earthquake records with strong vertical components are …
Ductile Corrosion-Free Gfrp-Stainless Steel Reinforced Concrete Elements, Maged A. Youssef, Mohamed E. Meshaly, Ahmed Elansary
Ductile Corrosion-Free Gfrp-Stainless Steel Reinforced Concrete Elements, Maged A. Youssef, Mohamed E. Meshaly, Ahmed Elansary
Civil and Environmental Engineering Publications
Corrosion of steel rebars is known to cause deterioration of concrete structures that can lead to catastrophic failures. To mitigate this problem, steel rebars can be replaced with Glass Fiber-Reinforced Polymer (GFRP) rebars. However, the lack of ductility of GFRP-reinforced elements has prevented their use in many structural applications, especially in seismic areas. Stainless Steel (SS) rebars are corrosion resistant and have adequate energy absorption and ductility. However, they are much more expensive than steel rebars. This paper proposes the combined use of SS and GFRP rebars to achieve ductile and corrosion-free elements. The first challenge for such a proposal …
Mat-701: Predicting The Compressive Strength Of Ultra-Lightweight Concrete By An Artificial Neural Network, Jordan Ouellet, Jean-Luc Martel, Claudiane Ouellet-Plamondon, Alan Carter
Mat-701: Predicting The Compressive Strength Of Ultra-Lightweight Concrete By An Artificial Neural Network, Jordan Ouellet, Jean-Luc Martel, Claudiane Ouellet-Plamondon, Alan Carter
Canadian Society for Civil Engineering
Ultra-lightweight concrete (ULWC) has potential applications for floating structures and architectural elements because of its dry density coming in at under 1000 kg/m3. The objective was to develop an artificial neural network (ANN) to aid the ULWC designer according to his needs. Boundary conditions were set for each material and 13 constraints based on the water binder ratio, density, air content, binder and aggregate content. The ANN predicted the compressive strength with a comfortable margin of error, with the gap encountered being attributed to variability in workability. Precise constraints and boundary conditions are needed to ensure a lower variability in …
Mat-702: Mechanical Behaviour Of Ultra-High Performance Concrete Obtained With Different Concrete Constituents And Mix Designs, Mahmoud Sayed-Ahmed, Khaled Sennah, Moulay Youssef Monsif
Mat-702: Mechanical Behaviour Of Ultra-High Performance Concrete Obtained With Different Concrete Constituents And Mix Designs, Mahmoud Sayed-Ahmed, Khaled Sennah, Moulay Youssef Monsif
Canadian Society for Civil Engineering
This research investigates the mechanical behaviour for the Ultra-High Performance Concrete (UHPC) and UltraHigh Performance Fiber Reinforced Concrete (UHPFRC). UHPC and UHPFRC are designed to be self-consolidated concrete that level itself without mechanical vibration due to its highly flowability and moderate viscosity. UHPFRC is used as joint-fill cementitious materials for the connections of prefabricated bride elements and systems used for the Accelerated Bridge Construction and rapid bridge replacement. The main concrete constituents of such materials consist from: binders (cement), powders (fillers), liquids (additives), water, and fibers. Hence, the mixture proportion design should follow a densified mixture design algorithm to densify …
Mat-704: Resistance Of Concrete Incorporating Portland Limestone Cement To Sulfuric Acid, Mahmud Amin, Mohamed T. Bassuoni
Mat-704: Resistance Of Concrete Incorporating Portland Limestone Cement To Sulfuric Acid, Mahmud Amin, Mohamed T. Bassuoni
Canadian Society for Civil Engineering
Concrete has long been the most popular choice for constructing key infrastructural elements such as sewer pipes, water treatment facilities, industrial floors and foundations. However, many field cases from all around the world have shown that concrete elements in these environments are severely damaged due to biogenic and/or chemical sulfuric acid attack. Since high alkalinity is required for the stability of the cementitious matrix, concrete is highly prone to acid attacks, which decalcify and disintegrate the hydrated cement paste to various levels based on exposure conditions and type of concrete. Numerous studies have been conducted to enhance the durability of …
Mat-705: Improving The Efficiency Of Zinc Sacrificial Anodes In Repaired Concrete, Ahmed G. Bediwy, Mohamed T. Bassuoni, Martin Beaudette
Mat-705: Improving The Efficiency Of Zinc Sacrificial Anodes In Repaired Concrete, Ahmed G. Bediwy, Mohamed T. Bassuoni, Martin Beaudette
Canadian Society for Civil Engineering
Zinc sacrificial anodes are considered an effective and economical method to prevent the electrochemical corrosion of steel bars by providing cathodic current to bars, which can provide corrosion protection at low galvanic current densities in the range of 0.2 to 2 mA/m2. Sacrificial anodes are commonly used in RC structures particularly in bridge decks to mitigate a critical phenomenon that occurs in the original concrete beside the repaired patches, which is known as the ‘halo effect’. One of the key factors affecting the efficacy of zinc anodes is the resistivity of concrete or cementitious repair material in which these anodes …
