Open Access. Powered by Scholars. Published by Universities.®
Biomedical Engineering and Bioengineering Commons™
Open Access. Powered by Scholars. Published by Universities.®
- Discipline
-
- Medicine and Health Sciences (4)
- Physical Sciences and Mathematics (4)
- Physical Therapy (4)
- Rehabilitation and Therapy (4)
- Mathematics (3)
-
- Vision Science (3)
- Biomechanics and Biotransport (2)
- Electrical and Computer Engineering (2)
- Mechanical Engineering (2)
- Bioelectrical and Neuroengineering (1)
- Bioimaging and Biomedical Optics (1)
- Biological Engineering (1)
- Biological and Chemical Physics (1)
- Biomechanical Engineering (1)
- Computer Sciences (1)
- Education (1)
- Physics (1)
- Psychology (1)
- Science and Mathematics Education (1)
- Social and Behavioral Sciences (1)
- Statistics and Probability (1)
- Keyword
-
- Biomechanics (15)
- Gait (15)
- Rehabilitation (14)
- Stroke (14)
- Spinal cord injury (12)
-
- Adaptive optics (10)
- Computed tomography (10)
- Diffusion tensor imaging (10)
- FMRI (10)
- Kinematics (9)
- Locomotion (9)
- Mitochondria (9)
- Motor control (9)
- Proprioception (9)
- Heart (8)
- EEG (7)
- Hemodynamics (7)
- Human (7)
- Hypertension (7)
- Lung (7)
- Micro-CT (7)
- Restenosis (7)
- Upper extremity (7)
- Active or adaptive optics (6)
- Finite element analysis (6)
- Hyperoxia (6)
- Magnetic resonance imaging (6)
- Mathematical modeling (6)
- Osteogenesis imperfecta (6)
- Rat (6)
- Publication Year
Articles 481 - 510 of 604
Full-Text Articles in Biomedical Engineering and Bioengineering
Imaging Radiation Pneumonitis In A Rat Model Of A Radiological Terrorism Incident, Robert C. Molthen, Qingping Wu, Gary S. Krenz, Meetha Medhora, Elizabeth R. Jacobs, John E. Moulder
Imaging Radiation Pneumonitis In A Rat Model Of A Radiological Terrorism Incident, Robert C. Molthen, Qingping Wu, Gary S. Krenz, Meetha Medhora, Elizabeth R. Jacobs, John E. Moulder
Biomedical Engineering Faculty Research and Publications
We have developed a rat model of single, sub-lethal thoracic irradiation. Our irradiation protocol is considered representative of exposures near the detonation site of a dirty bomb or small nuclear device. The model is being used to investigate techniques for identifying, triaging and treating possible victims. In addition to physiological markers of right ventricular hypertrophy, pulmonary vascular resistance, and arterial distensibility, we present two methods for quantifying microvascular density. We used methods including microfocal X-ray imaging to investigate changes in lung structure/function resulting from radiation exposure. Radiation pneumonitis is a complication in subjects receiving thoracic irradiation. A radiographic hallmark of …
Functional Stability Of Transfemoral Amputee Gait Using The 3r80 And Total Knee 2000 Prosthetic Knee Units, M. Barbara Silver-Thorn, Christine L. Glaister
Functional Stability Of Transfemoral Amputee Gait Using The 3r80 And Total Knee 2000 Prosthetic Knee Units, M. Barbara Silver-Thorn, Christine L. Glaister
Biomedical Engineering Faculty Research and Publications
Prosthetic knee designs have become extremely sophisticated compared to early constant friction single axis mechanisms. Today, prosthetists and physicians have a wide variety of components to choose from for their transfemoral amputee patients. Unfortunately, there are little quantitative data comparing the performance of different types of prosthetic components, and prosthetic prescription is often based on empirical knowledge and experience, rather than objective comparison of prosthetic designs. This study used gait analysis to objectively evaluate the stability characteristics of two types of prosthetic knee designs, the polycentric Total Knee 2000 (Ossur, Aliso Viejo, CA) and the single axis 3R80 stance control …
Preliminary Feasibility Of Dedicated Breast Ct With An Inverse Geometry, Taly Gilat-Schmidt
Preliminary Feasibility Of Dedicated Breast Ct With An Inverse Geometry, Taly Gilat-Schmidt
Biomedical Engineering Faculty Research and Publications
In this study we theoretically investigated the minimum scan time of an inverse-geometry dedicated breast CT system that provides sufficient sampling and dose equivalent to mammography without exceeding the limits of source power or detector count rate. The inverse geometry, which utilizes a large-area scanned source and a narrower photon-counting detector, is expected to have improved dose efficiency compared to cone-beam methods due to reduced scatter effects and improved detector efficiency. The analysis assumed the specifications of available inverse-geometry source and detector hardware (SBDX, NovaRay, Inc, Newark CA). The scan time was calculated for a 10, 14, and 18-cm diameter …
