Open Access. Powered by Scholars. Published by Universities.®
Bioimaging and Biomedical Optics Commons™
Open Access. Powered by Scholars. Published by Universities.®
- Discipline
-
- Medicine and Health Sciences (18)
- Life Sciences (10)
- Medical Specialties (9)
- Physical Sciences and Mathematics (9)
- Electrical and Computer Engineering (6)
-
- Analytical, Diagnostic and Therapeutic Techniques and Equipment (5)
- Biomedical Devices and Instrumentation (5)
- Computer Sciences (5)
- Biomedical (4)
- Molecular, Cellular, and Tissue Engineering (4)
- Other Biomedical Engineering and Bioengineering (4)
- Anatomy (3)
- Bioelectrical and Neuroengineering (3)
- Cardiovascular System (3)
- Cell and Developmental Biology (3)
- Medical Sciences (3)
- Neuroscience and Neurobiology (3)
- Artificial Intelligence and Robotics (2)
- Biochemistry, Biophysics, and Structural Biology (2)
- Biological Engineering (2)
- Biotechnology (2)
- Cancer Biology (2)
- Chemistry (2)
- Diseases (2)
- Engineering Science and Materials (2)
- Investigative Techniques (2)
- Materials Science and Engineering (2)
- Institution
-
- University of Kentucky (8)
- University of Arkansas, Fayetteville (6)
- Washington University in St. Louis (5)
- Brigham Young University (3)
- Dartmouth College (3)
-
- Purdue University (3)
- Western University (3)
- California Polytechnic State University, San Luis Obispo (2)
- City University of New York (CUNY) (2)
- Old Dominion University (2)
- University of Louisville (2)
- Wayne State University (2)
- Louisiana State University (1)
- Michigan Technological University (1)
- Missouri University of Science and Technology (1)
- University of Central Florida (1)
- University of South Florida (1)
- Virginia Commonwealth University (1)
- Keyword
-
- MRI (4)
- Cancer (2)
- Cardiovascular magnetic resonance (2)
- DENSE (2)
- Image reconstruction (2)
-
- Imaging (2)
- In vivo (2)
- Magnetic Resonance Imaging (2)
- Simulation (2)
- 2-manifold mesh (1)
- 2-simplex mesh (1)
- 7 Tesla MRI (1)
- ADHD (1)
- ADVANTG (1)
- ASETS (1)
- Absorption (1)
- Adult (1)
- Aged (1)
- Aging (1)
- Algorithm (1)
- Alzheimer’s disease (1)
- Ambulatory blood pressure monitoring (1)
- Animals (1)
- Aphasia stroke heads (1)
- Artificial neural networks (1)
- Automatic image segmentation (1)
- Balun (1)
- Band (1)
- Bevacizumab (1)
- Bioinstrumentation (1)
- Publication
-
- Biomedical Engineering Undergraduate Honors Theses (6)
- McKelvey School of Engineering Graduate Student Theses & Dissertations (5)
- Biomedical Engineering Faculty Publications (3)
- Biomedical Engineering Western Regional Conference (3)
- Dartmouth Scholarship (3)
-
- The Summer Undergraduate Research Fellowship (SURF) Symposium (3)
- Electronic Theses and Dissertations (2)
- Computational Modeling & Simulation Engineering Theses & Dissertations (1)
- Computer Engineering (1)
- Dissertations and Theses (1)
- Dissertations, Master's Theses and Master's Reports (1)
- Electrical & Computer Engineering Theses & Dissertations (1)
- Electrical and Computer Engineering Faculty Publications (1)
- Honors Undergraduate Theses (1)
- LSU Doctoral Dissertations (1)
- Master's Theses (1)
- Masters Theses (1)
- Mechanical Engineering Faculty Publications (1)
- Neurology Faculty Publications (1)
- Physical Therapy Faculty Publications (1)
- Physiology and Pharmacology Publications (1)
- Publications and Research (1)
- Research Opportunities for Engineering Undergraduates (ROEU) Program 2016-17 (1)
- Robarts Imaging Publications (1)
- Theses and Dissertations (1)
- Theses and Dissertations--Biomedical Engineering (1)
- USF Tampa Graduate Theses and Dissertations (1)
- Wayne State University Dissertations (1)
- Western Research Forum (1)
- Publication Type
Articles 31 - 47 of 47
Full-Text Articles in Bioimaging and Biomedical Optics
A Novel Mra-Based Framework For The Detection Of Changes In Cerebrovascular Blood Pressure., Yitzhak Atakilt Gebru
A Novel Mra-Based Framework For The Detection Of Changes In Cerebrovascular Blood Pressure., Yitzhak Atakilt Gebru
Electronic Theses and Dissertations
Background: High blood pressure (HBP) affects 75 million adults and is the primary or contributing cause of mortality in 410,000 adults each year in the United States. Chronic HBP leads to cerebrovascular changes and is a significant contributor for strokes, dementia, and cognitive impairment. Non-invasive measurement of changes in cerebral vasculature and blood pressure (BP) may enable physicians to optimally treat HBP patients. This manuscript describes a method to non-invasively quantify changes in cerebral vasculature and BP using Magnetic Resonance Angiography (MRA) imaging.
