Open Access. Powered by Scholars. Published by Universities.®

Chemical Engineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Cleveland State University

Discipline
Keyword
Publication Year
Publication
Publication Type

Articles 91 - 120 of 138

Full-Text Articles in Chemical Engineering

Analysis Of Thermal Effects In Infrared And Interference Microscopy: N-Butane-5a And Methanol-Ferrierite Systems, Lars Heinke, Christian Chmelik, Pavel Kortunov, Dhananjai B. Shah, S. Brandani, Douglas M. Ruthven, Jörg Kärger Aug 2007

Analysis Of Thermal Effects In Infrared And Interference Microscopy: N-Butane-5a And Methanol-Ferrierite Systems, Lars Heinke, Christian Chmelik, Pavel Kortunov, Dhananjai B. Shah, S. Brandani, Douglas M. Ruthven, Jörg Kärger

Chemical & Biomedical Engineering Faculty Publications

Recently, infrared and interference microscopy methods have been increasingly applied to measure internal concentration gradients and hence the uptake of different adsorbates in zeolite crystals. In contrast to conventional macroscopic batch uptake techniques, these microscopic/mesoscopic methods measure changes associated with single zeolite crystals. The analysis of data from these measurements to determine micropore diffusivities has been performed on the basis of the assumption that isothermal conditions prevail during both the adsorption and desorption experiments. This assumption is critically examined in this paper for the case of methanol diffusion in ferrierite crystals during adsorption and desorption to vacuum. It is shown …


Anwendung Von Interferenz- Und Ir-Mikroskopie Zur Charakterisierung Und Untersuchung Des Stofftransportes In Nanoporösen Materialien, Lars Heinke, Christian Chmelik, Pavel Kortunov, Sergey Vasenkov, Douglas M. Ruthven, Dhananjai B. Shah, Jörg Kärger Aug 2007

Anwendung Von Interferenz- Und Ir-Mikroskopie Zur Charakterisierung Und Untersuchung Des Stofftransportes In Nanoporösen Materialien, Lars Heinke, Christian Chmelik, Pavel Kortunov, Sergey Vasenkov, Douglas M. Ruthven, Dhananjai B. Shah, Jörg Kärger

Chemical & Biomedical Engineering Faculty Publications

Die Anwendung der Interferenz-Mikroskopie bedeutet einen entscheidenden Durchbruch in der Untersuchung des Stofftransports von Gastmolekülen in nanoporösen Wirtsmaterialien. Diese Technik ermöglicht die Beobachtung der zeitaufgelösten intrakristallinen Konzentrationsprofile, die durch eine Änderung des umgebenden Gasdruckes entstehen. Dieser Ansatz wurde zur Untersuchung von Adsorptions- und Desorptionsprozessen in verschiedenen Zeolithsystemen verwendet. Die Vorteile dieser Technik, vor allem wenn sie mit Infrarotabsorptionsmessungen kombiniert wird, werden an Hand der experimentellen Resultate des Methanol-in-Ferrierit-Systems illustriert.


Procedure To Quantify Biofilm Activity In Carriers Used In Wastewater Treatment Systems, James Bolton, Archana Tummala, Chirag Kapadia, Manoj Dandamudi, Joanne M. Belovich Nov 2006

Procedure To Quantify Biofilm Activity In Carriers Used In Wastewater Treatment Systems, James Bolton, Archana Tummala, Chirag Kapadia, Manoj Dandamudi, Joanne M. Belovich

Chemical & Biomedical Engineering Faculty Publications

A procedure is presented for evaluating and comparing the biological activity of biofilms attached to various biofilm carriers by measurement of the glucose consumption rate. This technique allows for the economical design and selection of small particulate biofilm carriers that will maximize substrate removal when used in industrial-scale fluidized bioreactors. Methods for ensuring reproducible results are described. To support the glucose consumption rate findings, biofilm dry weights were obtained at the conclusion of activity rate experiments, and scanning electron micrographs were taken to evaluate the presence of biofilm and to view surface characteristics. Fourteen different biofilm carriers were evaluated ranging …


Phosphate Reactions As Mechanisms Of High-Temperature Lubrication, Anitha Nagarajan, Carolina Garrido, Jorge E. Gatica, Wilfredo Morales May 2006

Phosphate Reactions As Mechanisms Of High-Temperature Lubrication, Anitha Nagarajan, Carolina Garrido, Jorge E. Gatica, Wilfredo Morales

