Improved Sensitivity To Fluorescence For Cancer Detection In Wide-Field Image-Guided Neurosurgery, Michael Jermyn, Yoann Gosselin, Pablo A. Valdes, Mira Sibai, Kolbein Kolste Nov 2015

Improved Sensitivity To Fluorescence For Cancer Detection In Wide-Field Image-Guided Neurosurgery, Michael Jermyn, Yoann Gosselin, Pablo A. Valdes, Mira Sibai, Kolbein Kolste

Dartmouth Scholarship

In glioma surgery, Protoporphyrin IX (PpIX) fluorescence may identify residual tumor that could be resected while minimizing damage to normal brain. We demonstrate that improved sensitivity for wide-field spectroscopic fluorescence imaging is achieved with minimal disruption to the neurosurgical workflow using an electron-multiplying charge-coupled device (EMCCD) relative to a state-of-the-art CMOS system. In phantom experiments the EMCCD system can detect at least two orders-of-magnitude lower PpIX. Ex vivo tissue imaging on a rat glioma model demonstrates improved fluorescence contrast compared with neurosurgical fluorescence microscope technology, and the fluorescence detection is confirmed with measurements from a clinically-validated spectroscopic probe. Greater PpIX …


Calibration And Optimization Of 3d Digital Breast Tomosynthesis Guided Near Infrared Spectral Tomography, Kelly E. Michaelsen, Venkataramanan Krishnaswamy, Linxi Shi, Srinivasan Vedantham, Steven Poplack, Andrew Karellas, Brian Pogue, Keith Paulsen Nov 2015

Calibration And Optimization Of 3d Digital Breast Tomosynthesis Guided Near Infrared Spectral Tomography, Kelly E. Michaelsen, Venkataramanan Krishnaswamy, Linxi Shi, Srinivasan Vedantham, Steven Poplack, Andrew Karellas, Brian Pogue, Keith Paulsen

Dartmouth Scholarship

Calibration of a three-dimensional multimodal digital breast tomosynthesis (DBT) x-ray and non-fiber based near infrared spectral tomography (NIRST) system is challenging but essential for clinical studies. Phantom imaging results yielded linear contrast recovery of total hemoglobin (HbT) concentration for cylindrical inclusions of 15 mm, 10 mm and 7 mm with a 3.5% decrease in the HbT estimate for each 1 cm increase in inclusion depth. A clinical exam of a patient's breast containing both benign and malignant lesions was successfully imaged, with greater HbT was found in the malignancy relative to the benign abnormality and fibroglandular regions (11 μM vs. …


Initial Validation Of A Novel Method Of Presurgical Language Localization Through Functional Connectivity (Fcmri), Stephanie M. Noble, Dustin Scheinost, Susan Y. Bookheimer, Patricia Walshaw, R Todd Constable, Christopher F. Benjamin Sep 2015

Initial Validation Of A Novel Method Of Presurgical Language Localization Through Functional Connectivity (Fcmri), Stephanie M. Noble, Dustin Scheinost, Susan Y. Bookheimer, Patricia Walshaw, R Todd Constable, Christopher F. Benjamin

Yale Day of Data

OBJECTIVE: Neurosurgery is potentially curative in chronic epilepsy but can only be offered to patients if the surgical risk to language is known. Clinical functional magnetic resonance imaging (fMRI) is an ideal, noninvasive method for localizing language cortex yet remains to be validated for this purpose. We have recently presented a novel method for localizing language cortex. Here we present a preliminary evaluation of this method’s validity. We hypothesized language regions identified using this novel method would demonstrate stronger functional connectivity than randomly generated set of proximal networks. METHOD: fMRI data were collected from sixteen temporal lobe patients …


Review Of Fluorescence Guided Surgery Visualization And Overlay Techniques, Jonathan T. Elliott, Alisha V. Dsouza, Scott C. Davis, Jonathan D. Olson, Keith Paulsen, David Roberts, Brian Pogue Sep 2015

