Open Access. Powered by Scholars. Published by Universities.®
Bioimaging and Biomedical Optics Commons™
Open Access. Powered by Scholars. Published by Universities.®
- Discipline
-
- Medicine and Health Sciences (30)
- Medical Specialties (15)
- Analytical, Diagnostic and Therapeutic Techniques and Equipment (13)
- Surgery (9)
- Diseases (7)
-
- Neoplasms (7)
- Medical Sciences (5)
- Radiology (5)
- Diagnosis (4)
- Medical Biotechnology (3)
- Surgical Procedures, Operative (3)
- Neurology (2)
- Oncology (2)
- Biomedical Devices and Instrumentation (1)
- Medical Cell Biology (1)
- Medical Physiology (1)
- Optics (1)
- Physical Sciences and Mathematics (1)
- Physics (1)
- Public Health (1)
- Women's Health (1)
- Keyword
-
- Imaging systems (13)
- Tissues (11)
- Spectroscopy (9)
- Tissue optics (9)
- Tomography (9)
-
- Medical and biological imaging (8)
- Biomedical optics (7)
- Cancer (7)
- Humans (7)
- Luminescence (6)
- Surgery (6)
- Breast (5)
- Female (5)
- Light propagation in tissues (5)
- Medical optics instrumentation (5)
- Methods (5)
- Tumors (5)
- Clinical applications (4)
- Diagnosis (4)
- Fluorescence (4)
- Image reconstruction techniques (4)
- Instrumentation (4)
- Magnetic resonance imaging (4)
- Medicine (4)
- Scattering (4)
- Absorption (3)
- Breast neoplasms (3)
- Computer-assisted (3)
- Equipment design (3)
- Equipment failure analysis (3)
Articles 31 - 60 of 63
Full-Text Articles in Bioimaging and Biomedical Optics
Review Of Biomedical Čerenkov Luminescence Imaging Applications, Kaveh Tanha, Ali Mahmoud Pashazadeh, Brian W. Pogue
Review Of Biomedical Čerenkov Luminescence Imaging Applications, Kaveh Tanha, Ali Mahmoud Pashazadeh, Brian W. Pogue
Dartmouth Scholarship
Čerenkov radiation is a fascinating optical signal, which has been exploited for unique diagnostic biological sensing and imaging, with significantly expanded use just in the last half decade. Čerenkov Luminescence Imaging (CLI) has desirable capabilities for niche applications, using specially designed measurement systems that report on radiation distributions, radiotracer and nanoparticle concentrations, and are directly applied to procedures such as medicine assessment, endoscopy, surgery, quality assurance and dosimetry. When compared to the other imaging tools such as PET and SPECT, CLI can have the key advantage of lower cost, higher throughput and lower imaging time. CLI can also provide imaging …
Next-Generation Raman Tomography Instrument For Non-Invasive In Vivo Bone Imaging, Jennifer-Lynn H. Demers, Francis W. L. Esmonde-White, Karen A. Esmonde-White, Michael D. Morris, Brian Pogue
Next-Generation Raman Tomography Instrument For Non-Invasive In Vivo Bone Imaging, Jennifer-Lynn H. Demers, Francis W. L. Esmonde-White, Karen A. Esmonde-White, Michael D. Morris, Brian Pogue
Dartmouth Scholarship
Combining diffuse optical tomography methods with Raman spectroscopy of tissue provides the ability for in vivo measurements of chemical and molecular characteristics, which have the potential for being useful in diagnostic imaging. In this study a system for Raman tomography was developed and tested. A third generation microCT coupled system was developed to combine 10 detection fibers and 5 excitation fibers with laser line filtering and a Cytop reference signal. Phantom measurements of hydroxyapatite concentrations from 50 to 300 mg/ml had a linear response. Fiber placement and experiment design was optimized using cadaver animals with live animal measurements acquired to …
Quantitative Spatial Frequency Fluorescence Imaging In The Sub-Diffusive Domain For Image-Guided Glioma Resection, Mira Sibai, Israel Veilleux, Jonathan T. Elliott, Frederic Leblond, Brian Wilson
Quantitative Spatial Frequency Fluorescence Imaging In The Sub-Diffusive Domain For Image-Guided Glioma Resection, Mira Sibai, Israel Veilleux, Jonathan T. Elliott, Frederic Leblond, Brian Wilson
Dartmouth Scholarship
Intraoperative 5- aminolevulinic acid induced-Protoporphyrin IX (PpIX) fluorescence guidance enables maximum safe resection of glioblastomas by providing surgeons with real-time tumor optical contrast. However, visual assessment of PpIX fluorescence is subjective and limited by the distorting effects of light attenuation and tissue autofluorescence. We have previously shown that non-invasive point measurements of absolute PpIX concentration identifies residual tumor that is otherwise non-detectable. Here, we extend this approach to wide-field quantitative fluorescence imaging by implementing spatial frequency domain imaging to recover tissue optical properties across the field-of-view in phantoms and ex vivo tissue.