Chemical & Biomedical Engineering Faculty Publications

One of the major problems preventing the operation of advanced gas turbine engines at higher temperatures is the inability of currently used liquid lubricants to survive at these higher temperatures under friction and wear conditions. Current state-of-the-art organic liquid lubricants rapidly degrade at temperatures above 300 °C; hence some other form of lubrication is necessary. Vapor-phase lubrication is a promising new technology for high-temperature lubrication. This lubrication method employs a liquid phosphate ester that is vaporized and delivered to bearings or gears; the vapor reacts with the metal surfaces, generating a solid lubricious film that has proven very stable at …


Adsorption Of Lactic Acid From Fermentation Broth And Aqueous Solutions On Zeolite Molecular Sieves, Isam H. Aljundi, Joanne M. Belovich, Orhan Talu Sep 2005

Adsorption Of Lactic Acid From Fermentation Broth And Aqueous Solutions On Zeolite Molecular Sieves, Isam H. Aljundi, Joanne M. Belovich, Orhan Talu

Chemical & Biomedical Engineering Faculty Publications

The recovery of lactic acid from fermentation broth and aqueous solutions was studied by adsorption on Silicalite molecular sieves. Batch experiments were used to measure the adsorption isotherms of the lactic acid on Silicalite. A linear correlation was found for both solutions. Silicalite showed a higher adsorptive capacity in the case of the aqueous solution than that of the fermentation broth. Henry’s constants were estimated as Formula Not Shown and Formula Not Shown for the aqueous and broth solutions, respectively. The effect of temperature on adsorption was also studied in batch mode. Henry’s constant dependency on …


Single-Collector Experiments And Modeling Of Acoustically Aided Mesh Filtration, Michael T. Grossner, Donald L. Feke, Joanne M. Belovich Jun 2005

Single-Collector Experiments And Modeling Of Acoustically Aided Mesh Filtration, Michael T. Grossner, Donald L. Feke, Joanne M. Belovich

Chemical & Biomedical Engineering Faculty Publications

A model for the motion of particles driven by acoustic and hydrodynamic effects in the vicinity of a cylindrical collector has been previously reported. This trajectory model was developed to describe the essential physics that underlies an ultrasonically aided particle-filtration process in which a porous mesh is used to capture particles two orders of magnitude smaller than the pore size. To validate this trajectory model, experiments were performed to elucidate the detailed motion of particles in the neighborhood of a single cylindrical collector. Images of 54-μm-diameter polystyrene particles in aqueous suspension responding to acoustic and hydrodynamic forces were …


Transport Analysis And Model For The Performance Of An Ultrasonically Enhanced Filtration Process, Michael T. Grossner, Joanne M. Belovich, Donald L. Feke Jun 2005

Transport Analysis And Model For The Performance Of An Ultrasonically Enhanced Filtration Process, Michael T. Grossner, Joanne M. Belovich, Donald L. Feke

Chemical & Biomedical Engineering Faculty Publications

This paper presents an analysis of a filtration technique that uses ultrasound to aid the collection of small particles (tens of microns in diameter) from suspension. In this method, particles are retained within a porous mesh that is subjected to a resonant ultrasonic field, even though the pore size of the mesh is two orders of magnitude greater than the particle diameter. The role of acoustic forces in driving the retention phenomena has previously been studied on a micro-scale, which included modeling and experimental verification of particle motion and trapping near a single element of the mesh. Here, we build …


Blood Flow Measurements With Magnetic Resonance Phase Velocity Mapping, George P. Chatzimavroudis Apr 2005

Blood Flow Measurements With Magnetic Resonance Phase Velocity Mapping, George P. Chatzimavroudis

Chemical & Biomedical Engineering Faculty Publications

Magnetic resonance (MR) phase velocity mapping (PVM) is a non-invasive technique that can measure the flow velocity in any spatial direction in an imaging slice. This technique has wide application in the clinical field in quantifying blood flow, as well as in non-biomedical areas. This review describes the value and/or potential of MR PVM as a diagnostic/monitoring technique in heart valve regurgitation and in the total cavo-pulmonary connection. A single slice placed in the aortic root can accurately quantify the aortic regurgitant volume. A multi-slice control volume method has high potential for the quantification of the mitral regurgitant volume. …


Fractionation Of Cell Mixtures Using Acoustic And Laminar Flow Fields, Manoj Kumar, Donald L. Feke, Joanne M. Belovich Jan 2005

