Open Access. Powered by Scholars. Published by Universities.®
Biomedical Engineering and Bioengineering Commons™
Open Access. Powered by Scholars. Published by Universities.®
- Discipline
-
- Biomedical Devices and Instrumentation (27)
- Electrical and Computer Engineering (27)
- Mechanical Engineering (18)
- Medicine and Health Sciences (16)
- Computer Engineering (11)
-
- Biomaterials (10)
- Medical Specialties (10)
- Biomedical (9)
- Manufacturing (9)
- Signal Processing (9)
- Biomechanics and Biotransport (8)
- Other Biomedical Engineering and Bioengineering (8)
- Surgery (7)
- Biomechanical Engineering (6)
- Electrical and Electronics (6)
- Life Sciences (6)
- Analytical, Diagnostic and Therapeutic Techniques and Equipment (5)
- Bioelectrical and Neuroengineering (5)
- Controls and Control Theory (5)
- Molecular, Cellular, and Tissue Engineering (5)
- Physical Sciences and Mathematics (5)
- Biological Engineering (4)
- Orthopedics (4)
- Systems and Communications (4)
- Acoustics, Dynamics, and Controls (3)
- Bioimaging and Biomedical Optics (3)
- Biology and Biomimetic Materials (3)
- Communication Sciences and Disorders (3)
- Keyword
-
- Ultrasound (9)
- Bone (7)
- Computational fluid dynamics (6)
- Wall shear stress (6)
- Bioengineering (5)
-
- Coronary stent (5)
- Restenosis (5)
- Acoustic Emission (4)
- Angioplasty (4)
- Electro-larynx (4)
- Impact (4)
- In-stent restenosis (4)
- Intelligibility (4)
- Laryngectomy (4)
- Numerical (4)
- Surgery (4)
- Accelerometer (3)
- Concussion (3)
- Cutting (3)
- Heat (3)
- Medical (3)
- Microdamage (3)
- Sawing (3)
- Stent (3)
- Ablation (2)
- Acoustic (2)
- Augmentative Communication (2)
- Automated tracking (2)
- Biopotential measurement (2)
- Breast cancer (2)
- Publication Year
- Publication
- Publication Type
- File Type
Articles 61 - 90 of 152
Full-Text Articles in Biomedical Engineering and Bioengineering
Investigation Of A New Material For Heart Valve Tissue Engineering, Claire Brougham, Gerard Cooney, Thomas Flanagan, Stefan Jockenhoevel, Fergal O'Brien
Investigation Of A New Material For Heart Valve Tissue Engineering, Claire Brougham, Gerard Cooney, Thomas Flanagan, Stefan Jockenhoevel, Fergal O'Brien
Conference Papers
No abstract provided.
A Wireless And Digital Electrode Bus Topology For Biopotential Measurement, Mark Nolan, Edward Burke, Eugene Coyle
A Wireless And Digital Electrode Bus Topology For Biopotential Measurement, Mark Nolan, Edward Burke, Eugene Coyle
Conference Papers
The conventional biopotential measurement configuration utilises long lead wires which connect measuring electrodes to signal conditioning circuitry. The majority of bioelectric signals that are measured from the human body have a tiny signal amplitude (5µV-5mV range) and thus any interference that is induced on the lead wires can have a detrimental effect on the original signal. In this paper, we present an alternative configuration, in which digitisation occurs on the electrode, potentially providing enhanced signal measurement as well as significant benefits in terms of the simplification of the physical interconnections between electrodes. Multiple electrodes are combined to form a digital …
The Presence Of Regional Accents In Electrolarynx Speech And The Resultant Effect On Overall Intelligibility., Brian Madden, Eugene Coyle
The Presence Of Regional Accents In Electrolarynx Speech And The Resultant Effect On Overall Intelligibility., Brian Madden, Eugene Coyle
Conference Papers
During voiced speech, the larynx provides quasi-periodic acoustic excitation of the vocal tract. In most electrolarynxes, mechanical vibrations are produced by a linear electromechanical actuator, the armature of which percusses against a metal or plastic plate at a frequency within the range of glottal excitation. In this paper, a phonological analysis of a section of results from an online perceptual intelligibility test was performed which compared speech produced using a novel hands-free electrolarynx and a commercially available electrolarynx. A portion of the test consisted of a closed-set format containing a selection of four sets of four random CVC audio samples …
Investigation Of A New Material For Heart Valve Tissue Engineering, Claire Brougham, Nian Shen, Allison Cudsworth, Thomas Flanagan, Stefan Jockenhoevel, Fergal O'Brien
Investigation Of A New Material For Heart Valve Tissue Engineering, Claire Brougham, Nian Shen, Allison Cudsworth, Thomas Flanagan, Stefan Jockenhoevel, Fergal O'Brien
Conference Papers
No abstract provided.
