Revision Total Hip Femoral Stem Micromotion And Statistical Shape Modeling Of The Knee, William Fugit Jan 2022

Revision Total Hip Femoral Stem Micromotion And Statistical Shape Modeling Of The Knee, William Fugit

Electronic Theses and Dissertations

The first purpose of this thesis was to compare the amount of micromotion seen in the femoral stem in a revision total hip arthroplasty between simple loading conditions and loading conditions derived from activities of daily living, through the use of experimental and computational methods. The amount of micromotion at the bone-implant interface was larger for activities of daily living, with ranges of 200μm more than the largest simple loading conditions. The second purpose of this thesis was to compare measurements of accuracy in a statistical shape model between individual bone and joint-level models, specifically for the knee. Using computational …


An Investigation Into The Plate Fixation For Periprosthetic Femoral Fractures, Xiang Chen Jan 2022

An Investigation Into The Plate Fixation For Periprosthetic Femoral Fractures, Xiang Chen

Electronic Theses and Dissertations

Periprosthetic femoral fractures are the third most reason for reoperation after the total hip arthroplasty with an incident rate of approximately 6%. The Vancouver type B periprosthetic femoral fractures account for over 70% of all cases, while the sub-type B1 fracture (when the total hip stem is stable) has remained a clinical challenge due to incidences of severe complications after the standard plate-screw fixation. To seek biomechanically sound fixations for the Vancouver type B1 fracture, this dissertation developed a combined modeling and testing framework to investigate the efficacy of fixation for a Vancouver type B1 fracture using different construct lengths …


Contact Simulation For Evaluating Patient Specific Surgical Guide Stability, Vincent Nierste Jan 2022

Contact Simulation For Evaluating Patient Specific Surgical Guide Stability, Vincent Nierste

Electronic Theses and Dissertations

This study proposes a novel computational method to quantify guide stability for Patient Specific Instrumentation (PSI) guides. A finite element contact model was used to analyze the final position of PSI guides on a femur across a range of loading parameters representing forces applied by a surgeon during operative use. Separate segmentation methods were used for the guide and bone geometry to represent differences between segmentation and actual patient geometry. The region of loading parameters over which the guide exhibited a consistent final position was measured and reported as Guide Stability Score. The model was verified using cadaver specimens for …


Correlating With Local Variation In Collagen Level And Mechanical Properties Of The Heart Tissues, Talayeh Tavangar Jan 2021

Correlating With Local Variation In Collagen Level And Mechanical Properties Of The Heart Tissues, Talayeh Tavangar

Electronic Theses and Dissertations

The determination of the myocardium's tissue properties is essential in constructing finite element (FE) models of the heart. To obtain accurate results, especially for functionally modeling the heart, we must determine the tissue properties in-vivo. The calculation of the heart tissue properties remains a challenging area as it is categorized as a heterogeneous, anisotropic, nonlinear soft tissue that undergoes large deformation. In this work, we tried to introduce and evaluated a finite element method to determine the mechanical properties of the cardiac tissue. The introduced method combined a finite element modeling with the experimentally obtained images from the left and …


Accurate Measurement Of Healthy Joint Kinematics To Inform Diagnosis And Treatment, Vasiliki Kefala Jan 2021

Accurate Measurement Of Healthy Joint Kinematics To Inform Diagnosis And Treatment, Vasiliki Kefala

Electronic Theses and Dissertations

The description of human motion has a primary importance in different scientific areas such as medicine, sports, physical therapy. Kinematics specifically studies pure motion without reference to the causes of motion such as forces. Understanding the kinematics of human movement is of critical importance in medicine and biology. Motion measure­ment can be used in order to to evaluate functional performance of limbs under normal and abnormal conditions. Kinematic knowledge is also important for diagnosis and surgi­cal treatment of joint disease and the design of implants to rehabilitate function. Accurate joint kinematics is essential to protect articular functionality. An alteration may …


An Accuracy And Precision Analysis Of The Velys™ Robotic Assisted Solution For Total Knee Arthroplasty, Gary Doan Jan 2021

An Accuracy And Precision Analysis Of The Velys™ Robotic Assisted Solution For Total Knee Arthroplasty, Gary Doan

