Articles 181 - 210 of 278

Full-Text Articles in Biomedical Engineering and Bioengineering

Esem Analysis Of Mice Femurs With Varying Sost Levels, Patrick K. Mcclay Jun 2012

Esem Analysis Of Mice Femurs With Varying Sost Levels, Patrick K. Mcclay

Biomedical Engineering

This project’s goal was to analyze the properties of the cortical femur on 100 mice bones from Lawrence Livermore National Laboratory. Analysis was limited to imaging which determined the ratio of bone volume to total volume (BV/TV) and osteocyte lacunae density. Mice were altered to knock out their SOST gene: a negative regulator of bone formation. Twelve groups were created to differentiate their treatment, duration, and phenotype. Transgenic (TG) mice had an overexpression of the SOST gene: they carried a bacterial artificial chromosome. Mice with limb defects (DEF) were the offspring of two TG mice and carried twice the amount …


Hydraulically Driven Mechanical Representation Of A Biological System, Andrea Argouarch, Michael Mceachern, Brandon Parham Jun 2012

Hydraulically Driven Mechanical Representation Of A Biological System, Andrea Argouarch, Michael Mceachern, Brandon Parham

Biomedical Engineering

No abstract provided.


Development Of A Blood Flow Measurement Protocol Using Particle Image Velocimetry, Jennifer Chi-Ying Go Jun 2012

Development Of A Blood Flow Measurement Protocol Using Particle Image Velocimetry, Jennifer Chi-Ying Go

Biomedical Engineering

Peripheral Arterial Occlusive Disease (PAOD) is an acquired inflammatory disease where a peripheral artery becomes occluded due to the buildup of atherosclerotic plaques. In patients that possess collateral arteries, an occlusion can lead to shear induced outward remodeling, arteriogenesis, of these collaterals, partially restoring blood flow. However, newly remodeled collaterals exhibit reduced functional vasodilation, which may impair normal activity, such as ambulation. To model chronic ischemia and arteriogenesis in collaterals, a femoral artery ligation in a murine hindlimb is commonly performed. Previous efforts by our group involved measurements of collateral artery diameter to assess the impact of arteriogenesis on functional …


Development And Characterization Of Plga And Eptfe Blood Vessel Mimics Using Gene Expression Analysis, Michael Gibbons, Sarah Ur Jun 2012

Development And Characterization Of Plga And Eptfe Blood Vessel Mimics Using Gene Expression Analysis, Michael Gibbons, Sarah Ur

Biomedical Engineering

Tissue engineered blood vessels (TEBV’s) have the potential to act not only as a replacement for diseased vessels, but also as a testing platform for intravascular devices such as stents. To this end, the goal of this study was to develop protocols for the construction of TEBV’s composed of human vascular cells and either expanded polytetrafluoroethylene (ePTFE) or poly-lactic-co-glycolic acid (PLGA), as well as a protocol for gene expression in those TEBV’s. Initial experiments involved only human umbilical vein endothelial cells (HUVEC’s), but after low cell confluency and spreading in single-sodded vessels a second cell type, human umbilical vein smooth …


Evaluation Of Decellularization Procedures For Porcine Arteries, Charles Clapp Apr 2012

Evaluation Of Decellularization Procedures For Porcine Arteries, Charles Clapp

Biomedical Engineering

Coronary artery disease has become the leading cause of death in the United States, with over 425,000 deaths in 2006. Stenting has evolved into the preferred preventative technique for myocardial infarction by opening up an occluded artery, due to its low invasiveness compared to the alternative of coronary artery bypass grafting. Bare metal stents have been improved by coating with anti-proliferative drugs to advance their effects, but even drug eluting stents still have a risk of restenosis, thrombus formation, and necessary revascularization. Continual advancement in stent design necessitates faster, effective pre-clinical evaluation techniques. Kristen Cardinal, Ph.D., developed the blood vessel …


A Novel In-House Design Of A Bioreactor For The Modeling Of An In Vitro Blood Brain Barrier Model, Ian Mahaffey Jan 2012