Increased Susceptibility Of Arterial Tissue To Wire Perforation With The Application Of High Frequency Mechanical Vibrations, Mark Wylie, Garrett Mcguinness, Graham Gavin
Increased Susceptibility Of Arterial Tissue To Wire Perforation With The Application Of High Frequency Mechanical Vibrations, Mark Wylie, Garrett Mcguinness, Graham Gavin
Articles
High frequency mechanical vibrations (20–50 kHz), delivered via small diameter flexible wire waveguides represent a minimally invasive technology for the treatment of chronic total occlusions (CTOs) and in other tissue ablation applications. Tissue disruption is reported to be caused by repetitive mechanical contact and cavitation. This work focuses on the effects of vibrating wire waveguides in contact with arterial tissue. An apparatus with clinically relevant parameters was used, characterized as operating at 22.5 kHz and delivering amplitudes of vibration of 17.8 - 34.3 µm (acoustic intensity, ISATA: 1.03 - 3.83 W/cm2) via 1.0 mm diameter waveguides. …
Soft Tissue Cutting With Ultrasonic Mechanical Waveguides, Mark Wylie, Garrett Mcguinness, Graham Gavin
Soft Tissue Cutting With Ultrasonic Mechanical Waveguides, Mark Wylie, Garrett Mcguinness, Graham Gavin
Conference Papers
The use of ultrasonic vibrations transmitted via small diameter wire waveguides represents a technology that has potential for minimally invasive procedures in surgery. This form of energy delivery results in distal tip mechanical vibrations with amplitudes of vibration of up to 50 μm and at frequencies between 20-50 kHz commonly reported. This energy can then be used by micro-cutting surgical tools and end effectors for a range of applications such as bone cutting, cement removal in joint revision surgery and soft tissue cutting. One particular application which has gained regulatory approval in recent years is in the area of cardiovascular …
Impact Isolation Of Training Shoes, Nicci Daly, Stephen Tiernan
Impact Isolation Of Training Shoes, Nicci Daly, Stephen Tiernan
Conference Papers
ABSTRACT The increase in popularity of physical activities from fun runs to competitive marathons has lead to a huge industry in sports footwear, which is now worth $20bn annually. There is a resultant increase in injuries, largely due to the repeated and prolonged nature of the impact forces experienced by the leg. Clinical data indicates that the knee is the most common site of running related injury, followed by the lower leg and foot. The complexity of the ankle structure means that injuries are acute and the success rates of replacements are very low. Therefore research in this area is …
Effects Of Β-Cyclodextrin As A Capping Agent On The Antibacterial Properties Of Agnps, Swarna Jaiswal, Brendan Duffy, Patrick Mchale
Effects Of Β-Cyclodextrin As A Capping Agent On The Antibacterial Properties Of Agnps, Swarna Jaiswal, Brendan Duffy, Patrick Mchale
Conference Papers
No abstract provided.