Electronic Theses and Dissertations

Total knee arthroplasty (TKA) is a procedure where the arthritic surfaces of the knee is removed and replaced with a combination of metal and polymer implants that recreates the joint line to restore function and quality of life. Implant alignment is important in the success of a TKA. Modern day conventional instrumentation can be cumbersome in the operating room and can be inaccurate when resecting bone and aligning implants. Patients with large errors in resections and implant orientation are more prone to experience mechanical failures with their TKA. Mechanical failures in primary TKA require revision surgeries which can lead to …


Dislocation Mechanics Of Total Hip Arthroplasty: A Combined Experimental And Computational Analysis, Michael Scinto Jan 2021

Dislocation Mechanics Of Total Hip Arthroplasty: A Combined Experimental And Computational Analysis, Michael Scinto

Electronic Theses and Dissertations

While total hip arthroplasty is considered a successful procedure, dislocation remains a serious complication as recurrent dislocations may require additional surgeries. Knowledge on dislocation events as they occur in vivo are limited, therefore researchers rely on experimental and computational methods. A custom MATLAB script and an experimental procedure utilizing a six-degree of freedom actuator were developed to further understand how various surgical considerations affect dislocation mechanics in total hip arthroplasty. Computationally, it was determined that impingement free range of motion is limited during internal rotation in flexion and during external rotation in extension. Experimentally, our results suggest that the posterior …


Tibial Strains And Tray-Bone Micromotions After Total Knee Arthroplasty: Computational Studies Evaluating The Tibial Fixation, Huizhou Yang Jan 2021

Tibial Strains And Tray-Bone Micromotions After Total Knee Arthroplasty: Computational Studies Evaluating The Tibial Fixation, Huizhou Yang

Electronic Theses and Dissertations

Cemented and cementless fixation in total knee arthroplasty (TKA) have been successfully used for decades. As the number of younger and more active patients treated with TKA continues to increase, long-term implant survivorship is of increasing importance. One of the most common complications and hence the reason for revision is mechanical loosening (23.1% of all revised TKA). The loosening mechanisms have been proposed for different fixation types. For cemented fixation, bone remodeling after surgery is regulated by the changes in strain energy density (SED). The recruitment of osteoclasts and osteoblasts is controlled by SED-related signals. Insufficient stimuli can promote bone …


Fluid Dynamics Characterization Of Transcatheter Aortic Valves, Mohammed Barakat Jan 2020

Fluid Dynamics Characterization Of Transcatheter Aortic Valves, Mohammed Barakat

Electronic Theses and Dissertations

Aortic stenosis due to degenerative calcific aortic valvular disease is the most reason for aortic valve replacement in developed countries. Aortic stenosis affects up to 7% of the world population, and current clinical data indicate that the number of the affected people could be triple by 2050, due to population ageing and health lifestyle. Transcatheter aortic valve replacement (TAVR) was introduced as a minimal invasive treatment of severe aortic stenosis. Even though surgical aortic valve replacement (SAVR) is considered the golden standard treatment for severe aortic stenosis patients, TAVR showed equivalent or even superior outcome compare to SAVR. Currently, transcatheter …


Developing Machine Learning Algorithms For Behavior Recognition From Deep Brain Signals, Hosein Golshan Mojdehi Jan 2020

Developing Machine Learning Algorithms For Behavior Recognition From Deep Brain Signals, Hosein Golshan Mojdehi

Electronic Theses and Dissertations

Parkinson’s disease (PD) is a neurodegenerative condition and movement disorder that appears with symptoms such as tremor, rigidity of muscles and slowness of movements. Deep brain stimulation (DBS) is an FDA-approved surgical therapy for essential tremor and PD. Despite the fact that DBS substantially alleviates the motor signs of PD, it can cause cognitive side effects and speech malfunction mainly due to the lack of adaptivity and optimality of the stimulation signal to the patients’ current state. A behavior-adapted closed-loop DBS system may reduce the side effects and power consumption by adjusting the stimulation parameters to patients’ need.

