Open Access. Powered by Scholars. Published by Universities.®
Biomedical Engineering and Bioengineering Commons™
Open Access. Powered by Scholars. Published by Universities.®
- Discipline
-
- Medicine and Health Sciences (4)
- Physical Sciences and Mathematics (4)
- Physical Therapy (4)
- Rehabilitation and Therapy (4)
- Mathematics (3)
-
- Vision Science (3)
- Biomechanics and Biotransport (2)
- Electrical and Computer Engineering (2)
- Mechanical Engineering (2)
- Bioelectrical and Neuroengineering (1)
- Bioimaging and Biomedical Optics (1)
- Biological Engineering (1)
- Biological and Chemical Physics (1)
- Biomechanical Engineering (1)
- Computer Sciences (1)
- Education (1)
- Physics (1)
- Psychology (1)
- Science and Mathematics Education (1)
- Social and Behavioral Sciences (1)
- Statistics and Probability (1)
- Keyword
-
- Biomechanics (15)
- Gait (15)
- Rehabilitation (14)
- Stroke (14)
- Spinal cord injury (12)
-
- Adaptive optics (10)
- Computed tomography (10)
- Diffusion tensor imaging (10)
- FMRI (10)
- Kinematics (9)
- Locomotion (9)
- Mitochondria (9)
- Motor control (9)
- Proprioception (9)
- Heart (8)
- EEG (7)
- Hemodynamics (7)
- Human (7)
- Hypertension (7)
- Lung (7)
- Micro-CT (7)
- Restenosis (7)
- Upper extremity (7)
- Active or adaptive optics (6)
- Finite element analysis (6)
- Hyperoxia (6)
- Magnetic resonance imaging (6)
- Mathematical modeling (6)
- Osteogenesis imperfecta (6)
- Rat (6)
- Publication Year
Articles 241 - 270 of 604
Full-Text Articles in Biomedical Engineering and Bioengineering
Reply To “Perception Of Lower Extremity Loading In Stroke”, Virginia W. Chu, T. George Hornby, Brian D. Schmit
Reply To “Perception Of Lower Extremity Loading In Stroke”, Virginia W. Chu, T. George Hornby, Brian D. Schmit
Biomedical Engineering Faculty Research and Publications
No abstract provided.
Tactile Proprioceptive Input In Robotic Rehabilitation After Stroke, Emmanouil Tzorakoleftherakis, Maria C. Bengston, Ferdinando A. Mussa-Ivaldi, Robert A. Scheidt, Todd D. Murphey
Tactile Proprioceptive Input In Robotic Rehabilitation After Stroke, Emmanouil Tzorakoleftherakis, Maria C. Bengston, Ferdinando A. Mussa-Ivaldi, Robert A. Scheidt, Todd D. Murphey
Biomedical Engineering Faculty Research and Publications
Stroke can lead to loss or impairment of somatosensory sensation (i.e. proprioception), that reduces functional control of limb movements. Here we examine the possibility of providing artificial feedback to make up for lost sensory information following stroke. However, it is not clear whether this kind of sensory substitution is even possible due to stroke-related loss of central processing pathways that subserve somatosensation. In this paper we address this issue in a small cohort of stroke survivors using a tracking task that emulates many activities of daily living. Artificial proprioceptive information was provided to the subjects in the form of vibrotactile …
Clinical Correlates Of High Cervical Fractional Anisotropy In Acute Cervical Spinal Cord Injury, Aditya Vedantam, Gerald Eckardt, Marjorie C. Wang, Brian D. Schmit, Shekar N. Kurpad
Clinical Correlates Of High Cervical Fractional Anisotropy In Acute Cervical Spinal Cord Injury, Aditya Vedantam, Gerald Eckardt, Marjorie C. Wang, Brian D. Schmit, Shekar N. Kurpad
Biomedical Engineering Faculty Research and Publications
Objective: Fractional anisotropy (FA) of the high cervical cord (C1-C2), rostral to the injury site, correlates with upper limb function in patients with chronic cervical spinal cord injury (SCI). In acute cervical SCI, this relationship has not been investigated. The objective of this study was to identify functional correlates of FA of the high cervical cord in a series of patients with acute cervical SCI.