Pixel-Based Absorption Correction For Dual-Tracer Fluorescence Imaging Of Receptor Binding Potential, Stephen C. Kanick, Kenneth M. Tichauer, Jason Gunn, Kimberley S. Samkoe, Brian W. Pogue
Pixel-Based Absorption Correction For Dual-Tracer Fluorescence Imaging Of Receptor Binding Potential, Stephen C. Kanick, Kenneth M. Tichauer, Jason Gunn, Kimberley S. Samkoe, Brian W. Pogue
Dartmouth Scholarship
Ratiometric approaches to quantifying molecular concentrations have been used for decades in microscopy, but have rarely been exploited in vivo until recently. One dual-tracer approach can utilize an untargeted reference tracer to account for non-specific uptake of a receptor-targeted tracer, and ultimately estimate receptor binding potential quantitatively. However, interpretation of the relative dynamic distribution kinetics is confounded by differences in local tissue absorption at the wavelengths used for each tracer. This study simulated the influence of absorption on fluorescence emission intensity and depth sensitivity at typical near-infrared fluorophore wavelength bands near 700 and 800 nm in mouse skin in order …
Sub-Diffusive Scattering Parameter Maps Recovered Using Wide-Field High-Frequency Structured Light Imaging, Stephen C. Kanick, David M. Mcclatchy, Venkataramanan Krishnaswamy, Jonathan T. Elliott, Keith D. Paulsen, Brian W. Pogue
Sub-Diffusive Scattering Parameter Maps Recovered Using Wide-Field High-Frequency Structured Light Imaging, Stephen C. Kanick, David M. Mcclatchy, Venkataramanan Krishnaswamy, Jonathan T. Elliott, Keith D. Paulsen, Brian W. Pogue
Dartmouth Scholarship
This study investigates the hypothesis that structured light reflectance imaging with high spatial frequency patterns (fx) can be used to quantitatively map the anisotropic scattering phase function distribution (P(θs)) in turbid media. Monte Carlo simulations were used in part to establish a semi-empirical model of demodulated reflectance (Rd) in terms of dimensionless scattering (μ′sf−1x) and γ, a metric of the first two moments of the P(θs) distribution. Experiments completed in tissue-simulating phantoms showed that simultaneous analysis of Rd spectra sampled at multiple f …
Sensitivity Of Mri-Guided Near-Infrared Spectroscopy Clinical Breast Exam Data And Its Impact On Diagnostic Performance, Michael A. Mastanduno, Junqing Xu, Fadi El-Ghussein, Shudong Jiang, Hong Yin, Yan Zhao, Kelly E. Michaelson, Ke Wang, Fang Ren, Brian W. Pogue, Keith D. Paulsen
Sensitivity Of Mri-Guided Near-Infrared Spectroscopy Clinical Breast Exam Data And Its Impact On Diagnostic Performance, Michael A. Mastanduno, Junqing Xu, Fadi El-Ghussein, Shudong Jiang, Hong Yin, Yan Zhao, Kelly E. Michaelson, Ke Wang, Fang Ren, Brian W. Pogue, Keith D. Paulsen
Dartmouth Scholarship
In this study, data from breast MRI-guided near infrared spectroscopy (NIRS) exams delivered to 44 patients scheduled for surgical resection (ending in 16 benign and 28 malignant diagnoses) were analyzed using a spatial sensitivity metric to quantify the adequacy of the optical measurements for interrogating the tumor region of interest, as derived from the concurrent MRI scan. Along with positional sensitivity, the incorporation of spectral priors and the selection of an appropriate regularization parameter in the image reconstruction were considered, and found to influence the diagnostic accuracy of the recovered images. Once optimized, the MRI/NIRS data was able to differentiate …