A Novel In-House Design Of A Bioreactor For The Modeling Of An In Vitro Blood Brain Barrier Model, Ian Mahaffey

Biomedical Engineering

The blood brain barrier is the protector of the central nervous system and a physical barrier that functions to regulate the substances that can pass in and out of the brain; it is the function and integrity of this system that keeps the homeostasis of the central nervous system. Yet this shield against foreign invaders in the blood also prevents drugs designed for treatment of various ailments of the central nervous system from reaching their target in the brain. Developing drugs that can pass through this barrier, and understanding it’s function has become an area of increasing interest. Many researchers …


Effect Of Size Reduction Parameters In Pharmaceutical Manufacturing Process, Brian Breneman Dec 2011

Effect Of Size Reduction Parameters In Pharmaceutical Manufacturing Process, Brian Breneman

Biomedical Engineering

Within pharmaceutical manufacturing, size reduction is one of the most extensively used and vital unit operations. Size reduction in tablet production is achieved primarily through milling procedures, which allows for attaining product uniformity, optimizing product solubility, and improving bioavailability. Additionally, powders with a narrow range of size distribution can obviate problems in downstream processing as pertains to blending, compression, and coating as well as improve drug performance1. The purpose this study was to characterize the effect of various size reduction parameters as a result of the pharmaceutical milling process on a lactose wet granulation formulation and chemically active …


Improved Manufacturing Methods Of Bovine Femur Samples For Ultrasonic Testing And Assessment Of Materials Through Contract Angle Measurement, Kevin Mathew Lopez Galang Sep 2011

Improved Manufacturing Methods Of Bovine Femur Samples For Ultrasonic Testing And Assessment Of Materials Through Contract Angle Measurement, Kevin Mathew Lopez Galang

Biomedical Engineering

At California Polytechnic State University of San Luis Obispo (Cal Poly), the Biomedical Engineering department (BMED) requires its students to take the course listed as “BMED 420: Principles of Biomaterial Designs.” BMED 420 has a required laboratory section every week throughout the duration of the course that is meant to be a supplemental tool for learning. During the lab sections, students perform experiments and exercises that are currently being implemented in the industry. Despite accuracy of the methods and experiments relative to their use in the industry, there is always room for improvement. The objective of this project will illustrate …


Impaired Resistance Artery Reactivity Following Arteriogenesis, Michael (Mike) Machado Sep 2011

Impaired Resistance Artery Reactivity Following Arteriogenesis, Michael (Mike) Machado

Biomedical Engineering

No abstract provided.


The 4+1 Program And Distance Learning Meeting Objectives And Outcomes, Daniel W. Walsh, Lanny Griffin, Robert S. Crockett Jun 2011

The 4+1 Program And Distance Learning Meeting Objectives And Outcomes, Daniel W. Walsh, Lanny Griffin, Robert S. Crockett

Biomedical Engineering

Graduate engineering education is a key to the maintenance of U.S. competitiveness in the world market. The world has been an extremely dynamic engine during the last fifty years, and we have witnessed a dramatic change in the world order. The change has been evolutionary in many cases, but events in Eastern Europe, the Middle East and the erstwhile Soviet Union are only slightly less cataclysmic than the Second World War. In a world where strength is measured in terms of the financial resource, the technological ability and the intellectual capability of a populace Japan, China, India and the EEC …


An Inexpensive Method For Creating Paste To Be Used In Paper-Based Microfluidic Devices, Kirra Marie Sankey Jun 2011

An Inexpensive Method For Creating Paste To Be Used In Paper-Based Microfluidic Devices, Kirra Marie Sankey

Biomedical Engineering

Microfluidic devices are diagnostic tools that are small, portable, and inexpensive. This makes them ideally suited for resource-limited settings. To construct a 3D device, each layer of patterned paper is stacked using double-sided tape with holes corresponding to the pattern. It is necessary to have a paste to fill the holes in the tape and provide a medium for the fluid to wick through. The powder used to make the paste is very expensive and must be bought in bulk (an estimated $1121 - $1231), so it is not convenient for the Biomedical (BMED) department to use. This project was …


Development Of An In-Vitro Hyperglycemic Tissue Engineered Blood Vessel Mimic, Brian C. Wong Jun 2011

Development Of An In-Vitro Hyperglycemic Tissue Engineered Blood Vessel Mimic, Brian C. Wong

Biomedical Engineering

No abstract provided.