A Device For Noninvasive Assessment Of Vascular Impairment Risk In The Lower Extremity, Michael J. Hoffmann, Paul E. Knudson, M. Barbara Silver-Thorn
A Device For Noninvasive Assessment Of Vascular Impairment Risk In The Lower Extremity, Michael J. Hoffmann, Paul E. Knudson, M. Barbara Silver-Thorn
Biomedical Engineering Faculty Research and Publications
The repeatability and resolution of the clinical gold standard of vascular assessment, the ankle-brachial index (ABI), was compared to that of a new device that dynamically assesses tissue perfusion during external loading utilizing laser Doppler flowmetry. Eight subjects of varying levels of vascular impairment were tested in successive weeks using two different sites on the subject's posterior calf. These new measures included the perfusion decrease as well as the unloading delay during cyclic loading. Some new dynamic tissue perfusion measures demonstrated comparable levels of reproducibility with the ABI (e.g., 10%-20%). Only the unloading delay showed potentially enhanced resolution over ABI …
Low-Flow Perfusion Of Guinea Pig Isolated Hearts With 26°C Air-Saturated Lifor Solution For 20 Hours Preserves Function And Metabolism, David F. Stowe, Amadou K.S. Camara, James S. Heisner, Mohammed Aldakkak, David R. Harder
Low-Flow Perfusion Of Guinea Pig Isolated Hearts With 26°C Air-Saturated Lifor Solution For 20 Hours Preserves Function And Metabolism, David F. Stowe, Amadou K.S. Camara, James S. Heisner, Mohammed Aldakkak, David R. Harder
Biomedical Engineering Faculty Research and Publications
Background
Donor human hearts cannot be preserved for >5 hours between explantation and recipient implantation. A better approach is needed to preserve transplantable hearts for longer periods, ideally at ambient conditions for transport. We tested whether Lifor solution could satisfactorily preserve guinea pig isolated hearts perfused at low flow with no added oxygen at room temperature for 20 hours.
Methods
Hearts were isolated from 18 guinea pigs and perfused initially with oxygenated Krebs–Ringer (KR) solution at 37°C. Hearts were then perfused with recirculated Lifor or cardioplegia (CP) solution (K+ 15 mmol/liter) equilibrated with room air at 20% of control …
Enhanced Na+/H+ Exchange During Ischemia And Reperfusion Impairs Mitochondrial Bioenergetics And Myocardial Function, Mohammed Aldakkak, David F. Stowe, James S. Heisner, Marisha Spence, Amadou K.S. Camara
Enhanced Na+/H+ Exchange During Ischemia And Reperfusion Impairs Mitochondrial Bioenergetics And Myocardial Function, Mohammed Aldakkak, David F. Stowe, James S. Heisner, Marisha Spence, Amadou K.S. Camara
Biomedical Engineering Faculty Research and Publications
Inhibition of Na+/H+ exchange (NHE) during ischemia reduces cardiac injury due to reduced reverse mode Na+/Ca2+ exchange. We hypothesized that activating NHE-1 at buffer pH 8 during ischemia increases mitochondrial oxidation, Ca2+ overload, and reactive O2 species (ROS) levels and worsens functional recovery in isolated hearts and that NHE inhibition reverses these effects. Guinea pig hearts were perfused with buffer at pH 7.4 (control) or pH 8 +/- NHE inhibitor eniporide for 10 minutes before and for 10 minutes after 35- minute ischemia and then for 110 minutes with pH 7.4 buffer alone. Mitochondrial NADH and FAD, [Ca2+], and superoxide …
Irradiation Of Varying Volumes Of Rat Lung To Same Mean Lung Dose: A Little To A Lot Or A Lot To A Little?, Vladimir A. Semenenko, Robert C. Molthen, Chunrong Li, Natalya V. Morrow, Rongshan Li, Swarajit N. Ghosh, Meetha Medhora, X. Allen Li
Irradiation Of Varying Volumes Of Rat Lung To Same Mean Lung Dose: A Little To A Lot Or A Lot To A Little?, Vladimir A. Semenenko, Robert C. Molthen, Chunrong Li, Natalya V. Morrow, Rongshan Li, Swarajit N. Ghosh, Meetha Medhora, X. Allen Li
Biomedical Engineering Faculty Research and Publications
Purpose: To investigate whether irradiating small lung volumes with a large dose or irradiating large lung volumes with a small dose, given the same mean lung dose (MLD), has a different effect on pulmonary function in laboratory animals.
