Open Access. Powered by Scholars. Published by Universities.®
Bioimaging and Biomedical Optics Commons™
Open Access. Powered by Scholars. Published by Universities.®
- Institution
-
- Dartmouth College (16)
- Old Dominion University (10)
- Washington University in St. Louis (8)
- City University of New York (CUNY) (5)
- University of Kentucky (5)
-
- California Polytechnic State University, San Luis Obispo (4)
- University of Arkansas, Fayetteville (3)
- University of Nebraska - Lincoln (3)
- University of South Alabama (3)
- Duquesne University (2)
- Purdue University (2)
- University of Connecticut (2)
- Wayne State University (2)
- Air Force Institute of Technology (1)
- American Dental Association (1)
- Boise State University (1)
- Brigham Young University (1)
- Clemson University (1)
- Marquette University (1)
- South Dakota State University (1)
- The Texas Medical Center Library (1)
- The University of Akron (1)
- University of Nebraska Medical Center (1)
- University of Nevada, Las Vegas (1)
- Virginia Commonwealth University (1)
- Western University (1)
- Yale University (1)
- Keyword
-
- Medical imaging (8)
- Diagnosis (5)
- Computer aided diagnosis (4)
- Sensitivity and specificity (4)
- Breast neoplasms (3)
-
- Computed tomography (3)
- Computer-assisted (3)
- Equipment design (3)
- Equipment failure analysis (3)
- Female (3)
- Fluorescence (3)
- Glioma (3)
- Humans (3)
- Imaging systems (3)
- Instrumentation (3)
- Spectroscopy (3)
- Tissues (3)
- Algorithms (2)
- Analysis (2)
- Computerized tomography (2)
- Contrast agents (2)
- Database systems (2)
- Deep learning (2)
- Diagnostic imaging (2)
- Feature selection algorithm (2)
- Head and neck cancer (2)
- Image processing (2)
- Imaging (2)
- Iterative algorithm (2)
- Machine learning (2)
- Publication Year
- Publication
-
- Dartmouth Scholarship (13)
- Electrical & Computer Engineering Faculty Publications (7)
- McKelvey School of Engineering Graduate Student Theses & Dissertations (7)
- Biomedical Engineering Undergraduate Honors Theses (3)
- Master's Theses (3)
-
- Publications and Research (3)
- Theses and Dissertations--Biomedical Engineering (3)
- Dartmouth College Ph.D Dissertations (2)
- Materials Engineering (2)
- Theses and Dissertations (2)
- All Dissertations (1)
- Bachelors’ Theses (1)
- Biological Sciences Faculty Publications (1)
- Biomedical Engineering Western Regional Conference (1)
- Department of Civil and Environmental Engineering: Dissertations, Theses, and Student Research (1)
- Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research (1)
- Department of Special Education and Communication Disorders: Faculty Publications (1)
- Discovery Undergraduate Interdisciplinary Research Internship (1)
- Dissertations and Theses (1)
- Dissertations and Theses (Open Access) (1)
- Dissertations, Theses, and Capstone Projects (1)
- EVMS School of Health Professions Faculty Publications (1)
- Electrical & Computer Engineering Theses & Dissertations (1)
- Electrical & Systems Engineering Publications and Presentations (1)
- Electronic Theses and Dissertations (1)
- Graduate Theses and Dissertations (2019 - present) (1)
- Honors Scholar Theses (1)
- Honors Theses (1)
- Independent Student Projects and Publications (1)
- Radiology Faculty Publications (1)
- Publication Type
Articles 61 - 79 of 79
Full-Text Articles in Bioimaging and Biomedical Optics
Automated Point-Of-Care Image Processing Methodology For The Diagnosis Of Malaria, Michael B. Jorgensen
Automated Point-Of-Care Image Processing Methodology For The Diagnosis Of Malaria, Michael B. Jorgensen
Master's Theses
Malaria has profoundly influenced human history for over four thousand years and despite numerous attempts at eradication, the prevention, diagnosis, and treatment of malaria have been largely ineffective. More than five hundred million people are affected by malaria every year resulting in over one million deaths. Drug resistance development by the parasite has diminished the effectiveness of numerous treatment options due, in part, to overtreatment of negative patients based on insufficient clinical algorithms and diagnostic methods. The goal of this research was to develop an image analysis algorithm to diagnose malaria with a high degree of sensitivity and specificity in …
Noninvasive Near-Infrared Diffuse Optical Monitoring Of Cerebral Hemodynamics And Autoregulation, Ran Cheng
Noninvasive Near-Infrared Diffuse Optical Monitoring Of Cerebral Hemodynamics And Autoregulation, Ran Cheng
Theses and Dissertations--Biomedical Engineering