Behavior recognition …


Transcatheter Mitral Valve Replacement: Structural And Hemodynamic Analysis, Saba Ravaghi Jan 2020

Transcatheter Mitral Valve Replacement: Structural And Hemodynamic Analysis, Saba Ravaghi

Electronic Theses and Dissertations

Transcatheter mitral valve replacement (TMVR) is being developed to become a substitute therapy for surgery in prohibitive or high surgical risk patients to treat severe mitral regurgitation. A limited number of TMVR systems are under clinical evaluation. However, transcatheter mitral valve (TMV) long-term durability and hemodynamic performance is not known. TMV durability and hemodynamics must match with that of surgical bioprostheses for potential commercialization of TMVR. Experimental and computational approaches were used to find the leaflets’ three-dimensional anisotropic mechanical properties in a transcatheter Edwards SAPIEN 3 valve and a surgical Carpentier-Edwards PERIMOUNT Magna mitral valve and finite element (FE) simulations …


In Vivo Data Capture Using Hssr For Calibration Of Computational Models, Thor Erik Andreassen Jan 2020

In Vivo Data Capture Using Hssr For Calibration Of Computational Models, Thor Erik Andreassen

Electronic Theses and Dissertations

Computational modeling is a vital tool for understanding and evaluating healthy and unhealthy function of the musculoskeletal aspects of the human body. However, the accuracy of the musculoskeletal models depends significantly on the accuracy of the input data used to calibrate various behavioral parameters of the model. To date, most computational models have been built using generic in vitro data, mostly because of a lack of accurate and meaningful datasets from in vivo testing. The next major step in computational modeling is to create subject-specific computational models using calibration data taken from in vivo testing. The overall goal was to …


Development Of A Clinical Marker-Less Motion Capture System For Patient Monitoring, Abigail Eustace Jan 2020

Development Of A Clinical Marker-Less Motion Capture System For Patient Monitoring, Abigail Eustace

Electronic Theses and Dissertations

The ability to understand human movement is beneficial for deciding surgical procedures, tracking disease progression over time and helping with patient rehabilitation. The current gold-standard for collecting human movement is the use of 3-dimensional marker-based systems. Several studies have presented the many limitations to the current gold-standard that reduces the number of people who are able to benefit from a gait analysis. Those limitations in the current gold-standard include the requirements of large laboratory space, costly equipment, long instrumentation and collection time, and the potential for motion artifact from markers being placed on the skin. The purpose of this study …


The Effects And Analysis Of Implant Type And Surgical Approach In Total Hip Arthroplasty Dislocation Resistance, Brittany Marshall Jan 2020

The Effects And Analysis Of Implant Type And Surgical Approach In Total Hip Arthroplasty Dislocation Resistance, Brittany Marshall

Electronic Theses and Dissertations

Total hip arthroplasty (THA) is one of the most successful orthopaedic surgeries performed, in which the hip joint is reconstructed to decrease pain and to improve the functionality to the joint. Although these surgeries are very successful, there still remain areas for improvement, such as failures due to instability and dislocation of the implanted joint. The purpose of this thesis is to investigate the effect of surgical entrance approach on dislocation, the effect of implant type, and the effect of capsule repair and closure. The need to quantify the resistance to dislocation is important in understanding the effect that each …


A Longitudinal Examination Of Biomechanical Balance And Quantitative Multidomain Assessments During Recovery Following Sport-Related Concussion, Moira Kate Pyrhoda Jan 2020

A Longitudinal Examination Of Biomechanical Balance And Quantitative Multidomain Assessments During Recovery Following Sport-Related Concussion, Moira Kate Pyrhoda

Electronic Theses and Dissertations

Sport-related concussion is an inherent risk to athlete health in contact and collision sports. Both short- and long-term risks are associated with the injury. Short-term, athletes may develop post-concussion syndrome (PCS), the persistence of cognitive, physical, and emotional symptoms for weeks or months after injury. Athletes who return to play (RTP) prematurely are at increased risk for lower extremity injury and repeated concussion injuries. Long-term, history of multiple concussions have been linked to neurodegenerative diseases. Due to these risks, concussion assessments must be sensitive to the injury and useful in the diagnosis, recovery, and RTP phases of the injury.