Mat-707: Development Of Enhanced Test Methods To Evaluate Alkali-Silica Reaction In Concrete, Noura Sinno, Medhat Shehata
Mat-707: Development Of Enhanced Test Methods To Evaluate Alkali-Silica Reaction In Concrete, Noura Sinno, Medhat Shehata
Canadian Society for Civil Engineering
The research presented in this paper studies the effect of sample geometry and temperature on expansion due to alkali-silica reaction (ASR) in concrete. Expansions of cubes and cylinders are compared to those of the standard prisms. Control samples, samples with fly ash (FA) and others with slag are investigated at two temperatures, 38°C and 60°C. At 38°C, results showed that smaller samples have higher expansion at early ages. However, larger samples such as cubes and cylinders seem to reach higher expansion compared to prisms after 32 weeks for both control and samples with fly ash. In addition, the results showed …
Mat-708: Monitoring The Corrosion Process Of Reinforced Concrete Flat Slab-Column Connection, Mahmoud E. Said, Amgad Hussein, Assem A. A. Hassan
Mat-708: Monitoring The Corrosion Process Of Reinforced Concrete Flat Slab-Column Connection, Mahmoud E. Said, Amgad Hussein, Assem A. A. Hassan
Canadian Society for Civil Engineering
The corrosion of the steel reinforcement embedded in a two-way reinforced concrete flat slab around the column stub area was investigated in this study, which aimed to studying the effect of corrosion on the shear punching behavior. Two square flat slab-column connections were cast, the flat slab dimension was 1900 mm × 1900 mm × 150 mm, and the column dimensions was 250 mm × 250 mm. A specific delaminated area was corroded around the column stub to emphasize the effect of corrosion around punching area. The corrosion reached two levels of mass loss uniformly over that specified area: 0% …
Mat-711: Utilization Of Recycled Crumb Rubber In Structural Self-Consolidating Concrete, Mohamed K. Ismail, Assem A. A. Hassan, Madolyn A. Lundrigan
Mat-711: Utilization Of Recycled Crumb Rubber In Structural Self-Consolidating Concrete, Mohamed K. Ismail, Assem A. A. Hassan, Madolyn A. Lundrigan
Canadian Society for Civil Engineering
The present work evaluates the impact of using recycled crumb rubber (CR) as a partial replacement of fine aggregate on the fresh and mechanical properties of concrete composite, especially when self-consolidating concrete is used. In this study, seven mixtures containing various amounts of fine CR (0-30% by volume of sand) were tested. The fresh properties tests included flowability, passing ability, and segregation resistance. On the other hand, the mechanical properties tests included compressive strength, modulus of elasticity, splitting tensile strength, and flexural strength. The results indicated that although increasing the CR replacement decreased the fresh and mechanical properties of concrete, …
Mat-712: Microstructural Investigations On The Self-Healing Ability Of Engineered Cementitious Composites Incorporating Different Mineral Admixtures, Ahmed Alyousif, Khandaker M. Anwar Hossain, Mohamed Lachemi, Mustafa Sahmaran
Mat-712: Microstructural Investigations On The Self-Healing Ability Of Engineered Cementitious Composites Incorporating Different Mineral Admixtures, Ahmed Alyousif, Khandaker M. Anwar Hossain, Mohamed Lachemi, Mustafa Sahmaran
Canadian Society for Civil Engineering
The present study investigates the impacts that self-healing has on the microstructure characteristics of microcracked Engineered Cementitious Composites (ECC). These have two contrasting maturity levels and, furthermore, they involve three varying mineral admixtures that have very different chemical constituents. The impact of self-healing on the transport characteristics was examined by employing rapid chloride permeability tests (RCPT). The findings indicated that, if the appropriate mineral admixture type and conditioning were chosen, it would be possible to enhance the majority of the chloride ion penetrability levels following a 30-day period of water curing. As a result, the majority of the findings were …
Mat-713: Evaluation Of Ndt Techniques For Concrete Bridge Decks Using Fuzzy Analytical Hierarchy Process, Tarek Omar, Moncef L. Nehdi
Mat-713: Evaluation Of Ndt Techniques For Concrete Bridge Decks Using Fuzzy Analytical Hierarchy Process, Tarek Omar, Moncef L. Nehdi
Canadian Society for Civil Engineering
