Open Access. Powered by Scholars. Published by Universities.®

Biomedical Engineering and Bioengineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Finite element analysis

Discipline
Institution
Publication Year
Publication
Publication Type

Articles 31 - 53 of 53

Full-Text Articles in Biomedical Engineering and Bioengineering

Characterizing Anisotropy In Fibrous Soft Materials By Mr Elastography Of Slow And Fast Shear Waves, John Larson Schmidt Dec 2017

Characterizing Anisotropy In Fibrous Soft Materials By Mr Elastography Of Slow And Fast Shear Waves, John Larson Schmidt

McKelvey School of Engineering Graduate Student Theses & Dissertations

The general objective of this work was to develop experimental methods based on magnetic resonance elastography (MRE) to characterize fibrous soft materials. Mathematical models of tissue biomechanics capable of predicting injury, such as traumatic brain injury (TBI), are of great interest and potential. However, the accuracy of predictions from such models depends on accuracy of the underlying material parameters. This dissertation describes work toward three aims. First, experimental methods were designed to characterize fibrous materials based on a transversely isotropic material model. Second, these methods are applied to characterize the anisotropic properties of white matter brain tissue ex vivo. Third, …


Finite Element Simulation And Additive Manufacturing Of Stiffness-Matched Niti Fixation Hardware For Mandibular Reconstruction Surgery, Ahmadreza Jahadakbar, Narges Shayesteh Moghaddam, Amirhesam Amerinatanzi, David Dean, Haluk E. Karaca, Mohammad Elahinia Dec 2016

Finite Element Simulation And Additive Manufacturing Of Stiffness-Matched Niti Fixation Hardware For Mandibular Reconstruction Surgery, Ahmadreza Jahadakbar, Narges Shayesteh Moghaddam, Amirhesam Amerinatanzi, David Dean, Haluk E. Karaca, Mohammad Elahinia

Mechanical Engineering Faculty Publications

Process parameters and post-processing heat treatment techniques have been developed to produce both shape memory and superelastic NiTi using Additive Manufacturing. By introducing engineered porosity, the stiffness of NiTi can be tuned to the level closely matching cortical bone. Using additively manufactured porous superelastic NiTi, we have proposed the use of patient-specific, stiffness-matched fixation hardware, for mandible skeletal reconstructive surgery. Currently, Ti-6Al-4V is the most commonly used material for skeletal fixation devices. Although this material offers more than sufficient strength for immobilization during the bone healing process, the high stiffness of Ti-6Al-4V implants can cause stress shielding. In this paper, …


Injury Risk Assessment Of The Femur In Children With Osteogenesis Imperfecta, Jessica Marie Fritz Apr 2016

Injury Risk Assessment Of The Femur In Children With Osteogenesis Imperfecta, Jessica Marie Fritz

Dissertations (1934 -)

Osteogenesis imperfecta (OI) is a genetic disorder characterized by increased bone fragility and decreased bone mass, which leads to high rates of bone fracture. OI has a prevalence of 1/5,000 to 1/10,000 in the United States. About 90% of persons with OI have a genetic mutation in the coding for collagen type I, which is the major protein of connective tissues, including bone. While its prevalence classifies it as a rare disease, it is the most common disorder of bone etiology. Until recently, little was known about the mechanics and materials of OI bone or their impact on fracture risk. …


Computational Assessment Of Neural Probe And Brain Tissue Interface Under Transient Motion, Michael Polanco, Sebastian Bawab, Hangsoon Yoon Jan 2016

Computational Assessment Of Neural Probe And Brain Tissue Interface Under Transient Motion, Michael Polanco, Sebastian Bawab, Hangsoon Yoon

Mechanical & Aerospace Engineering Faculty Publications

The functional longevity of a neural probe is dependent upon its ability to minimize injury risk during the insertion and recording period in vivo, which could be related to motion-related strain between the probe and surrounding tissue. A series of finite element analyses was conducted to study the extent of the strain induced within the brain in an area around a neural probe. This study focuses on the transient behavior of neural probe and brain tissue interface with a viscoelastic model. Different stages of the interface from initial insertion of neural probe to full bonding of the probe by astro-glial …


Finite Element And Probabilistic Analysis Of Soft Tissue Structures Of The Human Lumbar Spine, Dana Joseph Coombs Jan 2016

