Open Access. Powered by Scholars. Published by Universities.®
Biomedical Engineering and Bioengineering Commons™
Open Access. Powered by Scholars. Published by Universities.®
- Discipline
-
- Chemical Engineering (31)
- Biomechanics and Biotransport (12)
- Mechanical Engineering (12)
- Bioimaging and Biomedical Optics (11)
- Biomedical Devices and Instrumentation (7)
-
- Physical Sciences and Mathematics (7)
- Biochemical and Biomolecular Engineering (6)
- Biomechanical Engineering (6)
- Biomaterials (4)
- Chemistry (4)
- Civil and Environmental Engineering (4)
- Life Sciences (4)
- Physics (4)
- Transport Phenomena (4)
- Molecular, Cellular, and Tissue Engineering (3)
- Biology (2)
- Civil Engineering (2)
- Electrical and Computer Engineering (2)
- Biotechnology (1)
- Computer Engineering (1)
- Diseases (1)
- Education (1)
- Environmental Engineering (1)
- Mathematics (1)
- Medicine and Health Sciences (1)
- Other Biomedical Engineering and Bioengineering (1)
- Pharmacology, Toxicology and Environmental Health (1)
- Plant Sciences (1)
- Keyword
-
- Biomedical Engineering (23)
- Biomechanics (13)
- Biomedical engineering (9)
- Biomedical Research (8)
- Chemical Engineering (7)
-
- Elastin (7)
- Polypeptides (7)
- Magnetic resonance imaging (6)
- Tissue engineering (6)
- Chemical engineering (5)
- MRI (5)
- Mechanical Engineering (5)
- Algae (4)
- Antifreeze proteins (4)
- Biomass energy -- Research (4)
- Bone regeneration (4)
- Brain -- Magnetic resonance imaging (4)
- Diffusion (4)
- Engineering (4)
- Microalgae -- Biotechnology (4)
- Polymers (4)
- Scenedesmus (4)
- Biomass energy (3)
- Blood flow (3)
- Directional solidification (3)
- Electronic books. local (3)
- Gravity settler (3)
- Heart -- Magnetic resonance imaging (3)
- Microelectromechanical systems (3)
- Model (3)
- Publication Year
- Publication
- Publication Type
Articles 121 - 150 of 193
Full-Text Articles in Biomedical Engineering and Bioengineering
Assessment Of Circumferential Myocardial Function Using Radial Tagged Mri, Yujaung Kim
Assessment Of Circumferential Myocardial Function Using Radial Tagged Mri, Yujaung Kim
ETD Archive
The extent of myocardial abnormalities is related to cardiac disease. The assessment of myocardial function of the left ventricular (LV) described by the LV myocardial deformation plays an important role to understand the effects of cardiovascular disease and therapeutic interventions on LV motion. Cardiac magnetic resonance imaging (CMR) is widely agreed as the most accurate noninvasive imaging modality for the assessment of left ventricular (LV) function. In addition, myocardial-tagging technique can track the myocardial deformation by labeling specific regions. Although the grid tagging is popular in cardiac research use, it has not been adopted into routine clinical examination with unreliable …
A Concept For Direct Control Of Rotary Blood Pump Speed By Inlet Pressure, Ibrahim Seven
A Concept For Direct Control Of Rotary Blood Pump Speed By Inlet Pressure, Ibrahim Seven
ETD Archive
Heart failure remains a major health problem for the world. Heart transplantation is the most effective treatment for end stage heart failure. A major problem with heart transplantation is finding adequate numbers of appropriate donors. The lack of donor numbers in the world creates a significant clinical need for blood pumping devices. The ability of ventricular assist devices to relieve the consequences of less than terminal heart failure further creates a need for assist therapy. Current new ventricular assist devices are built around continuous flow technology. These nonpulsatile assist devices have had major clinical success in relieving symptoms and increasing …
Effect Of Step Change In Growth Speed During Directional Solidification On Array Morphology Of Al-7 Wt Si Alloy, Swapna Pakiru
Effect Of Step Change In Growth Speed During Directional Solidification On Array Morphology Of Al-7 Wt Si Alloy, Swapna Pakiru
ETD Archive
No abstract provided.