Methods: Traumatic cervical SCI patients who underwent presurgical cervical spine diffusion tensor imaging at our institution were reviewed for this study. FA of the whole cord as well as the lateralcorticospinal tracts (CSTs) was calculated …
Sagittal Subtalar And Talocrural Joint Assessment With Weight-Bearing Fluoroscopy During Barefoot Ambulation, Ben Mchenry, Emily L. Exten, Jason Long, Brian Law, Richard Marks, Gerald F. Harris
Sagittal Subtalar And Talocrural Joint Assessment With Weight-Bearing Fluoroscopy During Barefoot Ambulation, Ben Mchenry, Emily L. Exten, Jason Long, Brian Law, Richard Marks, Gerald F. Harris
Biomedical Engineering Faculty Research and Publications
Background: Identifying talar position during ambulation has proved difficult as the talus lacks palpable landmarks for skin marker placement and more invasive methodologies such as bone pins are not practical for most clinical subjects. A fluoroscopic motion system was used to track the talus and calcaneus, allowing kinematic analysis of the talocrural and subtalar joints.
Methods: Thirteen male subjects (mean age 22.9 ± 3.0 years) previously screened for normal gait were tested. A fluoroscopy unit was used to collect images at 120 fps during stance. Sagittal motion of the talocrural and subtalar joints were analyzed.
Results: The intersubject mean and …
Cardiovascular Magnetic Resonance Imaging-Based Computational Fluid Dynamics/Fluid-Structure Interaction Pilot Study To Detect Early Vascular Changes In Pediatric Patients With Type 1 Diabetes, Margaret M. Samyn, Ronak Jashwant Dholakia, Hongfeng Wang, Jennifer Co-Vu, Ke Yan, Michael E. Widlansky, John F. Ladisa Jr., Pippa Simpson, Ramin Alemzadeh
Cardiovascular Magnetic Resonance Imaging-Based Computational Fluid Dynamics/Fluid-Structure Interaction Pilot Study To Detect Early Vascular Changes In Pediatric Patients With Type 1 Diabetes, Margaret M. Samyn, Ronak Jashwant Dholakia, Hongfeng Wang, Jennifer Co-Vu, Ke Yan, Michael E. Widlansky, John F. Ladisa Jr., Pippa Simpson, Ramin Alemzadeh
Biomedical Engineering Faculty Research and Publications
We hypothesized that pediatric patients with type 1 diabetes have cardiac magnetic resonance (CMR) detectable differences in thoracic aortic wall properties and hemodynamics leading to significant local differences in indices of wall shear stress, when compared with age-matched control subjects without diabetes. Pediatric patients with type 1 diabetes were recruited from Children’s Hospital of Wisconsin and compared with controls. All underwent morning CMR scanning, 4-limb blood pressure, brachial artery reactivity testing, and venipuncture. Patient-specific computational fluid dynamics modeling with fluid–structure interaction, based on CMR data, determined regional time-averaged wall shear stress (TAWSS) and oscillatory shear index (OSI). Twenty type 1 …
Diffusion Imaging In The Rat Cervical Spinal Cord, Elizabeth Zakszewski, Brian D. Schmit, Shekar N. Kurpad, Matthew D. Budde
Diffusion Imaging In The Rat Cervical Spinal Cord, Elizabeth Zakszewski, Brian D. Schmit, Shekar N. Kurpad, Matthew D. Budde
Biomedical Engineering Faculty Research and Publications
Magnetic resonance imaging (MRI) is the state of the art approach for assessing the status of the spinal cord noninvasively, and can be used as a diagnostic and prognostic tool in cases of disease or injury. Diffusion weighted imaging (DWI), is sensitive to the thermal motion of water molecules and allows for inferences of tissue microstructure. This report describes a protocol to acquire and analyze DWI of the rat cervical spinal cord on a small-bore animal system. It demonstrates an imaging setup for the live anesthetized animal and recommends a DWI acquisition protocol for high-quality imaging, which includes stabilization of …
Temporal Evolution Of Both Premotor And Motor Cortical Tuning Properties Reflect Changes In Limb Biomechanics, Aaron J. Suminski, Philip Mardoum, Timothy P. Lillicrap, Nicholas G. Hatsopoulos
Temporal Evolution Of Both Premotor And Motor Cortical Tuning Properties Reflect Changes In Limb Biomechanics, Aaron J. Suminski, Philip Mardoum, Timothy P. Lillicrap, Nicholas G. Hatsopoulos