Extraction Of Intrinsic Fluorescence From Single Fiber Fluorescence Measurements On A Turbid Medium: Experimental Validation, U. A. Gamm, C. L. Hoy, F. Van Leeuwen - Van Zaane, H. J. C. M. Sterenborg, S. C. Kanick, D J. Robinson, A. Amelink
Extraction Of Intrinsic Fluorescence From Single Fiber Fluorescence Measurements On A Turbid Medium: Experimental Validation, U. A. Gamm, C. L. Hoy, F. Van Leeuwen - Van Zaane, H. J. C. M. Sterenborg, S. C. Kanick, D J. Robinson, A. Amelink
Dartmouth Scholarship
Abstract
The detailed mechanisms associated with the influence of scattering and absorption properties on the fluorescence intensity sampled by a single optical fiber have recently been elucidated based on Monte Carlo simulated data. Here we develop an experimental single fiber fluorescence (SFF) spectroscopy setup and validate the Monte Carlo data and semi-empirical model equation that describes the SFF signal as a function of scattering. We present a calibration procedure that corrects the SFF signal for all system-related, wavelength dependent transmission efficiencies to yield an absolute value of intrinsic fluorescence. The validity of the Monte Carlo data and semi-empirical model is …
Advances In Optics For Biotechnology, Medicine And Surgery, Maryann Fitzmaurice, Brian W. Pogue, Guillermo J. Tearney, James W. Tunnell
Advances In Optics For Biotechnology, Medicine And Surgery, Maryann Fitzmaurice, Brian W. Pogue, Guillermo J. Tearney, James W. Tunnell
Dartmouth Scholarship
The guest editors introduce a Biomedical Optics Express feature issue that includes contributions from participants at the 2013 conference on Advances in Optics for Biotechnology, Medicine and Surgery XIII.
Spectral Discrimination Of Breast Pathologies In Situ Using Spatial Frequency Domain Imaging, Ashley M. Laughney, Venkataramanan Krishnaswamy, Elizabeth J. Rizzo, Mary C. Schwab, Richard J. Barth, David J. Cuccia, Bruce J. Tromberg, Keith D. Paulsen, Brian W. Pogue, Wendy A. Wells
Spectral Discrimination Of Breast Pathologies In Situ Using Spatial Frequency Domain Imaging, Ashley M. Laughney, Venkataramanan Krishnaswamy, Elizabeth J. Rizzo, Mary C. Schwab, Richard J. Barth, David J. Cuccia, Bruce J. Tromberg, Keith D. Paulsen, Brian W. Pogue, Wendy A. Wells
Dartmouth Scholarship
Introduction: Nationally, 25% to 50% of patients undergoing lumpectomy for local management of breast cancer require a secondary excision because of the persistence of residual tumor. Intraoperative assessment of specimen margins by frozen-section analysis is not widely adopted in breast-conserving surgery. Here, a new approach to wide-field optical imaging of breast pathology in situ was tested to determine whether the system could accurately discriminate cancer from benign tissues before routine pathological processing.