Measurement Of White Matter Structure Changes In Amyotrophic Lateral Sclerosis Using Fractal Analysis, Zao Liu
ETD Archive
Amyotrophic lateral sclerosis (ALS) is recognized as a motor neuron disorder affecting the structure and function of the brain and neuromuscular system. Very little is known, however, that the nervous system degeneration is dependent on disease phenotypes of ALS. The purpose of this study was to determine the degree of brain white matter (WM) structure degeneration in four ALS patient groups characterized by their clinical signs and neuroimaging measurements. Fractal dimension (FD) of three-dimensional (3D) brain WM images was quantitatively analyzed to evaluate the WM structural complexity, including complexity levels of the WM skeleton, surface and general structures in ALS …
An Assessment Of The Accuracy Of Magnetic Resonance Phase Velocity Mapping In Turbulent Flow Through Orifices, Sahitya Pidaparthi
An Assessment Of The Accuracy Of Magnetic Resonance Phase Velocity Mapping In Turbulent Flow Through Orifices, Sahitya Pidaparthi
ETD Archive
Magnetic resonance phase velocity mapping (MRPVM) is an established clinical technique to measure blood flow. The acquired information can be used to diagnose a variety of cardiovascular disease. One of the main limitations of MRPVM is that it cannot quantify the flow under turbulent flow conditions. Such conditions develop in certain cases such as in heart valve stenosis and arterial stenosis. Specifically, heart valve stenosis is a serious disease in which the valve does not open as much as necessary for blood to pass through. As a result, the heart has to overwork to overcome the increased resistance. If untreated, …
Robotic Testing Of Proximal Tibio-Fibular Joint Kinematics For Measuring Instability Following Total Knee Arthroplasty, Wael K. Barsoum, Ho H. Lee, Trevor G. Murray, Robb Colbrunn, Alison K. Klika, S. Butler, Antonie J. Van Den Bogert
Robotic Testing Of Proximal Tibio-Fibular Joint Kinematics For Measuring Instability Following Total Knee Arthroplasty, Wael K. Barsoum, Ho H. Lee, Trevor G. Murray, Robb Colbrunn, Alison K. Klika, S. Butler, Antonie J. Van Den Bogert
Mechanical Engineering Faculty Publications
Pain secondary to instability in total knee arthroplasty (TKA) has been shown to be major cause of early failure. In this study, we focused on the effect of instability in TKA on the proximal tibio-fibular joint (PTFJ). We used a robotics model to compare the biomechanics of the PTFJ in the native knee, an appropriately balanced TKA, and an unbalanced TKA. The tibia (n = 5) was mounted to a six-degree-of-freedom force/torque sensor and the femur was moved by a robotic manipulator. Motion at the PTFJ was recorded with a high-resolution digital camera system. After establishing a neutral position, …
Personal Navigation Via High-Resolution Gait-Corrected Inertial Measurement Units, Özkan Bebek, Michael A. Suster, Srihari Rajgopal, Michael J. Fu, Xuemei Huang, M. Cenk Çavu¸So˘Glu,, Darrin J. Young, Mehran Mehregany, Antonie J. Van Den Bogert, Carlos H. Mastrangelo
Personal Navigation Via High-Resolution Gait-Corrected Inertial Measurement Units, Özkan Bebek, Michael A. Suster, Srihari Rajgopal, Michael J. Fu, Xuemei Huang, M. Cenk Çavu¸So˘Glu,, Darrin J. Young, Mehran Mehregany, Antonie J. Van Den Bogert, Carlos H. Mastrangelo
Mechanical Engineering Faculty Publications
In this paper, a personal micronavigation system that uses high-resolution gait-corrected inertial measurement units is presented. The goal of this paper is to develop a navigation system that uses secondary inertial variables, such as velocity, to enable long-term precise navigation in the absence of Global Positioning System (GPS) and beacon signals. In this scheme, measured zerovelocity duration from the ground reaction sensors is used to reset the accumulated integration errors from accelerometers and gyroscopes in position calculation. With the described system, an average position error of 4 m is achieved at the end of half-hour walks.
