Open Access. Powered by Scholars. Published by Universities.®
Biomedical Engineering and Bioengineering Commons™
Open Access. Powered by Scholars. Published by Universities.®
- Discipline
-
- Biological Engineering (39)
- Biomedical Devices and Instrumentation (12)
- Medicine and Health Sciences (11)
- Chemical Engineering (8)
- Life Sciences (8)
-
- Physical Sciences and Mathematics (7)
- Bioimaging and Biomedical Optics (6)
- Electrical and Computer Engineering (6)
- Mechanical Engineering (6)
- Molecular, Cellular, and Tissue Engineering (6)
- Biochemical and Biomolecular Engineering (5)
- Biomechanics and Biotransport (5)
- Anatomy (3)
- Biochemistry, Biophysics, and Structural Biology (3)
- Biomedical (3)
- Biotechnology (3)
- Medical Specialties (3)
- Molecular Biology (3)
- Statistics and Probability (3)
- Analytical, Diagnostic and Therapeutic Techniques and Equipment (2)
- Bioelectrical and Neuroengineering (2)
- Biomaterials (2)
- Bioresource and Agricultural Engineering (2)
- Computational Engineering (2)
- Computer Sciences (2)
- Microbiology (2)
- Agriculture (1)
- Biochemistry (1)
- Institution
-
- University of Nebraska - Lincoln (35)
- New Jersey Institute of Technology (32)
- University of Texas at Arlington (27)
- Engineering Conferences International (21)
- Clemson University (16)
-
- Marquette University (15)
- Technological University Dublin (14)
- Cleveland State University (12)
- California Polytechnic State University, San Luis Obispo (11)
- Old Dominion University (8)
- Wright State University (8)
- Missouri University of Science and Technology (7)
- Virginia Commonwealth University (6)
- Louisiana Tech University (5)
- Dartmouth College (4)
- University of Arkansas, Fayetteville (4)
- Boise State University (2)
- Purdue University (2)
- Utah State University (2)
- Brigham Young University (1)
- Loma Linda University (1)
- Louisiana State University (1)
- Michigan Technological University (1)
- Munster Technological University (1)
- San Jose State University (1)
- University of Arkansas Little Rock (1)
- University of Central Florida (1)
- University of Connecticut (1)
- University of Denver (1)
- University of Kentucky (1)
- Keyword
-
- Department of Biomedical, Industrial & Human Factors Engineering (6)
- Biomechanics (3)
- Controlled release (3)
- Drug delivery (3)
- MEMS (3)
-
- Microelectromechanical systems (3)
- Torque (3)
- Ultrasound (3)
- Water quality (3)
- Animal model (2)
- Atherosclerosis (2)
- Biomedical Sciences (2)
- Blood flow (2)
- Bone (2)
- Coronary stent (2)
- Drug Delivery (2)
- EMG (2)
- Electronic books. local (2)
- Electroporation (2)
- Electrospinning (2)
- Evapotranspiration (2)
- FMRI (2)
- Foams (2)
- Force Measurement (2)
- Heart (2)
- Humans (2)
- Ischemia (2)
- Manure management (2)
- Manure runoff (2)
- Mitochondria (2)
- Publication
-
- Theses (33)
- Bioengineering Theses - Archive (26)
- Vaccine Technology II (21)
- Department of Agricultural and Biological Systems Engineering: Faculty Publications (19)
- Biomedical Engineering Faculty Research and Publications (15)
-
- All Dissertations (12)
- ETD Archive (11)
- Biomedical Engineering (9)
- Browse all Theses and Dissertations (8)
- Conference Papers (8)
- Chemical and Biochemical Engineering Faculty Research & Creative Works (7)
- Theses and Dissertations (7)
- Department of Agricultural and Biological Systems Engineering: Presentations and White Papers (6)
- Doctoral Dissertations (5)
- All Theses (4)
- Dartmouth Scholarship (4)
- Department of Agricultural and Biological Systems Engineering: Dissertations, Theses, and Student Research (4)
- Articles (3)
- Biological and Agricultural Engineering Undergraduate Honors Theses (3)
- Electrical & Computer Engineering Theses & Dissertations (3)
- BSE Department Magazine (2)
- Biological Engineering Faculty Publications (2)
- Electronic Theses and Dissertations (2)
- Faculty Publications (2)
- Master's Theses (2)
- Mechanical & Aerospace Engineering Theses & Dissertations (2)
- Mechanical and Biomedical Engineering Faculty Publications and Presentations (2)
- Ravi Saraf Publications (2)
- Adam Liska Papers (1)
- Bioelectrics Publications (1)
- Publication Type
- File Type
Articles 61 - 90 of 244
Full-Text Articles in Biomedical Engineering and Bioengineering