Review Of Fluorescence Guided Surgery Visualization And Overlay Techniques, Jonathan T. Elliott, Alisha V. Dsouza, Scott C. Davis, Jonathan D. Olson, Keith Paulsen, David Roberts, Brian Pogue

Dartmouth Scholarship

In fluorescence guided surgery, data visualization represents a critical step between signal capture and display needed for clinical decisions informed by that signal. The diversity of methods for displaying surgical images are reviewed, and a particular focus is placed on electronically detected and visualized signals, as required for near-infrared or low concentration tracers. Factors driving the choices such as human perception, the need for rapid decision making in a surgical environment, and biases induced by display choices are outlined. Five practical suggestions are outlined for optimal display orientation, color map, transparency/alpha function, dynamic range compression, and color perception check.


Changes In Vessel Properties During Early Progression Of Murine Abdominal Aortic Aneurysms From In Vivo Ultrasound, Luis R. Avila Murati, Evan H. Phillips, Craig J. Goergen Aug 2015

Changes In Vessel Properties During Early Progression Of Murine Abdominal Aortic Aneurysms From In Vivo Ultrasound, Luis R. Avila Murati, Evan H. Phillips, Craig J. Goergen

The Summer Undergraduate Research Fellowship (SURF) Symposium

Abdominal aortic aneurysms (AAA) are a common and frequently fatal disease characterized by the weakening and dilation of the aorta. The larger the aneurysm, the higher the chances are of rupturing and life-threatening hemorrhage. The aim of this study is to apply the angiotensin II (AngII) model of AAAs in male apolipoprotein-E-deficient mice (apoE-/- C57Bl/6J), in order to analyze, quantify, and understand the pathologies and characteristics associated with early AAA development. To date, many studies focusing on the evaluation of AAA characteristics have been performed ex vivo. Therefore, we focused on in vivo assessment, through the use of …


Review Of Biomedical Čerenkov Luminescence Imaging Applications, Kaveh Tanha, Ali Mahmoud Pashazadeh, Brian W. Pogue Aug 2015

Review Of Biomedical Čerenkov Luminescence Imaging Applications, Kaveh Tanha, Ali Mahmoud Pashazadeh, Brian W. Pogue

Dartmouth Scholarship

Čerenkov radiation is a fascinating optical signal, which has been exploited for unique diagnostic biological sensing and imaging, with significantly expanded use just in the last half decade. Čerenkov Luminescence Imaging (CLI) has desirable capabilities for niche applications, using specially designed measurement systems that report on radiation distributions, radiotracer and nanoparticle concentrations, and are directly applied to procedures such as medicine assessment, endoscopy, surgery, quality assurance and dosimetry. When compared to the other imaging tools such as PET and SPECT, CLI can have the key advantage of lower cost, higher throughput and lower imaging time. CLI can also provide imaging …


Mobile Cloud Computing Based Non Rigid Registration For Image Guided Surgery, Arun Brahmavar Vishwanatha Aug 2015

Mobile Cloud Computing Based Non Rigid Registration For Image Guided Surgery, Arun Brahmavar Vishwanatha

Computer Science Theses & Dissertations

In this thesis we present the design and implementation of a Mobile Cloud computing platform for non-rigid registration required in Image Guided Surgery (MCIGS). MCIGS contributes in flexible, portable and accurate alignment of pre-operative brain data with intra-operative MRI, for image guided diagnosis and therapy and endoscopic skull base surgery. Improved precision of image guided therapy and specifically neurosurgery procedures is known to result in the improved prognosis for brain tumor patients. MCI GS system is tested with Physics Based Non-Rigid Registration method form ITK. Our preliminary results for brain images indicate that the proposed system over Wi-Fi can be …


Characterization Of Low Density Intracranial Lesions Using Dual-Energy Computed To Mography, Jessica L. Nute May 2015