Dynamic Dual-Tracer Mri-Guided Fluorescence Tomography To Quantify Receptor Density In Vivo, Scott C. Davis, Kimberley S. Samkoe, Kenneth M. Tichauer, Kristian J. Sexton, Jason R. Gunn, Sophie J. Deharvengt, Tayyaba Hasan, Brian W. Pogue
Dynamic Dual-Tracer Mri-Guided Fluorescence Tomography To Quantify Receptor Density In Vivo, Scott C. Davis, Kimberley S. Samkoe, Kenneth M. Tichauer, Kristian J. Sexton, Jason R. Gunn, Sophie J. Deharvengt, Tayyaba Hasan, Brian W. Pogue
Dartmouth Scholarship
The up-regulation of cell surface receptors has become a central focus in personalized cancer treatment; however, because of the complex nature of contrast agent pharmacokinetics in tumor tissue, methods to quantify receptor binding in vivo remain elusive. Here, we present a dual-tracer optical technique for noninvasive estimation of specific receptor binding in cancer. A multispectral MRI-coupled fluorescence molecular tomography system was used to image the uptake kinetics of two fluorescent tracers injected simultaneously, one tracer targeted to the receptor of interest and the other tracer a nontargeted reference. These dynamic tracer data were then fit to a dual-tracer compartmental model …
A Gamos Plug-In For Geant4 Based Monte Carlo Simulation Of Radiation-Induced Light Transport In Biological Media, Adam K. Glaser, Stephen C. Kanick, Rongxiao Zhang, Pedro Arce, Brian W. Pogue
A Gamos Plug-In For Geant4 Based Monte Carlo Simulation Of Radiation-Induced Light Transport In Biological Media, Adam K. Glaser, Stephen C. Kanick, Rongxiao Zhang, Pedro Arce, Brian W. Pogue
Dartmouth Scholarship
We describe a tissue optics plug-in that interfaces with the GEANT4/GAMOS Monte Carlo (MC) architecture, providing a means of simulating radiation-induced light transport in biological media for the first time. Specifically, we focus on the simulation of light transport due to the Čerenkov effect (light emission from charged particle's traveling faster than the local speed of light in a given medium), a phenomenon which requires accurate modeling of both the high energy particle and subsequent optical photon transport, a dynamic coupled process that is not well-described by any current MC framework. The results of validation simulations show excellent agreement with …
Scanning In Situ Spectroscopy Pplatform For Imaging Surgical Breast Tissue Specimens, Venkataramanan Krishnaswamy, Ashley M. Laughney, Wendy A. Wells, Keith D. Paulsen, Brian W. Pogue
Scanning In Situ Spectroscopy Pplatform For Imaging Surgical Breast Tissue Specimens, Venkataramanan Krishnaswamy, Ashley M. Laughney, Wendy A. Wells, Keith D. Paulsen, Brian W. Pogue
Dartmouth Scholarship
A non-contact localized spectroscopic imaging platform has been developed and optimized to scan 1 x 1 cm² square regions of surgically resected breast tissue specimens with ~150-micron resolution. A color corrected, image-space telecentric scanning design maintained a consistent sampling geometry and uniform spot size across the entire imaging field. Theoretical modeling in ZEMAX allowed estimation of the spot size, which is equal at both the center and extreme positions of the field with ~5% variation across the designed waveband, indicating excellent color correction. The spot sizes at the center and an extreme field position were also measured experimentally using the …
Quantitative, Spectrally-Resolved Intraoperative Fluorescence Imaging, Pablo A. Valdés, Frederic Leblond, Valerie L. Jacobs, Brian C. Wilson, Keith D. Paulsen, David W. Roberts
Quantitative, Spectrally-Resolved Intraoperative Fluorescence Imaging, Pablo A. Valdés, Frederic Leblond, Valerie L. Jacobs, Brian C. Wilson, Keith D. Paulsen, David W. Roberts
Dartmouth Scholarship
Intraoperative visual fluorescence imaging (vFI) has emerged as a promising aid to surgical guidance, but does not fully exploit the potential of the fluorescent agents that are currently available. Here, we introduce a quantitative fluorescence imaging (qFI) approach that converts spectrally-resolved data into images of absolute fluorophore concentration pixel-by-pixel across the surgical field of view (FOV). The resulting estimates are linear, accurate, and precise relative to true values, and spectral decomposition of multiple fluorophores is also achieved. Experiments with protoporphyrin IX in a glioma rodent model demonstrate in vivo quantitative and spectrally-resolved fluorescence imaging of infiltrating tumor margins for the …
