Open Access. Powered by Scholars. Published by Universities.®
Biomedical Engineering and Bioengineering Commons™
Open Access. Powered by Scholars. Published by Universities.®
- Discipline
-
- Medicine and Health Sciences (83)
- Life Sciences (74)
- Biomedical Devices and Instrumentation (69)
- Biological Engineering (49)
- Electrical and Computer Engineering (46)
-
- Bioimaging and Biomedical Optics (41)
- Biomaterials (35)
- Mechanical Engineering (35)
- Chemical Engineering (33)
- Medical Specialties (32)
- Molecular, Cellular, and Tissue Engineering (31)
- Physical Sciences and Mathematics (31)
- Biomechanics and Biotransport (29)
- Other Biomedical Engineering and Bioengineering (27)
- Bioelectrical and Neuroengineering (24)
- Biomedical (24)
- Nanoscience and Nanotechnology (21)
- Biochemical and Biomolecular Engineering (18)
- Biochemistry, Biophysics, and Structural Biology (18)
- Medical Sciences (18)
- Biology (16)
- Materials Science and Engineering (15)
- Biomechanical Engineering (13)
- Analytical, Diagnostic and Therapeutic Techniques and Equipment (12)
- Cell and Developmental Biology (12)
- Diseases (12)
- Biotechnology (9)
- Cardiology (9)
- Institution
-
- Engineering Conferences International (245)
- Marquette University (52)
- Purdue University (50)
- Virginia Commonwealth University (36)
- University of Arkansas, Fayetteville (32)
-
- University of Nebraska - Lincoln (30)
- Utah State University (30)
- University of Kentucky (27)
- Wright State University (27)
- Old Dominion University (26)
- California Polytechnic State University, San Luis Obispo (22)
- University of South Florida (21)
- University of Texas at Arlington (20)
- City University of New York (CUNY) (18)
- New Jersey Institute of Technology (16)
- Missouri University of Science and Technology (13)
- Wayne State University (13)
- Florida Institute of Technology (12)
- Michigan Technological University (12)
- Santa Clara University (12)
- Louisiana Tech University (10)
- University of Louisville (10)
- University of Denver (8)
- University of South Carolina (7)
- Clemson University (6)
- Technological University Dublin (6)
- The University of Akron (6)
- Boise State University (5)
- Edith Cowan University (5)
- Himmelfarb Health Sciences Library, The George Washington University (5)
- Keyword
-
- Applied sciences (35)
- Biomedical engineering (19)
- CHO (19)
- Biological sciences (13)
- Biomedical Sciences (11)
-
- Perfusion (11)
- CHO cells (9)
- Department of Biomedical, Industrial & Human Factors Engineering (9)
- Product quality (9)
- Cancer (8)
- Microfluidics (8)
- Scale-down (8)
- Biomaterials (7)
- Daniel Felix Ritchie School of Engineering and Computer Science (7)
- Glycosylation (7)
- Health and environmental sciences (7)
- Imaging (7)
- Nanoparticles (7)
- Retina (7)
- Scale-up (7)
- Transcriptomics (7)
- Bioengineering (6)
- Biomedical Engineering (6)
- Faculty (6)
- Machine learning (6)
- Metabolism (6)
- Rehabilitation (6)
- Biomechanics (5)
- Fed-batch (5)
- High-throughput (5)
- Publication
-
- Cell Culture Engineering XV (245)
- Biomedical Engineering Faculty Research and Publications (42)
- Theses and Dissertations (28)
- The Summer Undergraduate Research Fellowship (SURF) Symposium (22)
- Browse all Theses and Dissertations (20)
-
- USF Tampa Graduate Theses and Dissertations (19)
- Biomedical Engineering Undergraduate Honors Theses (18)
- Electronic Theses and Dissertations (17)
- Capstone Design Expo Posters (14)
- Open Access Dissertations (14)
- Doctoral Dissertations (12)
- Master's Theses (12)
- Bioelectrics Publications (11)
- Chemical and Biochemical Engineering Faculty Research & Creative Works (10)
- College of Engineering News (10)
- Publications and Research (10)
- Theses (10)
- UCARE: Research Products (10)
- Bioengineering Senior Theses (9)
- Wayne State University Dissertations (9)
- Bioengineering Dissertations - Archive (8)