Characterization Of Low Density Intracranial Lesions Using Dual-Energy Computed To Mography, Jessica L. Nute

Dissertations and Theses (Open Access)

Calcific and hemorrhagic foci of susceptibility are frequently encountered on routine brain MR studies. Both etiologies cause variations in local magnetic field strength, leading to dark regions on the MR images that cannot be classified. Single-energy CT (SECT) can be used to identify lesions with attenuation over 100 HU as calcific, however lesions with lower attenuation cannot be reliably identified. While calcific lesions are unlikely to cause harm, hemorrhagic lesions carry a risk of subsequent intracranial bleeding; as such, identification of hemorrhage is vital in preventing the inappropriate use of anticoagulant medications in patients with hemorrhagic lesions.

Given there currently …


Next-Generation Raman Tomography Instrument For Non-Invasive In Vivo Bone Imaging, Jennifer-Lynn H. Demers, Francis W. L. Esmonde-White, Karen A. Esmonde-White, Michael D. Morris, Brian Pogue Feb 2015

Next-Generation Raman Tomography Instrument For Non-Invasive In Vivo Bone Imaging, Jennifer-Lynn H. Demers, Francis W. L. Esmonde-White, Karen A. Esmonde-White, Michael D. Morris, Brian Pogue

Dartmouth Scholarship

Combining diffuse optical tomography methods with Raman spectroscopy of tissue provides the ability for in vivo measurements of chemical and molecular characteristics, which have the potential for being useful in diagnostic imaging. In this study a system for Raman tomography was developed and tested. A third generation microCT coupled system was developed to combine 10 detection fibers and 5 excitation fibers with laser line filtering and a Cytop reference signal. Phantom measurements of hydroxyapatite concentrations from 50 to 300 mg/ml had a linear response. Fiber placement and experiment design was optimized using cadaver animals with live animal measurements acquired to …


Noncontact Diffuse Correlation Tomography Of Breast Tumor, Lian He Jan 2015

Noncontact Diffuse Correlation Tomography Of Breast Tumor, Lian He

Theses and Dissertations--Biomedical Engineering

Since aggressive cancers are frequently hypermetabolic with angiogenic vessels, quantification of blood flow (BF) can be vital for cancer diagnosis. Our laboratory has developed a noncontact diffuse correlation tomography (ncDCT) system for 3-D imaging of BF distribution in deep tissues (up to centimeters). The ncDCT system employs two sets of optical lenses to project source and detector fibers respectively onto the tissue surface, and applies finite element framework to model light transportation in complex tissue geometries. This thesis reports our first step to adapt the ncDCT system for 3-D imaging of BF contrasts in human breast tumors. A commercial 3-D …


Computer Aided Detection Of Oral Lesions On Ct Images, Shaikat Mahmood Galib Jan 2015

Computer Aided Detection Of Oral Lesions On Ct Images, Shaikat Mahmood Galib

Masters Theses

"Oral lesions are important findings on computed tomography images. They are difficult to detect on CT images because of low contrast, arbitrary orientation of objects, complicated topology and lack of clear lines indicating lesions. In this thesis, a fully automatic method to detect oral lesions from dental CT images is proposed to identify (1) Closed boundary lesions and (2) Bone deformation lesions. Two algorithms were developed to recognize these two types of lesions, which cover most of the lesion types that can be found on CT images. The results were validated using a dataset of 52 patients. Using non training …


Diffuse Optical Measurements Of Head And Neck Tumor Hemodynamics For Early Prediction Of Chemo-Radiation Therapy Outcomes, Lixin Dong Jan 2015

Diffuse Optical Measurements Of Head And Neck Tumor Hemodynamics For Early Prediction Of Chemo-Radiation Therapy Outcomes, Lixin Dong