Polymeric Splint And Rapid-Setting Polyurethane, Lanny Griffin, Dane Robert Jones Mar 2011

Polymeric Splint And Rapid-Setting Polyurethane, Lanny Griffin, Dane Robert Jones

Biomedical Engineering

A splint includes a first container capable of being wrapped about an item to be supported and a second container capable of containing a multiple part mixture during a mixing operation. The second container being capable of delivering the mixture into the first container, wherein the mixture hardens to form a support structure. A method for using the splint is also disclosed.


The Biomechanics Of Varied Proximal Locking Screw Configurations In A Synthetic Model Of Proximal Third Tibial Fracture Fixation, Philip R. Wolinsky, Douglas Dennis, Brett D. Crist, Shane Curtiss, Scott J. Hazelwood Mar 2011

The Biomechanics Of Varied Proximal Locking Screw Configurations In A Synthetic Model Of Proximal Third Tibial Fracture Fixation, Philip R. Wolinsky, Douglas Dennis, Brett D. Crist, Shane Curtiss, Scott J. Hazelwood

Biomedical Engineering

Objective: To determine if 1) angularly stable devices created by compressing (‘‘locking’’) proximal locking screws to intramedullary nails using end caps or compression screws or 2) increasing the number of proximal screws from two to three increases the stiffness of intramedullary constructs that stabilize proximal third tibia fractures in a nonosteopenic bone model.


Methods: Four proximal locking screw configurations were examined in a synthetic composite tibia model with a 2-cm gap simulating a comminuted proximal third tibia fracture with no bony contact: 1) two proximal screws not compressed to the nail; 2) one of two proximal screws compressed to …


Investigation Of Pmma Cement Penetration In Prepared Femoral Heads With A Longitudinal Slot For Hip Resurfacing Arthroplasty, Scott Snyder Feb 2011

Investigation Of Pmma Cement Penetration In Prepared Femoral Heads With A Longitudinal Slot For Hip Resurfacing Arthroplasty, Scott Snyder

Biomedical Engineering

Hip resurfacing arthroplasty is becoming increasingly popular in younger, active patients due to its preservation of natural biomechanics. Failure of these implants can be very traumatic and potentially life threatening. The role of cement penetration in early implant failure is not yet known, and must be investigated. This study specifically investigates the effects of a 5mm by 5mm longitudinal channel on cement penetration into the femoral head. High-density open-cell reticulated vitreous carbon foam cylinders and Huntsman Pro-cast® 20 implants based on the Birmingham Hip Resurfacing implant were used. It was determined cement penetration was increased in the area immediately surrounding …


The Effect Of Cox-2 Specific Inhibition On Direct Fracture Healing In The Rabbit Tibia, David J. Hak, Kurt S. Schulz, Behrang Khoie, Scott J. Hazelwood Jan 2011

The Effect Of Cox-2 Specific Inhibition On Direct Fracture Healing In The Rabbit Tibia, David J. Hak, Kurt S. Schulz, Behrang Khoie, Scott J. Hazelwood

Biomedical Engineering

Objective: The purpose of this study was to evaluate the effect of Cox-2 administration on direct (primary) fracture healing.

Methods: A transverse tibial osteotomy was created in adult male rabbits and rigidly fixed in compression using a 2.7-mm dynamic compression plate. Animals were randomized to receive either rofecoxib (12.5 mg orally per day) or placebo. Animals were killed at 4 weeks and fracture healing assessed by mechanical testing.

