Open Access. Powered by Scholars. Published by Universities.®

Biomedical Engineering and Bioengineering Commons™

Open Access. Powered by Scholars. Published by Universities.®

2006

Discipline
Institution
Keyword
Publication
Publication Type
File Type

Articles 121 - 150 of 153

Full-Text Articles in Biomedical Engineering and Bioengineering

Properties Of Chitosan Films As A Function Of Ph And Solvent Type, Ki Myong Kim, Jeong Hwa Son, Sung-Koo Kim, Curtis L. Weller, Milford Hanna Jan 2006

Properties Of Chitosan Films As A Function Of Ph And Solvent Type, Ki Myong Kim, Jeong Hwa Son, Sung-Koo Kim, Curtis L. Weller, Milford Hanna

Department of Agricultural and Biological Systems Engineering: Faculty Publications

Two different deacetylated chitosans were dissolved in formic, acetic, lactic, or propionic acid to prepare chitosan films. The pH values of the film-forming solutions were adjusted to 3, 4, and 5. Water vapor permeability (WVP), tensile strength (TS), elongation (E), and total soluble matter (TSM) were significantly (P < 0.05) affected by acid type, pH, and degree of deacetylation (DA). Low DA (LDA) chitosan films had lower WVP and TSM, higher TS compared with high DA (HDA) chitosan films. The E values were not affected by DA. As pH increased, WVP and TSM of chitosan films tended to increase while TS decreased significantly (P < 0.05). Chitosan films with acetic and propionic acid solvents had low WVP and TSM and high TS, while films with lactic acid solvent had high E and TSM and the lowest TS. Fourier-transform infrared showed peak shifting in the spectra with different solvents and at different pH values. Chitosan films with lactic acid solvent showed a peak shift to a lower frequency range. The NH3+ band was absent in the pH 5.0 chitosan film spectra.


Modeling Of Transport Phenomena And Melting Kinetics Of Starch In A Co-Rotating Twin-Screw Extruder, Lijun Wang, David D. Jones, Curtis L. Weller, Milford Hanna Jan 2006

Modeling Of Transport Phenomena And Melting Kinetics Of Starch In A Co-Rotating Twin-Screw Extruder, Lijun Wang, David D. Jones, Curtis L. Weller, Milford Hanna

Department of Agricultural and Biological Systems Engineering: Faculty Publications

A mathematical model was developed to simulate fluid flow, heat transfer, and melting kinetics of starch in a co-rotating intermeshing twin-screw extruder (TSE). The partial differential equations governing the transport phenomena of the biomaterial in the extruder were solved by a finite element scheme. For validating the model, the predicted product pressure, bulk temperature at the entrance of the die, and minimum residence time of the biomaterial in the extruder were compared with experimental data. Standard errors of product pressure, bulk temperature at the die entrance, and minimum residence time were about 8.8, 2.8, and 17.3%. Simulations were carried out …


Nanoelectropulse-Driven Membrane Perturbation And Small Molecule Permeabilization, P. Thomas Vernier, Yinghua Sun, Martin A. Gundersen Jan 2006

Nanoelectropulse-Driven Membrane Perturbation And Small Molecule Permeabilization, P. Thomas Vernier, Yinghua Sun, Martin A. Gundersen

Bioelectrics Publications

Background
Nanosecond, megavolt-per-meter pulsed electric fields scramble membrane phospholipids, release intracellular calcium, and induce apoptosis. Flow cytometric and fluorescence microscopy evidence has associated phospholipid rearrangement directly with nanoelectropulse exposure and supports the hypothesis that the potential that develops across the lipid bilayer during an electric pulse drives phosphatidylserine (PS) externalization.