- Biological Engineering Faculty Publications (7)
- Biomedical, Industrial & Human Factors Engineering Faculty Publications (7)
- Dissertations (7)
- Graduate Theses and Dissertations (7)
- Theses and Dissertations--Biomedical Engineering (7)
- Articles (6)
- Bioengineering Faculty Publications - Archive (6)
- Bioengineering Theses - Archive (6)
- Biomedical Engineering (6)
- Publication Type
Articles 841 - 857 of 857
Full-Text Articles in Biomedical Engineering and Bioengineering
Bioactivity/Cytotoxicity Of Micro-/Nano-Materials And Novel Development Of Fiber-Optic Probes For Single Cell Monitoring, Qingbo Yang
Doctoral Dissertations
"Manufactured nano-/micro-materials (MNMs) have been widely used and their interactions with niche biological environment are highly concerned for both of their biohazardous and bioactive effects, whereas no available comprehensive evaluations or regulations have been provided yet. This dissertation thus focuses on three major aspects: 1) fundamental toxicity understandings of a typical MNMs (zinc oxide nanoparticles), 2) bioactivity evaluations of representative bioactive MNMs, and 3) development of novel micro-probes for high spatial resolution monitoring. Firstly, the NP's concentration, irradiation, hydrodynamic size, and the localized pH, ionic strength, NP zeta-potential as well as dissolved oxygen levels were found correlated with the production …
Detecting, Segmenting And Tracking Bio-Medical Objects, Mingzhong Li
Detecting, Segmenting And Tracking Bio-Medical Objects, Mingzhong Li
Doctoral Dissertations
"Studying the behavior patterns of biomedical objects helps scientists understand the underlying mechanisms. With computer vision techniques, automated monitoring can be implemented for efficient and effective analysis in biomedical studies. Promising applications have been carried out in various research topics, including insect group monitoring, malignant cell detection and segmentation, human organ segmentation and nano-particle tracking.
In general, applications of computer vision techniques in monitoring biomedical objects include the following stages: detection, segmentation and tracking. Challenges in each stage will potentially lead to unsatisfactory results of automated monitoring. These challenges include different foreground-background contrast, fast motion blur, clutter, object overlap and …
Biodegradable Electronic And Optical Devices Toward Temporary Implants, Md Shihab Adnan
Biodegradable Electronic And Optical Devices Toward Temporary Implants, Md Shihab Adnan
Masters Theses
"Implantable biomedical devices have a high potential to revolutionize health care technologies in near future. Implantable devices can be classified as permanent prosthetic devices such as pacemakers or nerve stimulants and temporary devices for intermediate monitoring and control scenario which are still in research phase. In contrast to permanent device, temporary implants lose functionality and become unnecessary after intended operational lifetime which may pose serious electromagnetic and biomedical safety concern, latent complications at the implanted sites and possible ethical issues if not removed from body by an additional surgical operation.
The first paper of this thesis focuses on exploring the …
Severity Of Spinal Cord Injury Influences Diffusion Tensor Imaging Of The Brain, Michael B. Jirjis, Aditya Vedantam, Matthew D. Budde, Benjamin Kalinosky, Shekar N. Kurpad
Severity Of Spinal Cord Injury Influences Diffusion Tensor Imaging Of The Brain, Michael B. Jirjis, Aditya Vedantam, Matthew D. Budde, Benjamin Kalinosky, Shekar N. Kurpad
Biomedical Engineering Faculty Research and Publications
Background: The purpose of this study was to determine whether DTI changes in the brain induced by a thoracic spinal cord injury are sensitive to varying severity of spinal contusion in rats.