Biomedical Engineering Faculty Research and Publications
A prevailing theory in the cortical control of limb movement posits that premotor cortex initiates a high-level motor plan that is transformed by the primary motor cortex (MI) into a low-level motor command to be executed. This theory implies that the premotor cortex is shielded from the motor periphery and therefore its activity should not represent the low-level features of movement. Contrary to this theory, we show that both dorsal (PMd) and ventral premotor (PMv) cortices exhibit population-level tuning properties that reflect the biomechanical properties of the periphery similar to those observed in M1. We recorded single-unit activity from M1, …
Differential Effects Of Buffer Ph On Ca2+-Induced Ros Emission With Inhibited Mitochondrial Complexes I And Iii, Daniel P. Lindsay, Amadou K. S. Camara, David F. Stowe, Mohammed Aldakkak, Ryan Lubbe
Differential Effects Of Buffer Ph On Ca2+-Induced Ros Emission With Inhibited Mitochondrial Complexes I And Iii, Daniel P. Lindsay, Amadou K. S. Camara, David F. Stowe, Mohammed Aldakkak, Ryan Lubbe
Biomedical Engineering Faculty Research and Publications
Excessive mitochondrial reactive oxygen species (ROS) emission is a critical component in the etiology of ischemic injury. Complex I and complex III of the electron transport chain are considered the primary sources of ROS emission during cardiac ischemia and reperfusion (IR) injury. Several factors modulate ischemic ROS emission, such as an increase in extra-matrix Ca2+, a decrease in extra-matrix pH, and a change in substrate utilization. Here we examined the combined effects of these factors on ROS emission from respiratory complexes I and III under conditions of simulated IR injury. Guinea pig heart mitochondria were suspended in experimental …
Immersive Visualization For Enhanced Computational Fluid Dynamics Analysis, David Quam, Timothy J. Gundert, Laura M. Ellwein, Christopher E. Larkee, Paul Hayden, Raymond Q. Migrino, Hiromasa Otake, John F. Ladisa
Immersive Visualization For Enhanced Computational Fluid Dynamics Analysis, David Quam, Timothy J. Gundert, Laura M. Ellwein, Christopher E. Larkee, Paul Hayden, Raymond Q. Migrino, Hiromasa Otake, John F. Ladisa
Biomedical Engineering Faculty Research and Publications
Modern biomedical computer simulations produce spatiotemporal results that are often viewed at a single point in time on standard 2D displays. An immersive visualization environment (IVE) with 3D stereoscopic capability can mitigate some shortcomings of 2D displays via improved depth cues and active movement to further appreciate the spatial localization of imaging data with temporal computational fluid dynamics (CFD) results. We present a semi-automatic workflow for the import, processing, rendering, and stereoscopic visualization of high resolution, patient-specific imaging data, and CFD results in an IVE. Versatility of the workflow is highlighted with current clinical sequelae known to be influenced by …
The Feasibility Of Imaging Myocardial Ischemic/Reperfusion Injury Using 99mTc-Labeled Duramycin In A Porcine Model, Lei Wang, Feng Wang, Wei Fang, Steven E. Johnson, Said H. Audi, Michael Zimmer, Thomas A. Holly, Daniel C. Lee, Bao Zhu, Haibo Zhu, Ming Zhao
The Feasibility Of Imaging Myocardial Ischemic/Reperfusion Injury Using 99mTc-Labeled Duramycin In A Porcine Model, Lei Wang, Feng Wang, Wei Fang, Steven E. Johnson, Said H. Audi, Michael Zimmer, Thomas A. Holly, Daniel C. Lee, Bao Zhu, Haibo Zhu, Ming Zhao
Biomedical Engineering Faculty Research and Publications
When pathologically externalized, phosphatidylethanolamine (PE) is a potential surrogate marker for detecting tissue injuries. 99mTc-labeled duramycin is a peptide-based imaging agent that binds PE with high affinity and specificity. The goal of the current study was to investigate the clearance kinetics of 99mTc-labeled duramycin in a large animal model (normal pigs) and to assess its uptake in the heart using a pig model of myocardial ischemia–reperfusion injury.