Considering the colossal backlog of deteriorating bridges, transportation agencies need to systematically evaluate bridge deck conditions in order to optimize the timing, scope, and approach of preventive maintenance, repair, and replacement. Over the last few years, there have been growing interest among bridge infrastructure stakeholders in using non-destructive methodologies for bridge inspection, evaluation, and maintenance. Nondestructive testing (NDT) techniques can provide needed information about the “under-the-surface” deteriorated condition of bridge decks. This paper examines the most common NDT technologies for assessing bridge decks. Each technology was rated based on five performance measures: capability to detect subsurface defects, speed of data …
Mat-714: Condition Assessment And Deterioration Prediction Tools For Concrete Bridges: A New Look, Tarek Omar, Moncef L. Nehdi
Mat-714: Condition Assessment And Deterioration Prediction Tools For Concrete Bridges: A New Look, Tarek Omar, Moncef L. Nehdi
Canadian Society for Civil Engineering
Structural problems created by corrosion, ageing, aggressive environments, material defects and unforeseen mechanical or seismic loads can compromise the serviceability and safety of bridges. The importance of an effective bridge-management system (BMS) cannot be overstated, especially in light of the recent collapse of bridges in North America and elsewhere. Several technologies are available for assessing the condition of concrete bridges and a number of deterioration models are used to predict future bridge conditions and estimate associated funding requirements. This paper critically reviews the different available condition assessment and deterioration prediction approaches for concrete bridges. The potential applications of condition assessment …
Mat-719: Investigation Of Grouted Precast Concrete Wall Connections At Subfreezing Conditions, Douglas James Provost-Smith, Mohamed Elsayed, Moncef L. Nehdi
Mat-719: Investigation Of Grouted Precast Concrete Wall Connections At Subfreezing Conditions, Douglas James Provost-Smith, Mohamed Elsayed, Moncef L. Nehdi
Canadian Society for Civil Engineering
The effect of exposing grouted precast wall connections to subfreezing curing temperatures at early-age was explored in this study. In cold weather construction, heating of the surrounding environment of grouted precast wall connections is usually conducted for short periods of time. Hence, subfreezing conditions can affect the strength of the grout and the bond strength of the connection, which can ultimately compromise the integrity of the structure. In this study, grout specimens typical of that used in precast wall construction were cured at ambient conditions for one day, and then placed in an environmental chamber at subfreezing temperatures (-10°C and …
Mat-720: Effect Of Pore Structure On Concrete Deterioration By Physical Sulphate Attack, Ahmed R. Suleiman, Moncef L. Nehdi
Mat-720: Effect Of Pore Structure On Concrete Deterioration By Physical Sulphate Attack, Ahmed R. Suleiman, Moncef L. Nehdi
Canadian Society for Civil Engineering
Repeated crystallisation of salt minerals has been considered as the driving force for surface scaling of concrete exposed to physical sulphate attack. This damage is initiated when stresses induced by the internal pressure created via repeated salt crystallisation exceed the tensile strength of the concrete. The degree of such damage will depend mainly on the structure and connectivity of pores, which control the penetration of sulphates into the concrete. Several factors affect the pore structure including the concrete constituents, mixture proportions and the curing process. Therefore, in this paper, the effect of the pore structure on concrete deterioration by physical …
Mat-722: Effect Of Fiber Orientation On The Behavior Of Cfrp Confined Concrete Cylinders, Ahmed Sulaiman, Husham Almansour, Hassan Aoude
Mat-722: Effect Of Fiber Orientation On The Behavior Of Cfrp Confined Concrete Cylinders, Ahmed Sulaiman, Husham Almansour, Hassan Aoude
Canadian Society for Civil Engineering
This paper presents the results of an ongoing experimental investigation examining the effect of fiber orientation and stacking sequence on the behavior of FRP-confined concrete. As part of the experimental study, 100 mm x 200 mm concrete cylinders were jacketed with carbon fiber reinforced polymer (CFRP) sheets and tested under pure axial compressive loading. The specimens were confined using various CFRP stacking sequences, with fibers oriented at 0⁰, 90⁰, and ±45⁰. Furthermore, within each stacking sequence, the numbers of layers was varied from 4 to 8 to examine the effect of number of plies on the behavior of the FRP-confined …
Mat-723: Bond Behaviour Of Grouted Connections Under Monotonic Tensile Loads, Mohamed Elsayed, Douglas James Provost-Smith, Moncef L. Nehdi, Osama Eissa
Mat-723: Bond Behaviour Of Grouted Connections Under Monotonic Tensile Loads, Mohamed Elsayed, Douglas James Provost-Smith, Moncef L. Nehdi, Osama Eissa
Canadian Society for Civil Engineering