Results
In this work we extend observations of cells exposed to electric pulses with 30 ns and 7 ns durations to still narrower pulse widths, and we find that even 3 ns pulses are sufficient to produce responses similar to those reported previously. We show here that in contrast to …


Plasma Membrane Voltage Changes During Nanosecond Pulsed Electric Field Exposure, W. Frey, R. O. Price, P. F. Blackmore, R. P. Joshi, R. Nuccitelli, S. J. Beebe, K. H. Schoenbach, J. F. Kolb Jan 2006

Plasma Membrane Voltage Changes During Nanosecond Pulsed Electric Field Exposure, W. Frey, R. O. Price, P. F. Blackmore, R. P. Joshi, R. Nuccitelli, S. J. Beebe, K. H. Schoenbach, J. F. Kolb

Bioelectrics Publications

The change in the membrane potential of Jurkat cells in response to nanosecond pulsed electric fields was studied for pulses with a duration of 60 ns and maximum field strengths of similar to 100 kV/cm (100 V/cell diameter). Membranes of Jurkat cells were stained with a fast voltage-sensitive dye, ANNINE-6, which has a subnanosecond voltage response time. A temporal resolution of 5 ns was achieved by the excitation of this dye with a tunable laser pulse. The laser pulse was synchronized with the applied electric field to record images at times before, during, and after exposure. When exposing the Jurkat …


Resistance To Fracture Of Two All-Ceramic Crown Materials Following Endodontic Access, Kelly Copps Wood, David W. Berzins, Qing Luo, Geoffrey A. Thompson, Jeffrey M. Toth, William W. Nagy Jan 2006

Resistance To Fracture Of Two All-Ceramic Crown Materials Following Endodontic Access, Kelly Copps Wood, David W. Berzins, Qing Luo, Geoffrey A. Thompson, Jeffrey M. Toth, William W. Nagy

Biomedical Engineering Faculty Research and Publications

Statement of problem

There is currently no protocol for managing endodontic access openings for all-ceramic crowns. A direct restorative material is generally used to repair the access opening, rendering a repaired crown as the definitive restoration. This endodontic procedure, however, may weaken the restoration or initiate microcracks that may propagate, resulting in premature failure of the restoration.

Purpose

The purpose of this in vitro study was to evaluate how an endodontic access opening prepared through an all-ceramic crown altered the structural integrity of the ceramic, and the effect of a repair of this access on the load to failure of …


Recent Trends In Robot-Assisted Therapy Environments To Improve Real-Life Functional Performance After Stroke, Michelle J. Johnson Jan 2006

Recent Trends In Robot-Assisted Therapy Environments To Improve Real-Life Functional Performance After Stroke, Michelle J. Johnson

Biomedical Engineering Faculty Research and Publications

Upper and lower limb robotic tools for neuro-rehabilitation are effective in reducing motor impairment but they are limited in their ability to improve real world function. There is a need to improve functional outcomes after robot-assisted therapy. Improvements in the effectiveness of these environments may be achieved by incorporating into their design and control strategies important elements key to inducing motor learning and cerebral plasticity such as mass-practice, feedback, task-engagement, and complex problem solving.

This special issue presents nine articles. Novel strategies covered in this issue encourage more natural movements through the use of virtual reality and real objects and …


Polyetheretherketone As A Biomaterial For Spinal Applications, Jeffrey M. Toth, Mei Wang, Bradley T. Estes, Jeffrey L. Scifert, Howard B. Seim, A. Simon Turner Jan 2006

Polyetheretherketone As A Biomaterial For Spinal Applications, Jeffrey M. Toth, Mei Wang, Bradley T. Estes, Jeffrey L. Scifert, Howard B. Seim, A. Simon Turner

Biomedical Engineering Faculty Research and Publications

Threaded lumbar interbody spinal fusion devices (TIBFD) made from titanium have been reported to be 90% effective for single-level lumbar interbody fusion, although radiographic determination of fusion has been intensely debated in the literature. Using blinded radiographic, biomechanic, histologic, and statistical measures, we evaluated a radiolucent polyetheretherketone (PEEK)-threaded interbody fusion device packed with autograft or rhBMP-2 on an absorbable collagen sponge in 13 sheep at 6 months. Radiographic fusion, increased spinal level biomechanical stiffness, and histologic fusion were demonstrated for the PEEK cages filled with autograft or rhBMP-2 on a collagen sponge. No device degradation or wear debris was observed. …


Intracellular Signaling Networks In The Immune Response: Pathways Activated By Interleukin-2 And-4 Receptors And Their Roles In T Cell Proliferation, Kristen K. Comfort Jan 2006

