Open Access. Powered by Scholars. Published by Universities.®

Biomedical Engineering and Bioengineering Commons™

Open Access. Powered by Scholars. Published by Universities.®

2005

Discipline
Institution
Keyword
Publication
Publication Type
File Type

Articles 121 - 133 of 133

Full-Text Articles in Biomedical Engineering and Bioengineering

Bioengineering Instructional Framework For Technology Education, Philip A. Reed, Technology Education Department, Old Dominion University, Virginia Bioengineering Writing Team Jan 2005

Bioengineering Instructional Framework For Technology Education, Philip A. Reed, Technology Education Department, Old Dominion University, Virginia Bioengineering Writing Team

STEMPS Faculty Publications

No abstract provided.


Development And Performance Characteristics Of An Ultrasound Angioplasty Device, Graham Gavin, Garrett Mcguinness, Finbar Dolan, M.S. J. Hashmi Jan 2005

Development And Performance Characteristics Of An Ultrasound Angioplasty Device, Graham Gavin, Garrett Mcguinness, Finbar Dolan, M.S. J. Hashmi

Conference Papers

INTRODUCTION The effect of atherosclerosis is well documented and many procedures such as balloon angioplasty and stentimplantation have been developed to reopen occluded arteries. However, there are considerable differences in the material properties of various atherosclerotic lesions as they develop. Many authors have suggested that rigid calcified plaques may require specific procedures that target this rigid material through de-bulking or complete removal (Salunke et al, 1997). Ultrasound angioplasty is the delivery of high power low frequency ultrasound via a wire waveguide to the lesion location. This results in distal tip wire displacements of up to 100um peak-to-peak (p-p) at frequencies …


Experimental And Numerical Investigation Of Therapeutic Ultrasound Angioplasty, Graham Gavin, M.S. J. Hashmi, Garrett B. Mcguinness Jan 2005

Experimental And Numerical Investigation Of Therapeutic Ultrasound Angioplasty, Graham Gavin, M.S. J. Hashmi, Garrett B. Mcguinness

Other resources

Therapeutic ultrasound angioplasty is an emerging minimally invasive cardiovascular surgical procedure that involves the delivery of ultrasonic displacements to the distal-tip of small diameter wire waveguides. The ultrasonic distal-tip displacements affect atherosclerotic plaque and thrombus by direct contact ablation, pressure wave components and cavitation, in addition to an acoustic streaming event around the distal-tip. This study uses experimental and numerical methods to investigate ultrasonic displacements in wire waveguides and the effect the distal-tip displacements have on the surrounding fluid. An experimental therapeutic ultrasound wire waveguide apparatus is described that delivers displacements to the distal-tip of 1.0 mm and tapered 0.35 …


An Acoustic Fluid-Structure Simulation Of A Theraputic Ultrasound Wire Waveguide Apparatus, Graham Gavin, M.S. Hashmi, Finbar Dolan, Garrett Mcguinness Jan 2005

An Acoustic Fluid-Structure Simulation Of A Theraputic Ultrasound Wire Waveguide Apparatus, Graham Gavin, M.S. Hashmi, Finbar Dolan, Garrett Mcguinness

Conference Papers

The use of high-power low-frequency ultrasound transmitted down small diameter wire waveguides is an emerging technology that may have potential in the treatment of complicated atherosclerotic plaques in cardiovascular surgery. This form of energy delivery results in vibrating the distal-tip of the wire waveguide disrupting material by means of direct contact ablation and also cavitation, pressure waves and acoustic streaming in the surrounding fluid. This work describes a numerical acoustic fluid-structure model of the ultrasound wire waveguide and blood surrounding the distal tip. The structural analysis of the model predicts the natural frequencies of the waveguide and shows the extent …


Room-Temperature Atmospheric Pressure Plasma For Biomedical Applications, Mounir Laroussi, Xinpei Lu Jan 2005