Methods: A control, mild, moderate, or severe contusion injury was administered over the eighth thoracic vertebral level in 32 Sprague-Dawley rats. At 11 weeks postinjury, ex vivo DTI of the brain was performed on a 9.4T Bruker scanner using a pulsed gradient spin-echo sequence.
Results: Mean water diffusion in the internal capsule regions of the brain and pyramid locations of the brainstem were correlated with motor function (r …
Automated Selection Of The Optimal Cardiac Phase For Single-Beat Coronary Ct Angiography Reconstruction, Daniel Stassi, S. Dutta, H. Ma, A. Soderman, D. Pazzani, E. Gros, D. Okerlund, Taly Gilat-Schmidt
Automated Selection Of The Optimal Cardiac Phase For Single-Beat Coronary Ct Angiography Reconstruction, Daniel Stassi, S. Dutta, H. Ma, A. Soderman, D. Pazzani, E. Gros, D. Okerlund, Taly Gilat-Schmidt
Biomedical Engineering Faculty Research and Publications
Purpose: Reconstructing a low-motion cardiac phase is expected to improve coronary artery visualization in coronary computed tomography angiography (CCTA) exams. This study developed an automated algorithm for selecting the optimal cardiac phase for CCTA reconstruction. The algorithm uses prospectively gated, single-beat, multiphase data made possible by wide cone-beam imaging. The proposed algorithm differs from previous approaches because the optimal phase is identified based on vessel image quality (IQ) directly, compared to previous approaches that included motion estimation and interphase processing. Because there is no processing of interphase information, the algorithm can be applied to any sampling of image phases, …
Material And Structural Aspects Of Bone In Osteogenesis Imperfecta, Carolyne Albert, John Jameson, Peter Smith, Gerald F. Harris
Material And Structural Aspects Of Bone In Osteogenesis Imperfecta, Carolyne Albert, John Jameson, Peter Smith, Gerald F. Harris
Biomedical Engineering Faculty Research and Publications
Bone fragility is a fundamental problem in individuals with osteogenesis imperfecta (OI). The mechanisms behind this fragility, however, are not yet well understood. Multiple factors appear to contribute to the increased fracture risk in OI. At the structural level, bone mass deficiency can result in increased stress levels within bones. The underlying mineral and collagen abnormalities that define OI are also believed to result in compromised material-level properties. The variability of collagen biochemical irregularities causing OI and the corresponding heterogeneity of disease severity result in abnormalities that are not easily generalized within the OI population.
The aims of this chapter …
Motion Analysis Strategy Appropriate For 3d Kinematic Assessment Of Children And Adults With Osteogenesis Imperfecta, Jeffrey D. Kertis, Jessica M. Fritz, Sergey Tarima, Gerald F. Harris
Motion Analysis Strategy Appropriate For 3d Kinematic Assessment Of Children And Adults With Osteogenesis Imperfecta, Jeffrey D. Kertis, Jessica M. Fritz, Sergey Tarima, Gerald F. Harris
Biomedical Engineering Faculty Research and Publications
Human motion analysis provides a quantitative means of assessing whole body and segmental motion of subjects with musculoskeletal pathologies. This chapter describes a low cost motion analysis appropriate for complete three-dimensional (3D) assessment of upper and lower extremity kinematics. The system has been designed to support lower cost outreach efforts that require accuracy and resolution on the order of classical fixed lot systems such as Vicon. The focus of this work addresses the assessment needs typically seen in adults and children with osteogenesis imperfect (OI) experiencing ambulatory and upper extremity challenges.