Grouted bar-in-conduit connections are versatile connections widely used in the precast concrete construction. In precast load bearing wall structures, two vertical wall panels are connected by a reinforcing bar, which is projected from one panel and grouted into a sleeve placed in the other. The main function of the ties is to resist tension induced by in-plane and out-of-plane straining actions and to provide ductility to the wall assembly through the yielding of the reinforcement. Limited information is currently available on the behaviour of such connections. This paper presents the findings of an investigation conducted to investigate the behaviour of …
Mat-732: Experimental Study On The Capacity Of Barrier Deck Anchorage In Mtq Pl-3 Barrier Reinforced With Hm-Gfrp Bars With Headed Ends, Michael Rostami, Khaled Sennah, S. Milad Dehnadi
Mat-732: Experimental Study On The Capacity Of Barrier Deck Anchorage In Mtq Pl-3 Barrier Reinforced With Hm-Gfrp Bars With Headed Ends, Michael Rostami, Khaled Sennah, S. Milad Dehnadi
Canadian Society for Civil Engineering
A recent design work conducted at Ryerson University on PL-3 bridge barrier has led to an economical glass fibre reinforced polymer (GFRP) bar detailing for sustainable construction. A PL-3 barrier wall of 27.6 m length was constructed using the proposed GFRP bar configuration, incorporating the use of V-Rod headed-end bars. The proposed barrier configuration was recently crash tested to qualify its use in Canada’s highway bridges. Then, wall segments of this barrier were tested under static loading to-collapse to determine their structural behavior, crack pattern and ultimate load carrying capacity under simulated vehicle impact load. Test results led to establishing …
Mat-734: Increasing The Durability And Resilience Of Tall Buildings With Precast Concrete Enclosure Systems, Randy A. Van Straaten, John F. Straube, C. Alex Lukachko
Mat-734: Increasing The Durability And Resilience Of Tall Buildings With Precast Concrete Enclosure Systems, Randy A. Van Straaten, John F. Straube, C. Alex Lukachko
Canadian Society for Civil Engineering
In this paper precast concrete wall systems are compared to curtain wall and window wall systems in terms of durability and disaster resilience of multi-story buildings. Window wall systems are currently the enclosure system of choice for tall residential buildings in most parts of North America.
Precast concrete wall systems can be expected to last the lifetime of a building with routine seal replacement. These are highly durable systems. Windows within precast concrete wall systems will require replacement in 25-35 years but represent a limited portion of the wall area and hence are less costly and have less impact on …
Mat-735: Optimizing Performance Of Zinc Coated Reinforcing Steel In Concrete Structures, Martin Gagné, Shannon Pole, Frank Goodwin, Gary Dallin
Mat-735: Optimizing Performance Of Zinc Coated Reinforcing Steel In Concrete Structures, Martin Gagné, Shannon Pole, Frank Goodwin, Gary Dallin
Canadian Society for Civil Engineering
Corrosion of steel reinforcing bar (rebar) is the most significant cause of concrete failure, resulting in expensive repairs and premature structure replacements across the country. This paper will discuss a new, low-cost, zinc coating process for rebar. The properties of this new coated rebar and its contribution to improvement of concrete performance will be presented together with the status of related national and international standards. The Continuous Galvanized Rebar (CGR) coating process is similar to galvanizing of sheet steel. The zinc coating is durable and resistant to abrasion that is routine during transport and construction, but is also highly ductile …
Mat-744: Assessment Of Performance Of Bio Self-Healing Mortar Using Diatomaceous Earth And Silica Fume, Ahmed J. Al Bughdadi, Mohamed N. Abou-Zeid
Mat-744: Assessment Of Performance Of Bio Self-Healing Mortar Using Diatomaceous Earth And Silica Fume, Ahmed J. Al Bughdadi, Mohamed N. Abou-Zeid
Canadian Society for Civil Engineering
Cracking represents a major threat for the integrity and performance of structures. Self-healing concept was introduced to construction materials in order to enhance their performance and extend their service life with less repair. This study aims at assessing the performance of Portland cement mortar incorporating self-healing Bacillus Pseudofirmus bacteria using Diatomaceous earth (DE) to immobilize precursor and bacteria in mortar and lowering the pH level of mortar by using silica fume to provide a suitable growth environment for bacteria to generate limestone. The specimens were prepared at three different bacteria dosages and three DE dosages. Cracking of specimens was induced …
Mat-745: The Effect Of Ground Granulated Blast Furnace Slag And Silica Fume On The Durability Of High Performance Concrete In Bridge Decks, Abdulaziz Alaskar, R. Douglas Hooton
Mat-745: The Effect Of Ground Granulated Blast Furnace Slag And Silica Fume On The Durability Of High Performance Concrete In Bridge Decks, Abdulaziz Alaskar, R. Douglas Hooton