Fractionation Of Cell Mixtures Using Acoustic And Laminar Flow Fields, Manoj Kumar, Donald L. Feke, Joanne M. Belovich

Chemical & Biomedical Engineering Faculty Publications

A fractionation method applicable to different populations of cells in a suspension is reported. The separation was accomplished by subjecting the suspension to a resonant ultrasonic field and a laminar flow field propagating in orthogonal directions within a thin, rectangular chamber. Steady, laminar flow transports the cell suspension along the chamber, while the ultrasonic field causes the suspended cells to migrate to the mid-plane of the chamber at rates related to their size and physical properties. A thin flow splitter positioned near the outlet divides the effluent cell suspension into two product streams, thereby allowing cells that respond faster to …


Relationship Between The Extent Of Non-Viable Myocardium And Regional Left Ventricular Function In Chronic Ischemic Heart Disease, Arunark Kolipaka, George P. Chatzimavroudis, Richard D. White, Michael L. Lieber, Randolph M. Setser Jan 2005

Relationship Between The Extent Of Non-Viable Myocardium And Regional Left Ventricular Function In Chronic Ischemic Heart Disease, Arunark Kolipaka, George P. Chatzimavroudis, Richard D. White, Michael L. Lieber, Randolph M. Setser

Chemical & Biomedical Engineering Faculty Publications

Purpose. To define the relationship between left ventricular (LV) regional contractile function and the extent of myocardial scar in patients with chronic ischemic heart disease and multi-vessel coronary artery disease. Methods. Twenty-three patients with chronic ischemic heart disease and 5 healthy volunteers underwent magnetic resonance imaging (MRI). In patients, the relative area ( Percent Scar) and transmural extent (Transmurality) of myocardial infarction were computed from short-axis delayed enhancement images. In each image, myocardial segments were categorized based on the extent of infarction they contained, with 6 categories each for Percent Scar and Transmurality: normal, from healthy volunteers; and 0%; 1–25%, …


Fast Measurements Of Flow Through Mitral Regurgitant Orifices With Magnetic Resonance Phase Velocity Mapping, Haosen Zhang, Sandra S. Halliburton, Richard D. White, George P. Chatzimavroudis Dec 2004

Fast Measurements Of Flow Through Mitral Regurgitant Orifices With Magnetic Resonance Phase Velocity Mapping, Haosen Zhang, Sandra S. Halliburton, Richard D. White, George P. Chatzimavroudis

Chemical & Biomedical Engineering Faculty Publications

Magnetic-resonance (MR) phase velocity mapping (PVM) shows promise in measuring the mitral regurgitant volume. However, in its conventional nonsegmented form, MR-PVM is slow and impractical for clinical use. The aim of this study was to evaluate the accuracy of rapid, segmented k-spaceMR-PVM in quantifying the mitral regurgitant flow through a control volume (CV) method. Two segmented MR-PVM schemes, one with seven (seg-7) and one with nine (seg-9) lines per segment, were evaluated in acrylic regurgitant mitral valve models under steady and pulsatile flow. A nonsegmented (nonseg) MR-PVM acquisition was also performed for reference. The segmented acquisitions were …


Heat Transfer In A Thin Liquid Film In The Presence Of An Electric Field, Rama Subba Reddy Gorla, Jorge E. Gatica, Bahman Ghorashi, Pijarn Ineure, Larry W. Byrd May 2004

Heat Transfer In A Thin Liquid Film In The Presence Of An Electric Field, Rama Subba Reddy Gorla, Jorge E. Gatica, Bahman Ghorashi, Pijarn Ineure, Larry W. Byrd

Chemical & Biomedical Engineering Faculty Publications

Heat transfer enhancement in an evaporating thin liquid film utilizing a electric field under isothermal interfacial condition is presented. A new mathematical model subjected to van der Waals attractive forces, capillary pressure, and an electric field is developed to describe the heat transfer enhancement in the evaporating thin liquid film. The effect of the electrostatic field on the curvature of the thin film, evaporative flux, pressure gradient distribution, heat flux, and heat transfer coefficient in the thin film is presented. The results show that applying an electric field can enhance heat transfer in a thin liquid film significantly. in addition, …


Retention And Viability Characteristics Of Mammalian Cells In An Acoustically Driven Polymer Mesh, Zhaowei Wang, Paul Grabenstetter, Donald L. Feke, Joanne M. Belovich Jan 2004