Theses and Dissertations--Biomedical Engineering

Chemo-radiation therapy is a principal modality for the treatment of head and neck cancers, and its efficacy depends on the interaction of tumor oxygen with free radicals. In this study, we adopted a novel hybrid diffuse optical instrument combining a commercial frequency-domain tissue oximeter (Imagent) and a custom-made diffuse correlation spectroscopy (DCS) flowmeter, which allowed for simultaneous measurements of tumor blood flow and blood oxygenation. Using this hybrid instrument we continually measured tumor hemodynamic responses to chemo-radiation therapy over the treatment period of 7 weeks. We also explored monitoring dynamic tumor hemodynamic changes during radiation delivery. Blood flow data analysis …


Quantitative Spatial Frequency Fluorescence Imaging In The Sub-Diffusive Domain For Image-Guided Glioma Resection, Mira Sibai, Israel Veilleux, Jonathan T. Elliott, Frederic Leblond, Brian Wilson Jan 2015

Quantitative Spatial Frequency Fluorescence Imaging In The Sub-Diffusive Domain For Image-Guided Glioma Resection, Mira Sibai, Israel Veilleux, Jonathan T. Elliott, Frederic Leblond, Brian Wilson

Dartmouth Scholarship

Intraoperative 5- aminolevulinic acid induced-Protoporphyrin IX (PpIX) fluorescence guidance enables maximum safe resection of glioblastomas by providing surgeons with real-time tumor optical contrast. However, visual assessment of PpIX fluorescence is subjective and limited by the distorting effects of light attenuation and tissue autofluorescence. We have previously shown that non-invasive point measurements of absolute PpIX concentration identifies residual tumor that is otherwise non-detectable. Here, we extend this approach to wide-field quantitative fluorescence imaging by implementing spatial frequency domain imaging to recover tissue optical properties across the field-of-view in phantoms and ex vivo tissue.


Multi-Surface Simplex Spine Segmentation For Spine Surgery Simulation And Planning, Rabia Haq Jan 2015

Multi-Surface Simplex Spine Segmentation For Spine Surgery Simulation And Planning, Rabia Haq

Computational Modeling & Simulation Engineering Theses & Dissertations

This research proposes to develop a knowledge-based multi-surface simplex deformable model for segmentation of healthy as well as pathological lumbar spine data. It aims to provide a more accurate and robust segmentation scheme for identification of intervertebral disc pathologies to assist with spine surgery planning. A robust technique that combines multi-surface and shape statistics-aware variants of the deformable simplex model is presented. Statistical shape variation within the dataset has been captured by application of principal component analysis and incorporated during the segmentation process to refine results. In the case where shape statistics hinder detection of the pathological region, user-assistance is …


Femtosecond Laser Beam Propagation Through Corneal Tissue: Evaluation Of Therapeutic Laser-Stimulated Second And Third-Harmonic Generation, William R. Calhoun Iii Jan 2015

Femtosecond Laser Beam Propagation Through Corneal Tissue: Evaluation Of Therapeutic Laser-Stimulated Second And Third-Harmonic Generation, William R. Calhoun Iii

Theses and Dissertations

One of the most recent advancements in laser technology is the development of ultrashort pulsed femtosecond lasers (FSLs). FSLs are improving many fields due to their unique extreme precision, low energy and ablation characteristics. In the area of laser medicine, ophthalmic surgeries have seen very promising developments. Some of the most commonly performed surgical operations in the world, including laser-assisted in-situ keratomileusis (LASIK), lens replacement (cataract surgery), and keratoplasty (cornea transplant), now employ FSLs for their unique abilities that lead to improved clinical outcome and patient satisfaction.