Quantitative Assessment Of Children With Osteogenesis Imperfecta, Adam Graf, Joseph Krzak, Angela Caudill, Ann Flanagan, Peter Smith, Gerald F. Harris
Quantitative Assessment Of Children With Osteogenesis Imperfecta, Adam Graf, Joseph Krzak, Angela Caudill, Ann Flanagan, Peter Smith, Gerald F. Harris
Biomedical Engineering Faculty Research and Publications
Assessments of children with Osteogenesis Imperfecta (OI) are typically limited to a physical exam and observations from a clinician during a hospital visit. Often quantitative information such as bone mineral density and outcome questionnaires is obtained, but with the increasing prevalence of motion analysis and other performance type laboratories, there are many other tools available, which could be beneficial to this patient population. These laboratories can provide date supplementary to morphologic and radiographic data that is helpful in tracking changes in the patient’s functional abilities, recover from fracture, and treatment outcomes. This chapter will cover some useful evaluation methods for …
Walker Design For Kinetic Assessment Of Upper Extremity Joint Demands In Children With Osteogenesis Imperfecta, Katherine A. Konop, Kelly M.B. Strifling, Mei Wang, Jeffrey P. Schwab, Jeffrey D. Ackman, Peter A. Smith, Gerald F. Harris
Walker Design For Kinetic Assessment Of Upper Extremity Joint Demands In Children With Osteogenesis Imperfecta, Katherine A. Konop, Kelly M.B. Strifling, Mei Wang, Jeffrey P. Schwab, Jeffrey D. Ackman, Peter A. Smith, Gerald F. Harris
Biomedical Engineering Faculty Research and Publications
No abstract provided.
Assessing The Spatial Relationship Between Fixation And Foveal Specializations, Melissa A. Wilk, Adam M. Dubis, Robert F. Cooper, Phyllis Summerfelt, Alfredo Dubra, Joseph Carroll
Assessing The Spatial Relationship Between Fixation And Foveal Specializations, Melissa A. Wilk, Adam M. Dubis, Robert F. Cooper, Phyllis Summerfelt, Alfredo Dubra, Joseph Carroll
Biomedical Engineering Faculty Research and Publications
Increased cone photoreceptor density, an avascular zone (FAZ), and the displacement of inner retinal neurons to form a pit are distinct features of the human fovea. As the fovea provides the majority of our vision, appreciating how these anatomical specializations are related is important for understanding foveal development, normal visual function, and retinal disease. Here we evaluated the relationship between these specializations and their location relative to the preferred retinal locus of fixation (PRL). We measured foveal pit volume, FAZ area, peak cone density, and location of the PRL in 22 subjects with normal vision using optical coherence tomography and …
Motor Output Variability Impairs Driving Ability In Older Adults, Neha Lodha, Hwasil Moon, Changki Kim, Tanya Onushko, Evangelos A. Christou
Motor Output Variability Impairs Driving Ability In Older Adults, Neha Lodha, Hwasil Moon, Changki Kim, Tanya Onushko, Evangelos A. Christou
Biomedical Engineering Faculty Research and Publications
Background: The functional declines with aging relate to deficits in motor control and strength. In this study, we determine whether older adults exhibit impaired driving as a consequence of declines in motor control or strength.
Methods: Young and older adults performed the following tasks: (i) maximum voluntary contractions of ankle dorsiflexion and plantarflexion; (ii) sinusoidal tracking with isolated ankle dorsiflexion; and (iii) a reactive driving task that required responding to unexpected brake lights of the car ahead. We quantified motor control with ankle force variability, gas position variability, and brake force variability. We quantified reactive driving performance with a combination …
Wireless Implantable Magnetoelastic Sensors And Actuators For Biomedical Applications, Andrew Derouin
Wireless Implantable Magnetoelastic Sensors And Actuators For Biomedical Applications, Andrew Derouin
Dissertations, Master's Theses and Master's Reports
Magnetoelastic sensors represent a low-cost wireless and battery-less method for monitoring parameters in embedded or implanted applications; however, some limitations still exist preventing their commercial implementation. Presented in this work are a variety of studies that are aimed at improving the feasibility of magnetoelastic materials for sensing and actuating applications. Magnetoelastic resonant sensors of non-standard geometries were investigated to determine if geometry could play a role on the sensitivity of the sensor response to mass loading. It was shown that a significant increase in sensitivity could be achieved by using triangular sensors rather than standard rectangular strips. A method for …
Design And Development Of Optical Elastography Setup, Abhinav Madhavachandran
Design And Development Of Optical Elastography Setup, Abhinav Madhavachandran
Dissertations, Master's Theses and Master's Reports
The mechanical properties of the skin are an indication of its physiological condition. The properties can serve as potential information for dermatologists for diagnosis and qualitative assessment. Elastography is a medical imaging modality developed to extract the elastic properties of a tissue by application of an external force. Optical elastography is a technique of elastography which uses laser speckle tracking to study the elastic properties of several soft tissue including skin.