Finite Element And Probabilistic Analysis Of Soft Tissue Structures Of The Human Lumbar Spine, Dana Joseph Coombs

Electronic Theses and Dissertations

Human lumbar spine mechanics are influenced by soft tissue structures. Understanding and properly modeling these structures can help determine pathology, treatment, and implant design and performance. Finite element models of the L4-L5 level of the lumbar spine are often used, which include a representation of the intervertebral disc and spinal ligaments. Validation of these models are typically based on torque rotation data from a single subject or the models use average properties reported in literature. However, experimental testing reports variation up to 40% in ligament stiffness and even greater variability for annulus fibrosis properties. Probabilistic approaches enable consideration of the …


Computational Replication Of The Patient-Specific Stenting Procedure For Coronary Artery Bifurcations: From Oct And Ct Imaging To Structural And Hemodynamics Analyses, Claudio Chiastra, Wei Wu, Benjamin Dickerhoff, Ali Aleiou, Gabriele Dubini, Hiromasa Otake, Francesco Migliavacca, John F. Ladisa Jr. Nov 2015

Computational Replication Of The Patient-Specific Stenting Procedure For Coronary Artery Bifurcations: From Oct And Ct Imaging To Structural And Hemodynamics Analyses, Claudio Chiastra, Wei Wu, Benjamin Dickerhoff, Ali Aleiou, Gabriele Dubini, Hiromasa Otake, Francesco Migliavacca, John F. Ladisa Jr.

Biomedical Engineering Faculty Research and Publications

The optimal stenting technique for coronary artery bifurcations is still debated. With additional advances computational simulations can soon be used to compare stent designs or strategies based on verified structural and hemodynamics results in order to identify the optimal solution for each individual’s anatomy. In this study, patient-specific simulations of stent deployment were performed for 2 cases to replicate the complete procedure conducted by interventional cardiologists. Subsequent computational fluid dynamics (CFD) analyses were conducted to quantify hemodynamic quantities linked to restenosis.

Patient-specific pre-operative models of coronary bifurcations were reconstructed from CT angiography and optical coherence tomography (OCT). Plaque location and …


Finite Element Analysis Of The Application Of Ultrasound-Generated Acoustic Radiation Force To Biomaterials, Nicole J. Piscopo May 2015

Finite Element Analysis Of The Application Of Ultrasound-Generated Acoustic Radiation Force To Biomaterials, Nicole J. Piscopo

Honors Scholar Theses

While most bone fractures can heal simply by being stabilized, others can take a longer time to rejoin or they could fail to merge back together completely. Numerous studies have shown the positive effects that ultrasonic therapy have had on delayed-union and non-union bone fracture repair but little is known as to what specific biological mechanisms are at play. Ultrasound may be a valuable tool for bone tissue regeneration at these fracture sites using a tissue engineering approach, however, more must be understood about its impact on stimulating tissues to heal before this can be a reality. For that reason, …


Relationships Of Long-Term Bisphosphonate Treatment With Measures Of Bone Microarchitecture And Mechanical Competence, Jonathan Joseph Ward Jan 2014

Relationships Of Long-Term Bisphosphonate Treatment With Measures Of Bone Microarchitecture And Mechanical Competence, Jonathan Joseph Ward

Theses and Dissertations--Biomedical Engineering

Oral bisphosphonate drug therapy is a common and effective treatment for osteoporosis. Little is known about the long-term effects of bisphosphonates on bone quality. This study examined the structural and mechanical properties of trabecular bone following 0-16 years of bisphosphonate treatment. Fifty-three iliac crest bone samples of Caucasian women diagnosed with low turnover osteoporosis were identified from the Kentucky Bone Registry. Forty-five were treated with oral bisphosphonates for 1 to 16 years while eight were treatment naive. A section of trabecular bone was chosen from a micro-computed tomography (Scanco µCT 40) scan of each sample for a uniaxial linearly elastic …


Analysis Of Acetabular Cup Orientation Effects On Stress Shielding In Total Hip Replacements Using Finite Element Methods, Brogan Mcguire, Jennifer Gemkow, Brad Gausewitz, Alex Georges Jun 2013

Analysis Of Acetabular Cup Orientation Effects On Stress Shielding In Total Hip Replacements Using Finite Element Methods, Brogan Mcguire, Jennifer Gemkow, Brad Gausewitz, Alex Georges