Many cerebral diseases are associated with abnormal cerebral hemodynamics and impaired cerebral autoregulation (CA). CA is a mechanism to maintain cerebral blood flow (CBF) stable when mean arterial pressure (MAP) fluctuates. Evaluating these abnormalities requires direct measurements of cerebral hemodynamics and MAP. Several near-infrared diffuse optical instruments have been developed in our laboratory for hemodynamic measurements including near-infrared spectroscopy (NIRS), diffuse correlation spectroscopy (DCS), hybrid NIRS/DCS, and dual-wavelength DCS flow-oximeter. We utilized these noninvasive technologies to quantify CBF and cerebral oxygenation in different populations under different physiological conditions/manipulations. A commercial finger plethysmograph was used to continuously monitor MAP. For investigating …
A Digital X-Ray Tomosynthesis Coupled Near Infrared Spectral Tomography System For Dual-Modality Breast Imaging, Venkataramanan Krishnaswamy, Kelly E. Michaelsen, Brian W. Pogue, Steven P. Poplack, Ian Shaw, Ken Defrietas, Ken Brooks, Keith D. Paulsen
A Digital X-Ray Tomosynthesis Coupled Near Infrared Spectral Tomography System For Dual-Modality Breast Imaging, Venkataramanan Krishnaswamy, Kelly E. Michaelsen, Brian W. Pogue, Steven P. Poplack, Ian Shaw, Ken Defrietas, Ken Brooks, Keith D. Paulsen
Dartmouth Scholarship
A Near Infrared Spectral Tomography (NIRST) system has been developed and integrated into a commercial Digital Breast Tomosynthesis (DBT) scanner to allow structural and functional imaging of breast in vivo. The NIRST instrument uses an 8-wavelength continuous wave (CW) laser-based scanning source assembly and a 75-element silicon photodiode solid-state detector panel to produce dense spectral and spatial projection data from which spectrally constrained 3D tomographic images of tissue chromophores are produced. Integration of the optical imaging system into the DBT scanner allows direct co-registration of the optical and DBT images, while also facilitating the synergistic use of x-ray contrast as …
Quantitative Cherenkov Emission Spectroscopy For Tissue Oxygenation Assessment, Johan Axelsson, Adam K. Glaser, David J. Gladstone, Brian W. Pogue
Quantitative Cherenkov Emission Spectroscopy For Tissue Oxygenation Assessment, Johan Axelsson, Adam K. Glaser, David J. Gladstone, Brian W. Pogue
Dartmouth Scholarship
Measurements of Cherenkov emission in tissue during radiation therapy are shown to enable estimation of hemoglobin oxygen saturation non-invasively, through spectral fitting of the spontaneous emissions from the treated tissue. Tissue oxygenation plays a critical role in the efficacy of radiation therapy to kill tumor tissue. Yet in-vivo measurement of this has remained elusive in routine use because of the complexity of oxygen measurement techniques. There is a spectrally broad emission of Cherenkov light that is induced during the time of irradiation, and as this travels through tissue from the point of the radiation deposition, the tissue absorption and scatter …
Determining A Method For Rendering Low Cost Cdse(Zns) Core(Shell) Quantum Dots Aqueous Soluble Via Amphiphilic Polymer Wrapping, Patrick Mcbride
Determining A Method For Rendering Low Cost Cdse(Zns) Core(Shell) Quantum Dots Aqueous Soluble Via Amphiphilic Polymer Wrapping, Patrick Mcbride
Materials Engineering
Herein is described the procedure of two amphiphilic polymer wrapping techniques that may be employed for obtaining aqueous soluble quantum dots (QDs) for use in biological fluorescent imaging applications. The advent of QDs has led to new nanoscale fluorescent materials that exhibit unparalleled quantum yields (QYs), high resistance to photobleaching, tunable emissions, and
absorption over a large optical range. However, the QD synthesis employed here at Cal Poly to obtain bright, photostable CdSe(ZnS) core(shell) QDs involves the use of organic solvents and surfactants, leading to hydrophobic QDs. Since all of biology relies on aqueous solubility, this hydrophobicity creates a major …
Bcc Skin Cancer Diagnosis Based On Texture Analysis Techniques, Shao-Hui Chuang, Xiaoyan Sun, Wen-Yu Chang, Gwo-Shing Chen, Adam Huang, Jiang Li, Frederic D. Mckenzie
Bcc Skin Cancer Diagnosis Based On Texture Analysis Techniques, Shao-Hui Chuang, Xiaoyan Sun, Wen-Yu Chang, Gwo-Shing Chen, Adam Huang, Jiang Li, Frederic D. Mckenzie
Electrical & Computer Engineering Faculty Publications