Comparing Fbg And Pcf Force Sensors In A Laparoscopic Smart Surgical Scissor Instrument, Dean Callaghan, Ginu Rajan, Mark Mcgrath, Eugene Coyle, Yuliya Semenova, Gerald Farrell
Comparing Fbg And Pcf Force Sensors In A Laparoscopic Smart Surgical Scissor Instrument, Dean Callaghan, Ginu Rajan, Mark Mcgrath, Eugene Coyle, Yuliya Semenova, Gerald Farrell
Conference Papers
This paper presents a sensorized laparoscopic surgical scissor instrument using both a fiber Bragg grating (FBG) and a tapered photonic crystal fiber (PCF) as force sensors. The sensors are located on the blades for the detection of interaction forces generated between the instrument and tissue during cutting. The force sensitivity of each sensorized blade is examined. Results show that the scissor blade-PCF sensor arrangement outperforms the blade with the FBG during static loading calibration experimentation. Moreover, experiments show that the PCF based arrangement is less sensitive to temperature effects than its FBG counterpart. This negates the need for additional temperature …
Surgical Cutting And Ablation By Energy Based Devices: Principles And Applications, Garrett Mcguinness, Joseph A. Mcgeough, Graham Gavin, Brendan O'Daly
Surgical Cutting And Ablation By Energy Based Devices: Principles And Applications, Garrett Mcguinness, Joseph A. Mcgeough, Graham Gavin, Brendan O'Daly
Conference Papers
Advances in ultrasound, radiofrequency, and water jet systems are facilitating their increased use in new medical ablation or cutting applications in fields as diverse as cardiology, orthopaedics, ophthalmology, dermatology, oncology and neurosurgery. These methods involve controlled alteration or destruction of tissues via the application of thermal, electrical or kinetic energy. This market segment is characterised by advanced devices capable of heating or cooling tissue from -200°C to 400°C, or inducing vibrations of up to 60 kHz to cause tissue damage. The medical conditions targeted primarily pertain to chronic and age-related diseases, but elective and cosmetic procedures are also addressed. Medical …
Radio-Frequency Breast Cancer Imaging Results For A Simplified Cylindrical Phantom, Giuseppe Ruvio, Raffaele Solimene, Antonietta D'Alterio, Max Ammann, Rocco Pierri
Radio-Frequency Breast Cancer Imaging Results For A Simplified Cylindrical Phantom, Giuseppe Ruvio, Raffaele Solimene, Antonietta D'Alterio, Max Ammann, Rocco Pierri
Conference Papers
Microwave imaging is a pervasive research field and
is useful in numerous applicative diagnostic noninvasive contexts. This paper focuses on two aspects. First, we perform a numerical investigation to assess the role played by fundamental parameters (i.e. number of sensors, operating frequency bandwidth) on cancer detection. To this end, a simplified cylindrical phantom probed by ideal two-dimensional dipoles (i.e. infinitely long along the axis of invariance) is considered. Second, in order to focus on the role of the antennas, we analyze, still by numerical simulations and for a simplified breast model, how performances vary when a realistic antenna is adopted.
Characterising 3d Soft Tissue Features On Joint Surfaces, Colm O'Kane
Characterising 3d Soft Tissue Features On Joint Surfaces, Colm O'Kane
Conference Papers
A crucial aspect of orthopaedic implant design is the prediction of surgical outcomes when the shape of a bone is necessarily altered by the addition of the implant. Matching native kinematics as closely as possible is generally considered a core aim of joint replacement surgery. The overall hypothesis behind this research is that soft tissue geometry, including cartilage thickness distribution and ligament attachment sites, influences kinematics in the knee joint. In order to enable investigation of possible links between geometry and kinematics, the ability to characterise the shape variation of the soft tissue relative to the underlying bony geometry must …
Novel Bioelectrical Measurement Using A Digital Biopotential Monode, Mark Nolan, Edward Burke, Eugene Coyle
Novel Bioelectrical Measurement Using A Digital Biopotential Monode, Mark Nolan, Edward Burke, Eugene Coyle
Conference Papers
In conventional biopotential recording, two or more electrodes are placed on the body. A unipolar lead records the time-varying electrical potential at a single point (relative to a reference potential) via one signal electrode. A bipolar lead records the time-varying potential difference between two points via two signal electrodes. In each case, the signal electrodes are connected to high impedance amplifier inputs, while an additional electrode provides a low-impedance path between the amplifier and human subject. Bipolar leads are usually preferred since interference appearing at both signal electrodes can be eliminated using an instrumentation amplifier with high CMRR. A drawback …
Intelligibility Of Electrolarynx Speech Using A Novel Hands-Free Actuator, Brian Madden, Mark Nolan, Ted Burke, James Condron, Eugene Coyle
Intelligibility Of Electrolarynx Speech Using A Novel Hands-Free Actuator, Brian Madden, Mark Nolan, Ted Burke, James Condron, Eugene Coyle