A Digital X-Ray Tomosynthesis Coupled Near Infrared Spectral Tomography System For Dual-Modality Breast Imaging, Venkataramanan Krishnaswamy, Kelly E. Michaelsen, Brian W. Pogue, Steven P. Poplack, Ian Shaw, Ken Defrietas, Ken Brooks, Keith D. Paulsen
A Digital X-Ray Tomosynthesis Coupled Near Infrared Spectral Tomography System For Dual-Modality Breast Imaging, Venkataramanan Krishnaswamy, Kelly E. Michaelsen, Brian W. Pogue, Steven P. Poplack, Ian Shaw, Ken Defrietas, Ken Brooks, Keith D. Paulsen
Dartmouth Scholarship
A Near Infrared Spectral Tomography (NIRST) system has been developed and integrated into a commercial Digital Breast Tomosynthesis (DBT) scanner to allow structural and functional imaging of breast in vivo. The NIRST instrument uses an 8-wavelength continuous wave (CW) laser-based scanning source assembly and a 75-element silicon photodiode solid-state detector panel to produce dense spectral and spatial projection data from which spectrally constrained 3D tomographic images of tissue chromophores are produced. Integration of the optical imaging system into the DBT scanner allows direct co-registration of the optical and DBT images, while also facilitating the synergistic use of x-ray contrast as …
Measurement Of The Oxidation State Of Mitochondrial Cytochrome C From The Neocortex Of The Mammalian Brain, Y. Sakata, M. Abajian, M. O. Ripple, R. Springett
Measurement Of The Oxidation State Of Mitochondrial Cytochrome C From The Neocortex Of The Mammalian Brain, Y. Sakata, M. Abajian, M. O. Ripple, R. Springett
Dartmouth Scholarship
Diffuse optical remission spectra from the mammalian neocortex at visible wavelengths contain spectral features originating from the mitochondria. A new algorithm is presented, based on analytically relating the first differential of the attenuation spectrum to the first differential of the chromophore spectra, that can separate and calculate the oxidation state of cytochrome c as well as the absolute concentration and saturation of hemoglobin. The algorithm is validated in phantoms and then tested on the neocortex of the rat during an anoxic challenge. Implementation of the algorithm will provide detailed information of mitochondrial oxygenation and mitochondrial function in physiological studies of …
Quantitative Cherenkov Emission Spectroscopy For Tissue Oxygenation Assessment, Johan Axelsson, Adam K. Glaser, David J. Gladstone, Brian W. Pogue
Quantitative Cherenkov Emission Spectroscopy For Tissue Oxygenation Assessment, Johan Axelsson, Adam K. Glaser, David J. Gladstone, Brian W. Pogue
Dartmouth Scholarship
Measurements of Cherenkov emission in tissue during radiation therapy are shown to enable estimation of hemoglobin oxygen saturation non-invasively, through spectral fitting of the spontaneous emissions from the treated tissue. Tissue oxygenation plays a critical role in the efficacy of radiation therapy to kill tumor tissue. Yet in-vivo measurement of this has remained elusive in routine use because of the complexity of oxygen measurement techniques. There is a spectrally broad emission of Cherenkov light that is induced during the time of irradiation, and as this travels through tissue from the point of the radiation deposition, the tissue absorption and scatter …
Dual-Channel Imaging System For Singlet Oxygen And Photosensitizer For Pdt, Seonkyung Lee, Martin E. Isabelle, Kristin L. Gabally-Kinney, Brian W. Pogue, Steven J. Davis
Dual-Channel Imaging System For Singlet Oxygen And Photosensitizer For Pdt, Seonkyung Lee, Martin E. Isabelle, Kristin L. Gabally-Kinney, Brian W. Pogue, Steven J. Davis
Dartmouth Scholarship
A two-channel optical system has been developed to provide spatially resolved simultaneous imaging of singlet molecular oxygen (1O2) phosphorescence and photosensitizer (PS) fluorescence produced by the photodynamic process. The current imaging system uses a spectral discrimination method to differentiate the weak 1O2 phosphorescence that peaks near 1.27 μ m from PS fluorescence that also occurs in this spectral region. The detection limit of 1O2 emission was determined at a concentration of 500 nM benzoporphyrin derivative monoacid (BPD) in tissue-like phantoms, and these signals observed were proportional to the PS fluorescence. Preliminary in …