Methods and Materials: WAG/Rij/MCW male rats were exposed to single fractions of 300 kVp X-rays. Four treatments, in decreasing order of irradiated lung volume, were administered: (1) whole lung irradiation, (2) right lung irradiation, (3) left lung irradiation, and (4) irradiation of a small lung volume with four narrow beams. The irradiation times were chosen to accumulate the same MLD of 10, …
Biomechanical And Radiographic Evaluation Of An Ovine Model For The Human Lumbar Spine, Nina E. Easley, M. Wang, Linda M. Mcgrady, Jeffrey M. Toth
Biomechanical And Radiographic Evaluation Of An Ovine Model For The Human Lumbar Spine, Nina E. Easley, M. Wang, Linda M. Mcgrady, Jeffrey M. Toth
Biomedical Engineering Faculty Research and Publications
While various species of animal models have been used in preclinical investigations of spinal implant devices to assess their biological adaptation and biomechanical performance, few studies have made comprehensive comparisons to validate their suitability of modelling the human spine. The purpose of this study was to assess essential biomechanical behaviours and disc morphology of the ovine lumbar model. Flexibility testing was conducted on the spines (L3—L4 and L4—L5) of nine skeletally matured sheep. Segmental rotation and intradiscal pressure were measured and load sharing between the intervertebral disc and posterior elements were calculated on the basis of a simplified parallel spring …
Bronchial Circulation Angiogenesis In The Rat Quantified With Spect And Micro-Ct, Christian Wieholt, David L. Roerig, John B. Gordon, Steven Thomas Haworth, Robert C. Molthen, Anne V. Clough
Bronchial Circulation Angiogenesis In The Rat Quantified With Spect And Micro-Ct, Christian Wieholt, David L. Roerig, John B. Gordon, Steven Thomas Haworth, Robert C. Molthen, Anne V. Clough
Biomedical Engineering Faculty Research and Publications
Introduction
As pulmonary artery obstruction results in proliferation of the bronchial circulation in a variety of species, we investigated this angiogenic response using single photon emission computed tomography (SPECT) and micro-CT.
