Open Access. Powered by Scholars. Published by Universities.®
Biomedical Engineering and Bioengineering Commons™
Open Access. Powered by Scholars. Published by Universities.®
Articles 61 - 78 of 78
Full-Text Articles in Biomedical Engineering and Bioengineering
Cervical Spine Biomechanical Behavior And Injury, Mbulelo T. Makola
Cervical Spine Biomechanical Behavior And Injury, Mbulelo T. Makola
Browse all Theses and Dissertations
A finite element model of the cervical spine including the C2 through C7 levels was developed in order to study the behavior of the cervical spine region. The model was validated in flexion extension, bending, and rotational load scenarios. The model was found to represent the biomechanical behavior of the cervical spine. The validated cervical spine finite element model was used to study spinal injury and disease processes. The model provided qualitative estimates of load carrying and stress distribution as well as range of motion.
A Biomechanical Comparison Of Locking Compression Plate Constructs With Plugs/Screws In Osteoporotic Bone Model, Krishna P. Desai
A Biomechanical Comparison Of Locking Compression Plate Constructs With Plugs/Screws In Osteoporotic Bone Model, Krishna P. Desai
Browse all Theses and Dissertations
Locking compression plates are proven to be safe for use in open reduction and internal fixation (ORIF) especially in osteoporotic bones. Because of various combinations of holes, the system provides more options for clinicians to use either locking screws or non-locking screws. This clinical research introduces screw like plugs which can be used along with the screws in case of locking compression plates. Experimental work was performed to determine the effectiveness of the plugs. The results showed that there is not a significant difference between the groups which used plugs and did not use the plugs, both in case of …
Population Fit Threshold: Fully Automated Signal Map Generation For Baseline Correction In Nmr-Based Metabolomics, Daniel C. Homer
Population Fit Threshold: Fully Automated Signal Map Generation For Baseline Correction In Nmr-Based Metabolomics, Daniel C. Homer
Browse all Theses and Dissertations
Baseline correction of NMR-based metabolomic spectra is a key step in data processing to elucidate biomarkers of diseased and toxic states. Automated baseline correction methods often use human-selected parameters. Presented is a method for automated baseline correction using parameters selected from and without manipulation of the spectrum. The focus is on generating an accurate signal map based on the differentiating characteristics of baseline noise and signal. The presented method of signal map generation and baseline correction was developed and tested on 13C and 1H NMR spectra. The spectra were as simple as chemical standards containing less than 25 signal peaks …
Finding Cadaveric Human Head Masses And Center Of Gravity: A Comparison Of Direct Measurement To 3d Ing, Grant Corwin Roush
Finding Cadaveric Human Head Masses And Center Of Gravity: A Comparison Of Direct Measurement To 3d Ing, Grant Corwin Roush
Browse all Theses and Dissertations
Mass properties of the human head are critical elements in developing neck injury threshold criteria in acceleration and impact environments. In order to accurately simulate the dynamics of the head in impact and acceleration environments, valid mass properties data for the human head must exist.
The purpose of this study was two-fold: First, to directly measure and generate a useful data set of human head mass properties and anthropometry, and second, compare the results from the direct measurement to measurements obtained using computed tomographic (CT) analyses of the human head. Four cadaveric human heads, all male, were measured.
For the …
Computer-Based Skeletal Age Assessment Using Hand/Wrist Radiographs In Children 8-18 Years Old, Zhihong Ni
Computer-Based Skeletal Age Assessment Using Hand/Wrist Radiographs In Children 8-18 Years Old, Zhihong Ni
Browse all Theses and Dissertations
Children's skeletons mature at different rates, and they can be affected by a variety of factors including disease, hormone imbalance or genetics. The assessment of skeletal maturity is a frequently performed procedure that allows the detection of hormonal, growth or genetic disorders. Several methods have been developed to estimate skeletal maturity. Most methods evaluate hand/wrist radiographs using indicators such as the ratios of various bone widths, the onset of the ossification of epiphysis and epiphyseal-diaphyseal fusion. Among those methods, the FELS method differs from others in the application of different grades to each indicator and the provision of a confidence …
Radio Frequency Controlled Stimulation Of Intracellular Gold Or Silver Nanoparticle Conjugates For Use As Potential Sensors Or Modulators Of Biological Function, Richard Craig Murdock
Radio Frequency Controlled Stimulation Of Intracellular Gold Or Silver Nanoparticle Conjugates For Use As Potential Sensors Or Modulators Of Biological Function, Richard Craig Murdock
Browse all Theses and Dissertations
The objective of this investigation was to further explore the ability of a radio frequency (RF) signal to interact with metal nanoparticles (NPs) for the purposes of remote stimulation or control of cellular processes. Gold and silver NPs have shown the ability to be heated by electromagnetic frequencies, especially for the purpose of deactivating abnormal cells. However, the heating of the NPs in these previous studies was constant and uncontrolled. For this study, our hypothesis was by investigating the RF heating characteristics of NPs and its impact on surface functionalizations, a remotely stimulated control mechanism can be developed at the …