Biomedical Engineering

Improper positioning of the acetabular cup has been shown to contribute to issues such as high wear rates and dislocations in total hip replacements. The differences in contact mechanics due to varying orientation of the acetabular cup may also significantly affect strain distribution in the femur. This study examined these effects of acetabular orientation changes and their contribution to stress shielding using finite element analysis. A solid model of a cementless total hip implant was obtained using 3D point scanning and implanted virtually into a femur solid model. The implanted femur model was imported into ABAQUS and loaded with a …


Representing Intersubject Variability With A Statistical Shape And Alignment Model Of The Knee, Chandreshwar Rao Jan 2013

Representing Intersubject Variability With A Statistical Shape And Alignment Model Of The Knee, Chandreshwar Rao

Electronic Theses and Dissertations

Prior statistical shape models have not considered multiple structures in the knee joint to characterize anatomic variation which are required to investigate joint mechanics further for the successful knee replacement. Accordingly, the study's objective was to develop statistical shape and alignment model (SSAM) to capture intersubject variability and demonstrate the ability to generate realistic instances for use in finite element analysis (FEA). SSAM described the variability in the training set of 20 subjects with a series of modes of variation obtained by performing principal component analysis (PCA). PCA produced modes of variation with the first 3 modes representing 70% and …


Finite Element Analysis Of Transverse Medial Malleolar Fracture Fixation, Ruchi Chande May 2012

Finite Element Analysis Of Transverse Medial Malleolar Fracture Fixation, Ruchi Chande

Theses and Dissertations

Injury to the medial malleolus, the distal end of the tibia and one of the bones comprising the ankle joint, can occur in various loading scenarios. Open reduction/internal fixation (ORIF) to reattach the malleolar fragment to the proximal tibia can be achieved via various devices, however small fragments are particularly challenging to treat. In this study, computational finite element analysis (FEA) was utilized to investigate the fixation of transverse medial malleolar fractures by two cancellous screws or by a new fixation device, the Medial Malleolar Sled™. Cadaveric testing assessed the performance of the two constructs in both tension and torsion. …


Section Abstracts: Biomedical And General Engineering Apr 2012

Section Abstracts: Biomedical And General Engineering

Virginia Journal of Science

Abstracts of the Biomedical and General Engineering Section for the 90th Annual Meeting of the Virginia Academy of Science, May 23-25, 2012, Norfolk State University, Norfolk, Virginia.


The Influence Of Heterogeneous Meninges On The Brain Mechanics Under Primary Blast Loading, Linxia Gu, Mehdi S. Chafi, Shailesh Ganpule, Namas Chandra Apr 2012

The Influence Of Heterogeneous Meninges On The Brain Mechanics Under Primary Blast Loading, Linxia Gu, Mehdi S. Chafi, Shailesh Ganpule, Namas Chandra

Department of Mechanical and Materials Engineering: Faculty Publications

In the modeling of brain mechanics subjected to primary blast waves, there is currently no consensus on how many biological components to be used in the brain–meninges–skull complex, and what type of constitutive models to be adopted. The objective of this study is to determine the role of layered meninges in damping the dynamic response of the brain under primary blast loadings. A composite structures composed of eight solid relevant layers (including the pia, cerebrospinal fluid (CSF), dura maters) with different mechanical properties are constructed to mimic the heterogeneous human head. A hyper-viscoelastic material model is developed to better represent …


Explicit Finite Element Modeling Of The Human Lumbar Spine, Milind Rao Jan 2012

Explicit Finite Element Modeling Of The Human Lumbar Spine, Milind Rao

Electronic Theses and Dissertations

Validated finite element (FE) models of the functional spinal unit (FSU) and lumbar spine are essential in design-phase device development and in assessing the mechanics associated with normal spine function and degenerative disc disease (DDD), as well as the impact of fusion and total disc replacement (TDR). Although experimental data from fully intact specimens can be used for model calibration and validation, the contributions from the individual structures (disc, facets, and ligaments) may be inappropriately distributed. Hence, creation of decompression conditions or device implantations that require structure removal may not have the proper resulting mechanics. An explicit FE formulation may …


Development Of Physiologic Contact Models For Articular Surfaces, John Owen May 2011