An Analytical Model For Rotator Cuff Repairs, A. Aurora, Jorge E. Gatica, A.J. Van Den Bogert, J. A. Mccarron, Kathleen A. Derwin
An Analytical Model For Rotator Cuff Repairs, A. Aurora, Jorge E. Gatica, A.J. Van Den Bogert, J. A. Mccarron, Kathleen A. Derwin
Chemical & Biomedical Engineering Faculty Publications
Background: Currently, natural and synthetic scaffolds are being explored as augmentation devices for rotator cuff repair. When used in this manner, these devices are believed to offer some degree of load sharing; however, no studies have quantified this effect. Furthermore, the manner in which loads on an augmented rotator cuff repair are distributed among the various components of the repair is not known, nor is the relative biomechanical importance of each component. The objectives of this study are to (1) develop quasi-static analytical models of simplified rotator cuff repairs, (2) validate the models, and (3) predict the degree of …
A Simple Apparatus For Measuring Cell Settling Velocity, Zhaowei Wang, Joanne M. Belovich
A Simple Apparatus For Measuring Cell Settling Velocity, Zhaowei Wang, Joanne M. Belovich
Chemical & Biomedical Engineering Faculty Publications
Accurate cell settling velocity determination is critical for perfusion culture using a gravity settler for cell retention. We have developed a simple apparatus (a 'settling column') for measuring settling velocity and have validated the procedure with 15-μm polystyrene particles with known physical properties. The measured settling velocity of the polystyrene particles is within 4% of the value obtained using the traditional Stokes' law approach. The settling velocities of three hybridoma cell lines were measured, resulting in up to twofold variation among cell lines, and the values decreased as the cell culture aged. The settling velocities of the nonviable cells were …
Lipids And Collagen Matrix Restrict The Hydraulic Permeability Within The Porous Compartment Of Adult Cortical Bone, Demin Wen, Caroline Androjna, Amit Vasanji, Joanne M. Belovich, Ronald J. Midura
Lipids And Collagen Matrix Restrict The Hydraulic Permeability Within The Porous Compartment Of Adult Cortical Bone, Demin Wen, Caroline Androjna, Amit Vasanji, Joanne M. Belovich, Ronald J. Midura
Chemical & Biomedical Engineering Faculty Publications
In vivo the hydraulic permeability of cortical bone influences the transport of nutrients, waste products and signaling molecules, thus influencing the metabolic functions of osteocytes and osteoblasts. In the current study two hypotheses were tested: the presence of (1) lipids and (2) collagen matrix in the porous compartment of cortical bone restricts its permeability. Our approach was to measure the radial permeability of adult canine cortical bone before and after extracting lipids with acetone-methanol, and before and after digesting collagen with bacterial collagenase. Our results showed that the permeability of adult canine cortical bone was below 4.0 × 10 …
Finite Element Modeling Of Stress Urinary Incontinence Mechanics, Thomas A. Spirka
Finite Element Modeling Of Stress Urinary Incontinence Mechanics, Thomas A. Spirka
ETD Archive
Stress urinary incontinence is characterized by the involuntary transurethral loss of urine caused by an increase in abdominal pressure in the absence of a bladder contraction that raises the vesical pressure to a level that exceeds urethral pressure. Adult women are most commonly affected by SUI which is believed to be caused in part by injuries to the pelvic floor sustained during childbirth. In spite of the large number of women affected by SUI, little is known about the mechanics associated with the maintenance of continence in women. In theory the mechanics underlying the mechanics of female continence can be …
Design, Development And Biomechanical Analysis Of Scaffolds For Augmentation Of Rotator Cuff Repairs, Amit Aurora
Design, Development And Biomechanical Analysis Of Scaffolds For Augmentation Of Rotator Cuff Repairs, Amit Aurora
ETD Archive