In this paper, we present a texture analysis based method for diagnosing the Basal Cell Carcinoma (BCC) skin cancer using optical images taken from the suspicious skin regions. We first extracted the Run Length Matrix and Haralick texture features from the images and used a feature selection algorithm to identify the most effective feature set for the diagnosis. We then utilized a Multi-Layer Perceptron (MLP) classifier to classify the images to BCC or normal cases. Experiments showed that detecting BCC cancer based on optical images is feasible. The best sensitivity and specificity we achieved on our data set were 94% …
Prediction Of Brain Tumor Progression Using Multiple Histogram Matched Mri Scans, Debrup Banerjee, Loc Tran, Jiang Li, Yuzhong Shen, Frederic Mckenzie, Jihong Wang, Ronald M. Summers (Ed.), Bram Van Ginneken (Ed.)
Prediction Of Brain Tumor Progression Using Multiple Histogram Matched Mri Scans, Debrup Banerjee, Loc Tran, Jiang Li, Yuzhong Shen, Frederic Mckenzie, Jihong Wang, Ronald M. Summers (Ed.), Bram Van Ginneken (Ed.)
Electrical & Computer Engineering Faculty Publications
In a recent study [1], we investigated the feasibility of predicting brain tumor progression based on multiple MRI series and we tested our methods on seven patients' MRI images scanned at three consecutive visits A, B and C. Experimental results showed that it is feasible to predict tumor progression from visit A to visit C using a model trained by the information from visit A to visit B. However, the trained model failed when we tried to predict tumor progression from visit B to visit C, though it is clinically more important. Upon a closer look at the MRI scans …
Automatic Exposure Control And Estimation Of Effective System Noise In Diffuse Fluorescence Tomography, Dax L. Kepshire, Hamid Dehghani, Frederic Leblond, Brian W. Pogue
Automatic Exposure Control And Estimation Of Effective System Noise In Diffuse Fluorescence Tomography, Dax L. Kepshire, Hamid Dehghani, Frederic Leblond, Brian W. Pogue
Dartmouth Scholarship
A diffuse fluorescence tomography system, based upon time-correlated single photon counting, is presented with an automated algorithm to allow dynamic range variation through exposure control. This automated exposure control allows the upper and lower detection levels of fluorophore to be extended by an order of magnitude beyond the previously published performance and benefits in a slight decrease in system effective noise. The effective noise level is used as a metric to characterize the system performance, integrating both model-mismatch and calibration bias errors into a single parameter. This effective error is near 7% of the reconstructed fluorescent yield value, when imaging …
Statistical Hypothesis Testing For Postreconstructed And Postregistered Medical Images, Eugene Demidenko
Statistical Hypothesis Testing For Postreconstructed And Postregistered Medical Images, Eugene Demidenko
Dartmouth Scholarship
Postreconstructed and postregistered medical images are typically treated as the raw data, implicitly assuming that those operations are error free. We question this assumption and explore how the precision of reconstruction and affine registration can be assessed by the image covariance matrix and confidence interval, called the confidence eigenimage, using a statistical model-based approach. Various hypotheses may be tested after image reconstruction and registration using classical statistical hypothesis testing vehicles: Is there a statistically significant difference between images? Does the intensity at a specific location or area of interest belong to the “normal” range? Is there a tumor? Does the …
Investigation Of Magnetic Resonance Imaging And Spectroscopy For The Detection Of Breast Cancer, Robert Thomas Etnire
Investigation Of Magnetic Resonance Imaging And Spectroscopy For The Detection Of Breast Cancer, Robert Thomas Etnire
UNLV Theses, Dissertations, Professional Papers, and Capstones
Magnetic resonance imaging (MRI) of the breast offers an alternative to screening mammography which may benefit those women at high risk for breast cancer, women under the age of 40, and those with dense breast tissue. One concern with MRI is the number of high false positives. Coupling MRI with magnetic resonance spectroscopy(MRS) may lower the number of false positives, and thus improve the diagnostic capabilities of MRI for the clinician. MRS for breast imaging focuses on the total choline containing compounds in the spectra in the suspected breast lesion to analyze areas of concern. The results of the study …
Parameter Optimization For Image Denoising Based On Block Matching And 3d Collaborative Filtering, Ramu Pedada, Emin Kugu, Jiang Li, Zhanfeng Yue, Yuzhong Shen, Josien P.W. Pluim (Ed.), Benoit M. Dawant (Ed.)