Methods
The clearance and distribution of intravenously injected 99mTc-duramycin were characterized in sham-operated animals (n = 5). In a closed chest model of myocardial ischemia, coronary occlusion was induced …
Perception Of Lower Extremity Loads In Stroke Survivors, Virginia W. Chu, T. George Hornby, Brian D. Schmit
Perception Of Lower Extremity Loads In Stroke Survivors, Virginia W. Chu, T. George Hornby, Brian D. Schmit
Biomedical Engineering Faculty Research and Publications
Objective: This study aimed to improve our understanding of static and dynamic lower extremity sensory perception and the impact of sensory impairments on the control of walking in stroke survivors.
Methods: Using a custom, real-time unloading system, we tested load perception at heel strike, mid stance and push off in 10 stroke survivors and compared their performance to 10 age-matched and 5 young adult control subjects. Dynamic load perception was based on a judgment of which leg was bearing more load, which was altered on a step by step basis. We also examined lower extremity static load perception, coordination, proprioception, …
The Effects Of Extending The Spectral Information Acquired By A Photon-Counting Detector For Spectral Ct, Taly Gilat Schmidt, Kevin C. Zimmerman, Emil Y. Sidky
The Effects Of Extending The Spectral Information Acquired By A Photon-Counting Detector For Spectral Ct, Taly Gilat Schmidt, Kevin C. Zimmerman, Emil Y. Sidky
Biomedical Engineering Faculty Research and Publications
Photon-counting x-ray detectors with pulse-height analysis provide spectral information that may improve material decomposition and contrast-to-noise ratio (CNR) in CT images. The number of energy measurements that can be acquired simultaneously on a detector pixel is equal to the number of comparator channels. Some spectral CT designs have a limited number of comparator channels, due to the complexity of readout electronics. The spectral information could be extended by changing the comparator threshold levels over time, sub pixels, or view angle. However, acquiring more energy measurements than comparator channels increases the noise and/or dose, due to differences in noise correlations across …
Experimental Comparison Of Empirical Material Decomposition Methods For Spectral Ct, Kevin C. Zimmerman, Taly Gilat Schmidt
Experimental Comparison Of Empirical Material Decomposition Methods For Spectral Ct, Kevin C. Zimmerman, Taly Gilat Schmidt
Biomedical Engineering Faculty Research and Publications
Material composition can be estimated from spectral information acquired using photon counting x-ray detectors with pulse height analysis. Non-ideal effects in photon counting x-ray detectors such as charge-sharing, k-escape, and pulse-pileup distort the detected spectrum, which can cause material decomposition errors. This work compared the performance of two empirical decomposition methods: a neural network estimator and a linearized maximum likelihood estimator with correction (A-table method). The two investigated methods differ in how they model the nonlinear relationship between the spectral measurements and material decomposition estimates. The bias and standard deviation of material decomposition estimates were compared for the two methods, …
Evaluation Of Pediatric Manual Wheelchair Mobility Using Advanced Biomechanical Methods, Brooke A. Slavens, Alyssa J. Schnorenberg, Christine M. Aurit, Adam Graf, Joseph J. Krzak, Kathryn Reiners, Lawrence C. Vogel, Gerald F. Harris
Evaluation Of Pediatric Manual Wheelchair Mobility Using Advanced Biomechanical Methods, Brooke A. Slavens, Alyssa J. Schnorenberg, Christine M. Aurit, Adam Graf, Joseph J. Krzak, Kathryn Reiners, Lawrence C. Vogel, Gerald F. Harris
Biomedical Engineering Faculty Research and Publications
There is minimal research of upper extremity joint dynamics during pediatric wheelchair mobility despite the large number of children using manual wheelchairs. Special concern arises with the pediatric population, particularly in regard to the longer duration of wheelchair use, joint integrity, participation and community integration, and transitional care into adulthood. This study seeks to provide evaluation methods for characterizing the biomechanics of wheelchair use by children with spinal cord injury (SCI). Twelve subjects with SCI underwent motion analysis while they propelled their wheelchair at a self-selected speed and propulsion pattern. Upper extremity joint kinematics, forces, and moments were computed using …
Technical Note: Phantom Study To Evaluate The Dose And Image Quality Effects Of A Computed Tomography Organ-Based Tube Current Modulation Technique, Diksha Gandhi, Dominic J. Crotty, Grant M. Stevens, Taly Gilat Schmidt
Technical Note: Phantom Study To Evaluate The Dose And Image Quality Effects Of A Computed Tomography Organ-Based Tube Current Modulation Technique, Diksha Gandhi, Dominic J. Crotty, Grant M. Stevens, Taly Gilat Schmidt
Biomedical Engineering Faculty Research and Publications
Purpose
This technical note quantifies the dose and image quality performance of a clinically available organ-dose-based tube current modulation (ODM) technique, using experimental and simulation phantom studies. The investigated ODM implementation reduces the tube current for the anterior source positions, without increasing current for posterior positions, although such an approach was also evaluated for comparison.