Rotator cuff tears are a source of debilitating pain that commonly affects more than 40 of our aging population. Despite advances in surgical treatment, the failure rate of rotator cuff repairs is as high as 20-90 . Extracellular matrix (ECM) derived scaffolds have recently been investigated as augmentation devices for rotator cuff repairs, but none has yet demonstrated both the appropriate biological and mechanical properties for mitigating re-tears and enhancing healing. This dissertation proposes to engineer the mechanical properties of allograft fascia lata in a manner that will allow its use as an augmentation device for rotator cuff repairs. This …
Surface Microtopography Modulation Of Biomaterials For Bone Tissue Engineering Applications, Eun Jung Kim
Surface Microtopography Modulation Of Biomaterials For Bone Tissue Engineering Applications, Eun Jung Kim
ETD Archive
The ultimate goal of this project is to develop a biodegradable and implantable scaffold with precise surface topographies that can provide osteoconductive stimuli to connective tissue progenitor cells (CTPs), and subsequently, enhance bone regeneration applications without the complications of autogenous cancellous bone grafts. This dissertation presents the modification of surface microtextures to provide osteoconductive stimuli to CTPs for bone regeneration applications. First, the effect of surface topography on cell proliferation and osteogenic differentiation was validated through experiments using surface post microtextures and CTPs. Post microtextures accelerated CTP growth behaviors compared to smooth polydimethylsiloxane (PDMS) and standard cell culture dishes. Second, …
Evaluation Of Upper Motor Neuron Pathology In Amyotrophic Lateral Sclerosis By Mri;Towards Identifying Noninvasive Biomarkers Of The Disease, Venkateswaran Rajagopalan
Evaluation Of Upper Motor Neuron Pathology In Amyotrophic Lateral Sclerosis By Mri;Towards Identifying Noninvasive Biomarkers Of The Disease, Venkateswaran Rajagopalan
ETD Archive
Amyotrophic lateral sclerosis (ALS) is the commonest adult motor neuron disease (MND) which causes progressive muscle paralysis and death usually within 5 years of symptom onset. As a result, only ╠â30,000 individuals in the United States are afflicted at any one time even though 5,000 or more individuals are diagnosed yearly. The diagnosis of ALS requires evidence of degeneration in upper motor neurons (UMNs) in the brain and in lower motor neurons (LMNs) that exit the brainstem and spinal cord to innervate skeletal muscles. Diagnosis can be incorrect or delayed when disease is early or atypical because non-invasive objective tests …
Cell-Taught Gene Therapy For The Preservation And Regeneration Of Cardiac Tissue Following Chronic Heart Failure, Srividya Sundararaman
Cell-Taught Gene Therapy For The Preservation And Regeneration Of Cardiac Tissue Following Chronic Heart Failure, Srividya Sundararaman
ETD Archive
Heart failure is the primary cause of mortality and morbidity in the Western world. Although cell therapy has demonstrated improvement in cardiac function, these benefits are being attributed to the activation of paracrine factors, rather than the differentiation and integration of the transplanted cells into the host tissue. Based on this knowledge the focus of this thesis work was to deliver paracrine factors, and evaluate its effect on cardiac function. Gene therapy has evolved as a promising option to deliver pro-angiogenic proteins to infarct zones, thus providing cardiac benefit. This study has identified a gene design without the use of …
The Thermodynamics Of Fluid-Phase Benzene Via Molecular Simulation, John L. Tatarko
The Thermodynamics Of Fluid-Phase Benzene Via Molecular Simulation, John L. Tatarko
ETD Archive
Accurate values for thermodynamic properties throughout the fluid phase are a requirement for the design of separation processes. To date, very few pure substances have been completely characterized because of time and monetary constraints. Low cost computing power now permits complete determination of the thermodynamic properties of pure substances via molecular simulation. Molecular simulation is computational statistical mechanics. Benzene is an important industrial chemical and pharmaceutical precursor. It is the prototypical, symmetric, hexagonal molecule and is an ideal candidate for molecular simulation. The molecular models of three researchers in the field are submitted for Monte Carlo simulation in the virtual …