Singular Value Decomposition Metrics Show Limitations Of Detector Design In Diffuse Fluorescence Tomography, Frederic Leblond, Kenneth M. Tichauer, Brian W. Pogue
Singular Value Decomposition Metrics Show Limitations Of Detector Design In Diffuse Fluorescence Tomography, Frederic Leblond, Kenneth M. Tichauer, Brian W. Pogue
Dartmouth Scholarship
The spatial resolution and recovered contrast of images reconstructed from diffuse fluorescence tomography data are limited by the high scattering properties of light propagation in biological tissue. As a result, the image reconstruction process can be exceedingly vulnerable to inaccurate prior knowledge of tissue optical properties and stochastic noise. In light of these limitations, the optimal source-detector geometry for a fluorescence tomography system is non-trivial, requiring analytical methods to guide design. Analysis of the singular value decomposition of the matrix to be inverted for image reconstruction is one potential approach, providing key quantitative metrics, such as singular image mode spatial …
Importance Of Phase Unwrapping For The Reconstruction Of Microwave Tomographic Images, Tomasz M. Grzegorczyk, Paul M. Meaney, Soon Ik Jeon, Shireen D. Geimer, Keith D. Paulsen
Importance Of Phase Unwrapping For The Reconstruction Of Microwave Tomographic Images, Tomasz M. Grzegorczyk, Paul M. Meaney, Soon Ik Jeon, Shireen D. Geimer, Keith D. Paulsen
Dartmouth Scholarship
Microwave image reconstruction is typically based on a regularized least-square minimization of either the complex-valued field difference between recorded and modeled data or the logarithmic transformation of these field differences. Prior work has shown anecdotally that the latter outperforms the former in limited surveys of simulated and experimental phantom results. In this paper, we provide a theoretical explanation of these empirical findings by developing closed form solutions for the fie
Characterizing Accuracy Of Total Hemoglobin Recovery Using Contrast-Detail Analysis In 3d Image-Guided Near Infrared Spectroscopy With The Boundary Element Method, Hamid R. Ghadyani, Subhadra Srinivasan, Brian W. Pogue, Keith D. Paulsen
Characterizing Accuracy Of Total Hemoglobin Recovery Using Contrast-Detail Analysis In 3d Image-Guided Near Infrared Spectroscopy With The Boundary Element Method, Hamid R. Ghadyani, Subhadra Srinivasan, Brian W. Pogue, Keith D. Paulsen
Dartmouth Scholarship
The quantification of total hemoglobin concentration (HbT) obtained from multi-modality image-guided near infrared spectroscopy (IG-NIRS) was characterized using the boundary element method (BEM) for 3D image reconstruction. Multi-modality IG-NIRS systems use a priori information to guide the reconstruction process. While this has been shown to improve resolution, the effect on quantitative accuracy is unclear. Here, through systematic contrast-detail analysis, the fidelity of IG-NIRS in quantifying HbT was examined using 3D simulations. These simulations show that HbT could be recovered for medium sized (20mm in 100mm total diameter) spherical inclusions with an average error of 15%, for the physiologically …
Characterization Of An Implicitly Resistively-Loaded Monopole Antenna In Lossy Liquid Media, Colleen J. Fox, Paul M. Meaney, Fridon Shubitidze, Lincoln Potwin, Keith D. Paulsen
Characterization Of An Implicitly Resistively-Loaded Monopole Antenna In Lossy Liquid Media, Colleen J. Fox, Paul M. Meaney, Fridon Shubitidze, Lincoln Potwin, Keith D. Paulsen
Dartmouth Scholarship
Abstract
Microwave tomographic imaging of the breast for cancer detection is a topic of considerable interest because of the potential to exploit the apparent high-dielectric property contrast between normal and malignant tissue. An important component in the realization of an imaging system is the antenna array to be used for signal transmission/detection. The monopole antenna has proven to be useful in our implementation because it can be easily and accurately modeled and can be positioned in close proximity to the imaging target with high-element density when configured in an imaging array. Its frequency response is broadened considerably when radiating in …