Intracellular Signaling Networks In The Immune Response: Pathways Activated By Interleukin-2 And-4 Receptors And Their Roles In T Cell Proliferation, Kristen K. Comfort

Chemical and Materials Engineering Faculty Publications

Cells sense and respond to chemical and physical stimuli through signal transduction pathways, which mediate cell proliferation, differentiation, migration, and survival. The cytokines interleukin-2 (IL-2) and interleukin-4 (IL-4) are key regulators of the adaptive immune system, particularly influencing the clonal expansion and differentiation of T cells. At least in culture, both synergistic and antagonistic effects of IL-2 and -4 co-stimulation have been reported; the antagonism, when observed, is thought to arise from the utilization of a common subunit shared by IL-2 and IL-4 receptors. We have sought to characterize IL-2 and IL-4 signaling at the level of intracellular pathways activated …


Osteonal Effects On Elastic Modulus And Fatigue Life In Equine Bone, V. A. Gibson, S. M. Stover, J. C. Gibeling, S. J. Hazelwood, R. B. Martin Jan 2006

Osteonal Effects On Elastic Modulus And Fatigue Life In Equine Bone, V. A. Gibson, S. M. Stover, J. C. Gibeling, S. J. Hazelwood, R. B. Martin

Biomedical Engineering

We hypothesized that recently formed, incompletely mineralized, and thus, relatively deformable osteons in the equine third metacarpus enhance in vitro load-controlled fatigue life in two ways. Macroscopically, there is a compliance effect, because reduced tissue elastic modulus diminishes the stress required to reach a given strain. Microscopically, there is a cement line effect, in which new osteons and their cement lines more effectively serve as barriers to crack propagation. We studied 18 4×10×100 mm beams from the medial, lateral, and dorsal cortices of metacarpal bones from 6 thoroughbred racehorses. Following load-controlled fatigue testing to fracture in 4 point bending, a …


Computational Modeling To Predict Mechanical Function Of Joints: Validations And Applications Of Lower Leg Simulations, Peter C. Liacouras Jan 2006

Computational Modeling To Predict Mechanical Function Of Joints: Validations And Applications Of Lower Leg Simulations, Peter C. Liacouras

Theses and Dissertations

Computational models of musculoskeletal joints and limbs can provide useful information about joint mechanics. Validated models can be used as a predictive device for understanding joint function and serve as a clinical tool for predicting the outcome of surgical procedures. A new computational modeling approach was developed for simulating joint kinematics that are dictated by bone/joint anatomy, ligamentous constraints, and applied loading.Three-dimensional computational models of the lower leg were created. Model development involved generating three-dimensional surfaces from CT images, followed by importing these surfaces into SolidWorks and COSMOSMotion. ThroughSolidWorks and COSMOSMotion, each bone surface was created into a solid object …


Detection, Identification And Classification Of Suck, Swallow And Breathing Activity In Premature Infants During Bottle-Feeding, Fedra Adnani Jan 2006

Detection, Identification And Classification Of Suck, Swallow And Breathing Activity In Premature Infants During Bottle-Feeding, Fedra Adnani

Theses and Dissertations

Prematurity, especially if extreme, is one of the leading causes of problems and/or death after delivery. Among all the problems encountered by premature infants, feeding difficulties are very common. Many premature infants are fed intravenously at first, and they progress to milk feedings provided by a tube passed into the stomach. At around 34 weeks of gestation, premature infants should be able to breastfeed or take a bottle. At the same time such premature infants are usually faced with difficulty making the transition from tube-feeding to full oral feeding. In this study three physiological measurements of premature infants including sucking, …


Reproducing Published Results From In Silico Computer Models Of The Acute Inflammatory Response To Severe Sepsis, Wayne W. Wakeland, Joe Fusion, Brahm Goldstein Jan 2006

Reproducing Published Results From In Silico Computer Models Of The Acute Inflammatory Response To Severe Sepsis, Wayne W. Wakeland, Joe Fusion, Brahm Goldstein

Complex Systems Faculty Publications and Presentations

Recent studies describe computer simulation models of the acute or systemic inflammatory response (AIR or SIR) to severe sepsis, a condition that can lead to multiple organ failure and death. One study used an agent-based model, while the other used differential equations (DEs) to simulate a randomized clinical trial. Both studies obtained results similar to the actual results from a successful clinical drug trial of severe sepsis, suggesting that in silico (simulated) randomized clinical trials may be used to design more effective in vivo clinical trials.