Room-Temperature Atmospheric Pressure Plasma For Biomedical Applications, Mounir Laroussi, Xinpei Lu

Electrical & Computer Engineering Faculty Publications

As low-temperature non-equilibrium plasmas come to play an increasing role in biomedical applications, reliable and user-friendly sources need to be developed. These plasma sources have to meet stringent requirements such as low temperature (at or near room temperature), no risk of arcing, operation at atmospheric pressure, preferably hand-held operation, low concentration of ozone generation, etc. In this letter, we present a device that meets exactly such requirements. This device is capable of generating a cold plasma plume several centimeters in length. It exhibits low power requirements as shown by its current-voltage characteristics. Using helium as a carrier gas, very little …


Myocardial Perfusion Imaging With Rb-82 Pet, George Nittil Francis Jan 2005

Myocardial Perfusion Imaging With Rb-82 Pet, George Nittil Francis

Theses and Dissertations

Myocardial perfusion imaging (MPI) is an effective technique used to study the left ventricular ejection function (LVEF), myocardial perfusion, wall motion, and wall thickening. Positron emission tomography (PET) and single photon emission computed tomography (SPECT) are two modalities that can be used to quantify the left global and regional perfusion at rest and stress. While PET and SPECT rely on similar principles to produce images, important differences in instrumentation and experimental applications are dictated by inherent differences in their respective physics of radioactive decay. With a sensitivity > 90% in combination with a high specificity, PET is today the best available …


The Effects Of Parkinson's On Fixational Stability, Erin L. Mallahan Jan 2005

The Effects Of Parkinson's On Fixational Stability, Erin L. Mallahan

Theses and Dissertations

Parkinson's disease (PD) is a progressive, neurological movement disorder. The stability of eye movements in PD is not well understood but many patients report difficulty doing tasks that require stabilized fixation and gaze. The ability to stabilize an image on the retina is critical is acquiring visual information. The purpose of this study was to compare the stability of fixational eye movements of PD patients to those of age-matched controls. Eye movements during simple fixation tasks were recorded from 66 subjects (ages 52 to 84), and 36 age-matched controls (ages 58-85). The absolute velocity of the fixational eye movements were …


Iterative Methods For The Reconstruction Of Tomographic Images With Unconventional Source-Detector Configurations, Abey Mukkananchery Jan 2005

Iterative Methods For The Reconstruction Of Tomographic Images With Unconventional Source-Detector Configurations, Abey Mukkananchery

Theses and Dissertations

X-ray computed tomography (CT) holds a critical role in current medical practice for the evaluation of patients, particularly in the emergency department and intensive care units. Expensive high resolution stationary scanners are available in radiology departments of most hospitals. In many situations however, a small, inexpensive, portable CT unit would be of significant value. Several mobile or miniature CT scanners are available, but none of these systems have the range, flexibility or overall physical characteristics of a truly portable device. The main challenge is the design of a geometry that optimally trades image quality for system size. The goal of …


Real Time Frequency Analysis Of Signals From Lasso Catheter For Radiofrequency Ablation During Atrial Fibrillation, Prashant Yadav Jan 2005

Real Time Frequency Analysis Of Signals From Lasso Catheter For Radiofrequency Ablation During Atrial Fibrillation, Prashant Yadav

Theses and Dissertations

Real time spectrum analysis of signals obtained through lasso catheter during radiofrequency ablation of pulmonary vein was performed to determine the channel with dominant frequency. Threshold algorithm was used for signals which could be classified as type I and type II AF. Type III AF Signals which were highly fractionated or differentiated were evaluated for frequency content by performing Fast Fourier Transform. Data from Seven patients was collected and an episode of 180 ± 40 seconds was recorded and analyzed for each pulmonary vein that showed electrical activation. Frequency spectra for one second segment of signal for each channel were …