Materials and methods
After surgical ligation of the left pulmonary artery of rats, they were imaged at 10, 20, or 40 days post-ligation. Before imaging, technetium-labeled macroaggregated albumin (99mTc MAA) was injected into the aortic arch (IA) labeling the systemic circulation. SPECT/micro-CT imaging was performed, the image volumes were registered, and activity in the left lung via the bronchial circulation was used as a marker of bronchial …
Contributions Of Online Visual Feedback To The Learning And Generalization Of Novel Finger Coordination Patterns, Xiaolin Liu, Robert A. Scheidt
Contributions Of Online Visual Feedback To The Learning And Generalization Of Novel Finger Coordination Patterns, Xiaolin Liu, Robert A. Scheidt
Biomedical Engineering Faculty Research and Publications
We explored how people learn new ways to move objects through space using neuromuscular control signals having more degrees of freedom than needed to unambiguously specify object location. Subjects wore an instrumented glove that recorded finger motions. A linear transformation matrix projected joint angle signals (a high-dimensional control vector) onto a two-dimensional cursor position on a video monitor. We assessed how visual information influences learning and generalization of novel finger coordination patterns as subjects practiced using hand gestures to manipulate cursor location. Three groups of test subjects practiced moving a visible cursor between different sets of screen targets. The hand-to-screen …
Katp Channel Openers Have Opposite Effects On Mitochondrial Respiration Under Different Energetic Conditions, Matthias L. Riess, Amadou K.S. Camara, André Heinen, Janis T. Eells, Michele M. Henry, David F. Stowe
Katp Channel Openers Have Opposite Effects On Mitochondrial Respiration Under Different Energetic Conditions, Matthias L. Riess, Amadou K.S. Camara, André Heinen, Janis T. Eells, Michele M. Henry, David F. Stowe
Biomedical Engineering Faculty Research and Publications
Mitochondrial (m) KATP channel opening has been implicated in triggering cardiac preconditioning. Its consequence on mitochondrial respiration, however, remains unclear. We investigated the effects of two different KATP channel openers and antagonists on mitochondrial respiration under two different energetic conditions. Oxygen consumption was measured for complex I (pyruvate/malate) or complex II (succinate with rotenone) substrates in mitochondria from fresh guinea pig hearts. One of two mKATP channel openers, pinacidil or diazoxide, was given before adenosine diphosphate in the absence or presence of an mKATP channel antagonist, glibenclamide or 5-hydroxydecanoate. Without ATP synthase inhibition, both mKATP …
Bioresorbable Polylactide Interbody Implants In An Ovine Anterior Cervical Discectomy And Fusion Model: Three-Year Results, Kevin A. Thomas, Jeffrey M. Toth, Neil R. Crawford, Howard Seim, Lewis L. Shi, Mitchel B. Harris, Anthony S. Turner
Bioresorbable Polylactide Interbody Implants In An Ovine Anterior Cervical Discectomy And Fusion Model: Three-Year Results, Kevin A. Thomas, Jeffrey M. Toth, Neil R. Crawford, Howard Seim, Lewis L. Shi, Mitchel B. Harris, Anthony S. Turner
Biomedical Engineering Faculty Research and Publications
Study Design.
In vivo study of anterior discectomy and fusion using a bioresorbable 70:30 poly(l-lactide-co-d,l-lactide) interbody implant in an ovine model.
Objective.
To evaluate the efficacy of the polylactide implant to function as an interbody fusion device, and to assess the tissue reaction to the material during the resorption process.
Summary of Background Data.
The use of polylactide as a cervical interbody implant has several potential advantages when compared with traditional materials. Having an elastic modulus very similar to bone minimizes the potential for stress shielding, and as the material resorbs additional loading is transferred to the developing fusion mass. …
An Effect Of Relative Motion On Trajectory Discrimination, Scott A. Beardsley, Lucia M. Vaina
An Effect Of Relative Motion On Trajectory Discrimination, Scott A. Beardsley, Lucia M. Vaina
Biomedical Engineering Faculty Research and Publications
Psychophysical studies point to the existence of specialized mechanisms sensitive to the relative motion between an object and its background. Such mechanisms would seem ideal for the motion-based segmentation of objects; however, their properties and role in processing the visual scene remain unclear. Here we examine the contribution of relative motion mechanisms to the processing of object trajectory. In a series of four psychophysical experiments we examine systematically the effects of relative direction and speed differences on the perceived trajectory of an object against a moving background. We show that background motion systematically influences the discrimination of object direction. …
Leg Sympathetic Response To Noxious Skin Stimuli Is Similar In High And Low Level Human Spinal Cord Injury, M. Kevin Garrison, Alexander V. Ng, Brian D. Schmit
Leg Sympathetic Response To Noxious Skin Stimuli Is Similar In High And Low Level Human Spinal Cord Injury, M. Kevin Garrison, Alexander V. Ng, Brian D. Schmit
Biomedical Engineering Faculty Research and Publications
Objective
To determine if sympathetically mediated vasoconstriction in the lower extremities is injury level dependent. Although sympathetic responses have been measured in the limbs of people with high and low level SCI using blood flow measurements, including Doppler ultrasound and venous plethysmography, a direct comparison between injury levels has not been made.