Recombinant Human Bmp-7 Effectively Prevents Non-Union In Both Young And Old Rats, David J. Hak, Takeshi Makino, Takahiro Niikura, Scott J. Hazelwood, Shane Curtiss, A. Hari Reddi Jan 2006

Recombinant Human Bmp-7 Effectively Prevents Non-Union In Both Young And Old Rats, David J. Hak, Takeshi Makino, Takahiro Niikura, Scott J. Hazelwood, Shane Curtiss, A. Hari Reddi

Biomedical Engineering

The purpose of this study was to evaluate the influence of age on the effectiveness of rhBMP-7 treatment in a fracture with severe periosteal damage that is known to result in non-union formation. Closed stabilized femur fractures were produced in 3-month-old and 18-month-old rats. The fracture site was exposed and 2 mm of the periosteum cauterized circumferentially to impair normal fracture healing. The cauterized fracture site was immediately treated with either 100 mg rhBMP-7 (BMP-7 group), or with 25 xL of vehicle alone (control group). Fracture healing was evaluated with radiographs taken at 3 and 6 weeks. Animals were sacrificed …


Postharvest Treatment To Control Codling Moth In Fresh Apples Using Water Assisted Radio Frequency Heating, Shaojin Wang, Sohan Birla, J. D. Hansen Jan 2006

Postharvest Treatment To Control Codling Moth In Fresh Apples Using Water Assisted Radio Frequency Heating, Shaojin Wang, Sohan Birla, J. D. Hansen

Department of Agricultural and Biological Systems Engineering: Faculty Publications

Apples destined for export to Japan and South Korea are currently disinfested for codling moth, Cydia pomonella L. (Lepidoptera: Tortricidae), using methyl bromide fumigation. Restrictions and limitations imposed on the uses of methyl bromide have increased interest in developing alternative non-chemical quarantine treatments. It is imperative that the treatment is effective against codling moth yet maintains the quality of treated apples. The present study explored the application of radio frequency (RF) energy in conjunction with conventional hot water treatment to develop feasible heat treatments. Treatment parameters were selected based on minimum time–temperature conditions required for 100% mortality of fifth-instar codling …


Design Of Near-Optimal Waveforms For Chest And Abdominal Compression And Decompression In Cpr Using Computer-Simulated Evolution, Charles F. Babbs Jan 2006

Design Of Near-Optimal Waveforms For Chest And Abdominal Compression And Decompression In Cpr Using Computer-Simulated Evolution, Charles F. Babbs

Weldon School of Biomedical Engineering Faculty Publications

Objective: To discover design principles underlying the optimal waveforms for external chest and abdominal compression and decompression during cardiac arrest and CPR. Method: A 14-compartment mathematical model of the human cardiopulmonary system is used to test successive generations of randomly mutated external compression waveforms during cardiac arrest and resuscitation. Mutated waveforms that produced superior mean perfusion pressure became parents for the next generation. Selection was based upon either systemic perfusion pressure (SPP=thoracic aortic minus right atrial pressure) or upon coronary perfusion pressure (CPP=thoracic aortic pressure minus myocardial wall pressure). After simulations of 64,414 individual CPR episodes, 40 highly evolved waveforms …


A New Biomechanical Head Injury Criterion, Charles F. Babbs Jan 2006

A New Biomechanical Head Injury Criterion, Charles F. Babbs

Weldon School of Biomedical Engineering Faculty Publications

This paper presents a new analysis of the physics of closed head injury caused by intense acceleration of the head. At rest a 1 cm gap filled with cerebrospinal fluid (CSF) separates the human brain from the skull. During impact whole head acceleration induces artificial gravity within the skull. Because its density differs slightly from that of CSF, the brain accelerates, strikes the inner aspect of the rigid skull, and undergoes viscoelastic deformation. Analytical methods for a lumped parameter model of the brain predict internal brain motions that correlate well with published high-speed photographic studies. The same methods predict a …