Characterization And Improvement Of A Cone-Beam Ct Scanner For Quantitative Imaging, Jimish Dilip Joshi
Characterization And Improvement Of A Cone-Beam Ct Scanner For Quantitative Imaging, Jimish Dilip Joshi
Browse all Theses and Dissertations
Computed tomography (CT) has various applications in different fields. In our case, the cone-beam CT scanner is used in the industrial field for qualitative and quantitative assessment of Procter and Gamble products. The Flash CT scanner, on which we do our research, has a microfocus x-ray tube, a detector size of 30 cm x 40 cm and a rotating stage for the object to be imaged. The x-ray tube can be operated up to 225 kV. Non-linearities in the response of the detector, scatter and beam hardening may cause false interpretations of the image values. To allow appropriate assessment of …
Timing-Pulse Measurement And Detector Calibration Of The Osteoquant, Binu Eapen Enchakalody
Timing-Pulse Measurement And Detector Calibration Of The Osteoquant, Binu Eapen Enchakalody
Browse all Theses and Dissertations
The OsteoQuant is a second-generation pQCT scanner, which can provide precisedensity assessment of bone. The scanner is being upgraded with an x-ray tube radiation source and a semiconductor CZT detector. This thesis provides solutions for two issues: motion-detector timing and dead-time/beam-hardening corrections. During translation, the motion-control system of the scanner repositions the source and detector by small intervals. However, the detector collects photon counts asynchronously with respect to the motor-timing pulses and reads photon counts (frames) at regular intervals based on its own clock. Since there needs to be correspondence between source/detector location and detector readout, the first part of …
Graphical User Interface (Gui) To Study Different Reconstruction Algorithms In Computed Tomography, Shital K. Abhange
Graphical User Interface (Gui) To Study Different Reconstruction Algorithms In Computed Tomography, Shital K. Abhange
Browse all Theses and Dissertations
Computed tomography (CT) imaging relies on computational algorithms to reconstruct images from projections gathered from the CT scan. Depending on the scanner geometry, different types of reconstruction algorithms can be used. To study these different types of reconstruction algorithms in a user-friendly way, a software tool was built. The aim of the thesis was to provide a software platform to access a number of previously implemented reconstruction algorithms with ease and minimal knowledge of the reconstruction code. The goal was accomplished by building a Graphical User Interface (GUI) using MATLAB 7.7.0 (R2008b). In addition to creating mathematical objects and invoking …
Performance Analysis Of Quantitative Bone Measurement With Spiral, Multi-Detector Ct Scanners, Shruti Gupta
Performance Analysis Of Quantitative Bone Measurement With Spiral, Multi-Detector Ct Scanners, Shruti Gupta
Browse all Theses and Dissertations
The measure of bone strength and fracture risk assessment is based primarily on bone mineral density (BMD). Computed tomography (CT), a frequently used radiographic technique that provides cross-sectional images, can be used for BMD quantification. Called quantitative computed tomography (QCT), it determines true volumetric density and also differentiates between trabecular and cortical bone. As a result, QCT improves the ability to detect early changes in trabecular BMD accurately and precisely.
The introduction of helical CT for quantitative analysis introduces new complexities. Even though using multi-detector helical CT for BMD assessment is being suggested, a detailed analysis of its validity is …
Histogram-Based Template Matching Object Detection In Images With Varying Brightness And Contrast, Christina Da-Wann Schrider
Histogram-Based Template Matching Object Detection In Images With Varying Brightness And Contrast, Christina Da-Wann Schrider
Browse all Theses and Dissertations
Our challenge was to develop a semi-automatic target detection algorithm to aid human operators in locating potential targets within images. In contrast to currently available methods, our approach is relatively insensitive to image brightness, image contrast and object orientation. Working on overlapping image blocks, we used a sliding difference method of histogram matching. Incrementally sliding the histograms of the known object template and the image region of interest (ROI) together, the sum of absolute histogram differences was calculated. The minimum of the resultant array was stored in the corresponding spatial position of a response surface matrix. Local minima of the …
Biomechanical Evaluation Of Locked And Non-Locked Constructs Under Axial And Torsion Loading, Vinit A. Patel
Biomechanical Evaluation Of Locked And Non-Locked Constructs Under Axial And Torsion Loading, Vinit A. Patel
Browse all Theses and Dissertations
Locking compression plates are proven to be safe for use in open reduction and internal fixation (ORIF). The ORIF is a procedure performed to treat fractures. It has various combination of holes, the system provides more options for clinicians to use either locking screw or non-locking screws. This thesis investigates and determines the best construct with special locking and non-locking screws under both axial and torsion loading. Twenty femur constructs were assembled with 2 cm osteotomy gap between femur shaft and condyle, bridged with 4.5 mm - 10 holes condyle plates. Femurs were divided in to 4 groups according to …