Risedronate Prevents Early Bone Loss Resulting From Whole-Body Irradiation, Eric Livingston
Risedronate Prevents Early Bone Loss Resulting From Whole-Body Irradiation, Eric Livingston
All Theses
Osteoporosis is a condition characterized by a reduction in bone strength resulting in an overall increase in the risk of fracture. There are many factors that contribute to the development of this condition, including ionizing radiation exposure. Declines in bone volume and trabecular micro-architecture have been found following exposure to multiple types of radiation. Past research has implicated reduction of osteoblast function and changes to vasculature as the primary sources of bone deterioration. Recently, an early increase in osteoclast number was observed following exposure to low-energy X-rays, identifying an increase in resorption as a possible cause and potential target for …
Biomechanical Evaluation Of Two Methods Of Humeral Shaft Fixation, Joshua Catanzarite
Biomechanical Evaluation Of Two Methods Of Humeral Shaft Fixation, Joshua Catanzarite
All Theses
Biomechanical evaluations of fracture fixation devices attempt to determine implant performance by approximating the in vivo conditions. This performance is affected by many factors and relies on the complex bone-implant interface. Biomechanical tests can be designed in a variety of ways in order to evaluate device performance with respect to any number of these bone-implant interactions. Standardized tests, designed by groups such as the American Society for Testing and Materials (ASTM), are often designed either to determine the performance of a specific type of fixation device or for direct comparison between different devices. Additionally, many biomechanical evaluations are designed for …
Quantifying Antalgic Gait Knee Function Using Inertial Sensor Technology, William Mostertz
Quantifying Antalgic Gait Knee Function Using Inertial Sensor Technology, William Mostertz
All Theses
The use of body-fixed inertial sensors to analyze human movement may prove useful in the medical field. Improving orthopaedic device design, diagnosing musculoskeletal disorders, and rehabilitation assessment could all benefit from a mobile gait analysis system based on inertial sensors. More specifically, patients recovering from lower limb corrective surgeries tend to adjust gait patterns to accommodate pain, a condition referred to as antalgic gait. Currently there is no quantitative method available to assess recovery for this patient population during post-operative management. A comparison of the inertial sensor system with the camera-based industry standard has confirmed it as a viable method …
Effects Of Narrow Grass Hedges On Nutrient Transport From Land Application Areas, John E. Gilley, Bahman Eghball, David B. Marx
Effects Of Narrow Grass Hedges On Nutrient Transport From Land Application Areas, John E. Gilley, Bahman Eghball, David B. Marx
Department of Agricultural and Biological Systems Engineering: Presentations and White Papers
The placement of stiff-stemmed grass hedges on the contour along a hill slope has been shown to decrease runoff nutrient transport. This study was conducted to measure the effectiveness of a narrow grass hedge in reducing runoff nutrient transport from plots with a range of soil nutrient values. Composted beef cattle manure was applied at dry weights of 0, 68, 105, 142, and 178 Mg ha-1 to a silty clay loam soil and then incorporated by disking. Soil samples were collected 243 days later for analysis of water-soluble phosphorus (WSP), Bray and Kurtz No.1 phosphorus (Bray-1 P), NO3 …
Biodegradable Fluorescent Polymers, Santosh Gautam
Biodegradable Fluorescent Polymers, Santosh Gautam
Bioengineering Theses - Archive
Most of the works done on fluorescent polymers are focused on their potential applications in lighting industries. Much less interest has been paid for their potential application in the field of biology and biomedical engineering. Although multiple biological uses of green fluorescent proteins (GFPs) have been addressed by different groups, their potential for biomedical applications is hampered by their tendency to photobleach rapidly and their short fluorescence lifetime. Quantum dots have emerged as a potential substitute for those applications, but their cytotoxicity and lack of biodegradability restrict their use in a biological system. An ideal fluorescent material that could be …