Sideline …


Effects On Initial Fixation Of Cementless Tibial Trays In Total Knee Arthroplasty, Brooke Fritts Thompson Jan 2020

Effects On Initial Fixation Of Cementless Tibial Trays In Total Knee Arthroplasty, Brooke Fritts Thompson

Electronic Theses and Dissertations

Bone mineral density (BMD), among other factors, largely effect the initial stability of the cementless tibial tray component in a total knee replacement (TKR), where increased motion at the tray-bone interface hinders bony ingrowth. With a lack of bony ingrowth, the cementless implant will not experience long-term success. Understanding which factors influence initial stability yields insight into surgical technique considerations and help inform a surgeon’s implant choice. The objective of this study was to evaluate factors influencing the initial stability of cementless tibial trays using a 6-degree of freedom (6-DOF) robotic joint simulator, the AMTI VIVO, and combined loading scenarios …


The Relative Contribution Of Fixation Features, Activity, And Tibiofemoral Conformity On Initial Stability Of Cementless Tibial Trays, James Sullivan Deacy Jan 2019

The Relative Contribution Of Fixation Features, Activity, And Tibiofemoral Conformity On Initial Stability Of Cementless Tibial Trays, James Sullivan Deacy

Electronic Theses and Dissertations

Initial stability of cementless total knee replacements (TKR) is critical to implant success as excessive motion between the bone and implant prevents bony ingrowth that is critical to the long-term survivability of cementless implants. Prior studies have shown that excessive micromotion causes fibrous tissue growth instead of beneficial bony growth. There are many factors that influence initial stability including the design of the tibial tray and the tibiofemoral articulations. Understanding the impacts of these design features on micromotion between the bone and implants is crucial to improving the performance of cementless TKR. Prior studies only tested for the effect of …


Laxity Of The Hip Capsule In Natural And Posteriorly Implanted Specimens, Luke Storer Jan 2019

Laxity Of The Hip Capsule In Natural And Posteriorly Implanted Specimens, Luke Storer

Electronic Theses and Dissertations

The hip capsule consists of ligament tissue that surrounds the hip joint, providing stability to ensure proper alignment, prevent dislocation, and facilitate proper joint function. The objective of this study was to characterize the torque-rotation response of the natural and posteriorly implanted hip capsule in healthy cadaveric specimens in multiple degrees-of-freedom (DOF) and under combined loading scenarios using the AMTI VIVO, a robotic joint simulator. The anterior portion of the hip capsule was stained with Methylene Blue and virtual extensometers were calculated by Digital Image Correlation (DIC) software for Finite Element Analysis (FEA) model validation. The range of motion (ROM) …


Predictive Modeling Of Hip Dislocation: Assessment Of Surgical And Patient Factors To Reduce The Occurrence Of Hip Instability And Adverse Clinical Outcomes, Daniel N. Huff Jan 2018

Predictive Modeling Of Hip Dislocation: Assessment Of Surgical And Patient Factors To Reduce The Occurrence Of Hip Instability And Adverse Clinical Outcomes, Daniel N. Huff

Electronic Theses and Dissertations

Instability and dislocation remain leading indications for revision of primary Total Hip Arthroplasty (THA). Many studies have addressed the links between implant design and propensity for dislocation, however a comprehensive review of the ability of modern THA constructs to protect against joint instability is needed.

Accordingly, the objective of this study is to provide objective data about THA risks to be considered in the treatment algorithm to protect against adverse joint loading conditions and joint instability. Adverse loading conditions were assessed in a population of activities of daily living using data from telemetric hip implant representation in an FE simulation …


Cementless Tibial Base Micromotion During Activities Of Daily Living, Hayden Wilson Jan 2018

Cementless Tibial Base Micromotion During Activities Of Daily Living, Hayden Wilson

Electronic Theses and Dissertations

Initial stability of cementless total knee replacement (TKR) components is directly related to long-term fixation and success, as excess motion hinders bony ingrowth. To assess implant stability, there is a need for more physiologically accurate loading conditions, incorporating forces and displacements in all 6 degrees-of-freedom found in the knee joint, as well as understanding the impact of femoral flexion on conformity of tibiofemoral articulation. Understanding how different activities of daily living generate tibial micromotion yields insight into surgical technique considerations, and rehabilitation strategies post-operatively. ASTM F3141-15, which specifies knee flexion, Internal-External moment, Medial-Lateral, Anterior-Posterior and Superior-Inferior forces during gait and …