Regulation Of Dna Replication Initiation By Histone Acetylation And The Dna Unwinding Element Binding Protein Due-B, Michael George Kemp Jan 2006

Regulation Of Dna Replication Initiation By Histone Acetylation And The Dna Unwinding Element Binding Protein Due-B, Michael George Kemp

Browse all Theses and Dissertations

Duplication of the genome during S phase of the mitotic cell cycle begins at thousands of sites along chromosomes termed origins of replication. Although many of the essential protein components catalyzing events at these sites are known and are conserved throughout eukaryotes, the likelihood or efficiency of initiation of DNA synthesis at any given genomic site is expected to be influenced by other novel factors, including aspects of chromatin and DNA structure.

Here I show that increased histone H4 acetylation at replication origin loci occurs after treatment with the histone deacetylase inhibitor TSA and coincides with a loss of specific …


Methodology For Quantifying Biomechanical Bone Movement Of Transtibial Amputations, Johanna C. Bell Jan 2006

Methodology For Quantifying Biomechanical Bone Movement Of Transtibial Amputations, Johanna C. Bell

Browse all Theses and Dissertations

A controversy has long existed about an alternate below knee amputation procedure that may be more beneficial than the traditional transtibial amputation. The proponents of this alternate procedure that stabilizes the distal tibia and fibula claim it reduces excessive movement of the fibula relative to the tibia that occurs with common movements, such as walking. The purpose of this study is to develop a methodology for quantifying excessive movement of the fibula bone relative to the tibia bone in traditional below the knee amputations. The methodology will measure the movement and rotation of the fibula relative to the tibia. These …


Circular Ultrasound Compounding By Designed Matrix Weighting, Gregory Bashford, Jonathan Morse Jan 2006

Circular Ultrasound Compounding By Designed Matrix Weighting, Gregory Bashford, Jonathan Morse

Department of Agricultural and Biological Systems Engineering: Faculty Publications

Spatial compounding is an imaging technique that aims to improve image contrast by combining partially decorrelated images acquired at different angles or positions. In conventional spatial compounding, data sets are combined with equal weighting. Here, we describe an alternative method of reconstruction using algorithms which weight the data based on a “quality” matrix. The quality matrix is derived from beam-forming characteristics. For each data set, the reliability of the data is assumed to vary spatially. By compounding the data based on the quality matrix, a complete image is formed. Here, we describe the construction of a rotational translation stage and …


Impact Of Tillage And Placement Of Terbufos Insecticide Runoff, Mitiku Mamo, William L. Kranz, Elaine R. Douskey, Shripat T. Kamble, John F. Witkowski Jan 2006

Impact Of Tillage And Placement Of Terbufos Insecticide Runoff, Mitiku Mamo, William L. Kranz, Elaine R. Douskey, Shripat T. Kamble, John F. Witkowski

Department of Agricultural and Biological Systems Engineering: Faculty Publications

On a national scale, the damage caused by corn rootworm (Diabrotica virgifera virgifera LeConte), can cause economic loss of up to $650 million annually. To limit these losses, corn producers apply terbufos insecticide to approximately 11% of all corn acres at a time when there is a high probability of intense precipitation. When combined with low vegetative cover and disturbed soil surfaces, there is a high potential for terbufos transport into surface water bodies. Increased public concern for environmental contamination from the use of agricultural chemicals has prompted many crop growers to look for crop production practices that minimize …


A Mathematical Model For The Validation Of Safe Air-Blast Chilling Of Cooked Hams, L. J. Wang, A Amézquita, Curtis L. Weller Jan 2006

A Mathematical Model For The Validation Of Safe Air-Blast Chilling Of Cooked Hams, L. J. Wang, A Amézquita, Curtis L. Weller

Department of Agricultural and Biological Systems Engineering: Faculty Publications

An integrated mathematical model of heat transfer and temperature-dependent bacterial growth was developed to validate the safety of cooked hams during air-blast chilling. Heat transfer through a cooked ham was mathematically modeled and analyzed with a finite element method. Response of bacteria to temperatures was quantitatively described using predictive microbiology. The cumulative effect of temperature history on the bacterial growth was taken into account in the model. For chilling cooked hams from 71°C to 10°C, the maximum error between the predicted and experimental core temperature was within 2.2°C, and the deviation between the predicted and measured total weight losses was …