Directional Solidification Of Al - 7 Wt Si Alloy, Ravi Shanker Rajamure
Directional Solidification Of Al - 7 Wt Si Alloy, Ravi Shanker Rajamure
ETD Archive
Al - 7 wt Si alloy has been directionally solidified from an aluminum single crystal seed with its [100] orientation parallel to the growth direction with a positive thermal gradient of 40 K/cm and over the range of growth speeds. Growth speed dependence of primary Dendrite Spacing and Primary Dendrite trunk Diameter has been analyzed during the step increase and step decrease in the growth speeds. Frequency distribution of Nearest Neighbor dendrites obtained from the statistical analysis shows the hexagonal distribution of dendrites. The interdendritic convection was present in the form of transverse macrosegregation and non uniform distribution of dendrites …
A Theoretical Model Of The Effect Of Bone Defects On Anterior Shoulder Instability: A Finite Element Approach, Piyush Walia
A Theoretical Model Of The Effect Of Bone Defects On Anterior Shoulder Instability: A Finite Element Approach, Piyush Walia
ETD Archive
Presence of either a Hill Sachs or a Bony Bankart lesion has been indicated as a possible cause of subluxation and anterior shoulder dislocation. Previous studies have investigated only effects of these isolated lesions on the glenohumeral instability of the shoulder. The purpose of this thesis was to investigate the effect of both Bony Bankart lesion and Hill-Sachs lesion in the glenohumeral joint on the stability of the shoulder. We hypothesize that as the size of the lesion increases, the glenohumeral joint's stability will decrease. We further hypothesize that the presence of both defects together will reduce the glenohumeral joint's …
Application Of Differential Scanning Calorimetry To Characterize Thin Film Deposition Processes, Andrew John Roger Snell
Application Of Differential Scanning Calorimetry To Characterize Thin Film Deposition Processes, Andrew John Roger Snell
ETD Archive
With the recent increase in awareness on the environmental impact of industrial coating processes, chromate-based coating processes have been elevated to the rank of the technologies targeted by the EPA for rapid replacement by environmentally friendly processes. Therefore, there is a clear need for advances in coating technologies to identify alternative industrial practices. This thesis characterizes a process developed at Cleveland State University as an alternative deposition technique to generate uniform coatings onto solid substrates. A kinetic analysis to extract scale up parameters involved in the reaction kinetics leading to high-performance coatings is demonstrated in this research. The work consists …
An Analytical Model For Rotator Cuff Repairs, A. Aurora, Jorge E. Gatica, Antonie J. Van Den Bogert, J. A. Mccarron, Kathleen A. Derwin
An Analytical Model For Rotator Cuff Repairs, A. Aurora, Jorge E. Gatica, Antonie J. Van Den Bogert, J. A. Mccarron, Kathleen A. Derwin
Mechanical Engineering Faculty Publications
Background
Currently, natural and synthetic scaffolds are being explored as augmentation devices for rotator cuff repair. When used in this manner, these devices are believed to offer some degree of load sharing; however, no studies have quantified this effect. Furthermore, the manner in which loads on an augmented rotator cuff repair are distributed among the various components of the repair is not known, nor is the relative biomechanical importance of each component. The objectives of this study are to (1) develop quasi-static analytical models of simplified rotator cuff repairs, (2) validate the models, and (3) predict the degree of load …
A Real-Time, 3-D Musculoskeletal Model For Dynamic Simulation Of Arm Movements, Edward K. Chadwick, Dimitra Blana, Antonie J. Van Den Bogert, Robert F. Kirsch
A Real-Time, 3-D Musculoskeletal Model For Dynamic Simulation Of Arm Movements, Edward K. Chadwick, Dimitra Blana, Antonie J. Van Den Bogert, Robert F. Kirsch