Methods
Axial CT scans at 120 kV were performed on head and chest phantoms on an ODM-equipped scanner (Optima CT660, GE Healthcare, Chalfont St. Giles, England). Dosimeters quantified dose to breast, lung, heart, spine, eye lens, and brain regions for ODM and 3D-modulation (SmartmA) settings. …
Critical Changes In Cortical Neuronal Interactions In Anesthetized And Awake Rats, Anthony G. Hudetz, Jeannette A. Vizuete, Siveshigan Pillay, Kristina M. Ropella
Critical Changes In Cortical Neuronal Interactions In Anesthetized And Awake Rats, Anthony G. Hudetz, Jeannette A. Vizuete, Siveshigan Pillay, Kristina M. Ropella
Biomedical Engineering Faculty Research and Publications
Background: Neuronal interactions are fundamental for information processing, cognition, and consciousness. Anesthetics reduce spontaneous cortical activity; however, neuronal reactivity to sensory stimuli is often preserved or augmented. How sensory stimulus–related neuronal interactions change under anesthesia has not been elucidated. In this study, the authors investigated the visual stimulus–related cortical neuronal interactions during stepwise emergence from desflurane anesthesia.
Methods: Parallel spike trains were recorded with 64-contact extracellular microelectrode arrays from the primary visual cortex of chronically instrumented, unrestrained rats (N = 6) at 8, 6, 4, and 2% desflurane anesthesia and wakefulness. Light flashes were delivered to the retina …
A Portable, Low-Cost Wheelchair Ergometer Design Based On A Mathematical Model Of Pediatric Wheelchair Dynamics, Jacob R. Rammer, Susan A. Riedel, Gerald F. Harris
A Portable, Low-Cost Wheelchair Ergometer Design Based On A Mathematical Model Of Pediatric Wheelchair Dynamics, Jacob R. Rammer, Susan A. Riedel, Gerald F. Harris
Biomedical Engineering Faculty Research and Publications
Evaluation and training of wheelchair propulsion improves efficiency and prevents orthopaedic injury in pediatric manual wheelchair users. Ergometers allow static propulsion and emulate typical conditions. Currently available ergometers have deficiencies that limit their use in motion analysis. A new ergometer is developed and evaluated based on a model of wheelchair inertial dynamics that eliminates these deficiencies. This makes integrated motion analysis of wheelchair propulsion in current community, home, and international outreach efforts possible.
Virtual Capstone Design Teams: Preparing For Global Innovation (Journal Article), Jay R. Goldberg, Susannah Howe
Virtual Capstone Design Teams: Preparing For Global Innovation (Journal Article), Jay R. Goldberg, Susannah Howe
Biomedical Engineering Faculty Research and Publications
Global innovation requires collaboration between groups of people located in different parts of the world, and is a growing trend in industry. Virtual teams are often used to manage new product development projects. These teams are similar to traditional teams but are geographically separated and rely heavily on virtual methods of communication (email, Skype, teleconferencing, etc.) instead of regular face-to-face meetings. Experience working as a member of a virtual capstone design team can help prepare students for this growing trend. To begin preparing students for work on virtual teams in industry, we co-advised two virtual capstone design projects with students …
Recent Developments In Osteogenesis Imperfecta, Joseph L. Shaker, Carolyne Albert, Jessica M. Fritz, Gerald F. Harris
Recent Developments In Osteogenesis Imperfecta, Joseph L. Shaker, Carolyne Albert, Jessica M. Fritz, Gerald F. Harris
Biomedical Engineering Faculty Research and Publications
Osteogenesis imperfecta (OI) is an uncommon genetic bone disease associated with brittle bones and fractures in children and adults. Although OI is most commonly associated with mutations of the genes for type I collagen, many other genes (some associated with type I collagen processing) have now been identified. The genetics of OI and advances in our understanding of the biomechanical properties of OI bone are reviewed in this article. Treatment includes physiotherapy, fall prevention, and sometimes orthopedic procedures. In this brief review, we will also discuss current understanding of pharmacologic therapies for treatment of OI.