Conference Papers
During voiced speech, the larynx provides quasi-periodic acoustic excitation of the vocal tract. In most electrolarynxes, mechanical vibrations are produced by a linear electromechanical actuator, the armature of which percusses against a metal or plastic plate at a frequency within the range of glottal excitation. In this paper, the intelligibility of speech produced using a novel hands-free actuator is compared to speech produced using a conventional electrolarynx. Two able-bodied speakers (one male, one female) performed a closed response test containing 28 monosyllabic words, once using a conventional electrolarynx and a second time using the novel design. The resulting audio recordings …
Augmented Control Of A Hands-Free Electrolarynx, Brian Madden, James Condron, Eugene Coyle
Augmented Control Of A Hands-Free Electrolarynx, Brian Madden, James Condron, Eugene Coyle
Conference Papers
During voiced speech, the larynx acts as the sound source, providing a quasi-periodic excitation of the vocal tract. Following a total laryngectomy, some people speak using an electrolarynx which employs an electromechanical actuator to perform the excitatory function of the absent larynx. Drawbacks of conventional electrolarynx designs include the monotonic sound emitted, the need for a free-hand to operate the device, and the difficulty experienced by many laryngectomees in adapting to its use. One improvement to the electrolarynx, which clinicians and users frequently suggest, is the provision of a convenient hands-free control facility. This would allow more natural use of …
High Power, Low Frequency Ultrasound: Meniscal Tissue Interaction And Ablation Characteristics, Brendan O'Daly, Edmund Morris, Graham Gavin, Conor Keane, John O Byrne, Garrett Mcguinness
High Power, Low Frequency Ultrasound: Meniscal Tissue Interaction And Ablation Characteristics, Brendan O'Daly, Edmund Morris, Graham Gavin, Conor Keane, John O Byrne, Garrett Mcguinness
Articles
Abstract—This study evaluates high power low frequency ultrasound transmitted via a flat vibrating probe tip as an alternative technology for meniscal debridement in the bovine knee. An experimental force controlled testing rig was constructed using a 20 kHz ultrasonic probe suspended vertically from a load cell. Effect of variation in amplitude of distal tip displacement (242–494 mm peak-peak) settings and force (2.5–4.5 N) on tissue removal rate (TRR) and penetration rate (PR) for 52 bovine meniscus samples was analyzed. Temperature elevation in residual meniscus was measured by embedded thermocouples and histologic analysis. As amplitude or force increases, there is a …
Characterising 3d Soft Tissue Features On Joint Surfaces, Colm O'Kane
Characterising 3d Soft Tissue Features On Joint Surfaces, Colm O'Kane
Other resources
A crucial aspect of orthopaedic implant design is the prediction of surgical outcomes when the shape of a bone is necessarily altered by the addition of the implant. Matching native kinematics as closely as possible is generally considered a core aim of joint replacement surgery. The overall hypothesis behind this research is that soft tissue geometry, including cartilage thickness distribution and ligament attachment sites, influences kinematics in the knee joint. In order to enable investigation of possible links between geometry and kinematics, the ability to characterise the shape variation of the soft tissue relative to the underlying bony geometry must …
Magnetic Resonance Image Processing Using Levy, Jonathan Blackledge, Matthew D. Blackledge
Magnetic Resonance Image Processing Using Levy, Jonathan Blackledge, Matthew D. Blackledge
Conference papers
We consider the physical nature of the self-diffusion of water molecules in tissue and explore how (Nuclear) Magnetic Resonance (MR) imaging may be used as a means of measuring the rate of diffusion in vivo. A discussion is presented on how these techniques may be implemented as a non-invasive means of assessing the response of tumours to novel therapeutics including some of the basic advantages and disadvan- tages when compared to other methods. The physical basis and mathematical models for diffusion are considered together with models for the distribution of the diffusion co- efficient including a Lévy distributed model. Using …
Perforation Of Arterial Tissue Using Kilohertz Frequency Ultrasound Delivered Via Wire Waveguides, Mark Wylie, Garrett Mcguinness, Graham Gavin
Perforation Of Arterial Tissue Using Kilohertz Frequency Ultrasound Delivered Via Wire Waveguides, Mark Wylie, Garrett Mcguinness, Graham Gavin
Conference Papers
An emerging technology proposes the use of low frequency-high power ultrasound transmitted via wire waveguides for the disruption and ablation of atherosclerotic lesions, more specifically advanced fibrous or calcified plaques such as chronic total occlusions (CTO). This energy delivery selectively ablates rigid diseased tissue by means of direct mechanical contact, cavitation and other forces generated by the intense dynamic pressure fields generated.