This work is aimed at developing an optical elastography setup that can study the elastic properties of skin. The setup includes an imaging system and a force-application system controlled …
Smartphone Microendoscopy For High Resolution Fluorescence Imaging, Xiangqian Hong, Vivek K. Nagarajan, Dale H. Mugler, Bing Yu
Smartphone Microendoscopy For High Resolution Fluorescence Imaging, Xiangqian Hong, Vivek K. Nagarajan, Dale H. Mugler, Bing Yu
Biomedical Engineering Faculty Research and Publications
High resolution optical endoscopes arc increasingly used in diagnosis of various medical conditions of internal organs, such as the cervix and gastrointestinal (GI) tracts, but they are too expensive for use in resource-poor settings. On the other hand, smartphones with high resolution cameras and Internet access have become more affordable, enabling them to diffuse into most rural areas and developing countries in the past decade. In this paper, we describe a smartphone microendoscope that can take fluorescence images with a spatial resolution of 3.1 μm. Images collected from ex vivo, in vitro and in vivo samples using the device …
Inhibition Of Bacterial Growth And Prevention Of Bacterial Adhesion With Localized Nitric Oxide Delivery, Julia Osborne
Inhibition Of Bacterial Growth And Prevention Of Bacterial Adhesion With Localized Nitric Oxide Delivery, Julia Osborne
Dissertations, Master's Theses and Master's Reports
Bacterial infections continue to be a problem at the site of an indwelling medical device, and over the years, various bacterial strains have become more resistant to current antibiotic treatments. Bacterial infection at an indwelling medical device can be dangerous and affect the performance of the medical device which can ultimately lead to the failure of the device due to bacterial resistance to treatment.
Nitric Oxide (NO) has been shown to possess antibacterial properties to prevent and inhibit bacterial growth. NO releasing coatings on indwelling medical devices could provide a reduction in bacterial infections that occur at the device site …
Effects Of Scattering And Absorption On Laser Speckle Contrast Imaging, Kosar Khaksari
Effects Of Scattering And Absorption On Laser Speckle Contrast Imaging, Kosar Khaksari
Dissertations, Master's Theses and Master's Reports
Laser Speckle Contrast Imaging (LSCI) is a real-time, non-invasive method in used to investigate blood flow and perfusion in biological tissues with high temporal and spatial resolution. A reduction in speckle contrast due to particle motion is the primary contrast mechanism in LSCI. Motion results in speckle fluctuations in time and reduces the contrast over a given camera integration period. There are a variety of parameters that effect contrast besides motion. The optical properties of the scattering medium are one of the parameters effecting LSCI values. Changes in blood hematocrit levels manifest as changes in optical properties. In this work, …
Categorizing Fetal Heart Rate Variability With And Without Visual Aids, Amanda J. Ashdown, Mark W. Scerbo, Lee A. Belfore Ii, Stephen S. Davis, Alfred Z. Abuhamad
Categorizing Fetal Heart Rate Variability With And Without Visual Aids, Amanda J. Ashdown, Mark W. Scerbo, Lee A. Belfore Ii, Stephen S. Davis, Alfred Z. Abuhamad
Psychology Faculty Publications
Objective This study examined the ability of clinicians to correctly categorize images of fetal heart rate (FHR) variability with and without the use of exemplars.
Study Design A sample of 33 labor and delivery clinicians inspected static FHR images and categorized them into one of four categories defined by the National Institute of Child Health and Human Development (NICHD) based on the amount of variability within absent, minimal, moderate, or marked ranges. Participants took part in three conditions: two in which they used exemplars representing FHR variability near the center or near the boundaries of each range, and a third …