Kinematic Foot Types In Youth With Equinovarus Secondary To Hemiplegia, Joseph Krzak, Daniel M. Corcos, Diane L. Damiano, Adam Graf, Donald Hedeker, Peter A. Smith, Gerald F. Harris
Kinematic Foot Types In Youth With Equinovarus Secondary To Hemiplegia, Joseph Krzak, Daniel M. Corcos, Diane L. Damiano, Adam Graf, Donald Hedeker, Peter A. Smith, Gerald F. Harris
Biomedical Engineering Faculty Research and Publications
Background
Elevated kinematic variability of the foot and ankle segments exists during gait among individuals with equinovarus secondary to hemiplegic cerebral palsy (CP). Clinicians have previously addressed such variability by developing classification schemes to identify subgroups of individuals based on their kinematics.
Objective
To identify kinematic subgroups among youth with equinovarus secondary to CP using 3-dimensional multi-segment foot and ankle kinematics during locomotion as inputs for principal component analysis (PCA), and K-means cluster analysis.
Methods
In a single assessment session, multi-segment foot and ankle kinematics using the Milwaukee Foot Model (MFM) were collected in 24 children/adolescents with equinovarus and …
Guest Editorial: The 2014 Capstone Design Conference, Steven Beyerlein, Jay R. Goldberg, Susannah Howe, Scott Palo, Renee Rogge, R. Keith Stanfill
Guest Editorial: The 2014 Capstone Design Conference, Steven Beyerlein, Jay R. Goldberg, Susannah Howe, Scott Palo, Renee Rogge, R. Keith Stanfill
Biomedical Engineering Faculty Research and Publications
The goal of the 2014 Capstone Design Conference held in Columbus, OH was to build upon the success of three previous conferences (2007 and 2010 in Boulder, CO, and 2012 in Champaign, IL) and expand the community of educators, students, and industry members engaged in discussing, analyzing, and improving capstone design education. Sessions at the 2014 Capstone Design Conference were designed for vibrant sharing of ideas and experiences across the capstone community via interactive panel sessions, poster session socials, and hands-on workshops. This editorial discusses conference planning, structure, and feedback. Technical papers that follow in this issue document scholarship surrounding …
Large-Scale Spatiotemporal Spike Patterning Consistent With Wave Propagation In Motor Cortex, Kazutaka Takahashi, Sanggyun Kim, Todd P. Coleman, Kevin A. Brown, Aaron J. Suminski, Matthew D. Best, Nicholas G. Hatsopoulos
Large-Scale Spatiotemporal Spike Patterning Consistent With Wave Propagation In Motor Cortex, Kazutaka Takahashi, Sanggyun Kim, Todd P. Coleman, Kevin A. Brown, Aaron J. Suminski, Matthew D. Best, Nicholas G. Hatsopoulos
Biomedical Engineering Faculty Research and Publications
Aggregate signals in cortex are known to be spatiotemporally organized as propagating waves across the cortical surface, but it remains unclear whether the same is true for spiking activity in individual neurons. Furthermore, the functional interactions between cortical neurons are well documented but their spatial arrangement on the cortical surface has been largely ignored. Here we use a functional network analysis to demonstrate that a subset of motor cortical neurons in non-human primates spatially coordinate their spiking activity in a manner that closely matches wave propagation measured in the beta oscillatory band of the local field potential. We also demonstrate …
In Vivo Detection Of Hyperoxia-Induced Pulmonary Endothelial Cell Death Using 99mTc-Duramycin, Said H. Audi, Elizabeth R. Jacobs, Ming Zhao, David L. Roerig, Steven T. Haworth, Anne V. Clough
In Vivo Detection Of Hyperoxia-Induced Pulmonary Endothelial Cell Death Using 99mTc-Duramycin, Said H. Audi, Elizabeth R. Jacobs, Ming Zhao, David L. Roerig, Steven T. Haworth, Anne V. Clough
Biomedical Engineering Faculty Research and Publications
Introduction
99mTc-duramycin, DU, is a SPECT biomarker of tissue injury identifying cell death. The objective of this study is to investigate the potential of DU imaging to quantify capillary endothelial cell death in rat lung injury resulting from hyperoxia exposure as a model of acute lung injury.