Visible Versus Near-Infrared Light Penetration Depth Analysis In An Intralipid Suspension As It Relates To Clinical Hyperspectral Images, Tinsy John Perumanoor
Visible Versus Near-Infrared Light Penetration Depth Analysis In An Intralipid Suspension As It Relates To Clinical Hyperspectral Images, Tinsy John Perumanoor
Bioengineering Theses - Archive
We determine the penetration depth of near-infrared and visible light in a tissue phantom model using various image processing techniques and chemometrics and use these results to demonstrate the application of a multimodal hyperspectral imaging system for monitoring blood perfusion in amputation wounds. It is capable of performing a noninvasive, in vivo, quantitative analysis of human tissue in a clinical environment, in terms of the percent saturation of oxyhemoglobin. The instrument majorly consists of near-infrared and visible charge coupled devices (CCDs), lenses, liquid crystal tunable filters (LCTFs) for both the CCDs attached to their respective lenses, and a broad band …
Nutrient And Microbial Transport From Feedlot Surfaces, John E. Gilley, Elaine D. Berry, Roger A. Eigenberg, David B. Marx, Bryan L. Woodbury
Nutrient And Microbial Transport From Feedlot Surfaces, John E. Gilley, Elaine D. Berry, Roger A. Eigenberg, David B. Marx, Bryan L. Woodbury
Department of Agricultural and Biological Systems Engineering: Presentations and White Papers
Nutrient and microbial transport by runoff may vary at different locations within a beef cattle feedlot. If the areas making the largest contributions to nutrient and microbial transport can be identified, it may be possible to institute site-specific management practices to reduce runoff nutrient and microbial transport. The objectives of this study were to: a) measure selected feedlot soil properties, and nutrient and microbial transport in runoff from various feedlot locations b) compare the effects of unconsolidated surface materials (USM) (loose manure pack) and consolidated subsurface materials (CSM) (compacted manure and underlying layers) on nutrient and microbial transport, and c) …
Nanoengineered Templates For Controlled Delivery Of Bioactive Compounds, Nalinkanth Ghone Veerabadran
Nanoengineered Templates For Controlled Delivery Of Bioactive Compounds, Nalinkanth Ghone Veerabadran
Doctoral Dissertations
The significance of any drugs, therapeutic proteins, or any bioactive compounds, is based not only on their effects on diseases but also on how specifically, how readily, how controllable and how prolonged their effects on the disease without having any side effects. Thus the techniques involved in the drug encapsulation and its controlled release for a longer duration of time form one of the important processes of drug reformulation. In recent years nanoparticles have created overwhelming attention for delivering drugs by nanoencapsulation. The smaller size of nanoparticles has longer circulation time and higher cellular uptake when compared with larger size …
A Simulation Of The Neural Action Potential Under The Influence Of Acetylcholinesterase Inhibitors Modeled In The Neuromuscular Junction, Frank Jenkins
Doctoral Dissertations
The rise of terrorism has created an interest in better ways to detect when humans are exposed to neurotoxins, especially nerve gases developed for military use, most of which are acetylcholinesterase inhibitors. Many current methods of detection are based on mass spectrometry, a method that is cumbersome and not particularly robust when used as an early warning method. The detection of acetylcholinesterase inhibitors would benefit from a combined model of the processes occurring in the neuromuscular junction between the presynaptic action potential and the motor end-plate action potential that includes the kinetics of acetylcholine and acetylcholinesterase in the synaptic cleft. …
Poly(Ethylenedioxythiophene) Based Electronic Devices For Sensor Applications, Jie Liu
Poly(Ethylenedioxythiophene) Based Electronic Devices For Sensor Applications, Jie Liu