Computational Modeling Of Transcatheter Aortic Valves, Mostafa Abbasi Jan 2018

Computational Modeling Of Transcatheter Aortic Valves, Mostafa Abbasi

Electronic Theses and Dissertations

Transcatheter aortic valve replacement (TAVR) is an established therapy alternative to surgical valve replacement in high-risk and intermediate-risk patients with severe aortic stenosis. Currently, although TAVR is an alternative and less-invasive treatment for high-risk and intermediate-risk patients, surgical aortic valves replacement (SAVR) was still considered as the gold standard for low-risk patients. TAVR could potentially be applied to lower-risk younger patients if the indications can be safely expanded to the patients and transcatheter aortic valve (TAV) long-term durability can match with that of surgical bioprostheses. In contrast to surgical aortic valves (SAVs), there have been limited clinical data on the …


Computer-Aided Cancer Diagnosis And Grading Via Sparse Directional Image Representations, Hadi Rezaeilouyeh Jan 2017

Computer-Aided Cancer Diagnosis And Grading Via Sparse Directional Image Representations, Hadi Rezaeilouyeh

Electronic Theses and Dissertations

Prostate cancer and breast cancer are the second cause of death among cancers in males and females, respectively. If not diagnosed, prostate and breast cancers can spread and metastasize to other organs and bones and make it impossible for treatment. Hence, early diagnosis of cancer is vital for patient survival. Histopathological evaluation of the tissue is used for cancer diagnosis. The tissue is taken during biopsies and stained using hematoxylin and eosin (H&E) stain. Then a pathologist looks for abnormal changes in the tissue to diagnose and grade the cancer. This process can be time-consuming and subjective. A reliable and …


Mechanical Effects Of Surgical Adhesives On Ascending Thoracic Aortic Aneurysm Replacement, Dong Qiu Jan 2017

Mechanical Effects Of Surgical Adhesives On Ascending Thoracic Aortic Aneurysm Replacement, Dong Qiu

Electronic Theses and Dissertations

Ascending thoracic aortic aneurysm (aTAA) is a potentially lethal disease which grows gradually over time and may lead to aortic dissection and rupture. Currently, aTAA surgical repair using Dacron graft is a well-established treatment. In addition, surgical adhesives are frequently used in the surgeries to seal the anastomotic site. This study aims to investigate mechanical effects of four commonly used surgical adhesives, namely BioGlue, CoSeal, Crosseal, and Tisseel, on the suture site using in-vitro digital image correlation (DIC) method and finite element (FE) simulations in an ovine model. In this study, first, mechanical properties of ovine ascending aorta were obtained …


3d Bioprinting Hydrogel For Tissue Engineering An Ascending Aortic Scaffold, Benjamin Stewart Jan 2017

3d Bioprinting Hydrogel For Tissue Engineering An Ascending Aortic Scaffold, Benjamin Stewart

Electronic Theses and Dissertations

The gold standard in 2016 for thoracic aortic grafts is Dacron®, polyethylene terephthalate, due to the durability over time, the low immune response elicited and the propensity for endothelialization of the graft lumen over time. These synthetic grafts provide reliable materials that show remarkable long term patency. Despite the acceptable performance of Dacron® grafts, it is noted that autographs still outperform other types of vascular grafts when available due to recognition of the host's cells and adaptive mechanical properties of a living graft. 3-D bioprinting patient-specific scaffolds for tissue engineering (TE) brings the benefits of non-degrading synthetic …


Segmental Movement Compensations In Patients With Transtibial Amputation Identified Using Angular Momentum Separation, Brecca M. M. Gaffney Jan 2017

Segmental Movement Compensations In Patients With Transtibial Amputation Identified Using Angular Momentum Separation, Brecca M. M. Gaffney

Electronic Theses and Dissertations

Patients with unilateral dysvascular transtibial amputation (TTA) adopt movement compensations that are required to maintain balance and achieve ambulation in the absence of ankle plantar flexion, and result in increased and asymmetric joint loading patterns. As a result, this population is at an increased risk of overuse injuries, such as low back pain (LBP). Clinical gait analysis is used to guide diagnostics in movement retraining following amputation, and is performed using instrumented (research based) or observational analyses (clinically based). However, instrumented analyses are currently impractical in most clinical settings due to expense and computational limitations. This dissertation presents the use …


Statistical Shape Modeling To Quantify Variation In The Proximal Humeral Anatomy, Paul B. Sade Sr. Jan 2017

Statistical Shape Modeling To Quantify Variation In The Proximal Humeral Anatomy, Paul B. Sade Sr.