Methods
Volunteers with chronic SCI were grouped according to injury level. Above T6: high level (HL, n = 7), and T6 and below: low level (LL, n = 6). All subjects had complete motor and sensory loss. Leg arterial flows were recorded by venous occlusion plethysmography, and continuous …
Mineral Trioxide Aggregate Material Use In Endodontic Treatment: A Review Of The Literature, Howard W. Roberts, Jeffrey M. Toth, David W. Berzins, David G. Charlton
Mineral Trioxide Aggregate Material Use In Endodontic Treatment: A Review Of The Literature, Howard W. Roberts, Jeffrey M. Toth, David W. Berzins, David G. Charlton
Biomedical Engineering Faculty Research and Publications
Objective
The purpose of this paper was to review the composition, properties, biocompatibility, and the clinical results involving the use of mineral trioxide aggregate (MTA) materials in endodontic treatment.
Methods
Electronic search of scientific papers from January 1990 to August 2006 was accomplished using PubMed and Scopus search engines (search terms: MTA, GMTA, WMTA, mineral AND trioxide AND aggregate).
Results
Selected exclusion criteria resulted in 156 citations from the scientific, peer-reviewed dental literature. MTA materials are derived from a Portland cement parent compound and have been demonstrated to be biocompatible endodontic repair materials, with its biocompatible nature strongly suggested by …
Mechanical Behavior And Failure Analysis Of Prosthetic Retaining Screws After Long‐Term Use In Vivo. Part 4: Failure Analysis Of 10 Fractured Retaining Screws Retrieved From Three Patients, Youssef S. Al Jabbari, Raymond Fournelle, Gerald J. Ziebert, Jeffrey M. Toth, Anthony Iacopino
Mechanical Behavior And Failure Analysis Of Prosthetic Retaining Screws After Long‐Term Use In Vivo. Part 4: Failure Analysis Of 10 Fractured Retaining Screws Retrieved From Three Patients, Youssef S. Al Jabbari, Raymond Fournelle, Gerald J. Ziebert, Jeffrey M. Toth, Anthony Iacopino
Biomedical Engineering Faculty Research and Publications
Purpose: The aim of this study was to perform a failure analysis on fractured prosthetic retaining screws after long‐term use in vivo. Additionally, the study addresses the commonly asked question regarding whether complex repeated functional occlusal forces initiate fatigue‐type cracks in prosthetic retaining screws.
Materials and Methods: Ten fractured prosthetic retaining screws retrieved from three patients treated with fixed detachable hybrid prostheses were subjected to a failure analysis. In patients 1 and 2, the middle three retaining screws of the prostheses were found fractured at retrieval time after they had been in service for 20 and 19 months, respectively. In …
Mechanical Behavior And Failure Analysis Of Prosthetic Retaining Screws After Long‐Term Use In Vivo. Part 3: Preload And Tensile Fracture Load Testing, Youssef S. Al Jabbari, Raymond Fournelle, Gerald J. Ziebert, Jeffrey M. Toth, Anthony Iacopino
Mechanical Behavior And Failure Analysis Of Prosthetic Retaining Screws After Long‐Term Use In Vivo. Part 3: Preload And Tensile Fracture Load Testing, Youssef S. Al Jabbari, Raymond Fournelle, Gerald J. Ziebert, Jeffrey M. Toth, Anthony Iacopino
Biomedical Engineering Faculty Research and Publications
Purpose: The aim of this study was to determine the preload and tensile fracture load values of prosthetic retaining screws after long‐term use in vivo compared to unused screws (controls). Additionally, the investigation addressed whether the preload and fracture load values of prosthetic retaining screws reported by the manufacturer become altered after long‐term use in vivo.