Doctoral Dissertations
Organic electronic devices, based on Poly (3,4-ethylenedioxythiophene)-Poly (styrene sulfonic acid) (PEDOT-PSS) as the active layer for sensor applications, have been studied. Two sets of sensors have been developed. In one case, sensors consisting of PEDOT-PSS resistors have been realized and demonstrated for soil moisture monitoring. The resistor model for the soil moisture sensor enables the sensor device to be fabricated at low cost and easily tested with a simple structure. Unlike the large dimension device used in Time Domain Reflectometry (TDR), the sensors are small and are capable of capturing microscale behavior of moisture in soil which is useful for …
Force Measurement Methods In Telerobotic Surgery: Implications For End-Effector Manufacture, Dean Callaghan, Mark Mcgrath, Eugene Coyle
Force Measurement Methods In Telerobotic Surgery: Implications For End-Effector Manufacture, Dean Callaghan, Mark Mcgrath, Eugene Coyle
Articles
Haptic feedback in telesurgical applications refers to the relaying of position and force information from a remote surgical site to the surgeon in real-time during a surgical procedure. This feedback, coupled with visual information via microscopic cameras, has the potential to provide the surgeon with additional ‘feel’ for the manipulations being performed at the instrument-biological tissue interface. This increased sensitivity has many associated benefits which include, but are not limited to; minimal tissue damage, reduced recuperation periods, and less patient trauma. The inclusion of haptic feedback leads to reduction in surgeon fatigue which contributes to enhanced performance during operation. Commercially …
Irradiation Of Varying Volumes Of Rat Lung To Same Mean Lung Dose: A Little To A Lot Or A Lot To A Little?, Vladimir A. Semenenko, Robert C. Molthen, Chunrong Li, Natalya V. Morrow, Rongshan Li, Swarajit N. Ghosh, Meetha Medhora, X. Allen Li
Irradiation Of Varying Volumes Of Rat Lung To Same Mean Lung Dose: A Little To A Lot Or A Lot To A Little?, Vladimir A. Semenenko, Robert C. Molthen, Chunrong Li, Natalya V. Morrow, Rongshan Li, Swarajit N. Ghosh, Meetha Medhora, X. Allen Li
Biomedical Engineering Faculty Research and Publications
Purpose: To investigate whether irradiating small lung volumes with a large dose or irradiating large lung volumes with a small dose, given the same mean lung dose (MLD), has a different effect on pulmonary function in laboratory animals.
Methods and Materials: WAG/Rij/MCW male rats were exposed to single fractions of 300 kVp X-rays. Four treatments, in decreasing order of irradiated lung volume, were administered: (1) whole lung irradiation, (2) right lung irradiation, (3) left lung irradiation, and (4) irradiation of a small lung volume with four narrow beams. The irradiation times were chosen to accumulate the same MLD of 10, …
A Force Measurement Evaluation Tool For Telerobotic Cutting Applications: Development Of An Effective Characterization Platform, Dean Callaghan, Mark Mcgrath, Eugene Coyle
A Force Measurement Evaluation Tool For Telerobotic Cutting Applications: Development Of An Effective Characterization Platform, Dean Callaghan, Mark Mcgrath, Eugene Coyle
Articles
Sensorized instruments that accurately measure the interaction forces (between biological tissue and instrument endeffector) during surgical procedures offer surgeons a greater sense of immersion during minimally invasive robotic surgery. Although there is ongoing research into force measurement involving surgical graspers little corresponding effort has been carried out on the measurement of forces between scissor blades and tissue. This paper presents the design and development of a force measurement test apparatus, which will serve as a sensor characterization and evaluation platform. The primary aim of the experiments is to ascertain whether the system can differentiate between tissue samples with differing mechanical …
Medical Image Modeling And Processing, Ramu Pedada
Medical Image Modeling And Processing, Ramu Pedada
Electrical & Computer Engineering Theses & Dissertations