Retention And Viability Characteristics Of Mammalian Cells In An Acoustically Driven Polymer Mesh, Zhaowei Wang, Paul Grabenstetter, Donald L. Feke, Joanne M. Belovich

Chemical & Biomedical Engineering Faculty Publications

A processing approach for the collection and retention of mammalian cells within a high porosity polyester mesh having millimeter-sized pores has been studied. Cell retention occurs via energizing the mesh with a low intensity, resonant acoustic field. The resulting acoustic field induces the interaction of cells with elements of the mesh or with each other and effectively prevents the entrainment of cells in the effluent stream. Experiments involving aqueous suspensions of polystyrene particles were used to provide benchmark data on the performance of the acoustic retention cell. Experiments using mouse hybridoma cells showed that retention densities of over 1.5 × …


A Mushy-Zone Rayleigh Number To Describe Interdendritic Convection During Directional Solidification Of Hypoeutectic Pb-Sb And Pb-Sn Alloys, Surendra N. Tewari, R. Tiwari Oct 2003

A Mushy-Zone Rayleigh Number To Describe Interdendritic Convection During Directional Solidification Of Hypoeutectic Pb-Sb And Pb-Sn Alloys, Surendra N. Tewari, R. Tiwari

Chemical & Biomedical Engineering Faculty Publications

Based on measurements of the specific dendrite surface area (S-nu), fraction of interdendritic liquid (phi), and primary dendrite spacing (lambda(1)) on transverse sections in a range of directionally solidified hypoeutectic Pb-Sb and Pb-Sn alloys that were grown at thermal gradients varying from 10 to 197 K cm(-1) and growth speeds ranging from 2 to 157 mum s(-1), it is observed that S-nu = lambda(1)(-1) S*(-0.33) (3.38 - 3.29 phi + 8.85 phi(2)), where S* = D-l G(eff)/V m(1) C-o (k - 1)/k, with D-l being the solutal diffusivity in the melt, G(eff) being the effective thermal gradient, V being the …


Directional Solidification And Convection In Small Diameter Crucibles, Jun Chen, P. K. Sung, D. R. Poirier, H. C. De Groh Iii Sep 2003

Directional Solidification And Convection In Small Diameter Crucibles, Jun Chen, P. K. Sung, D. R. Poirier, H. C. De Groh Iii

Chemical & Biomedical Engineering Faculty Publications

Pb–2.2 wt.% Sb alloy was directionally solidified in 1, 2, 3 and 7 mm diameter crucibles. Pb–Sb alloy presents a solutally unstable case. Under plane–front conditions, the resulting macrosegregation along the solidified length indicates that convection persists even in the 1 mm diameter crucible. Al–2 wt.% Cu alloy was directionally solidified because this alloy was expected to be stable with respect to convection. Nevertheless, the resulting macrosegregation pattern and the microstructure in solidified examples indicated the presence of convection. Simulations performed for both alloys show that convection persists for crucibles as small as 0.6 mm of diameter …


Gibbs Dividing Surface And Helium Adsorption, Sasidhar Gumma, Orhan Talu Mar 2003

Gibbs Dividing Surface And Helium Adsorption, Sasidhar Gumma, Orhan Talu

Chemical & Biomedical Engineering Faculty Publications

All adsorption data is based on the definition of Gibbs dividing surface, which is a purely mathematical transformation. Adsorption measurements in microporous solids necessitate experimental determination of the dividing surface. An international protocol does not exist on how to perform this important measurement. Commonly, helium is assumed not to adsorb and used as a probe molecule for this measurement. Each experimentalist chooses an arbitrary set of conditions, often without even disclosing them, which adds to the confusion in adsorption literature. Here, a self-consistent method for the analysis of helium data is proposed which does not assume non-adsorbing helium …


Single Fiber Model Of Particle Retention In An Acoustically Driven Porous Mesh, Michael T. Grossner, Alan E. Penrod, Joanne M. Belovich, Donald L. Feke Mar 2003

Single Fiber Model Of Particle Retention In An Acoustically Driven Porous Mesh, Michael T. Grossner, Alan E. Penrod, Joanne M. Belovich, Donald L. Feke