Motion-Control System Of Bench-Top Ct Scanner, Tarpit Kaushikbhai Patel
Motion-Control System Of Bench-Top Ct Scanner, Tarpit Kaushikbhai Patel
Browse all Theses and Dissertations
Computed Tomography (CT) imaging has found applications in many areas such as diagnostic visualization, quantitative estimation, and therapeutic verification. In this wide range of applications, a CT scanner that can provide the data collection schemes of both second- and third-generation data-collection geometries will be an asset for laboratory research. In this thesis project, we developed a mechanical design and constructed a dual-generation CT scanner that provides flexibility in accommodating a wide range of object sizes with minimum scan time. Using 3-D graphical design software, models of the current second-generation CT scanner and possible solutions for modification were simulated. Based on …
Finite Element Optimization Of Hip Implant Geometrical Parameters To Determine Safe Zones And Resist Dislocation, Himanshu K. Bhatt
Finite Element Optimization Of Hip Implant Geometrical Parameters To Determine Safe Zones And Resist Dislocation, Himanshu K. Bhatt
Browse all Theses and Dissertations
A computational study was performed using finite element analysis (FEA) of three dimensional solid hip implant models. Twelve different hip implant models were designed to investigate the performance of geometrical parameters affecting hip stability. The parameters examined were head diameter, neck diameter, head-to-neck ratio, neck angle and acetabular liner thickness. Component orientations included cup anatomical inclination and cup anteversion, which should be accounted for during total hip implant design as well as in the practice of arthroplasties. A static analysis was performed for all 12 hip designs using stainless steel 316L. von Mises stress, contact stress, contact penetration, and sliding …
Automated Analysis Of Metacarpal Cortical Thickness In Serial Hand Radiographs, Aarti Raheja
Automated Analysis Of Metacarpal Cortical Thickness In Serial Hand Radiographs, Aarti Raheja
Browse all Theses and Dissertations
To understand the roles of various genes that influence skeletal bone accumulation and loss, accurate measurement of bone mineralization is needed. However, it is a challenging task to accurately assess bone growth over a person's lifetime. Traditionally, manual analysis of hand radiographs has been used to quantify bone growth, but these measurements are tedious and may be impractical for a large-scale growth study. The aim of this project was to develop a tool to automate the measurement of metacarpal cortical bone thickness in standard hand-wrist radiographs of humans aged 3 months to 70+ years that would be more accurate, precise …
Optimal Eeg Channels And Rhythm Selection For Task Classification, Vikramvarun Kannan Adikarapatti
Optimal Eeg Channels And Rhythm Selection For Task Classification, Vikramvarun Kannan Adikarapatti
Browse all Theses and Dissertations
The Primary Objective of this research is to implement an automatic method for selecting the most optimal EEG channels for task classification purposes. The secondary objective of this research is to choose the most optimal EEG rhythm from which the optimal EEG channels would be selected automatically. The automatic selection of the optimal channels is enabled by implementing the Common Spatial Patterns algorithm (CSP). Common spatial analysis is performed on the data recorded. By choosing the channels with high spatial pattern values the optimal channels are chosen. The optimal frequency bands are chosen by splitting the data from a single …
Fabrication And Testing Of Scaffolds For Cell Growth From Ionic Liquid Solubilized Fibroin, Maneesh Kumar Gupta
Fabrication And Testing Of Scaffolds For Cell Growth From Ionic Liquid Solubilized Fibroin, Maneesh Kumar Gupta
Browse all Theses and Dissertations
The advent of tissue engineering has spurred research into developing materials to act as scaffolds for tissue growth. These scaffolds require materials capable of mimicking the in vivo conditions so that tissues can be grown effectively in vitro. Silk is an attractive biomaterial for use in tissue engineering applications because of its slow degradation, excellent mechanical properties, and biocompatibility. The major objective of the research in this thesis is to demonstrate a simple method to cast films directly from silk fibroin dissolved in an ionic liquid. The films cast from the silk ionic liquid solution were found to support normal …
Methodology For Quantifying Biomechanical Bone Movement Of Transtibial Amputations, Johanna C. Bell
Methodology For Quantifying Biomechanical Bone Movement Of Transtibial Amputations, Johanna C. Bell
Browse all Theses and Dissertations
A controversy has long existed about an alternate below knee amputation procedure that may be more beneficial than the traditional transtibial amputation. The proponents of this alternate procedure that stabilizes the distal tibia and fibula claim it reduces excessive movement of the fibula relative to the tibia that occurs with common movements, such as walking. The purpose of this study is to develop a methodology for quantifying excessive movement of the fibula bone relative to the tibia bone in traditional below the knee amputations. The methodology will measure the movement and rotation of the fibula relative to the tibia. These …