The first clinical device using this energy delivery was granted FDA approval in 2007 [1] for the ablation of CTOs and most research to date has focused on ablation and disruption of hard, fibrous or calcified tissues [2]. …
Arterial Tissue Perforation Using Ultrasonically Vibrating Wire Waveguides, Mark Wylie
Arterial Tissue Perforation Using Ultrasonically Vibrating Wire Waveguides, Mark Wylie
Doctoral
Chronic Total Occlusions (CTOs) are fibrous and calcified atherosclerotic lesions which completely occlude the artery. They are difficult to treat with standard dilation procedures as they cannot be traversed easily. Their treatment is also associated with a high risk of arterial perforation. Low frequency ultrasonic vibrations delivered via wire waveguides represent a minimally invasive treatment for CTOs and other tissue ablation applications. These devices typically operate at 20–50 kHz delivering wire waveguide distal tip amplitudes of vibration of 0-60 μm. The diseased tissue is ablated or disrupted by repetitive direct mechanical contact and cavitation. This research assesses the susceptibility of …
In-Silico Hyperthermia Performance Of A Near-Field Patch Antenna At Various Positions On A Human Body Model, Sergio Curto, Terrence See, Patrick Mcevoy, Max Ammann, Zhi Ning Chen
In-Silico Hyperthermia Performance Of A Near-Field Patch Antenna At Various Positions On A Human Body Model, Sergio Curto, Terrence See, Patrick Mcevoy, Max Ammann, Zhi Ning Chen
Articles
A compact patch applicator designed to enhance targeted energy coupling at 434 MHz is a key enabler for sensitizing temperature increments in body regions containing superficial tumours. A detailed FDTD body model is used to explore simulated RF coupling and temperature increments for typical clinical conditions. The antenna impedance matching, specific absorption rate and thermal distribution parameters are evaluated to identify applied performance outcomes. The analysis reveals physiological-RF coupling patterns for an optimised closely-coupled single element applicator.
On Improving Electrooculogram-Based Computer Mouse Systems: The Accelerometer Trigger, Johnalan Keegan, Edward Burke, James Condron, Eugene Coyle
On Improving Electrooculogram-Based Computer Mouse Systems: The Accelerometer Trigger, Johnalan Keegan, Edward Burke, James Condron, Eugene Coyle
Conference Papers
Eye tracking is a well-established method of computer control for profoundly paralysed people (Anson et al., 2002). Cameras are commonly used to track eye movements (Morimoto et al., 2005) but one alternative is the bioelectrical signal known as the electrooculogram (EOG). There are some EOG mouse control systems that facilitate the use of GUI applications, but certain actions, which are straightforward using a conventional mouse, remain impossible. Unless the eyes are tracking a target, they move in saccades (jumps), making it impossible to voluntarily trace out smooth trajectories with one's gaze, as would be required to draw a smooth curve. …
Blood Vessel Diameter Estimation System Using Active Contours, Jane Courtney, Ana Tizon
Blood Vessel Diameter Estimation System Using Active Contours, Jane Courtney, Ana Tizon
Conference Papers
The study and analysis of blood vessel geometry has become the basis of medical applications related to early diagnosis and effective monitoring of therapies in vascular diseases. This paper presents a new method to trace the outline of blood vessels from imperfect images and extract useful information about their dimensions in an automated manner. The system consists of a segmentation procedure that uses two Active Contours to detect blood vessel boundaries and a novel approach to measure blood vessel diameters directly as the distance between two points. We have succeeded in designing and implementing an automated, robust, measurement method that …
Production Of Anatomical Models From Ct Scan Data, John Brennan
Production Of Anatomical Models From Ct Scan Data, John Brennan
Other resources
Rapid Prototyping (RP) technology was conceived in the mid 1980s as a method of manufacturing models, particularly to support the design of new motor vehicles. However as early as 1995 the potential to take data from medical scanners and generate models of patient anatomy to assist clinicians plan complex surgical procedures had been recognised, albeit by researchers rather than the mainstream medical industry. Over the last 15 years the production of preoperative planning models has increased dramatically and moreover, the potential to produce customised implants recognised.