Results: There were no significant differences between the control and Cox-2 treated animals in terms of mechanical strength at 4 weeks. There was a high complication rate of peri-implant fractures …


Arteriogenesis And Ischemia Impair Functional Vasodilation In Resistance Arteries, Trevor Cardinal, Joseph S. Zhu, Kyle R. Struthers, Thomas J. Kesler, Matthew D. Yocum Jan 2011

Arteriogenesis And Ischemia Impair Functional Vasodilation In Resistance Arteries, Trevor Cardinal, Joseph S. Zhu, Kyle R. Struthers, Thomas J. Kesler, Matthew D. Yocum

Biomedical Engineering

No abstract provided.


Characterization Of Bioreactor System For Tissue Engineered Blood Vessels, Kasim Shah Jan 2011

Characterization Of Bioreactor System For Tissue Engineered Blood Vessels, Kasim Shah

Biomedical Engineering

No abstract provided.


An Investigation Of Process Parameters To Optimize The Fiber Diameter Of Electrospun Vascular Scaffolds Through Experimental Design, Steffi Wong Dec 2010

An Investigation Of Process Parameters To Optimize The Fiber Diameter Of Electrospun Vascular Scaffolds Through Experimental Design, Steffi Wong

Biomedical Engineering

No abstract provided.


Characterization And Analysis Techniques Of A Dynamic In Vitro Blood-Brain Barrier Model, Ryan Everett Woodhouse Dec 2010

Characterization And Analysis Techniques Of A Dynamic In Vitro Blood-Brain Barrier Model, Ryan Everett Woodhouse

Biomedical Engineering

The blood-brain barrier (BBB) is responsible for maintaining the sensitive environment required by the brain. Although the BBB is necessary for proper functioning of the brain, it acts as an obstacle for doctors attempting to treat neurological disease. For a drug to act upon the brain, it must first pass through the discriminating BBB. For this reason, much research has been performed in recent years in order to create an in vitro model of the BBB on which drugs targeted for the central nervous system may be tested. The main goal of this project is to create an in vitro …


Can Spr Be Used To Interrogate The Double Layer Of Nacl, Brandon Kawula Nov 2010

Can Spr Be Used To Interrogate The Double Layer Of Nacl, Brandon Kawula

Biomedical Engineering

Solutions of reagent grade salt .1, .01, .001, .0001, .00001M were run through a SPR to see if SPR had enough resolution to detect the formation of the electric double layer. We found that NaCl did in fact return a detectable signal. The signal shape seems to depend on concentration. While more study may need to be done to get definite information it looks like SPR can interrogate the double layer.


Differential Regulation Of Immature Articular Cartilage Compressive Moduli And Poisson's Ratios By In Vitro Stimulation With Igf-1 And Tgf-Β1, Gregory M. Williams, Kristin J. Dills, Christian R. Flores, Michael E. Stender, Kevin M. Stewart, Lauren M. Nelson, Albert C. Chen, Koichi Masuda, Scott J. Hazelwood, Stephen M. Klisch, Robert L. Sah Sep 2010

Differential Regulation Of Immature Articular Cartilage Compressive Moduli And Poisson's Ratios By In Vitro Stimulation With Igf-1 And Tgf-Β1, Gregory M. Williams, Kristin J. Dills, Christian R. Flores, Michael E. Stender, Kevin M. Stewart, Lauren M. Nelson, Albert C. Chen, Koichi Masuda, Scott J. Hazelwood, Stephen M. Klisch, Robert L. Sah

Biomedical Engineering

Mechanisms of articular cartilage growth and maturation have been elucidated by studying composition-function dynamics during in vivo development and in vitro culture with stimuli such as insulin-like growth factor-1 (IGF-1) and transforming growth factor-beta 1 (TGF-β1). This study tested the hypothesis that IGF-1 and TGF-β1 regulate immature cartilage compressive moduli and Poisson’s ratios in a manner consistent with known effects on tensile properties. Bovine calf articular cartilage from superficial-articular (S) and middle-growth (M) regions were analyzed fresh or following culture in medium with IGF-1 or TGF-β1. Mechanical properties in confined (CC) and unconfined (UCC) compression, cartilage matrix composition, and explant …