The application of FSLs in medical therapeutics is a recent development, and although …


Computer Aided Diagnosis Of Oral Cancer: Using Time-Step Ct Images, Jonathan T. Scott Jan 2015

Computer Aided Diagnosis Of Oral Cancer: Using Time-Step Ct Images, Jonathan T. Scott

Masters Theses

"In medical imaging it is a very common practice to use a technique known as Time-Step imaging in patients who might develop cancer. Time-Step imaging it a very powerful technique, however it can lead to unmanageable amounts of image data. Previously the only way to search all of this data was to manually look through all of the files. This had to be done by trained professionals who knew what to look for within the images and make a judgment about the patient based on the images. This paper discusses the development of an algorithm to have a computer search …


Sensitivity Of Mri-Guided Near-Infrared Spectroscopy Clinical Breast Exam Data And Its Impact On Diagnostic Performance, Michael A. Mastanduno, Junqing Xu, Fadi El-Ghussein, Shudong Jiang, Hong Yin, Yan Zhao, Kelly E. Michaelson, Ke Wang, Fang Ren, Brian W. Pogue, Keith D. Paulsen Aug 2014

Sensitivity Of Mri-Guided Near-Infrared Spectroscopy Clinical Breast Exam Data And Its Impact On Diagnostic Performance, Michael A. Mastanduno, Junqing Xu, Fadi El-Ghussein, Shudong Jiang, Hong Yin, Yan Zhao, Kelly E. Michaelson, Ke Wang, Fang Ren, Brian W. Pogue, Keith D. Paulsen

Dartmouth Scholarship

In this study, data from breast MRI-guided near infrared spectroscopy (NIRS) exams delivered to 44 patients scheduled for surgical resection (ending in 16 benign and 28 malignant diagnoses) were analyzed using a spatial sensitivity metric to quantify the adequacy of the optical measurements for interrogating the tumor region of interest, as derived from the concurrent MRI scan. Along with positional sensitivity, the incorporation of spectral priors and the selection of an appropriate regularization parameter in the image reconstruction were considered, and found to influence the diagnostic accuracy of the recovered images. Once optimized, the MRI/NIRS data was able to differentiate …


Three Dimensional Quantification Of Angiotensin Ii-Induced Murine Abdominal Aortic Aneurysms Using High Frequency Ultrasound, Amelia R. Adelsperger, Alexa A. Yrineo, Hilary D. Schroeder, Ashley Nicole Blaize, Katherine E. Wilson, Evan H. Phillips, Frederick W. Damen, Craig J. Goergen Aug 2014

Three Dimensional Quantification Of Angiotensin Ii-Induced Murine Abdominal Aortic Aneurysms Using High Frequency Ultrasound, Amelia R. Adelsperger, Alexa A. Yrineo, Hilary D. Schroeder, Ashley Nicole Blaize, Katherine E. Wilson, Evan H. Phillips, Frederick W. Damen, Craig J. Goergen

The Summer Undergraduate Research Fellowship (SURF) Symposium

Abdominal aortic aneurysms (AAAs), a localized dilation of the vessel wall of 50% or more above normal, claims approximately 14,000 U.S. lives yearly due to aortic rupture. This commonly asymptomatic disease can only be treated by endovascular stent grafts or invasive surgery, usually after the AAA diameter reaches 5 cm. Because these treatment methods carry serious risk, stem cell therapy is being explored in order to provide a low risk option for managing smaller AAAs. To determine if stem cell therapy, once administered, could stabilize or reduce AAA growth, baseline 3D ultrasound measurements in a control group were first needed. …


Nerve Fiber Diameter Measurements Using Hematoxylin And Eosin Staining And Brightfield Microscopy To Assess The Novel Method Of Characterizing Peripheral Nerve Fiber Distributions By Group Delay, Jorge Arturo Vazquez Aug 2014

Nerve Fiber Diameter Measurements Using Hematoxylin And Eosin Staining And Brightfield Microscopy To Assess The Novel Method Of Characterizing Peripheral Nerve Fiber Distributions By Group Delay, Jorge Arturo Vazquez