Automatic Exposure Control And Estimation Of Effective System Noise In Diffuse Fluorescence Tomography, Dax L. Kepshire, Hamid Dehghani, Frederic Leblond, Brian W. Pogue
Automatic Exposure Control And Estimation Of Effective System Noise In Diffuse Fluorescence Tomography, Dax L. Kepshire, Hamid Dehghani, Frederic Leblond, Brian W. Pogue
Dartmouth Scholarship
A diffuse fluorescence tomography system, based upon time-correlated single photon counting, is presented with an automated algorithm to allow dynamic range variation through exposure control. This automated exposure control allows the upper and lower detection levels of fluorophore to be extended by an order of magnitude beyond the previously published performance and benefits in a slight decrease in system effective noise. The effective noise level is used as a metric to characterize the system performance, integrating both model-mismatch and calibration bias errors into a single parameter. This effective error is near 7% of the reconstructed fluorescent yield value, when imaging …
Statistical Hypothesis Testing For Postreconstructed And Postregistered Medical Images, Eugene Demidenko
Statistical Hypothesis Testing For Postreconstructed And Postregistered Medical Images, Eugene Demidenko
Dartmouth Scholarship
Postreconstructed and postregistered medical images are typically treated as the raw data, implicitly assuming that those operations are error free. We question this assumption and explore how the precision of reconstruction and affine registration can be assessed by the image covariance matrix and confidence interval, called the confidence eigenimage, using a statistical model-based approach. Various hypotheses may be tested after image reconstruction and registration using classical statistical hypothesis testing vehicles: Is there a statistically significant difference between images? Does the intensity at a specific location or area of interest belong to the “normal” range? Is there a tumor? Does the …
Video-Rate Near Infrared Tomography To Image Pulsatile Absorption Properties In Thick Tissue, Zhiqiu Li, Venkataramanan Krishnaswamy, Scott C. Davis, Subhadra Srinivasan, Keith D. Paulsen, Brian W. Pogue
Video-Rate Near Infrared Tomography To Image Pulsatile Absorption Properties In Thick Tissue, Zhiqiu Li, Venkataramanan Krishnaswamy, Scott C. Davis, Subhadra Srinivasan, Keith D. Paulsen, Brian W. Pogue
Dartmouth Scholarship
A high frame-rate near-infrared (NIR) tomography system was created to allow transmission imaging of thick tissues with spectral encoding for parallel source implementation. The design was created to maximize tissue penetration through up to 10 cm of tissue, allowing eventual use in human imaging. Eight temperature-controlled laser diodes (LD) are used in parallel with 1.5 nm shifts in their lasing wavelengths. Simultaneous detection is achieved with eight high-resolution, CCD-based spectrometers that were synchronized to detect the intensities and decode their source locations from the spectrum. Static and dynamic imaging is demonstrated through a 64 mm tissue-equivalent phantom, with acquisition rates …
In Vitro Ovarian Tumor Growth And Treatment Response Dynamics Visualized With Time-Lapse Oct Imaging, Conor L. Evans, Imran Rizvi, Tayyaba Hasan, Johannes F. De Boer
In Vitro Ovarian Tumor Growth And Treatment Response Dynamics Visualized With Time-Lapse Oct Imaging, Conor L. Evans, Imran Rizvi, Tayyaba Hasan, Johannes F. De Boer
Dartmouth Scholarship
In vitro three-dimensional models for metastatic ovarian cancer have been useful for recapitulating the human disease. These spheroidal tumor cultures, however, can grow in excess of 1 mm in diameter, which are difficult to visualize without suitable imaging technology.Optical coherence tomography (OCT) is an ideal live imaging method for non-perturbatively visualizing these complex systems. OCT enabled detailed observations of the model at both nodular and cellular levels, revealing growth dynamics not previously observed. The development of a time-lapse OCT system, capable of automated, multidimensional acquisition, further provided insights into the growth and chemotherapeutic response of ovarian cancer.