Materials and Methods: For preload testing, 10 new screws (controls) from Nobel Biocare (NB) and 73 used retaining screws [58 from NB and 15 from Sterngold (SG)] were subjected to preload testing. For tensile testing, eight controls from NB and 58 used retaining screws …
Site-Specific Effects Of Pecam-1 On Atherosclerosis In Ldl Receptor-Deficient Mice, Shikha Arora, Brian Boylan, Reema Goel, Benjamin R. Schrank, Barbara Fleming, Rose Ann Fleming, Hiroto Mirura, Peter J. Newman, Robert C. Molthen, Debra K. Newman
Site-Specific Effects Of Pecam-1 On Atherosclerosis In Ldl Receptor-Deficient Mice, Shikha Arora, Brian Boylan, Reema Goel, Benjamin R. Schrank, Barbara Fleming, Rose Ann Fleming, Hiroto Mirura, Peter J. Newman, Robert C. Molthen, Debra K. Newman
Biomedical Engineering Faculty Research and Publications
Objective—Atherosclerosis is a vascular disease that involves lesion formation at sites of disturbed flow under the influence of genetic and environmental factors. Endothelial expression of adhesion molecules that enable infiltration of immune cells is important for lesion development. Platelet/endothelial cell adhesion molecule-1 (PECAM-1; CD31) is an adhesion and signaling receptor expressed by many cells involved in atherosclerotic lesion development. PECAM-1 transduces signals required for proinflammatory adhesion molecule expression at atherosusceptible sites; thus, it is predicted to be proatherosclerotic. PECAM-1 also inhibits inflammatory responses, on which basis it is predicted to be atheroprotective.
Methods and Results—We evaluated herein the effect of …
Different Learned Coordinate Frames For Planning Trajectories And Final Positions In Reaching, Claude Ghez, Robert A. Scheidt, Hank Heijink
Different Learned Coordinate Frames For Planning Trajectories And Final Positions In Reaching, Claude Ghez, Robert A. Scheidt, Hank Heijink
Biomedical Engineering Faculty Research and Publications
We previously reported that the kinematics of reaching movements reflect the superimposition of two separate control mechanisms specifying the hand's spatial trajectory and its final equilibrium position. We now asked whether the brain maintains separate representations of the spatial goals for planning hand trajectory and final position. One group of subjects learned a 30° visuomotor rotation about the hand's starting point while performing a movement reversal task (“slicing”) in which they reversed direction at one target and terminated movement at another. This task required accuracy in acquiring a target mid-movement. A second group adapted while moving to—and stabilizing at—a single …
Prolonged Quadriceps Activity Following Imposed Hip Extension: A Neurophysiological Mechanism For Stiff-Knee Gait?, Michael D. Lewek, T. George Hornby, Yasin Y. Dhaher, Brian D. Schmit
Prolonged Quadriceps Activity Following Imposed Hip Extension: A Neurophysiological Mechanism For Stiff-Knee Gait?, Michael D. Lewek, T. George Hornby, Yasin Y. Dhaher, Brian D. Schmit
Biomedical Engineering Faculty Research and Publications
The biomechanical characteristics of stiff knee gait following neurological injury include decreased knee flexion velocity at toe-off, which may be due to exaggerated quadriceps activity. The neuromuscular mechanism underlying this abnormal activity is unclear, although hyperexcitable heteronymous reflexes may be a source of impaired coordination. The present study examines the contribution of reflex activity from hip flexors on knee extensors following stroke and its association with reduced swing-phase knee flexion during walking. Twelve individuals poststroke and six control subjects were positioned in supine on a Biodex dynamometer with the ankle and knee held in a static position. Isolated hip extension …
Separate Adaptive Mechanisms For Controlling Trajectory And Final Position In Reaching, Robert A. Scheidt, Claude Ghez
Separate Adaptive Mechanisms For Controlling Trajectory And Final Position In Reaching, Robert A. Scheidt, Claude Ghez
Biomedical Engineering Faculty Research and Publications
We examined control of the hand's trajectory (direction and shape) and final equilibrium position in horizontal planar arm movements by quantifying transfer of learned visuomotor rotations between two tasks that required aiming the hand to the same spatial targets. In a trajectory-reversal task (“slicing”), the hand reversed direction within the target and returned to the origin. In a positioning task (“reaching”), subjects moved the hand to the target and held it there; cursor feedback was provided only after movement ended to isolate learning of final position from trajectory direction. We asked whether learning acquired in one task would transfer to …
Mechanical Behavior And Failure Analysis Of Prosthetic Retaining Screws After Long‐Term Use In Vivo. Part 1: Characterization Of Adhesive Wear And Structure Of Retaining Screws, Youssef S. Al Jabbari, Raymond Fournelle, Gerald J. Ziebert, Jeffrey M. Toth, Anthony Iacopino
Mechanical Behavior And Failure Analysis Of Prosthetic Retaining Screws After Long‐Term Use In Vivo. Part 1: Characterization Of Adhesive Wear And Structure Of Retaining Screws, Youssef S. Al Jabbari, Raymond Fournelle, Gerald J. Ziebert, Jeffrey M. Toth, Anthony Iacopino
Biomedical Engineering Faculty Research and Publications
Purpose: The general aim of this study and those presented in Parts 2–4 of this series was to characterize the structure, properties, wear, and fracture of prosthetic retaining screws in fixed detachable hybrid prostheses after long‐term use in vivo. This part of the overall investigation addresses whether there are differences in thread wear between the screws closest to the fulcrum and those that are farthest from the fulcrum in fixed detachable hybrid prostheses.