Immunohistochemical Mapping Of Hypoxia In Ischemic Mouse Hindlimb Skeletal Muscle, Emily Deckert Aug 2010

Immunohistochemical Mapping Of Hypoxia In Ischemic Mouse Hindlimb Skeletal Muscle, Emily Deckert

Biomedical Engineering

The study of blood vessel growth and remodeling is a complex endeavor. Hypoxia, the lack of oxygen in a tissue, is known to stimulate angiogenesis (the growth of new blood vessels), and have little effect on arteriogenesis (the enlargement of existing blood vessels). However, the role of hypoxia in vessel function is unknown, but may be determined using the results and methods developed in this experiment.

Supplied by the bloodstream, oxygen is required by all cells and tissues to remain healthy. If the bloodstream supplying a certain tissue with blood is disrupted, the tissue becomes ischemic, often leading to hypoxia. …


Development Towards A Protocol To Test For The Creation Of A “Diabetic” Environment In A Blood Vessel Mimic, Kaitlyn Kirk, Development Towards A Protocol To Test For The Creation Of A “Diabetic” Environment In A Blood Vessel Mimic Jun 2010

Development Towards A Protocol To Test For The Creation Of A “Diabetic” Environment In A Blood Vessel Mimic, Kaitlyn Kirk, Development Towards A Protocol To Test For The Creation Of A “Diabetic” Environment In A Blood Vessel Mimic

Biomedical Engineering

Diabetes mellitus affects a huge proportion of people; about 6% of the population in the US had diabetes in 2007 (16). Diabetes promotes dyslipidemia, an imbalance in the circulating levels of lipids and lipoproteins, and diabetes is one of the leading risk factors for coronary artery and peripheral vascular diseases (11, 51, 52).  There are two types of diabetes; type 1 diabetes accounts for about 10% of diagnosed cases and type 2 accounts for about 90% (11).  Diabetic patients react differently to stents and there is a great need to enhance the treatment.  The goal of this project was, and …


Locked Plate Fixation Of Osteoporotic Humeral Shaft Fractures: Are Two Locking Screws Per Segment Enough?, David J. Hak, Peter Althausen, S J. Hazelwood Apr 2010

Locked Plate Fixation Of Osteoporotic Humeral Shaft Fractures: Are Two Locking Screws Per Segment Enough?, David J. Hak, Peter Althausen, S J. Hazelwood

Biomedical Engineering

Objective: The purpose of this study was to compare the biomechanical behavior of using two versus three locking screws per bone segment in a cadaveric humerus fracture gap model.

Methods: Six matched pairs of elderly osteoporotic fresh–frozen human cadaveric humerii were used. An eight-hole locking compression plate was placed posteriorly on the humeral shaft and secured with either four or six bicortical locking screws. A 5-mm middiaphyseal gap osteotomy was created to simulate a comminuted fracture without bony contact. Specimens were tested in offset axial compression, four-point anteroposterior bending, four-point medial– lateral bending, and torsion. After the initial testing in …


Impaired Vascular Reactivity Following Chronic Ischemia In The Arteries Of The Mouse Hindlimb, Thomas (Tom) Kesler Jan 2010

Impaired Vascular Reactivity Following Chronic Ischemia In The Arteries Of The Mouse Hindlimb, Thomas (Tom) Kesler

Biomedical Engineering

Collateral dependent hyperemia is reduced following chronic ischemia, but the contribution of individual vessel reactivity is unknown. Further, it is not known what aspect of the complex ischemic injury response impacts vascular reactivity. To determine the impact of ischemia on vascular reactivity, we measured functional vasodilation in the muscular branch artery following resection of the femoral artery proximal to the muscular branch. On day-14 after surgery the diameter of the muscular branch was measured using side-stream dark field (SDF) imaging intravital microscopy. At moderate intensity skeletal muscle contraction (1mA, 200µs, 8Hz, 90sec), functional vasodilation is reduced compared to the contralateral …