Parameter Optimization For Image Denoising Based On Block Matching And 3d Collaborative Filtering, Ramu Pedada, Emin Kugu, Jiang Li, Zhanfeng Yue, Yuzhong Shen, Josien P.W. Pluim (Ed.), Benoit M. Dawant (Ed.)
Electrical & Computer Engineering Faculty Publications
Clinical MRI images are generally corrupted by random noise during acquisition with blurred subtle structure features. Many denoising methods have been proposed to remove noise from corrupted images at the expense of distorted structure features. Therefore, there is always compromise between removing noise and preserving structure information for denoising methods. For a specific denoising method, it is crucial to tune it so that the best tradeoff can be obtained. In this paper, we define several cost functions to assess the quality of noise removal and that of structure information preserved in the denoised image. Strength Pareto Evolutionary Algorithm 2 (SPEA2) …
Automatic Diagnosis For Prostate Cancer Using Run-Length Matrix Method, Xiaoyan Sun, Shao-Hui Chuang, Jiang Li, Frederic Mckenzie, Nico Karssemeijer (Ed.), Maryellen L. Giger (Ed.)
Automatic Diagnosis For Prostate Cancer Using Run-Length Matrix Method, Xiaoyan Sun, Shao-Hui Chuang, Jiang Li, Frederic Mckenzie, Nico Karssemeijer (Ed.), Maryellen L. Giger (Ed.)
Electrical & Computer Engineering Faculty Publications
Prostate cancer is the most common type of cancer and the second leading cause of cancer death among men in US1. Quantitative assessment of prostate histology provides potential automatic classification of prostate lesions and prediction of response to therapy. Traditionally, prostate cancer diagnosis is made by the analysis of prostate-specific antigen (PSA) levels and histopathological images of biopsy samples under microscopes. In this application, we utilize a texture analysis method based on the run-length matrix for identifying tissue abnormalities in prostate histology. A tissue sample was collected from a radical prostatectomy, H&E fixed, and assessed by a pathologist …
Methodology Development For Three-Dimensional Mr-Guided Near Infrared Spectroscopy Of Breast Tumors, Colin M. Carpenter, Subhadra Srinivasan, Brian W. Pogue, Keith D. Paulsen
Methodology Development For Three-Dimensional Mr-Guided Near Infrared Spectroscopy Of Breast Tumors, Colin M. Carpenter, Subhadra Srinivasan, Brian W. Pogue, Keith D. Paulsen
Dartmouth Scholarship
Combined Magnetic Resonance (MR) and Near Infrared Spectroscopy (NIRS) has been proposed as a unique method to quantify hemodynamics, water content, and cellular size and packing density of breast tumors, as these tissue constituents can be quantified with increased resolution and overlaid on the structural features identified by the MR. However, the choices in how to reconstruct and visualize this information can have a dramatic impact on the feasibility of implementing this modality in the clinic. This is especially true in 3 dimensions, as there is often limited optical sampling of the breast tissue, and methods need to accurately reflect …
Medical Image Modeling And Processing, Ramu Pedada
Medical Image Modeling And Processing, Ramu Pedada
Electrical & Computer Engineering Theses & Dissertations
During the last few decades of the twentieth century, medical imaging has been playing a prominent role in many fields of biomedical research and clinical practice. Image modalities such as x-rays, computed tomography (CT), and magnetic resonance images (MRI) have all been valuable additions to the radiologist's arsenal of imaging tools. Medical images assure quality diagnosis and patient safety by gathering valuable information without invading the human body. Apart from clinical diagnosis, medical images are used as tools for education where they are used for training individuals before operating on a patient. Many medical educators tum to simulation based training …
Using Pareto Fronts To Evaluate Polyp Detection Algorithms For Ct Colonography, Adam Huang, Jiang Li, Ronald M. Summers, Nicholas Petrick, Amy K. Hara
Using Pareto Fronts To Evaluate Polyp Detection Algorithms For Ct Colonography, Adam Huang, Jiang Li, Ronald M. Summers, Nicholas Petrick, Amy K. Hara
Electrical & Computer Engineering Faculty Publications
We evaluate and improve an existing curvature-based region growing algorithm for colonic polyp detection for our CT colonography (CTC) computer-aided detection (CAD) system by using Pareto fronts. The performance of a polyp detection algorithm involves two conflicting objectives, minimizing both false negative (FN) and false positive (FP) detection rates. This problem does not produce a single optimal solution but a set of solutions known as a Pareto front. Any solution in a Pareto front can only outperform other solutions in one of the two competing objectives. Using evolutionary algorithms to find the Pareto fronts for multi-objective optimization problems has been …
Wavelet Analysis In Virtual Colonoscopy, Sharon Greenblum, Jiang Li, Adam Huang, Ronald M. Summers, Armando Manduca (Ed.), Amir A. Amini (Ed.)