Materials and Methods: The total number of prosthetic retaining screws used in this study was 100 (10 new and 90 used). New screws (controls) from Nobel Biocare …
Mechanical Behavior And Failure Analysis Of Prosthetic Retaining Screws After Long‐Term Use In Vivo. Part 2: Metallurgical And Microhardness Analysis, Youssef S. Al Jabbari, Raymond Fournelle, Gerald J. Ziebert, Jeffrey M. Toth, Anthony Iacopino
Mechanical Behavior And Failure Analysis Of Prosthetic Retaining Screws After Long‐Term Use In Vivo. Part 2: Metallurgical And Microhardness Analysis, Youssef S. Al Jabbari, Raymond Fournelle, Gerald J. Ziebert, Jeffrey M. Toth, Anthony Iacopino
Biomedical Engineering Faculty Research and Publications
Abstract
Purpose: This study involved testing and analyzing multiple retrieved prosthetic retaining screws after long‐term use in vivo to: (1) detect manufacturing defects that could affect in‐service behavior; (2) characterize the microstructure and alloy composition; and (3) further characterize the wear mechanism of the screw threads.
Materials and Methods: Two new (control) screws from Nobel Biocare (NB) and 18 used (in service 18–120 months) retaining screws [12 from NB and 6 from Sterngold (SG)] were: (1) metallographically examined by light microscopy and scanning electron microscopy (SEM) to determine the microstructure; (2) analyzed by energy dispersive X‐ray (EDX) microanalysis to determine …
Airway Strain During Mechanical Ventilation In An Intact Animal Model, Scott W. Sinclair, Robert C. Molthen, Steven Thomas Haworth, Christopher A. Dawson, Christopher M. Waters
Airway Strain During Mechanical Ventilation In An Intact Animal Model, Scott W. Sinclair, Robert C. Molthen, Steven Thomas Haworth, Christopher A. Dawson, Christopher M. Waters
Biomedical Engineering Faculty Research and Publications
Rationale: Mechanical ventilation with large tidal volumes causes ventilator-induced lung injury in animal models. Little direct evidence exists regarding the deformation of airways in vivo during mechanical ventilation, or in the presence of positive end-expiratory pressure (PEEP).
Objectives: To measure airway strain and to estimate airway wall tension during mechanical ventilation in an intact animal model.
Methods: Sprague-Dawley rats were anesthetized and mechanically ventilated with tidal volumes of 6, 12, and 25 cm3/kg with and without 10–cm H2O PEEP. Real-time tantalum bronchograms were obtained for each condition, using microfocal X-ray imaging. Images were …
Chronic Hypoxia-Induced Pulmonary Hypertension Does/Does Not Lead To Loss Of Pulmonary Vasculature, Marlene Rabinovitch, Naomi Chesler, Robert C. Molthen
Chronic Hypoxia-Induced Pulmonary Hypertension Does/Does Not Lead To Loss Of Pulmonary Vasculature, Marlene Rabinovitch, Naomi Chesler, Robert C. Molthen
Biomedical Engineering Faculty Research and Publications
No abstract provided.