Methodology Development For Three-Dimensional Mr-Guided Near Infrared Spectroscopy Of Breast Tumors, Colin M. Carpenter, Subhadra Srinivasan, Brian W. Pogue, Keith D. Paulsen
Methodology Development For Three-Dimensional Mr-Guided Near Infrared Spectroscopy Of Breast Tumors, Colin M. Carpenter, Subhadra Srinivasan, Brian W. Pogue, Keith D. Paulsen
Dartmouth Scholarship
Combined Magnetic Resonance (MR) and Near Infrared Spectroscopy (NIRS) has been proposed as a unique method to quantify hemodynamics, water content, and cellular size and packing density of breast tumors, as these tissue constituents can be quantified with increased resolution and overlaid on the structural features identified by the MR. However, the choices in how to reconstruct and visualize this information can have a dramatic impact on the feasibility of implementing this modality in the clinic. This is especially true in 3 dimensions, as there is often limited optical sampling of the breast tissue, and methods need to accurately reflect …
Image-Guided Raman Spectroscopic Recovery Of Canine Cortical Bone Contrast In Situ, Subhadra Srinivasan, Matthew Schulmerich, Jacqueline H. Cole, Kathryn Dooley, Jaclynn M. Kreider, Brian W. Pogue
Image-Guided Raman Spectroscopic Recovery Of Canine Cortical Bone Contrast In Situ, Subhadra Srinivasan, Matthew Schulmerich, Jacqueline H. Cole, Kathryn Dooley, Jaclynn M. Kreider, Brian W. Pogue
Dartmouth Scholarship
Raman scattering provides valuable biochemical and molecular markers for studying bone tissue composition with use in predicting fracture risk in osteoporosis. Raman tomography can image through a few centimeters of tissue but is limited by low spatial resolution. X-ray computed tomography (CT) imaging can provide high-resolution image-guidance of the Raman spectroscopic characterization, which enhances the quantitative recovery of the Raman signals, and this technique provides additional information to standard imaging methods. This hypothesis was tested in data measured from Teflon tissue phantoms and from a canine limb. Image-guided Raman spectroscopy (IG-RS) of the canine limb using CT images of the …
Fluorescence Tomography Characterization For Sub-Surface Imaging With Protoporphyrin Ix, Dax Kepshire, Scott C. Davis, Hamid Dehghani, Keith D. Paulsen, Brian W. Pogue
Fluorescence Tomography Characterization For Sub-Surface Imaging With Protoporphyrin Ix, Dax Kepshire, Scott C. Davis, Hamid Dehghani, Keith D. Paulsen, Brian W. Pogue
Dartmouth Scholarship
Optical imaging of fluorescent objects embedded in a tissue simulating medium was characterized using non-contact based approaches to fluorescence remittance imaging (FRI) and sub-surface fluorescence diffuse optical tomography (FDOT). Using Protoporphyrin IX as a fluorescent agent, experiments were performed on tissue phantoms comprised of typical in-vivo tumor to normal tissue contrast ratios, ranging from 3.5:1 up to 10:1. It was found that tomographic imaging was able to recover interior inclusions with high contrast relative to the background; however, simple planar fluorescence imaging provided a superior contrast to noise ratio. Overall, FRI performed optimally when the object was located on or …
Image-Guided Diffuse Optical Fluorescence Tomography Implemented With Laplacian-Type Regularization, Scott C. Davis, Hamid Dehghani, Jia Wang, Shudong Jiang, Brian W. Pogue, Keith D. Paulsen
Image-Guided Diffuse Optical Fluorescence Tomography Implemented With Laplacian-Type Regularization, Scott C. Davis, Hamid Dehghani, Jia Wang, Shudong Jiang, Brian W. Pogue, Keith D. Paulsen
Dartmouth Scholarship
A promising method to incorporate tissue structural information into the reconstruction of diffusion-based fluorescence imaging is introduced. The method regularizes the inversion problem with a Laplacian-type matrix, which inherently smoothes pre-defined tissue, but allows discontinuities between adjacent regions. The technique is most appropriately used when fluorescence tomography is combined with structural imaging systems. Phantom and simulation studies were used to illustrate significant improvements in quantitative imaging and linearity of response with the new algorithm. Images of an inclusion containing the fluorophore Lutetium Texaphyrin (Lutex) embedded in a cylindrical phantom are more accurate than in situations where no structural information is …
Critical Computational Aspects Of Near Infrared Circular Tomographic Imaging: Analysis Of Measurement Number, Mesh Resolution And Reconstruction Basis, Phaneendra K. Yalavarthy, Hamid Dehghani, Brian W. Pogue, Keit D. Paulsen
Critical Computational Aspects Of Near Infrared Circular Tomographic Imaging: Analysis Of Measurement Number, Mesh Resolution And Reconstruction Basis, Phaneendra K. Yalavarthy, Hamid Dehghani, Brian W. Pogue, Keit D. Paulsen
Dartmouth Scholarship
The image resolution and contrast in Near-Infrared (NIR) tomographic image reconstruction are affected by parameters such as the number of boundary measurements, the mesh resolution in the forward calculation and the reconstruction basis. Increasing the number of measurements tends to make the sensitivity of the domain more uniform reducing the hypersensitivity at the boundary. Using singular-value decomposition (SVD) and reconstructed images, it is shown that the numbers of 16 or 24 fibers are sufficient for imaging the 2D circular domain for the case of 1% noise in the data. The number of useful singular values increases as the logarithm of …