Development Of Physiologic Contact Models For Articular Surfaces, John Owen

Theses and Dissertations

The superficial tangential zone (STZ) plays a significant role in normal articular cartilage’s ability to support loads and retain fluids. To date, tissue engineering efforts have not replicated normal STZ function in cartilage repairs. Finite element models were developed to examine the STZ’s role in normal and repaired articular surfaces under different contact conditions. Models were developed by incrementally adding improvements which culminated in contact loading of curved models by permeable and impermeable rigid surfaces and a normal cartilage layer. In the normal STZ, permeability was strain-dependent on volumetric strain; tension-compression nonlinearity modeled collagen behavior. Nonlinear geometry accounted for finite …


In Vitro Validation Of Finite-Element Model Of Aaa Hemodynamics Incorporating Realistic Outlet Boundary Conditions, Ethan Kung, Andrea S. Les, Francisco Medina, Ryan B. Wicker, Michael V. Mcconnell, Charles A. Taylor Feb 2011

In Vitro Validation Of Finite-Element Model Of Aaa Hemodynamics Incorporating Realistic Outlet Boundary Conditions, Ethan Kung, Andrea S. Les, Francisco Medina, Ryan B. Wicker, Michael V. Mcconnell, Charles A. Taylor

Publications

The purpose of this study is to validate numerical simulations of flow and pressure in an abdominal aortic aneurysm (AAA) using phase-contrast magnetic resonance imaging (PCMRI) and an in vitro phantom under physiological flow and pressure conditions. We constructed a two-outlet physical flow phantom based on patient imaging data of an AAA and developed a physical Windkessel model to use as outlet boundary conditions. We then acquired PCMRI data in the phantom while it operated under conditions mimicking a resting and a light exercise physiological state. Next, we performed in silico numerical simulations and compared experimentally measured velocities, flows, and …


Local Hemodynamic Changes Caused By Main Branch Stent Implantation And Subsequent Side Branch Balloon Angioplasty In A Representative Coronary Bifurcation, Andrew R. Williams, Bon-Kwon Koo, Timothy J. Gundert, Peter J. Fitzgerald, John F. Ladisa Jr. Aug 2010

Local Hemodynamic Changes Caused By Main Branch Stent Implantation And Subsequent Side Branch Balloon Angioplasty In A Representative Coronary Bifurcation, Andrew R. Williams, Bon-Kwon Koo, Timothy J. Gundert, Peter J. Fitzgerald, John F. Ladisa Jr.

Biomedical Engineering Faculty Research and Publications

Abnormal blood flow patterns promoting inflammation, cellular proliferation, and thrombosis may be established by local changes in vessel geometry after stent implantation in bifurcation lesions. Our objective was to quantify altered hemodynamics due to main vessel (MV) stenting and subsequent virtual side branch (SB) angioplasty in a coronary bifurcation by using computational fluid dynamics (CFD) analysis. CFD models were generated from representative vascular dimensions and intravascular ultrasound images. Time-averaged wall shear stress (TAWSS), oscillatory shear index (OSI), and fractional flow reserve (FFR) were quantified. None of the luminal surface was exposed to low TAWSS (/cm2) in the nondiseased bifurcation model. …


A Linear Finite Element Acoustic Fluid-Structure Model Of Ultrasonic Angioplasty In Vivo, Mark Wylie, Garrett Mcguinness, Graham Gavin Mar 2010

A Linear Finite Element Acoustic Fluid-Structure Model Of Ultrasonic Angioplasty In Vivo, Mark Wylie, Garrett Mcguinness, Graham Gavin

Articles

The delivery of high-power ultrasonic energy via small diameter wire waveguides represents a new alternative therapy for the treatment of chronic totally occluded arteries (CTOs). This type of energy manifests itself as a mechanical vibration at the distal-tip of the waveguide with amplitudes of vibration up to 60 µm and at frequencies of 20- 50 kHz. Disruption of diseased tissue is reported to be a result of direct mechanical ablation, cavitation, pressure components and acoustic streaming and that ablation was only evident above the cavitation threshold. This work presents a linear finite element acoustic fluid-structure model of an ultrasonic angioplasty …


Computational Structural Modelling Of Coronary Stent Deployment: A Review, David Martin, Fergal Boyle Jan 2010

Computational Structural Modelling Of Coronary Stent Deployment: A Review, David Martin, Fergal Boyle