Role Of Mitochondrial Electron Transport Complex I In Coenzyme Q1 Reduction By Intact Pulmonary Arterial Endothelial Cells And The Effect Of Hyperoxia, Marilyn P. Merker, Said H. Audi, Brian J. Lindemer, Gary S. Krenz, Robert D. Bongard
Role Of Mitochondrial Electron Transport Complex I In Coenzyme Q1 Reduction By Intact Pulmonary Arterial Endothelial Cells And The Effect Of Hyperoxia, Marilyn P. Merker, Said H. Audi, Brian J. Lindemer, Gary S. Krenz, Robert D. Bongard
Biomedical Engineering Faculty Research and Publications
The objective was to determine the impact of intact normoxic and hyperoxia-exposed (95% O(2) for 48 h) bovine pulmonary arterial endothelial cells in culture on the redox status of the coenzyme Q(10) homolog coenzyme Q(1) (CoQ(1)). When CoQ(1) (50 microM) was incubated with the cells for 30 min, its concentration in the medium decreased over time, reaching a lower level for normoxic than hyperoxia-exposed cells. The decreases in CoQ(1) concentration were associated with generation of CoQ(1) hydroquinone (CoQ(1)H(2)), wherein 3.4 times more CoQ(1)H(2) was produced in the normoxic than hyperoxia-exposed cell medium (8.2 +/- 0.3 and 2.4 +/- 0.4 microM, …
Soleus H-Reflex Excitability Changes In Response To Sinusoidal Hip Stretches In The Injured Human Spinal Cord, Maria Knikou, Brian D. Schmit, Debjani Chaudhuri, Elizabeth Kay, William Zev Rymer
Soleus H-Reflex Excitability Changes In Response To Sinusoidal Hip Stretches In The Injured Human Spinal Cord, Maria Knikou, Brian D. Schmit, Debjani Chaudhuri, Elizabeth Kay, William Zev Rymer
Biomedical Engineering Faculty Research and Publications
Imposed static hip stretches substantially modulate the soleus H-reflex in people with an intact or injured spinal cord while stretch of the hip flexors affect the walking pattern in lower vertebrates and humans. The aim of this study was to assess the effects of dynamic hip stretches on the soleus H-reflex in supine spinal cord injured (SCI) subjects. Sinusoidal movements were imposed on the right hip joint at 0.2 Hz by a Biodex system. H-reflexes from the soleus muscle were recorded as the leg moved in flexion or extension. Stimuli were sent only once in every hip movement cycle that …
Pulmonary Microvascular Injury Resulting From A Single Exposure To Low-Dose Thoracic Radiation, Q. Wu, G. Schmirler, John E. Moulder, Elizabeth R. Jacobs, Meetha Medhora, Robert C. Molthen
Pulmonary Microvascular Injury Resulting From A Single Exposure To Low-Dose Thoracic Radiation, Q. Wu, G. Schmirler, John E. Moulder, Elizabeth R. Jacobs, Meetha Medhora, Robert C. Molthen
Biomedical Engineering Faculty Research and Publications
No abstract provided.
D-4f Does Not Mitigate Key Parameters In Rat Model Of Severe Pulmonary Hypertension, Robert C. Molthen, Shelley Baumgardt, K. A. Pritchard Jr
D-4f Does Not Mitigate Key Parameters In Rat Model Of Severe Pulmonary Hypertension, Robert C. Molthen, Shelley Baumgardt, K. A. Pritchard Jr
Biomedical Engineering Faculty Research and Publications
No abstract provided.
Design And Validation Of A Mr-Compatible Pneumatic Manipulandum, Aaron J. Suminski, Janice L. Zimbelman, Robert A. Scheidt
Design And Validation Of A Mr-Compatible Pneumatic Manipulandum, Aaron J. Suminski, Janice L. Zimbelman, Robert A. Scheidt
Biomedical Engineering Faculty Research and Publications
The combination of functional MR imaging and novel robotic tools may provide unique opportunities to probe the neural systems underlying motor control and learning. Here, we describe the design and validation of a MR-compatible, 1 degree-of-freedom pneumatic manipulandum along with experiments demonstrating its safety and efficacy. We first validated the robot's ability to apply computer-controlled loads about the wrist, demonstrating that it possesses sufficient bandwidth to simulate torsional spring-like loads during point-to-point flexion movements. Next, we verified the MR-compatibility of the device by imaging a head phantom during robot operation. We observed no systematic differences in two measures of MRI …