Electronic Theses and Dissertations

The fit of the humeral prosthesis to the intramedullary canal and the replication of the anatomic humeral head center are important factors in Total Shoulder Arthroplasty (TSA). The objective of this thesis was to develop a Statistical Shape Model (SSM) of the cortical and cancellous bone regions of the proximal humerus, and to assess potential shape differences with gender and ethnicity, with a goal of informing implant design. An SSM was used and Principal Component Analysis (PCA) was applied to data that represented both the cancellous and cortical humeral bone of 63 healthy subjects and cadavers. Anatomical measurements and PC …


Six Degrees Of Freedom: Kinematics Of The Healthy Ankle Syndesmosis Joint, Veronica A. Hogg-Cornejo Jan 2017

Six Degrees Of Freedom: Kinematics Of The Healthy Ankle Syndesmosis Joint, Veronica A. Hogg-Cornejo

Electronic Theses and Dissertations

Syndesmotic injury, more commonly known as a "high ankle sprain", accounts for over 12% of all ankle sprain incidents in the US; of which, over 25% occur during a sporting activity. Typically, harm to the syndesmosis occurs in sports such as football, soccer, lacrosse, and hockey where it is common for an athlete to experience rapid and extreme dorsiflexion-external rotations of the foot. Severe syndesmotic sprains have been noted by clinicians as the most difficult ankle injury to accurately diagnose and treat, require the most recuperation time, and often results in life-long dysfunction. Even more problematic, 40% of patients suffering …


Specimen-Specific Natural, Pathological, And Implanted Knee Mechanics Using Finite Element Modeling, Azhar Akber Ali Jan 2017

Specimen-Specific Natural, Pathological, And Implanted Knee Mechanics Using Finite Element Modeling, Azhar Akber Ali

Electronic Theses and Dissertations

There is an increasing incidence of knee pain and injury among the population, and increasing demand for higher knee function in total knee replacement designs. As a result, clinicians and implant manufacturers are interested in improving patient outcomes, and evaluation of knee mechanics is essential for better diagnosis and repair of knee pathologies. Common knee pathologies include osteoarthritis (degradation of the articulating surfaces), patellofemoral pain, and cruciate ligament injury and/or rupture. The complex behavior of knee motion presents unique challenges in the diagnosis of knee pathology and restoration of healthy knee function. Quantifying knee mechanics is essential for developing successful …


Statistical Shape And Intensity Modeling Of The Shoulder, Irene Sintini Jan 2017

Statistical Shape And Intensity Modeling Of The Shoulder, Irene Sintini

Electronic Theses and Dissertations

Anatomical variability in the shoulder is inherently present and can influence healthy and pathologic biomechanics and ultimately clinical decision-making. Characterizing variation in bony morphology and material properties in the population can support treatment and specifically the design, via shape and sizing, of shoulder implants. Total Shoulder Arthroplasty (TSA) is the treatment of choice for glenohumeral osteoarthritis as well as bone fracture. Complications and poor outcomes in TSA are generally influenced by the inability of the implant to replicate the natural joint biomechanics and by the bone quality around the fixation features. For this reason, knowledge of bony morphology and mechanical …


Cost-Effective Prosthetic Hand Controlled By Emg, Mohammad Yahya Almuhanna Jan 2016

Cost-Effective Prosthetic Hand Controlled By Emg, Mohammad Yahya Almuhanna

Electronic Theses and Dissertations

A cost-effective five-finger prosthetic hand is designed from aluminum, modeled and controlled using surface Electromyography (EMG) signals, which are obtained from the human body. Force sensors are used to control required forces needed to grasp and pick objects. A prototype hand is developed and it is experimentally tested to reproduce a wide spectrum of human hand motions. The size of the five-finger hand is similar to an adult male human hand, and it is capable of reproducing most of movements. Each finger has the same number of links as the real/human hand. Each finger also has a force sensor used …