Articles

The finite element (FE) method is a powerful investigative tool in the field of biomedical engineering, particularly in the analysis of medical devices such as coronary stents whose performance is extremely difficult to evaluate in vivo. In recent years, a number of FE studies have been carried out to simulate the deployment of coronary stents, and the results of these studies have been utilised to assess and optimise the performance of these devices. The aim of this paper is to provide a thorough review of the state-of-the-art research in this area, discussing the aims, methods and conclusions drawn from a …


Finite Element Modeling And Experimental Validation Of Cooling Rates Of Large Ready-To-Eat Meat Products In Small Meat-Processing Facilities, A. Amézquita, L. Wang, Curtis L. Weller Jan 2005

Finite Element Modeling And Experimental Validation Of Cooling Rates Of Large Ready-To-Eat Meat Products In Small Meat-Processing Facilities, A. Amézquita, L. Wang, Curtis L. Weller

Department of Agricultural and Biological Systems Engineering: Faculty Publications

A two−dimensional axisymmetric transient heat conduction model was developed to simulate air chilling of large ready−to−eat meat products of ellipsoidal shape. A finite element scheme, using 1,600 linear triangular elements with 861 nodes, was implemented in Matlab 6.5 to solve the model. The model considered a variable initial temperature distribution and combined convective, radiative, and evaporative boundary conditions. Predicted values agreed well with experimental data collected in actual processing conditions. Validation of model performance resulted in maximum deviations of 2.54°C and 0.29% for temperature and weight loss histories, respectively. The maximum temperature deviation (2.54°C) occurred at the surface; however, for …


Generic, Geometric Finite Element Analysis Of The Transtibial Residual Limb And Prosthetic Socket, Barbara Silver-Thorn, Dudley S. Childress Apr 1997

Generic, Geometric Finite Element Analysis Of The Transtibial Residual Limb And Prosthetic Socket, Barbara Silver-Thorn, Dudley S. Childress

Biomedical Engineering Faculty Research and Publications

Finite element analysis was used to investigate the stress distribution between the residual limb and prosthetic socket of persons with transtibial amputation (TTA). The purpose of this study was to develop a tool to provide a quantitative estimate of prosthetic interface pressures to improve our understanding of residual limb/prosthetic socket biomechanics and prosthetic fit. FE models of the residual limb and prosthetic socket were created. In contrast to previous FE models of the prosthetic socket/residual limb system, these models were not based on the geometry of a particular individual, but instead were based on a generic, geometric approximation of the …


A Review Of Prosthetic Interface Stress Investigations, Barbara Silver-Thorn, John W. Steege, Dudley S. Childress Jul 1996

A Review Of Prosthetic Interface Stress Investigations, Barbara Silver-Thorn, John W. Steege, Dudley S. Childress

Biomedical Engineering Faculty Research and Publications

Over the last decade, numerous experimental and numerical analyses have been conducted to investigate the stress distribution between the residual limb and prosthetic socket of persons with lower limb amputation. The objectives of these analyses have been to improve our understanding of the residual limb/prosthetic socket system, to evaluate the influence of prosthetic design parameters and alignment variations on the interface stress distribution, and to evaluate prosthetic fit. The purpose of this paper is to summarize these experimental investigations and identify associated limitations. In addition, this paper presents an overview of various computer models used to investigate the residual limb …


Parametric Analysis Using The Finite Element Method To Investigate Prosthetic Interface Stresses For Persons With Trans-Tibial Amputation, Barbara Silver-Thorn, Dudley S. Childress Jul 1996

Parametric Analysis Using The Finite Element Method To Investigate Prosthetic Interface Stresses For Persons With Trans-Tibial Amputation, Barbara Silver-Thorn, Dudley S. Childress

Biomedical Engineering Faculty Research and Publications

A finite element (FE) model of the below-knee residual limb and prosthetic socket was created to investigate the effects of parameter variations on the interface stress distribution during static stance. This model was based upon geometric approximations of anthropometric residual limb geometry. The model was not specific to an individual with amputation, but could be scaled to approximate the limb of a particular subject. Parametric analyses were conducted to investigate the effects of prosthetic socket design and residual limb geometry on the residual limb/prosthetic socket interface stresses. Behavioral trends were illustrated via sensitivity analysis.

The results of the parametric analyses …