Evaluation Of Prototype Cell Delivery Catheters Using Agarose Gel And Cell Culture Experiments, Sagar Panse Jan 2006

Evaluation Of Prototype Cell Delivery Catheters Using Agarose Gel And Cell Culture Experiments, Sagar Panse

Theses and Dissertations

Neurodegenerative diseases and brain tumors affect millions of patients worldwide and are associated with significant morbidity and mortality. The blood brain barrier constitutes a major obstacle to delivery of therapeutic agents administered systemically for treating these disorders. Intracranial drug delivery provides a novel way of bypassing the blood brain barrier and achieving high concentration of therapeutic agents in the brain while avoiding systemic side effects. However damage to tissues during insertion of catheters, release of air in the brain and consequent backtracking of dye are some disadvantages with this mode of treatment. We evaluated prototype cell delivery catheters (each with …


Hmg-Coa Reductase Inhibitors Act Synergistically With Ucn-01 Through Ras Inhibition, Payal Khanna Jan 2006

Hmg-Coa Reductase Inhibitors Act Synergistically With Ucn-01 Through Ras Inhibition, Payal Khanna

Theses and Dissertations

The primary objective of this study is to elucidate the mechanism by which the reagent UCN-01 induces apoptosis when administered to leukemia cells along with HmG-CoA reductase inhibitors, mainly the statins. In this study, we demonstrated that exposure of leukemia cell lines to lovastatin (20 uM, 18 hours) and UCN-01 (100 nM, 18 hours) resulted in mitochondria dysfunction, procaspase 3 and 9 cleavage, and PAW degradation along with marked cytochrome C release and apoptosis. Although similar molecular mechanisms have not yet been confirmed in other cancers, our hypothesis holds that enhanced apoptotic effects of UCN-01 are due in part to …


A Simple, Inexpensive, And Effective Light- Carrying Laryngoscopic Blade For Orotracheal Intubation Of Rats, Robert C. Molthen Jan 2006

A Simple, Inexpensive, And Effective Light- Carrying Laryngoscopic Blade For Orotracheal Intubation Of Rats, Robert C. Molthen

Biomedical Engineering Faculty Research and Publications

The research paradigm of using large laboratory animals, in which oroendotracheal intubations are relatively easy, is shifting toward the use of small animals, such as rodents, in which oropharyngeal access is limited, the arytenoid cartilage cycles are faster, and the glottis is much smaller. The considerable growth recently seen in preclinical imaging studies is accompanied by an increased number of rats and mice requiring in vivo intubation for airway management. Tracheal access is important for ventilation, administration of inhaled anesthetics, instillation of drugs or imaging agents, and maintenance of airway patency to reduce mortality during and after operations. I fashioned …


A Numerical Acoustic Fluid-Structure Simulation Of Therapeutic Ultrasound Angioplasty, Graham Gavin, Finbar Dolan, M.S J. Hashmi, Garrett Mcguinness Jan 2006

A Numerical Acoustic Fluid-Structure Simulation Of Therapeutic Ultrasound Angioplasty, Graham Gavin, Finbar Dolan, M.S J. Hashmi, Garrett Mcguinness

Conference Papers

INTRODUCTION Therapeutic ultrasound angioplasty is the delivery of high amplitude ultrasonic displacements to the distal-tip of small diameter wire waveguides with the goal of disrupting atherosclerotic plaques. This is a minimally invasive procedure that may have potential' in the treatment of complicated chronic total occlusions. The disruption of plaque is due to direct contact ablation and also cavitation, pressure waves and acoustic streaming in the fluid surrounding the vibrating waveguide distal-tip [1]. Cavitation appears to play a major role and some authors have suggested that plaque ablation is only evident above the cavitation threshold [2]. Makin and Everbach [3] performed …


A Numerical Acoustic Fluid-Structure Model Of A Therapeutic Ultrasound Angioplasty Device, Graham Gavin, M.S. J. Hashmi, Finbar Dolan, Garrett Mcguinness Jan 2006