Mechanical Engineering Faculty Publications
Neuroprostheses can be used to restore movement of the upper limb in individuals with high-level spinal cord injury. Development and evaluation of command and control schemes for such devices typically require real-time, ldquopatient-in-the-looprdquo experimentation. A real-time, 3-D, musculoskeletal model of the upper limb has been developed for use in a simulation environment to allow such testing to be carried out noninvasively. The model provides real-time feedback of human arm dynamics that can be displayed to the user in a virtual reality environment. The model has a 3-DOF glenohumeral joint as well as elbow flexion/extension and pronation/supination and contains 22 muscles …
Subject Specific Computational Models Of The Knee To Predict Anterior Cruciate Ligament Injury, Bhushan S. Borotikar
Subject Specific Computational Models Of The Knee To Predict Anterior Cruciate Ligament Injury, Bhushan S. Borotikar
ETD Archive
Knee joint is a complex joint involving multiple interactions between cartilage, bone, muscles, ligaments, tendons and neural control. Anterior Cruciate Ligament (ACL) is one ligament in the knee joint that frequently gets injured during various sports or recreational activities. ACL injuries are common in college level and professional athletes especially in females and the injury rate is growing in epidemic proportions despite significant increase in the research focusing on neuromuscular and proprioceptive training programs. Most ACL injuries lead to surgical reconstruction followed by a lengthy rehabilitation program impacting the health and performance of the athlete. Furthermore, the athlete is still …
Application Of Dual-Energy Computed Tomography To The Evalution Of Coronary Atherosclerotic Plaque, Mitya M. Barreto
Application Of Dual-Energy Computed Tomography To The Evalution Of Coronary Atherosclerotic Plaque, Mitya M. Barreto
ETD Archive
Atherosclerotic coronary artery disease is responsible for around 50 of cardiovascular deaths in USA. Early detection and characterization of coronary artery atherosclerotic plaque could help prevent cardiac events. Computed tomography (CT) is an excellent modality for imaging calcifications and has higher spatial resolution than other common non-invasive modalities (e.g MRI), making it more suitable for coronary plaque detection. However, attenuation-based classification of non-calcified plaques as fibrous or lipid is difficult with conventional CT, which relies on a single x-ray energy. Dual-energy CT (DECT) may provide additional attenuation data for the identification and discrimination of plaque components. The purpose of this …
Development Of A Focused Broadband Ultrasonic Transducer For High Resolution Fundamental And Harmonic Intravascular Imaging, Chaitanya K. Chandrana
Development Of A Focused Broadband Ultrasonic Transducer For High Resolution Fundamental And Harmonic Intravascular Imaging, Chaitanya K. Chandrana
ETD Archive
Intravascular ultrasound (IVUS) is increasingly employed for detection and evaluation of coronary artery diseases. Tissue Harmonic Imaging provides different tissue information that could additionally be used to improve diagnostic accuracy. However, current IVUS systems, with their unfocussed transducers, may not be capable of operating in harmonic imaging mode. Thus, there is a need to develop suitable transducers and appropriate techniques to allow imaging in multi modes for complementary diagnostic information. Focused PVDF TrFE transducers were developed using MEMS (Micro-Electro-Mechanical-Systems) compatible protocols. The transducers were characterized using pulse-echo techniques and exhibited broad bandwidth (110 at -6dB) with axial resolutions of Such …
Altered Cortico-Cortical Brain Connectivity During Muscle Fatigue, Zhiguo Jiang
Altered Cortico-Cortical Brain Connectivity During Muscle Fatigue, Zhiguo Jiang
ETD Archive