During the last few decades of the twentieth century, medical imaging has been playing a prominent role in many fields of biomedical research and clinical practice. Image modalities such as x-rays, computed tomography (CT), and magnetic resonance images (MRI) have all been valuable additions to the radiologist's arsenal of imaging tools. Medical images assure quality diagnosis and patient safety by gathering valuable information without invading the human body. Apart from clinical diagnosis, medical images are used as tools for education where they are used for training individuals before operating on a patient. Many medical educators tum to simulation based training …
Nicotinic Acetylcholine Receptor Kinetics Of The Neuromuscular Junction Simulated Using Spice: An Illustration Of Physiological Process Simulation With Conventional Circuit Simulation Software, Robert B. Szlavik
Biomedical Engineering
With the advent of modern day computational power, there is a great deal of interest in the simulation and modeling of complex biological systems. A significant effort is being made to develop generalized software packages for the simulation of cellular processes, metabolic pathways and complex biochemical reaction systems. The advantages to being able to implement and simulate complex biological systems in a virtual environment are several. Simulations of this type, if sufficiently detailed, provide experimental physiologists with the ability to visualize the dynamics of a given biological system of interest. The validity of hypotheses related to the system under study …
The Party’S Over: Sustaining Support Programs When The Funding Is Done, John Gardner, Pat Pyke, Cheryl Schrader, Janet M. Callahan, Amy Moll
The Party’S Over: Sustaining Support Programs When The Funding Is Done, John Gardner, Pat Pyke, Cheryl Schrader, Janet M. Callahan, Amy Moll
Mechanical and Biomedical Engineering Faculty Publications and Presentations
In the lifecycle of an engineering education grant, the phase where best practices are sustained and disseminated is perhaps the most crucial stage for maximizing impact. Yet this transition phase often receives the least attention as project team enthusiasm can wane, while funding tapers off, and faculty priorities are pulled in other directions. There are numerous obstacles associated with sustaining program changes, even those perceived as very valuable. Typical challenges are: What happens when the funding runs out? What grant-developed programs should be sustained by the university? Does the institution need to internally allocate resources in an annual budget large …
Action At Distance: A Ms Degree Offered Through Distance Learning As A Vector To Student Enrichment And Industrial Interaction, Lanny Griffin, Daniel Walsh, Robert Crockett, Robert B. Szlavik
Action At Distance: A Ms Degree Offered Through Distance Learning As A Vector To Student Enrichment And Industrial Interaction, Lanny Griffin, Daniel Walsh, Robert Crockett, Robert B. Szlavik
Biomedical Engineering
This paper describes the development and implementation of a flourishing MS program offered through distance learning (DL). The program serves the mission of the university – polytechnic education. It provides an intense life-long-learning opportunity for some of the 300,000 degreed engineers working in California industry who can benefit from graduate education. The DL Masters Degree Program in Engineering with a Biomedical Specialization was designed and developed with verisimilitude to the on-campus program in mind. The distance students attend the same classes as students on campus. The DL program has the same learning objectives and student outcomes as those expected for …
An Automatic Alogorithm For Detecting Stent Endothelialization From Volumetric Optical Coherence Tomography Datasets, Garret T. Bonnema, Kristen O'Halloran Cardinal, Stuart K. Williams, Jennifer K. Barton
An Automatic Alogorithm For Detecting Stent Endothelialization From Volumetric Optical Coherence Tomography Datasets, Garret T. Bonnema, Kristen O'Halloran Cardinal, Stuart K. Williams, Jennifer K. Barton
Biomedical Engineering