Methods: MRA images and BP measurements were obtained from patients (n=15, M=8, F=7, Age= 49.2 …
Optimization Of Fluorescent Imaging In The Operating Room Through Pulsed Acquisition And Gating To Ambient Background Cycling, Kristian J. Sexton, Yan Zhao, Scott C. Davis, Shudong Jiang, Brian Pogue
Optimization Of Fluorescent Imaging In The Operating Room Through Pulsed Acquisition And Gating To Ambient Background Cycling, Kristian J. Sexton, Yan Zhao, Scott C. Davis, Shudong Jiang, Brian Pogue
Dartmouth Scholarship
The design of fluorescence imaging instruments for surgical guidance is rapidly evolving, and a key issue is to efficiently capture signals with high ambient room lighting. Here, we introduce a novel time-gated approach to fluorescence imaging synchronizing acquisition to the 120 Hz light of the room, with pulsed LED excitation and gated ICCD detection. It is shown that under bright ambient room light this technique allows for the detection of physiologically relevant nanomolar fluorophore concentrations, and in particular reduces the light fluctuations present from the room lights, making low concentration measurements more reliable. This is particularly relevant for the light …
A Novel Hybrid Imaging System To Aid In Surgical Decision Making, Lawrence Yip, Madeleine Van De Kleut, Ivan Kosik, Astrid Chamson-Reig, Jeffrey Jl Carson
A Novel Hybrid Imaging System To Aid In Surgical Decision Making, Lawrence Yip, Madeleine Van De Kleut, Ivan Kosik, Astrid Chamson-Reig, Jeffrey Jl Carson
Western Research Forum
Background:
Breast cancer accounts for 25% of all cancer cases among women. In breast-conserving surgery, a common treatment, the tumour is excised with a healthy tissue margin. However, detection of the margin can be difficult. Current techniques to guide excision are often insufficient, and re-excision can occur up to 25% of the time.
Methods:
Photoacoustic imaging is a hybrid imaging modality that combines the advantages of optical imaging and ultrasound while using safe non-ionizing light. This project involves the development of a novel imaging system with a new scanner design to overcome common limitations and provide images to aid in …
Using A Respiratory Navigator Significantly Reduces Variability When Quantifying Left Ventricular Torsion With Cardiovascular Magnetic Resonance, Sean M. Hamlet, Christopher M. Haggerty, Jonathan D. Suever, Gregory J. Wehner, Kristin N. Andres, David K. Powell, Richard J. Charnigo, Brandon K. Fornwalt
Using A Respiratory Navigator Significantly Reduces Variability When Quantifying Left Ventricular Torsion With Cardiovascular Magnetic Resonance, Sean M. Hamlet, Christopher M. Haggerty, Jonathan D. Suever, Gregory J. Wehner, Kristin N. Andres, David K. Powell, Richard J. Charnigo, Brandon K. Fornwalt
Electrical and Computer Engineering Faculty Publications
Background: Left ventricular (LV) torsion is an important indicator of cardiac function that is limited by high inter-test variability (50% of the mean value). We hypothesized that this high inter-test variability is partly due to inconsistent breath-hold positions during serial image acquisitions, which could be significantly improved by using a respiratory navigator for cardiovascular magnetic resonance (CMR) based quantification of LV torsion.