Wavelet Analysis In Virtual Colonoscopy, Sharon Greenblum, Jiang Li, Adam Huang, Ronald M. Summers, Armando Manduca (Ed.), Amir A. Amini (Ed.)
Electrical & Computer Engineering Faculty Publications
The computed tomographic colonography (CTC) computer aided detection (CAD) program is a new method in development to detect colon polyps in virtual colonoscopy. While high sensitivity is consistently achieved, additional features are desired to increase specificity. In this paper, a wavelet analysis was applied to CTCCAD outputs in an attempt to filter out false positive detections. 52 CTCCAD detection images were obtained using a screen capture application. 26 of these images were real polyps, confirmed by optical colonoscopy and 26 were false positive detections. A discrete wavelet transform of each image was computed with the MATLAB wavelet toolbox using the …
Applications Of Wavelet Transforms In Biomedical Optoacoustics, Zibiao Wei, Shujun Yang, Amin N. Dharamsi, Barbara Hargrave
Applications Of Wavelet Transforms In Biomedical Optoacoustics, Zibiao Wei, Shujun Yang, Amin N. Dharamsi, Barbara Hargrave
Biological Sciences Faculty Publications
We discuss the utility of wavelet transform methods in signal processing in general, and in particular, demonstrate the technique in optoacoustic applications. In several optoacoustic experiments with different samples, we have successfully enhanced the signal to noise ratios. Wavelet transforms optimize resolution by utilizing a tailored, variable time-window in different frequency regions. The technique's great advantage lies in the fact that the wavelet transform adds some redundancy to the original signal, and some desired features can be enhanced in the transformed space. In addition, proper choice of the basis set allows a sparse representation of the signal. Therefore, even when …
Clustered Microcalcification Detection Using Optimized Difference Of Gaussians, Edward M. Ochoa
Clustered Microcalcification Detection Using Optimized Difference Of Gaussians, Edward M. Ochoa
Theses and Dissertations
The objective of this thesis is to design an automated microcalcification detection system to be used as an aid in radiologic mammogram interpretation. This research proposes the following methodology for clustered microcalcification detection. First, preprocess the digitized film mammogram to reduce digitization noise. Second, spatially filter the image with a difference of Gaussians (DoG) kernel. To detect potential microcalcifications, segment the filtered image using global and local thresholding. Next, cluster and index these detections into regions of interest (ROIs). Identify ROIs on the digitized image (or hardcopy printout) for final radiologic diagnosis.
Soft X-Rays, William F. Roherty
Soft X-Rays, William F. Roherty
Bachelors’ Theses
Traditionally, radiation of those wavelengths produced by a potential of from 2 to 25kv. has been classified as "Grenz" or "soft" x-rays. The peculiar property of this radiation is its low penetrating power. While being transparent to more energetic radiation, animal tissue and similar materials are sufficiently opaque to Grenz rays as to be studied in detail. Since the radiation is of the continuous type, it can be made soft enough to reveal any object, providing, of course, that the tube window and object medium be not opaque. Soft x-rays are produced in exactly the same manner as others, except …