Methods
Rats were exposed to room air (normoxic) or > 98% O2 for 48 or 60 hours. DU was injected i.v. in anesthetized rats, scintigraphy images were acquired at steady-state, and lung DU uptake was quantified from the images. Post-mortem, the lungs were removed for histological studies. Sequential lung sections were immunostained …
Intention Tremor And Deficits Of Sensory Feedback Control In Multiple Sclerosis: A Pilot Study, Megan Heenan, Robert A. Scheidt, Douglas Woo, Scott A. Beardsley
Intention Tremor And Deficits Of Sensory Feedback Control In Multiple Sclerosis: A Pilot Study, Megan Heenan, Robert A. Scheidt, Douglas Woo, Scott A. Beardsley
Biomedical Engineering Faculty Research and Publications
Background
Intention tremor and dysmetria are leading causes of upper extremity disability in Multiple Sclerosis (MS). The development of effective therapies to reduce tremor and dysmetria is hampered by insufficient understanding of how the distributed, multi-focal lesions associated with MS impact sensorimotor control in the brain. Here we describe a systems-level approach to characterizing sensorimotor control and use this approach to examine how sensory and motor processes are differentially impacted by MS.
Methods
Eight subjects with MS and eight age- and gender-matched healthy control subjects performed visually-guided flexion/extension tasks about the elbow to characterize a sensory feedback control model that …
Reversible Blockade Of Complex I Or Inhibition Of Pkcβ Reduces Activation And Mitochondria Translocation Of P66Shc To Preserve Cardiac Function After Ischemia, Meiying Yang, David F. Stowe, Kenechukwu B. Udoh, James S. Heisner, Amadou K.S. Camara
Reversible Blockade Of Complex I Or Inhibition Of Pkcβ Reduces Activation And Mitochondria Translocation Of P66Shc To Preserve Cardiac Function After Ischemia, Meiying Yang, David F. Stowe, Kenechukwu B. Udoh, James S. Heisner, Amadou K.S. Camara
Biomedical Engineering Faculty Research and Publications
Aim
Excess mitochondrial reactive oxygen species (mROS) play a vital role in cardiac ischemia reperfusion (IR) injury. P66Shc, a splice variant of the ShcA adaptor protein family, enhances mROS production by oxidizing reduced cytochrome c to yield H2O2. Ablation of p66Shc protects against IR injury, but it is unknown if and when p66Shc is activated during cardiac ischemia and/or reperfusion and if attenuating complex I electron transfer or deactivating PKCβ alters p66Shc activation during IR is associated with cardioprotection.