Morphological Assessment Of Basic Multicellular Unit Resorption Parameters In Dogs Shows Additional Mechanisms Of Bisphosphonate Effects On Bone, Matthew R. Allen, Antonia M. Erickson, Xiang Wang, David B. Burr, R. Bruce Martin, Scott J. Hazelwood Jan 2010

Morphological Assessment Of Basic Multicellular Unit Resorption Parameters In Dogs Shows Additional Mechanisms Of Bisphosphonate Effects On Bone, Matthew R. Allen, Antonia M. Erickson, Xiang Wang, David B. Burr, R. Bruce Martin, Scott J. Hazelwood

Biomedical Engineering

Bisphosphonates (BPs) slow bone loss by reducing initiation of new basic multicellular units (BMUs). Whether or not BPs simply prevent osteoclasts from initiating new BMUs that resorb bone or also reduce the amount of bone they resorb at the BMU level is not clear. The goal of this study was to determine the effects of BPs on three morphological parameters of individual BMUs, resorption depth (Rs.De), area (Rs.Ar), and width (Rs.Wi). After 1 year of treatment with vehicle (VEH), alendronate (ALN; 0.10, 0.20, or 1.00 mg/kg/day), or risedronate (RIS; 0.05, 0.10, or 0.50 mg/kg/day), resorption cavity morphology was assessed in …


Impaired Vascular Reactivity Following Chronic Ischemia In The Arteries Of The Mouse Hindlimb, Trevor Cardinal, Thomas J. Kesler, Matthew D. Yocum, Tyler S. Smith, Nolan M. Mott Jan 2010

Impaired Vascular Reactivity Following Chronic Ischemia In The Arteries Of The Mouse Hindlimb, Trevor Cardinal, Thomas J. Kesler, Matthew D. Yocum, Tyler S. Smith, Nolan M. Mott

Biomedical Engineering

No abstract provided.


Material Properties Are Related To Stress Fracture Callus And Porosity Of Cortical Bone Tissue At Affected And Unaffected Sites, Rachel C. Entwistle,, Sara C. Sammons, Robert F. Bigley, Scott J. Hazelwood, David P. Fyhrie, Jeffery C. Gibeling, Susan M. Stover Oct 2009

Material Properties Are Related To Stress Fracture Callus And Porosity Of Cortical Bone Tissue At Affected And Unaffected Sites, Rachel C. Entwistle,, Sara C. Sammons, Robert F. Bigley, Scott J. Hazelwood, David P. Fyhrie, Jeffery C. Gibeling, Susan M. Stover

Biomedical Engineering

Stress fractures are overuse injuries of bone that affect elite athletes and military recruits. One response of cortical bone to stress fracture is to lay down periosteal callus. The objectives of this study were to determine if material properties are different among bones with different stages of stress fracture callus, at both a callus site and at a distal site. Cortical specimens were mechanically tested to determine their stress–strain response. Material property differences were examined using nonparametric and regression analyses. At the callus site, material properties were low during the earliest stages of callus, higher with increasing callus maturity, but …


Compliance Calibration For Fracture Testing Of Anisotropic Biological Materials, J. A. Creel, S. M. Stover, R. B. Martin, D. P. Fyhrie, S. J. Hazelwood, J. C. Gibeling Oct 2009

Compliance Calibration For Fracture Testing Of Anisotropic Biological Materials, J. A. Creel, S. M. Stover, R. B. Martin, D. P. Fyhrie, S. J. Hazelwood, J. C. Gibeling

Biomedical Engineering

The compliance technique has been used to monitor crack length during fracture and fatigue testing of materials. Difficulties arise when this technique is applied to anisotropic biological materials such as bone. In this tutorial, two different methods of analyzing compliance calibration data are described: the standard ASTM method and a new approach developed by the authors specifically for anisotropic materials. An example is given showing how data from equine cortical bone can be analyzed. In this example, calibration tests were conducted on thirty-six three point bend specimens machined from the middiaphysis of six pairs of equine third metacarpal bones. Cracks …