Master's Theses

Peripheral neuropathies are a set of common diseases that affect the peripheral nervous system, causing damage to vital connections between various parts of the body and the brain and spinal cord. Different clinical conditions are known to selectively impact various size nerve fibers, which often makes it difficult to diagnose which peripheral neuropathy a patient might have. The nerve conduction velocity diagnostic test provides clinically useful information in the diagnosis of some peripheral neuropathies. This method is advantageous because it tends to be minimally invasive yet it provides valuable diagnostic information. However, this test does not determine characteristics of peripheral …


Fluid Powered Miniature In Vivo Robots For Minimally Invasive Surgery (Mis), Abolfazl Pourghodrat Aug 2014

Fluid Powered Miniature In Vivo Robots For Minimally Invasive Surgery (Mis), Abolfazl Pourghodrat

Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research

Minimizing the invasiveness of surgery is believed to improve patient outcomes. Bleeding, infection, and pain are major concerns in surgery afflicting patients for decades. Minimally invasive techniques have come into play to reduce these concerns and smooth the evolution of abdominal surgery to a scarless process where nearly all surgeries can be performed without a skin incision. Technology continually advances the frontier of development of novel surgical devices to implement less invasive surgical techniques.

Fusion of robotics and Minimally Invasive Surgery (MIS) has created new opportunities to develop diagnostic and therapeutic tools. Surgical robotics is advancing from externally actuated systems …


Frontal White Matter Integrity In Adults With Down Syndrome With And Without Dementia, David K. Powell, Allison Caban-Holt, Greg A. Jicha, William C. Robertson, Roberta Davis, Brian T. Gold, Frederick A. Schmitt, Elizabeth Head Jul 2014

Frontal White Matter Integrity In Adults With Down Syndrome With And Without Dementia, David K. Powell, Allison Caban-Holt, Greg A. Jicha, William C. Robertson, Roberta Davis, Brian T. Gold, Frederick A. Schmitt, Elizabeth Head

Magnetic Resonance Imaging and Spectroscopy Center Faculty Publications

Adults with Down syndrome (DS) are at high risk for developing Alzheimer's disease after the age of 40 years. To detect white matter (WM) changes in the brain linked to dementia, fractional anisotropy (FA) from diffusion tensor imaging was used. We hypothesized that adults with DS without dementia (DS n = 10), DS with dementia (DSAD n = 10) and age matched non-DS subjects (CTL n = 10) would show differential levels of FA and an association with scores from the Brief Praxis Test and the Severe Impairment Battery. WM integrity differences in DS compared with CTL were found predominantly …


Developent Of A Phospholipid Encapsulation Process For Quantum Dots To Be Used In Biologic Applications, Logan Grimes Jun 2014

Developent Of A Phospholipid Encapsulation Process For Quantum Dots To Be Used In Biologic Applications, Logan Grimes

Master's Theses

The American Cancer Society predicts that 1,665,540 people will be diagnosed with cancer, and 585,720 people will die from cancer in 2014. One of the most common types of cancer in the United States is skin cancer. Melanoma alone is predicted to account for 10,000 of the cancer related deaths in 2014. As a highly mobile and aggressive form of cancer, melanoma is difficult to fight once it has metastasized through the body. Early detection in such varieties of cancer is critical in improving survival rates in afflicted patients. Present methods of detection rely on visual examination of suspicious regions …


Extraction Of Intrinsic Fluorescence From Single Fiber Fluorescence Measurements On A Turbid Medium: Experimental Validation, U. A. Gamm, C. L. Hoy, F. Van Leeuwen - Van Zaane, H. J. C. M. Sterenborg, S. C. Kanick, D J. Robinson, A. Amelink May 2014

Extraction Of Intrinsic Fluorescence From Single Fiber Fluorescence Measurements On A Turbid Medium: Experimental Validation, U. A. Gamm, C. L. Hoy, F. Van Leeuwen - Van Zaane, H. J. C. M. Sterenborg, S. C. Kanick, D J. Robinson, A. Amelink