Recent research has suggested that endothelialization of vascular stents is crucial to reducing the risk of late stent thrombosis. With a resolution of approximately 10 μm, optical coherence tomography (OCT) may be an appropriate imaging modality for visualizing the vascular response to a stent and measuring the percentage of struts covered with an anti-thrombogenic cellular lining. We developed an image analysis program to locate covered and uncovered stent struts in OCT images of tissue-engineered blood vessels. The struts were found by exploiting the highly reflective and shadowing characteristics of the metallic stent material. Coverage was evaluated by comparing the luminal …
Fluorescence Tomography Characterization For Sub-Surface Imaging With Protoporphyrin Ix, Dax Kepshire, Scott C. Davis, Hamid Dehghani, Keith D. Paulsen, Brian W. Pogue
Fluorescence Tomography Characterization For Sub-Surface Imaging With Protoporphyrin Ix, Dax Kepshire, Scott C. Davis, Hamid Dehghani, Keith D. Paulsen, Brian W. Pogue
Dartmouth Scholarship
Optical imaging of fluorescent objects embedded in a tissue simulating medium was characterized using non-contact based approaches to fluorescence remittance imaging (FRI) and sub-surface fluorescence diffuse optical tomography (FDOT). Using Protoporphyrin IX as a fluorescent agent, experiments were performed on tissue phantoms comprised of typical in-vivo tumor to normal tissue contrast ratios, ranging from 3.5:1 up to 10:1. It was found that tomographic imaging was able to recover interior inclusions with high contrast relative to the background; however, simple planar fluorescence imaging provided a superior contrast to noise ratio. Overall, FRI performed optimally when the object was located on or …
A Selective Recovery Methodology For The Primary Purification Of Lipid Envelope Virus-Like Particles From S. Cerevisiae, Gaik Sui Kee, Hari Pujar, Nigel Titchener-Hooker
A Selective Recovery Methodology For The Primary Purification Of Lipid Envelope Virus-Like Particles From S. Cerevisiae, Gaik Sui Kee, Hari Pujar, Nigel Titchener-Hooker
Vaccine Technology II
No abstract provided.
Well-Characterized Adenoviral Vector-Based Vaccines: Are We There Yet?, Katey Einterz Owen
Well-Characterized Adenoviral Vector-Based Vaccines: Are We There Yet?, Katey Einterz Owen
Vaccine Technology II
No abstract provided.
Vaccine Development For Developing Countries – Regulatory Approach In The European Union, Manfred G. Haase
Vaccine Development For Developing Countries – Regulatory Approach In The European Union, Manfred G. Haase
Vaccine Technology II
No abstract provided.
Analytical And Manufacturing Challenges In Preparation Of Bacterial Polysaccharide Conjugates, Carl Frasch
Analytical And Manufacturing Challenges In Preparation Of Bacterial Polysaccharide Conjugates, Carl Frasch
Vaccine Technology II
No abstract provided.
Quality Issues: The Good-Enough Vaccine, Philip Minor
Quality Issues: The Good-Enough Vaccine, Philip Minor
Vaccine Technology II
No abstract provided.
Development Of Validated Assays For Measuring The Human Antibody Response To Polysaccharide Conjugate Vaccines, Helena Käyhty
Development Of Validated Assays For Measuring The Human Antibody Response To Polysaccharide Conjugate Vaccines, Helena Käyhty
Vaccine Technology II
No abstract provided.
Towards A Therapeutic Hepatitis C Vaccine – A Preclinical And Clinical Learning Curve, Alexander Von Gabain
Towards A Therapeutic Hepatitis C Vaccine – A Preclinical And Clinical Learning Curve, Alexander Von Gabain
Vaccine Technology II
No abstract provided.
Challenge Of Filing 4 New Vaccines At Once – Lessons Learned, Keith Chirgwin
Challenge Of Filing 4 New Vaccines At Once – Lessons Learned, Keith Chirgwin
Vaccine Technology II
No abstract provided.
Veev Replicon-Based Vaccines Used In Heterologous Prime Boost Strategies Induce Lifelong Protection Against Prostate Cancer And Therapy Of Cervical Cancer In Mice And Robust Cell-Mediated Immunity In Rhesus Macaques, W. Martin Kast
Vaccine Technology II
No abstract provided.
Process Intensification For Large Scale Manufacturing Issues, J.C. Drugmand, N. Havelange, N. Alaoui, J. Castillo
Process Intensification For Large Scale Manufacturing Issues, J.C. Drugmand, N. Havelange, N. Alaoui, J. Castillo
Vaccine Technology II
No abstract provided.
Development Of Vaxfectin®-Adjuvanted Dna Vaccines, Alain Rolland
Development Of Vaxfectin®-Adjuvanted Dna Vaccines, Alain Rolland
Vaccine Technology II
No abstract provided.