Methods: We assessed respiratory-related variability in measured LV torsion with two distinct experimental protocols. First, 17 volunteers were recruited for CMR with cine displacement encoding with stimulated echoes (DENSE) in which a respiratory navigator was used to measure …
Directed Acyclic Graph Continuous Max-Flow Image Segmentation For Unconstrained Label Orderings, John Sh Baxter, Martin Rajchl, A. Jonathan Mcleod, Jing Yuan, Terry M. Peters
Directed Acyclic Graph Continuous Max-Flow Image Segmentation For Unconstrained Label Orderings, John Sh Baxter, Martin Rajchl, A. Jonathan Mcleod, Jing Yuan, Terry M. Peters
Robarts Imaging Publications
Label ordering, the specification of subset–superset relationships for segmentation labels, has been of increasing interest in image segmentation as they allow for complex regions to be represented as a collection of simple parts. Recent advances in continuous max-flow segmentation have widely expanded the possible label orderings from binary background/foreground problems to extendable frameworks in which the label ordering can be specified. This article presents Directed Acyclic Graph Max-Flow image segmentation which is flexible enough to incorporate any label ordering without constraints. This framework uses augmented Lagrangian multipliers and primal–dual optimization to develop a highly parallelized solver implemented using GPGPU. This …
Ex Vivo Bio-Orthogonal Mri Imaging – A Novel Method Proposed For Metastatic Cancer Detection, Tanner Ravsten, William G. Pitt, Neal K. Bangerter, Randy Hartley, Forrest Howell, Jessica Doud
Ex Vivo Bio-Orthogonal Mri Imaging – A Novel Method Proposed For Metastatic Cancer Detection, Tanner Ravsten, William G. Pitt, Neal K. Bangerter, Randy Hartley, Forrest Howell, Jessica Doud
Biomedical Engineering Western Regional Conference
Bio-orthogonal detection of metastatic cancer using MRI, Gd Iron-oxide contrast agents using T1 T2* scans
Mri Field Mapping Using Bssfp Elliptical Signal Model, Joseph Valentine, Meredith Taylor, Steven Whitaker, Michael Hoff, Neal Bangerter
Mri Field Mapping Using Bssfp Elliptical Signal Model, Joseph Valentine, Meredith Taylor, Steven Whitaker, Michael Hoff, Neal Bangerter
Biomedical Engineering Western Regional Conference
MRI, Field Mapping, bSSFP, ssfp, Elliptical Signal model, ellipse, phase unwrapping
Engineering Fret Biosensors For Microrna Presence/Absence Analysis, Nicholas E. Larkey, Sean M. Burrows
Engineering Fret Biosensors For Microrna Presence/Absence Analysis, Nicholas E. Larkey, Sean M. Burrows
Biomedical Engineering Western Regional Conference
No abstract provided.
Resting State Functional Network Disruptions In A Kainic Acid Model Of Temporal Lobe Epilepsy., Ravnoor Singh Gill, Seyed M Mirsattari, L Stan Leung
Resting State Functional Network Disruptions In A Kainic Acid Model Of Temporal Lobe Epilepsy., Ravnoor Singh Gill, Seyed M Mirsattari, L Stan Leung
Physiology and Pharmacology Publications
We studied the graph topological properties of brain networks derived from resting-state functional magnetic resonance imaging in a kainic acid induced model of temporal lobe epilepsy (TLE) in rats. Functional connectivity was determined by temporal correlation of the resting-state Blood Oxygen Level Dependent (BOLD) signals between two brain regions during 1.5% and 2% isoflurane, and analyzed as networks in epileptic and control rats. Graph theoretical analysis revealed a significant increase in functional connectivity between brain areas in epileptic than control rats, and the connected brain areas could be categorized as a limbic network and a default mode network (DMN). The …
Automatic Optimum Atlas Selection For Multi-Atlas Image Segmentation Using Joint Label Fusion, Kofi Agyeman
Automatic Optimum Atlas Selection For Multi-Atlas Image Segmentation Using Joint Label Fusion, Kofi Agyeman
Dissertations and Theses
Multi-atlas image segmentation using label fusion is one of the most accurate state of the art image segmentation techniques available for biomedical imaging applications. Motivated to achieve higher image segmentation accuracy, reduce computational costs and a continuously increasing atlas data size, a robust framework for optimum selection of atlases for label fusion is vital. Although believed not to be critical for weighted label fusion techniques by some works (Sabuncu, M. R. et al., 2010, [1]), others have shown that appropriate atlas selection has several merits and can improve multi-atlas image segmentation accuracy (Aljabar et al., 2009, [2], Van de Velde …
Utility Of Ultrasound/Photoacoustic Imaging For Accurate Catheter Tracking And Temperature Monitoring During Endovenous Laser Ablation, Ayushi Jharia, Keerthana Palani, Yan Yan
Utility Of Ultrasound/Photoacoustic Imaging For Accurate Catheter Tracking And Temperature Monitoring During Endovenous Laser Ablation, Ayushi Jharia, Keerthana Palani, Yan Yan
Research Opportunities for Engineering Undergraduates (ROEU) Program 2016-17
Laser ablation is a treatment method that uses light energy through a catheter inserted into a vein to induce localized heat to close the diseased blood vessels. Ultrasound (US) imaging has been used for catheter visualization and tracking. US has limitations for tracking the accurate location of the fiber tip inside small perforating veins such as angular dependency and comet tail artifacts. We propose a robust and accurate method for fiber tip tracking using combined US and Photoacoustic (PA) imaging to overcome the existing limitations.