Chemical & Biomedical Engineering Faculty Publications

A method for the capture of small particles (tens of microns in diameter) from a continuously flowing suspension has recently been reported. This technique relies on a standing acoustic wave resonating in a rectangular chamber filled with a high-porosity mesh. Particles are retained in this chamber via a complex interaction between the acoustic field and the porous mesh. Although the mesh has a pore size two orders of magnitude larger than the particle diameter, collection efficiencies of 90% have been measured. A mathematical model has been developed to understand the experimentally observed phenomena and to be able to predict filtration …


The Effect Of Convection On Disorder In Primary Cellular And Dendritic Arrays, R. Trivedi, P. Mazumder, Surendra N. Tewari Dec 2002

The Effect Of Convection On Disorder In Primary Cellular And Dendritic Arrays, R. Trivedi, P. Mazumder, Surendra N. Tewari

Chemical & Biomedical Engineering Faculty Publications

Directional solidification studies have been carried out to characterize the spatial disorder in the arrays of cells and dendrites. Different factors that cause array disorder are investigated experimentally and analyzed numerically. In addition to the disorder resulting from the fundamental selection of a range of primary spacings under given experimental conditions, a significant variation in primary spacings is shown to occur in bulk samples due to convection effects, especially at low growth velocities. The effect of convection on array disorder is examined through directional solidification studies in two different alloy systems, Pb-Sn and Al-Cu. A detailed analysis of the spacing …


Accurate Quantification Of Steady And Pulsatile Flow With Segmented K-Space Magnetic Resonance Velocimetry, Haosen Zhang, Sandra S. Halliburton, James R. Moore, Orlando P. Simonetti, Paulo R. Schvartzman, Richard D. White, George P. Chatzimavroudis Sep 2002

Accurate Quantification Of Steady And Pulsatile Flow With Segmented K-Space Magnetic Resonance Velocimetry, Haosen Zhang, Sandra S. Halliburton, James R. Moore, Orlando P. Simonetti, Paulo R. Schvartzman, Richard D. White, George P. Chatzimavroudis

Chemical & Biomedical Engineering Faculty Publications

Conventional non-segmented magnetic resonance phase velocity mapping (MRPVM) is an accurate but relatively slow velocimetric technique. Therefore, the aim of this study was to evaluate the accuracy of the much faster segmented k-space MRPVM in quantifying flow. The axial velocity was measured in four straight tubes (inner diameter: 5.6–26.2 mm), using a segmented MRPVM sequence with seven lines of k-space per segment. The flow rate and flow volume were accurately quantified (errorssteady (r2=0.99) and pulsatile flow (r2=0.98), respectively. The measured velocity profiles and flow rates from the segmented sequence agreed …


Ultrafast Flow Quantification With Segmented K-Space Magnetic Resonance Phase Velocity Mapping, Haosen Zhang, Sandra S. Halliburton, James R. Moore, Orlando P. Simonetti, Paulo R. Schvartzman, Richard D. White, George P. Chatzimavroudis Jan 2002

Ultrafast Flow Quantification With Segmented K-Space Magnetic Resonance Phase Velocity Mapping, Haosen Zhang, Sandra S. Halliburton, James R. Moore, Orlando P. Simonetti, Paulo R. Schvartzman, Richard D. White, George P. Chatzimavroudis

Chemical & Biomedical Engineering Faculty Publications

Magnetic resonance (MR) phase-velocity mapping (PVM) is routinely being used clinically to measure blood flow velocity. Conventional nonsegmented PVM is accurate but relatively slow (3–5 min per measurement). Ultrafast k-space segmented PVM offers much shorter acquisitions (on the order of seconds instead of minutes). The aim of this study was to evaluate the accuracy of segmented PVM in quantifying flow from through-plane velocity measurements. Experiments were performed using four straight tubes (inner diameter of 5.6–26.2 mm), under a variety of steady (1.7–200 ml/s) and pulsatile (6–90 ml/cycle) flow conditions. Two different segmented PVM schemes were …


Molecular Simulation Of Adsorption: Gibbs Dividing Surface And Comparison With Experiment, Orhan Talu, Alan L. Myers May 2001

Molecular Simulation Of Adsorption: Gibbs Dividing Surface And Comparison With Experiment, Orhan Talu, Alan L. Myers