A Physiologically Based Clinical Measure For Spastic Reflexes In Spinal Cord Injury, Ela N. Benz, T. George Hornby, Rita K. Bode, Robert A. Scheidt, Brian D. Schmit Jan 2005

A Physiologically Based Clinical Measure For Spastic Reflexes In Spinal Cord Injury, Ela N. Benz, T. George Hornby, Rita K. Bode, Robert A. Scheidt, Brian D. Schmit

Biomedical Engineering Faculty Research and Publications

Objective: To test the validity of the Spinal Cord Assessment Tool for Spastic reflexes (SCATS), a clinical tool intended to rate spastic motor behavior after spinal cord injury (SCI).

Design: By using correlational analyses, the SCATS was validated using concurrent measurements of kinematics and electromyograms and traditional assessments of spasms and spastic hypertonia.

Setting: Research laboratory (kinematics and electromyography) and outpatient medical clinic (traditional measures of spastic hypertonia).

Participants: Eleven people with SCI were used for kinematic and electromyographic measurements. Seventeen people with SCI were used for comparison with other clinical scales.

Interventions: Not applicable. …


Visual Error Augmentation For Enhancing Motor Learning And Rehabilitative Relearning, Yejun Wei, Preeti Bajaj, Robert A. Scheidt, James L. Patton Jan 2005

Visual Error Augmentation For Enhancing Motor Learning And Rehabilitative Relearning, Yejun Wei, Preeti Bajaj, Robert A. Scheidt, James L. Patton

Biomedical Engineering Faculty Research and Publications

We developed a real-time controller for a 2 degree-of-freedom robotic system using xPC Target. This system was used to investigate how different methods of performance error feedback can lead to faster and more complete motor learning in individuals asked to compensate for a novel visuo-motor transformation (a 30 degree rotation). Four groups of normal human subjects were asked to reach with their unseen arm to visual targets surrounding a central starting location. A cursor tracking hand motion was provided during each reach. For one group of subjects, deviations from the "ideal" compensatory hand movement (i.e. trajectory errors) were amplified with …


Characterization Of Motor Adaptation And Limb Posture Regulation During Arm Reaching Movements Following Stroke, Robert A. Scheidt, Tina M. Stoeckmann Jan 2005

Characterization Of Motor Adaptation And Limb Posture Regulation During Arm Reaching Movements Following Stroke, Robert A. Scheidt, Tina M. Stoeckmann

Biomedical Engineering Faculty Research and Publications

Whether attempting to pour water into a handheld glass, or simply trying to hold a young child's hand, many activities of daily living require interaction with unpredictable or uncertain mechanical environments. Here we describe a systems identification study that used a planar manipulandum to characterize how hemiparetic stroke survivors adapt reaching movements to novel mechanical environments. By analyzing trial-by-trial variations in hand path kinematics, we found that stroke survivors are less likely than neurologically-intact subjects to adjust motor commands for upcoming movements based on hand trajectory errors experienced on previous trials. This ability is most significantly compromised in subjects with …


A Real-Time Haptic/Graphic Demonstration Of How Error Augmentation Can Enhance Learning, Yejun Wei, James L. Patton, Preeti Bajaj, Robert A. Scheidt Jan 2005

A Real-Time Haptic/Graphic Demonstration Of How Error Augmentation Can Enhance Learning, Yejun Wei, James L. Patton, Preeti Bajaj, Robert A. Scheidt

Biomedical Engineering Faculty Research and Publications

We developed a real-time controller for a 2 degree-of-freedom robotic system using xPC Target. This system was used to investigate how different methods of performance error feedback can lead to faster and more complete motor learning in individuals asked to compensate for a novel visuo-motor transformation (a 30 degree rotation). Four groups of human subjects were asked to reach with their unseen arm to visual targets surrounding a central starting location. A cursor tracking hand motion was provided during each reach. For one group of subjects, deviations from the “ideal” compensatory hand movement (i.e. trajectory errors) were amplified with a …