Canadian Society for Civil Engineering
High-performance concrete typically has a low water to cementing materials ratio (w/cm), high binder content and may contain high levels of supplementary cementitious materials. The effects of ground granulated blast furnace slag (GGBFS) and silica fume (SF) on the durability of HPC were investigated. In this study, HPC mixtures at 0.33 w/cm were made with two sources of blended cements containing 8% SF mixed with 25 and 50% GGBFS replacements by mass of cement. The compressive strength, drying shrinkage, thermal deformation and transport properties were tested. The preliminary test results have shown that increased fineness of the blended cement enhances …
Mat-755: Sustainable Road Construction For Heavy Traffic Using High Strength Polymeric Geocells, Sanat K. Pokharel, Meisam Norouzi, Ian Martin, Marc Breault
Mat-755: Sustainable Road Construction For Heavy Traffic Using High Strength Polymeric Geocells, Sanat K. Pokharel, Meisam Norouzi, Ian Martin, Marc Breault
Canadian Society for Civil Engineering
Construction Sustainability has been the focus of debate ever since the Brundtland commission report ‘Our Common Future’ defined Sustainable Development. Kyoto Protocol and subsequent climate change conferences leading up to the Paris submit this year has put still more emphasis on this agenda. Construction of heavy traffic unpaved access roads require huge amount of aggregate mining and long haulage in the areas of scarce virgin aggregate. Conventional practices in these road constructions seek structural adequacy but never specifically address the sustainability issue. Innovative technology that can reduce the volume of aggregate material while maintaining the structural integrity is required to …
Str-805: Experimental Evaluation Of The Robustness Of Wt Connections Under Quasi-Dynamic Load, Megan E. Hayes, Christopher H. Raebel, Christopher M. Foley
Str-805: Experimental Evaluation Of The Robustness Of Wt Connections Under Quasi-Dynamic Load, Megan E. Hayes, Christopher H. Raebel, Christopher M. Foley
Canadian Society for Civil Engineering
Flexible (simple) shear connections commonly used in steel-framed buildings are very economical and are relatively easy to fabricate. These connections are used for shear resistance, but recent studies have shown that they are capable of sustaining an interaction of rotational and axial load demand necessary for steel-framed building structures to help resist collapse in the event of unanticipated damage scenarios.
The objective of this paper is to outline and discuss an experimental effort designed to evaluate the robustness of flexible WT connections. The experimental program included twelve full-scale tests of a system consisting of two wide flange beams connected to …
Str-806: Experimental Evaluation Of The Robustness Of Single Plate Shear Connections Under Quasi-Dynamic Load, Jacklyn E. Lesser, Christopher H. Raebel, Christopher M. Foley
Str-806: Experimental Evaluation Of The Robustness Of Single Plate Shear Connections Under Quasi-Dynamic Load, Jacklyn E. Lesser, Christopher H. Raebel, Christopher M. Foley
Canadian Society for Civil Engineering
Flexible (simple) shear connections commonly used in steel-framed buildings are very economical and are relatively easy to fabricate. These connections are used for shear resistance, but recent studies have shown that they are capable of sustaining an interaction of rotational and axial load demand necessary for steel-framed building structures to help resist collapse in the event of unanticipated damage scenarios.
The objective of this paper is to outline and discuss an experimental effort designed to evaluate the robustness of single plate shear connections under a quasi-dynamic loading scenario simulating the loss of a central column. The experimental program included eleven …
Str-807: Ansys Modeling Of Post-Tensioned Steel Beam-Column Connections Under Cyclic Loading, Saber Moradi, M. Shahria Alam
Str-807: Ansys Modeling Of Post-Tensioned Steel Beam-Column Connections Under Cyclic Loading, Saber Moradi, M. Shahria Alam
Canadian Society for Civil Engineering
Permanent deformations in a steel moment resisting frame can be eliminated by using post-tensioned (PT) elements. This paper presents the development of three-dimensional finite element models of PT steel beam-column connection subassemblies. Knowing that there is limited experimental data in the literature on PT steel connections with top-and-seat angles, reliable finite element models can be used to investigate the load carrying behaviour of PT steel connections as well as producing more data for these new connections. In this paper, finite element modelling, meshing, and analysis are performed in the commercial software, ANSYS. The analysis includes geometric and material nonlinearities, pre-loaded …