A Structural And Functional Analysis Of Human Brain Mri With Attention Deficit Hyperactivity Disorder, Arjun A. Watane
A Structural And Functional Analysis Of Human Brain Mri With Attention Deficit Hyperactivity Disorder, Arjun A. Watane
Honors Undergraduate Theses
Attention Deficit Hyperactivity Disorder (ADHD) affects 5-10% of children worldwide. Its effects are mainly behavioral, manifesting in symptoms such as inattention, hyperactivity, and impulsivity. If not monitored and treated, ADHD may adversely affect a child's health, education, and social life. Furthermore, the neurological disorder is currently diagnosed through interviews and opinions of teachers, parents, and physicians. Because this is a subjective method of identifying ADHD, it is easily prone to error and misdiagnosis. Therefore, there is a clear need to develop an objective diagnostic method for ADHD.
The focus of this study is to explore the use of machine language …
Validation, Optimization, And Image Processing Of Spiral Cine Dense Magnetic Resonance Imaging For The Quantification Of Left And Right Ventricular Mechanics, Gregory J. Wehner
Validation, Optimization, And Image Processing Of Spiral Cine Dense Magnetic Resonance Imaging For The Quantification Of Left And Right Ventricular Mechanics, Gregory J. Wehner
Theses and Dissertations--Biomedical Engineering
Recent evidence suggests that cardiac mechanics (e.g. cardiac strains) are better measures of heart function compared to common clinical metrics like ejection fraction. However, commonly-used parameters of cardiac mechanics remain limited to just a few measurements averaged over the whole left ventricle. We hypothesized that recent advances in cardiac magnetic resonance imaging (MRI) could be extended to provide measures of cardiac mechanics throughout the left and right ventricles (LV and RV, respectively).
Displacement Encoding with Stimulated Echoes (DENSE) is a cardiac MRI technique that has been validated for measuring LV mechanics at a magnetic field strength of 1.5 T but …
The Viability Of Advantg Deterministic Method For Synthetic Radiography Generation, Andrew Albert Bingham
The Viability Of Advantg Deterministic Method For Synthetic Radiography Generation, Andrew Albert Bingham
Masters Theses
"Time sensitive and high resolution image simulations are needed for synthetic radiography generation. The standard stochastic approach requires lengthy run times with poor statistics at higher resolutions. The investigation of the viability of a deterministic approach to synthetic radiography image generation was explored. The aim was to analyze a computational time decrease over the stochastic method. ADVANTG was compared to MCNP in multiple scenarios including a Benchtop CT prototype, to simulate high resolution radiography images. By using ADVANTG deterministic code to simulate radiography images the computational time was found to decrease over 10 times compared to the MCNP stochastic approach"--Abstract, …
Development And Validation Of A Novel Resonant Energy Transfer (Fret) Biosensor To Measure Tensile Forces At The Linc Complex In Live Cells, Paul Arsenovic
Development And Validation Of A Novel Resonant Energy Transfer (Fret) Biosensor To Measure Tensile Forces At The Linc Complex In Live Cells, Paul Arsenovic
Theses and Dissertations
There is a large body of evidence supporting the theory that cell physiology largely depends on the mechanical properties of its surroundings or micro-environment. More recently studies have shown that changes to intra-cellular mechanical properties can also have a meaningful impact on cell function and in some cases lead to the progression of ailments or disease. For example, small changes to the protein sequence of a structural nuclear envelope protein called lamin-A is known to cause a variety of neurological and musculoskeletal diseases referred to as laminopathies. Currently, there is little incite into how these mutations lead to disease progression …
Pet Imaging Of Early Therapeutic Response In Solid Tumors, Stephanie J. Blocker
Pet Imaging Of Early Therapeutic Response In Solid Tumors, Stephanie J. Blocker
Wayne State University Dissertations
An important pillar of precision medicine for oncology is the ability to identify patients who respond to treatment early into their therapy. Positron emission tomography (PET) allows physicians and researchers to measure changes in tumor behavior prior to noticeable differences in morphology.
Objective: Determine the utility of multiple tracers for PET in assessing early changes in tumor activity that result from treatment.
Methods: Two tracers for PET were studied. 64Cu-labeled liposomes were used to assess changes in liposome delivery two solid colon tumors early into treatment with bevacizumab (Bev). 18F-FMAU thymidine analog (1-(2'-deoxy-2'-fluoro-beta-D-arabinofuranosyl)thymine), was utilized to detect early response to …
Computational Ultrasound Elastography: A Feasibility Study, Yu Wang
Computational Ultrasound Elastography: A Feasibility Study, Yu Wang
Dissertations, Master's Theses and Master's Reports
Ultrasound Elastography (UE) is an emerging set of imaging modalities used to assess the biomechanical properties of soft tissues. UE has been applied to numerous clinical applications. Particularly, results from clinical trials of UE in breast lesion differentiation and staging liver fibrosis indicated that there was a lack of confidence in UE measurements or image interpretation. Confidence on UE measurements interpretation is critically important for improving the clinical utility of UE. The primary objective of my thesis is to develop a computational simulation platform based on open-source software packages including Field II, VTK, FEBio and Tetgen. The proposed virtual simulation …