Although RP technology is now established in the medical field work is still on …
A Monocular Marker-Free Gait Measurement System, Jane Courtney, Annraoi M. De Paor
A Monocular Marker-Free Gait Measurement System, Jane Courtney, Annraoi M. De Paor
Articles
This paper presents a new, user-friendly, portable motion capture and gait analysis system for capturing and analyzing human gait, designed as a telemedicine tool to monitor remotely the progress of patients through treatment. The system requires minimal user input and simple single-camera filming (which can be acquired from a basic webcam) making it very accessible to nontechnical, nonclinical personnel. This system can allow gait studies to acquire a much larger data set and allow trained gait analysts to focus their skills on the interpretation phase of gait analysis. The design uses a novel motion capture method derived from spatiotemporal segmentation …
Intelligibility Of Electrolarynx Speech Using A Novel Actuator, Brian Madden, Mark Nolan, Ted Burke, James Condron, Eugene Coyle
Intelligibility Of Electrolarynx Speech Using A Novel Actuator, Brian Madden, Mark Nolan, Ted Burke, James Condron, Eugene Coyle
Conference Papers
During voiced speech, the larynx provides quasi-periodic acoustic excitation of the vocal tract. Following a laryngectomy, some people speak using an electrolarynx which replaces the excitatory function of the absent larynx. Drawbacks of conventional electrolarynx designs include the buzzing monotonic sound emitted, the need for a free hand to operate the device, and difficulty experienced by many laryngectomees in adapting to its use. Despite these shortcomings, it remains the preferred method of speech rehabilitation for a substantial minority of laryngectomees. In most electrolarynxes, mechanical vibrations are produced by a linear electromechanical actuator, the armature of which percusses against a metal …
A Full-Range, Multi-Variable, Cfd-Based Methodology To Identify Abnormal Near-Wall Hemodynamics In A Stented Coronary Artery, Jonathan Murphy, Fergal Boyle
A Full-Range, Multi-Variable, Cfd-Based Methodology To Identify Abnormal Near-Wall Hemodynamics In A Stented Coronary Artery, Jonathan Murphy, Fergal Boyle
Articles
The benefit of coronary stent implantation is reduced by excessive intimal hyperplasia which re-narrows the artery and the prevention of which is still a primary concern for clinicians. Abnormal hemodynamics create non-physiological viscous stress on the artery wall, one of the root causes of intimal hyperplasia following stent implantation. A methodology to comprehensively evaluate the viscous stress on the artery wall following stent implantation would be useful to evaluate a stent’s hemodynamic performance. The proposed methodology employs 3D computational fluid dynamics, the variables wall shear stress (WSS), WSS gradient (WSSG), WSS angle gradient (WSSAG) and a statistical analysis to evaluate …
Antenna Development For Radio Frequency Hyperthermia Applications, Sergio Curto
Antenna Development For Radio Frequency Hyperthermia Applications, Sergio Curto
Doctoral
This thesis deals with the design steps, development and validation of an applicator for radio frequency hyperthermia cancer therapy. An applicator design to enhance targeted energy coupling is a key enabler for preferential temperature increments in tumour regions. A single-element, near-field approach requires a miniaturised solution, that addresses ergonomic needs and is tolerant to patient anatomy. The antenna war-field rriodality and the high-dielectric patient loading introduce significant analytical and computational resource challenges. The antenna input impedance has to be sufficiently insensitive to in-band resonant cletuning and the fields in the tissue can he targeted to selected areas in the patient. …
A Linear Finite Element Acoustic Fluid-Structure Model Of Ultrasonic Angioplasty In Vivo, Mark Wylie, Garrett Mcguinness, Graham Gavin
A Linear Finite Element Acoustic Fluid-Structure Model Of Ultrasonic Angioplasty In Vivo, Mark Wylie, Garrett Mcguinness, Graham Gavin
Articles
The delivery of high-power ultrasonic energy via small diameter wire waveguides represents a new alternative therapy for the treatment of chronic totally occluded arteries (CTOs). This type of energy manifests itself as a mechanical vibration at the distal-tip of the waveguide with amplitudes of vibration up to 60 µm and at frequencies of 20- 50 kHz. Disruption of diseased tissue is reported to be a result of direct mechanical ablation, cavitation, pressure components and acoustic streaming and that ablation was only evident above the cavitation threshold. This work presents a linear finite element acoustic fluid-structure model of an ultrasonic angioplasty …
Links With Canada Benefit Dit Prosthesis Research, Colm O'Kane
Links With Canada Benefit Dit Prosthesis Research, Colm O'Kane
Articles
Colm O’Kane is a lecturer in the School of Manufacturing and Design Engineering and a member of the DIT Biomedical Device and Assistive Technology Research Group. He is currently engaged in PhD research in the field of knee prosthesis development, focused on developing optimised strategies for partial and total joint replacements used in treatment of osteoarthritis of the knee joint. This article is an account of a research scholarship sponsored by the CHC Helicopter Corporation and awarded by the Ireland Canada University Foundation (ICUF). This foundation awards annual scholarships for research visits between Ireland and Canada with the aspiration of …