Chemical & Biomedical Engineering Faculty Publications

At low temperature near the normal boiling point, computer simulations of adsorption of gases can be compared directly with experiment. However, for adsorptive gas separations in which the gas is adsorbed near or above its critical temperature, absolute simulation variables must be converted to excess variables for comparison with experiment. The conversion of absolute to excess variables requires the helium pore volume of the adsorbent. Lennard-Jones potential parameters for helium gas molecules interacting with the oxygen atoms of silicalite are ε/k = 28.0 K and σ = 2.952 Å. The helium pore volume of silicalite is 0.175 cm …


Wear And Friction Behavior Of Pressure Infiltration Cast Copper-Carbon Composites, G. Göller, D. P. Koty, M. Singh, A. Tekin Apr 2001

Wear And Friction Behavior Of Pressure Infiltration Cast Copper-Carbon Composites, G. Göller, D. P. Koty, M. Singh, A. Tekin

Chemical & Biomedical Engineering Faculty Publications

Metal matrix composites, prepared by pressure infiltration casting of copper base alloy into 2 types of microporous carbon preforms, one with 100% amorphous carbon and the other containing 40 wt pct. graphite and 60 wt pct. amorphous carbon, have been examined for their wear and friction behavior under ambient conditions using a pin-on-plate reciprocating wear tester. Micro-structural characterization of tribo-surfaces has been carried out. The thin carbon films formed on the tribo-surface reduced the friction coefficient and wear for the composites, especially at low loads on the pin. Adhesive wear observed on the tribo-surface promoted wear and …


Evaluation Of The Precision Of Magnetic Resonance Phase Velocity Mapping For Blood Flow Measurements, George P. Chatzimavroudis, John N. Oshinski, Robert H. Franch, Peter G. Walker, Ajit P. Yoganathan, Roderic I. Pettigrew Jan 2001

Evaluation Of The Precision Of Magnetic Resonance Phase Velocity Mapping For Blood Flow Measurements, George P. Chatzimavroudis, John N. Oshinski, Robert H. Franch, Peter G. Walker, Ajit P. Yoganathan, Roderic I. Pettigrew

Chemical & Biomedical Engineering Faculty Publications

Evaluating the in vivo accuracy of magnetic resonance phase velocity mapping (PVM) is not straightforward because of the absence of a validated clinical flow quantification technique. The aim of this study was to evaluate PVM by investigating its precision, both in vitro and in vivo, in a 1.5 Tesla scanner. In the former case, steady and pulsatile flow experiments were conducted using an aortic model under a variety of flow conditions (steady: 0.1–5.5 L/min; pulsatile: 10–75 mL/cycle). In the latter case, PVM measurements were taken in the ascending aorta of ten subjects, seven of which had aortic regurgitation. Each velocity …


Time-Varying System Identification Using Modulating Functions And Spline Models With Application To Bio-Processes, Sridhar Ungarala, Tomas B. Co Dec 2000

Time-Varying System Identification Using Modulating Functions And Spline Models With Application To Bio-Processes, Sridhar Ungarala, Tomas B. Co

Chemical & Biomedical Engineering Faculty Publications

Time dependent parameters are frequently encountered in many real processes which need to be monitored for process modeling, control and supervision purposes. Modulating functions methods are especially suitable for this task because they use the original continuous-time differential equations and avoid differentiation of noisy signals. Among the many versions of the method available, Pearson–Lee method offers a computationally efficient alternative. In this paper, Pearson–Lee method is generalized for non-stationary continuous-time systems and the on-line version is developed. The time dependent parameters are modeled as polynomial splines inside a moving data window and recursion formulae using shifting properties of …


A Multiscale, Bayesian And Error-In-Variables Approach For Linear Dynamic Data Rectification, Sridhar Ungarala, Bhavik R. Bakshi Jul 2000

A Multiscale, Bayesian And Error-In-Variables Approach For Linear Dynamic Data Rectification, Sridhar Ungarala, Bhavik R. Bakshi

Chemical & Biomedical Engineering Faculty Publications

A multiscale approach to data rectification is proposed for data containing features with different time and frequency localization. Noisy data are decomposed into contributions at multiple scales and a Bayesian optimization problem is solved to rectify the wavelet coefficients at each scale. A linear dynamic model is used to constrain the optimization problem, which facilitates an error-in variables (EIV) formulation and reconciles all measured variables. Time-scale recursive algorithms are obtained by propagating the prior with temporal and scale models. The multi-scale Kalman filter is a special case of the proposed Bayesian EIV approach.