Methods
Isolated guinea pig hearts were perfused and subjected to increasing periods …
Within-Socket Myoelectric Prediction Of Continuous Ankle Kinematics For Control Of A Powered Transtibial Prosthesis, Samuel Farmer, M. Barbara Silver-Thorn, Philip A. Voglewede, Scott A. Beardsley
Within-Socket Myoelectric Prediction Of Continuous Ankle Kinematics For Control Of A Powered Transtibial Prosthesis, Samuel Farmer, M. Barbara Silver-Thorn, Philip A. Voglewede, Scott A. Beardsley
Biomedical Engineering Faculty Research and Publications
Objective. Powered robotic prostheses create a need for natural-feeling user interfaces and robust control schemes. Here, we examined the ability of a nonlinear autoregressive model to continuously map the kinematics of a transtibial prosthesis and electromyographic (EMG) activity recorded within socket to the future estimates of the prosthetic ankle angle in three transtibial amputees. Approach. Model performance was examined across subjects during level treadmill ambulation as a function of the size of the EMG sampling window and the temporal 'prediction' interval between the EMG/kinematic input and the model's estimate of future ankle angle to characterize the trade-off between model error, …
Entrepreneurship In Capstone Design: Has The Pendulum Swung Too Far?, Jay R. Goldberg
Entrepreneurship In Capstone Design: Has The Pendulum Swung Too Far?, Jay R. Goldberg
Biomedical Engineering Faculty Research and Publications
The author supports entrepreneurial education for all interested students, but not at the expense of design education. He thinks we should develop business literacy among all of our students to prepare them for work in start-ups and established medical device companies, and provide opportunities for interested students to add entrepreneurial literacy to better prepare them to create new companies, either upon graduation or later in their careers. Capstone design courses should focus on helping students develop solid design skills and providing opportunities to apply the analytical tools learned in previous courses. Students should be encouraged, not required, to consider commercializing …
Reduced Diaphyseal Strength Associated With High Intracortical Vascular Porosity Within Long Bones Of Children With Osteogenesis Imperfecta, Carolyne Albert, John Jameson, Peter Smith, Gerald F. Harris
Reduced Diaphyseal Strength Associated With High Intracortical Vascular Porosity Within Long Bones Of Children With Osteogenesis Imperfecta, Carolyne Albert, John Jameson, Peter Smith, Gerald F. Harris
Biomedical Engineering Faculty Research and Publications
Osteogenesis imperfecta is a genetic disorder resulting in bone fragility. The mechanisms behind this fragility are not well understood. In addition to characteristic bone mass deficiencies, research suggests that bone material properties are compromised in individuals with this disorder. However, little data exists regarding bone properties beyond the microstructural scale in individuals with this disorder.
Specimens were obtained from long bone diaphyses of nine children with osteogenesis imperfecta during routine osteotomy procedures. Small rectangular beams, oriented longitudinally and transversely to the diaphyseal axis, were machined from these specimens and elastic modulus, yield strength, and maximum strength were measured in three-point …
Upper Extremity Biomechanics Of Children With Spinal Cord Injury During Wheelchair Mobility, Alyssa J. Schnorenberg, Brooke A. Slavens, Adam Graf, Joseph J. Krzak, Lawrence C. Vogel, Gerald F. Harris
Upper Extremity Biomechanics Of Children With Spinal Cord Injury During Wheelchair Mobility, Alyssa J. Schnorenberg, Brooke A. Slavens, Adam Graf, Joseph J. Krzak, Lawrence C. Vogel, Gerald F. Harris
Biomedical Engineering Faculty Research and Publications
While much work is being done evaluating the upper extremity joint dynamics of adult manual wheelchair propulsion, limited work has examined the pediatric population of manual wheelchair users. Our group used a custom pediatric biomechanical model to characterize the upper extremity joint dynamics of 12 children and adolescents with spinal cord injury (SCI) during wheelchair propulsion. Results show that loading appears to agree with that of adult manual wheelchair users, with the highest loading primarily seen at the glenohumeral joint. This is concerning due to the increased time of wheelchair use in the pediatric population and the impact of this …
Non-Common Path Aberration Correction In An Adaptive Optics Scanning Ophthalmoscope, Yusufu N. Sulai, Alfredo Dubra
Non-Common Path Aberration Correction In An Adaptive Optics Scanning Ophthalmoscope, Yusufu N. Sulai, Alfredo Dubra
Biomedical Engineering Faculty Research and Publications
The correction of non-common path aberrations (NCPAs) between the imaging and wavefront sensing channel in a confocal scanning adaptive optics ophthalmoscope is demonstrated. NCPA correction is achieved by maximizing an image sharpness metric while the confocal detection aperture is temporarily removed, effectively minimizing the monochromatic aberrations in the illumination path of the imaging channel. Comparison of NCPA estimated using zonal and modal orthogonal wavefront corrector bases provided wavefronts that differ by ~λ/20 in root-mean-squared (~λ/30 standard deviation). Sequential insertion of a cylindrical lens in the illumination and light collection paths of the imaging channel was used to compare image resolution …