Dartmouth Scholarship

Abstract

The detailed mechanisms associated with the influence of scattering and absorption properties on the fluorescence intensity sampled by a single optical fiber have recently been elucidated based on Monte Carlo simulated data. Here we develop an experimental single fiber fluorescence (SFF) spectroscopy setup and validate the Monte Carlo data and semi-empirical model equation that describes the SFF signal as a function of scattering. We present a calibration procedure that corrects the SFF signal for all system-related, wavelength dependent transmission efficiencies to yield an absolute value of intrinsic fluorescence. The validity of the Monte Carlo data and semi-empirical model is …


Utilizing Fast Spin Echo Mri To Reduce Image Artifacts And Improve Implant/Tissue Interface Detection In Refractory Parkinson’S Patients With Deep Brain Stimulators, Subhendra N. Sarkar, Pooja R. Sarkar, Efstathios Papavassiliou, Rafael Rojas Feb 2014

Utilizing Fast Spin Echo Mri To Reduce Image Artifacts And Improve Implant/Tissue Interface Detection In Refractory Parkinson’S Patients With Deep Brain Stimulators, Subhendra N. Sarkar, Pooja R. Sarkar, Efstathios Papavassiliou, Rafael Rojas

Publications and Research

Introduction. In medically refractory Parkinson’s disease (PD) deep-brain stimulation (DBS) is an effective therapeutic tool. Postimplantation MRI is important in assessing tissue damage and DBS lead placement accuracy. We wanted to identify which MRI sequence can detectDBS leads with smallest artifactual signal void, allowing better tissue/electrode edge conspicuity.

Methods. Using an IRB approved protocol 8 advanced PDpatientswere imagedwithinMRconditional safety guidelines at lowRF power (SAR ≤ 0.1 W/kg) in coronal plane at 1.5T by various sequences.The image slices were subjectively evaluated for diagnostic quality and the lead contact diameters were compared to identify a sequence least affected by metallic leads.

Results …


Advances In Optics For Biotechnology, Medicine And Surgery, Maryann Fitzmaurice, Brian W. Pogue, Guillermo J. Tearney, James W. Tunnell Jan 2014

Advances In Optics For Biotechnology, Medicine And Surgery, Maryann Fitzmaurice, Brian W. Pogue, Guillermo J. Tearney, James W. Tunnell

Dartmouth Scholarship

The guest editors introduce a Biomedical Optics Express feature issue that includes contributions from participants at the 2013 conference on Advances in Optics for Biotechnology, Medicine and Surgery XIII.


Cervical Cancer Histology Image Feature Extraction And Classification, Peng Guo Jan 2014

Cervical Cancer Histology Image Feature Extraction And Classification, Peng Guo

Masters Theses

"Cervical cancer, the second most common cancer affecting women worldwide and the most common in developing countries can be cured if detected early and treated. Expert pathologists routinely visually examine histology slides for cervix tissue abnormality assessment. In previous research, an automated, localized, fusion-based approach was investigated for classifying squamous epithelium into Normal, CIN1, CIN2, and CIN3 grades of cervical intraepithelial neoplasia (CIN) based on image analysis of 62 digitized histology images obtained through the National Library of Medicine. In this research, CIN grade assessments from two pathologists are analyzed and are used to facilitate atypical cell concentration feature development …


A Nonrigid Registration Method For Correcting Brain Deformation Induced By Tumor Resection, Yixun Liu, Chengjun Yao, Fotis Drakopoulos, Jinsong Wu, Liangfu Zhou, Nikos Chrisochoides Jan 2014

A Nonrigid Registration Method For Correcting Brain Deformation Induced By Tumor Resection, Yixun Liu, Chengjun Yao, Fotis Drakopoulos, Jinsong Wu, Liangfu Zhou, Nikos Chrisochoides

Computer Science Faculty Publications

Purpose: This paper presents a nonrigid registration method to align preoperative MRI with intraoperative MRI to compensate for brain deformation during tumor resection. This method extends traditional point-based nonrigid registration in two aspects: (1) allow the input data to be incomplete and (2) simulate the underlying deformation with a heterogeneous biomechanical model.