A Numerical Acoustic Fluid-Structure Model Of A Therapeutic Ultrasound Angioplasty Device, Graham Gavin, M.S. J. Hashmi, Finbar Dolan, Garrett Mcguinness

Conference Papers

Ultrasonic angioplasty involves the use of ultrasonic vibrations delivered to the distal-tip of small diameter wire waveguides and is an emerging technology the may have potential use in the treatment of complicated atherosclerotic plaques during cardiovascular surgery. Complicated plaques, including chronic total occlusions and calcified lesions, seriously reduce success rates during standard intervention involving guidewire access, followed by balloon dilation or stent delivery. The large amplitude (0-150 μm) wire waveguide distal-tip displacements in the low-frequency ultrasonic (18-45 kHz) range have been shown to disrupt plaque material by direct contact ablation and cavitation, acoustic streaming and pressure wave components in adjacent …


Synthesising Life-Sciences And Control Engineering: An Outline Survey And A Practical Example, Aidan O'Dwyer Jan 2006

Synthesising Life-Sciences And Control Engineering: An Outline Survey And A Practical Example, Aidan O'Dwyer

Conference papers

There is an increasing interest in life science related areas in the electrical and control engineering community [1]. One manifestation of this interest is the development of interdisciplinary programmes, such as the B.Sc. in Medical Physics and Bioengineering, offered by the Dublin Institute of Technology from September 2005. A significant amount of research work in control engineering has focused on aspects of human physiological system, for example blood glucose regulation [2], cardiovascular modelling and control [3], and limb control [4]. There is an increasing emphasis on interdisciplinary research; in recognition of this, the Institute of Electrical Engineers (IEE) has starting …


Design And Validation Of A Full Contact Gait Simulator For The Cadaveric Lower Extremity, Joseph Michael Iaquinto Jan 2006

Design And Validation Of A Full Contact Gait Simulator For The Cadaveric Lower Extremity, Joseph Michael Iaquinto

Theses and Dissertations

The projects goal was to create a device to simulate full contact gait in the cadaveric lower extremity. The Contact Gait Simulation System loads specific muscles to recreate anatomical dorsi and plantar flexion of the ankle under axial loading. A system of pneumatic load generation was connected a LabVIEW virtual instrument (VI), which controlled the application of these loads. The loads were roughly based off literature cited EMG data, and further modified from feedback. In addition to controlling the load system, the VI also coordinates external sensor timing. Along with this simulator, software was developed specifically for analyzing pressure data …


Development Of A Software Application To Extract The Features Of Normal Respiratory Sounds From The Lungs And The Trachea, Ranjani Sabarinathan Jan 2006

Development Of A Software Application To Extract The Features Of Normal Respiratory Sounds From The Lungs And The Trachea, Ranjani Sabarinathan

Theses and Dissertations

Auscultation has been widely regarded as one of the most important noninvasive diagnostic tools for clinical diagnosis of the respiratory tract. The purpose of this thesis was to develop a software application capable of extracting the key features of respiratory sound signals from the lungs and trachea of healthy persons. The efficacy of the program was evaluated by the verification of the important features of the sound signals from the left and right lungs and the trachea such as 1) right and left lung symmetry and 2) dissimilarity between the trachea and both lungs. The program was developed in LabView …


Determination Of The Mechanical Properties Of Electrospun Gelatin Based On Polymer Concentration And Fiber Alignment, Leander Taylor Iii Jan 2006

Determination Of The Mechanical Properties Of Electrospun Gelatin Based On Polymer Concentration And Fiber Alignment, Leander Taylor Iii

Theses and Dissertations

The process of electrospinning has given the field of tissue engineering insight into many aspects of tissue engineered scaffolds, including how factors such as fiber diameter and porosity are affected by polymer concentration. However, the affects of fiber alignment upon the material properties of electrospun scaffolds remains unclear. The purpose of this study is to determine how the material properties of electrospun gelatin scaffolds are affected by changes in fiber alignment and starting gelatin concentration. Gelatin scaffolds, with starting concentrations of 80, 100, and 130mg/m1, were electrospun onto a target mandrel rotating at various speeds. Samples of each scaffold were …