Reversal Flow In Fixed-Bed Reactors Operating Under Reaction-Regeneration Cycles, Daniel O. Borio, Noemi S. Schbib, Jorge E. Gatica May 1999

Reversal Flow In Fixed-Bed Reactors Operating Under Reaction-Regeneration Cycles, Daniel O. Borio, Noemi S. Schbib, Jorge E. Gatica

Chemical & Biomedical Engineering Faculty Publications

The unsteady state simulation of a set of industrial fixed-bed reactors is presented. The catalytic dehydrogenation of 1-butene into 1-3-butadiene is selected as case study. These reactors operate under reaction-regeneration cycles. Each stage of the process, i.e., dehydrogenation (deactivation by coking), steam purge, oxidative regeneration and evacuation, is simulated by means of the corresponding dynamic model. The kinetic parameters used in the dehydrogenation and regeneration stages for a Cr2O3/Al2O3 catalyst are taken from the literature. The performance of the reactors is investigated for two different operation modes: conventional …


Editorial, Orhan Talu, Shivaji Sircar Mar 1999

Editorial, Orhan Talu, Shivaji Sircar

Chemical & Biomedical Engineering Faculty Publications

No abstract provided.


Copper Alloy-Impregnated Carbon-Carbon Hybrid Composites For Electronic Packaging Applications, S. K. Datta, Surendra N. Tewari, Jorge E. Gatica, W. Shih, L. Bentsen Jan 1999

Copper Alloy-Impregnated Carbon-Carbon Hybrid Composites For Electronic Packaging Applications, S. K. Datta, Surendra N. Tewari, Jorge E. Gatica, W. Shih, L. Bentsen

Chemical & Biomedical Engineering Faculty Publications

Porous carbon-carbon preforms, based on three-dimensional networks of PAN (Polyacrylonitrile)-based carbon fibers and various volume fractions of chemical vapor-deposited (CVD) carbon, were impregnated by oxygen-free, high-conductivity (OFHC) Cu, Cu-6Si-0.9Cr, and Cu-0.3Si-0.3Cr (wt pct) alloys by pressure infiltration casting. The obtained composites were characterized for their coefficient of thermal expansion (CTE) and thermal conductivity (K) along the through-thickness and two in-plane directions. One composite, with a 28 vol pct Cu-0.3Si-0.3Cr alloy, showed outstanding potential for thermal management applications in electronic applications. This composite exhibited approximately isotropic thermal expansion properties (CTE = 4 to 6.5 ppm/K) and thermal conductivities (k greater than …


Diffusivities Of N-Alkanes In Silicalite By Steady-State Single-Crystal Membrane Technique, Orhan Talu, Matthew S. Sun, Dhananjai B. Shah Mar 1998

Diffusivities Of N-Alkanes In Silicalite By Steady-State Single-Crystal Membrane Technique, Orhan Talu, Matthew S. Sun, Dhananjai B. Shah

Chemical & Biomedical Engineering Faculty Publications

A novel experimental technique that measures the diffusive flux through a single-crystal membrane (SCM) was developed and tested. Unlike all other macroscopic techniques that depend on a transient response, SCM is used under steady-state conditions, which results in a wide range of applicability from 10−2 to 10−11 cm2/s. Phenomenological equations for the steady-state data analysis were developed. The variation of driving force over the diffusion path is included in the model. As required by thermodynamics, the micropore concentration is given as a function of surface-excess amount adsorbed and gas density. The membrane configuration measures diffusivity in …


Dynamic Analysis Of Unidirectional Pressure Infiltration Of Porous Preforms By Pure Metals, Dhiman K. Biswas, Jorge E. Gatica, Surendra N. Tewari Jan 1998

Dynamic Analysis Of Unidirectional Pressure Infiltration Of Porous Preforms By Pure Metals, Dhiman K. Biswas, Jorge E. Gatica, Surendra N. Tewari

Chemical & Biomedical Engineering Faculty Publications

Unidirectional pressure infiltration of porous preforms by molten metals is investigated numerically. A phenomenological model to describe fluid flow and transport phenomena during infiltration of fibrous preforms by a metal is formulated. The model describes the dynamics of the infiltration process, the temperature distribution, and solid fraction distribution. The numerical results are compared against classical asymptotic analyses and experimental results. This comparison shows that end effects may become important and render asymptotic results unreliable for realistic samples. Fiber volume fraction and initial temperature appear as the factors most strongly influencing infiltration. Metal superheating affects not only the length of the …