Methods: The method formulates the registration as a three-variable (point correspondence, deformation field, and resection region) functional minimization problem, in which point correspondence is represented by a fuzzy assign matrix; Deformation field is represented by a piecewise linear function regularized by the strain energy of a heterogeneous biomechanical …


Dopaminergic Modulation Of Memory And Affective Processing In Parkinson Depression, Lee X. Blonder, John T. Slevin, Richard J. Kryscio, Catherine A. Martin, Anders H. Andersen, Charles D Smith, Frederick A. Schmitt Nov 2013

Dopaminergic Modulation Of Memory And Affective Processing In Parkinson Depression, Lee X. Blonder, John T. Slevin, Richard J. Kryscio, Catherine A. Martin, Anders H. Andersen, Charles D Smith, Frederick A. Schmitt

Magnetic Resonance Imaging and Spectroscopy Center Faculty Publications

Depression is common in Parkinson's disease and is associated with cognitive impairment. Dopaminergic medications are effective in treating the motor symptoms of Parkinson's disease; however, little is known regarding the effects of dopaminergic pharmacotherapy on cognitive function in depressed Parkinson patients. This study examines the neuropsychological effects of dopaminergic pharmacotherapy in Parkinsonian depression. We compared cognitive function in depressed and non-depressed Parkinson patients at two time-points: following overnight withdrawal and after the usual morning regimen of dopaminergic medications. A total of 28 non-demented, right-handed patients with mild to moderate idiopathic Parkinson's disease participated. Ten of these patients were depressed according …


Spectral Discrimination Of Breast Pathologies In Situ Using Spatial Frequency Domain Imaging, Ashley M. Laughney, Venkataramanan Krishnaswamy, Elizabeth J. Rizzo, Mary C. Schwab, Richard J. Barth, David J. Cuccia, Bruce J. Tromberg, Keith D. Paulsen, Brian W. Pogue, Wendy A. Wells Aug 2013

Spectral Discrimination Of Breast Pathologies In Situ Using Spatial Frequency Domain Imaging, Ashley M. Laughney, Venkataramanan Krishnaswamy, Elizabeth J. Rizzo, Mary C. Schwab, Richard J. Barth, David J. Cuccia, Bruce J. Tromberg, Keith D. Paulsen, Brian W. Pogue, Wendy A. Wells

Dartmouth Scholarship

Introduction: Nationally, 25% to 50% of patients undergoing lumpectomy for local management of breast cancer require a secondary excision because of the persistence of residual tumor. Intraoperative assessment of specimen margins by frozen-section analysis is not widely adopted in breast-conserving surgery. Here, a new approach to wide-field optical imaging of breast pathology in situ was tested to determine whether the system could accurately discriminate cancer from benign tissues before routine pathological processing.


Fluorescence Characterization Of Quantum Dots For Use As Biomarkers, Logan M. Grimes Jun 2013

Fluorescence Characterization Of Quantum Dots For Use As Biomarkers, Logan M. Grimes

Materials Engineering

Fluorescence profiles of quantum dots (QDs) were characterized to select the ideal QDs for encapsulation in phospholipids for use as biomarkers to selectively adhere to cancer cells. QDs were synthesized and extracted 0, 30, 60, and 90 seconds after precursor compounds were mixed. These extractions were isolated by extraction time. Portions from each vial were coated in a zinc sulfide shelling procedure, leaving at least half of the QD solution unshelled. These samples were characterized over four days to monitor fluctuations in fluorescence. This was done utilizing an Ocean Optics spectrometer in conjunction with Spectra Suite software. The central wavelength, …