Traditional brain activation studies using neuroimaging such as functional magnetic imaging (fMRI) have shown that muscle fatigue at submaximal intensity level is associated with increased brain activity in various cortical regions from low- to high-order motor centers. However, how these areas might interact remain unclear since previous activation studies related to motor control could not reveal information of between-area interaction. This issue can be addressed by evaluating brain activation data using the framework of connectivity analysis. Three types of brain connectivity, functional connectivity (FC), effective connectivity (EC) and structural connectivity (SC) have been examined to investigate the effect of voluntary …
Imaging Of Tyramine-Substituted Hydrogels For Tissue Replacement, Ediuska V. Laurens
Imaging Of Tyramine-Substituted Hydrogels For Tissue Replacement, Ediuska V. Laurens
ETD Archive
Novel tyramine-based hyaluronan (HA) and collagen hydrogels have been developed in which cross-linking is accomplished via peroxidase-mediated dityramine linkages allowing direct cross-linking in vivo. These TB hydrogels possess advantageous physical properties, which include excellent biocompatibility and the ability to mimic the biological, structural and mechanical properties of normal, healthy tissues, including cartilage, and thus provide for synthetic, implantable biomaterials suitable for a wide range of tissue types. The efficacy of these TB-hydrogels has been previously tested in a number of clinically relevant animal models, which have evaluated their applicability for the repair/replacement of various tissues, including cartilage. Nevertheless, there exists …
Semi-Automatic Segmentation Of Normal Female Pelvic Floor Structures From Magnetic Resonance Images, Xiaolong Li
Semi-Automatic Segmentation Of Normal Female Pelvic Floor Structures From Magnetic Resonance Images, Xiaolong Li
ETD Archive
Stress urinary incontinence (SUI) and pelvic organ prolapse (POP) are important health issues affecting millions of American women. Investigation of the cause of SUI and POP requires a better understand of the anatomy of female pelvic floor. In addition, pre-surgical planning and individualized treatment plans require development of patient-specific three-dimensional or virtual reality models. The biggest challenge in building those models is to segment pelvic floor structures from magnetic resonance images because of their complex shapes, which make manual segmentation labor-intensive and inaccurate. In this dissertation, a quick and reliable semi-automatic segmentation method based on a shape model is proposed. …
Two Approaches For Cell Retention In Perfusion Culture Systems, Zhaowei Wang
Two Approaches For Cell Retention In Perfusion Culture Systems, Zhaowei Wang
ETD Archive
A lack of efficient, economical, and reliable cell retention devices has limited the application of perfusion culture systems in the biopharmaceutical industry. Two types of cell retention devices were developed in this work for long-term perfusion culture systems: a modification of an inclined gravity settler and a variation of an ultrasonic filter. Both bench-top and large-scale tests showed that the gravity settler can effectively retain viable cells and preferentially remove nonviable cells in perfusion culture systems. The viable cell retention rate can be maintained well above 90 during long-term perfusion culture period while the nonviable cell retention rate is 20-30 …
Cortical Bone Tissue Engineering;Scaffold Design And Cell Selection, Demin Wen
Cortical Bone Tissue Engineering;Scaffold Design And Cell Selection, Demin Wen
ETD Archive
Cortical bone tissue engineering provides a promising approach to generate graft materials needed to treat the large sized bone defects. The underling premise of tissue engineering is to mimic the in vivo microenvironment as best as possible in vitro culture system. To select an appropriate scaffold material used in this model system, mechanical and hydraulic permeability properties of 316L porous stainless steel and polymethylmethacrylate (PMMA) were studied, as well as their biocompatibility in short and long term cell culture. Results showed that scaffolds made of both stainless steel and PMMA: (1) could be manufactured to have similar permeability as that …
The Synthesis And Characterization Of Novel Elastin-Like Polypeptides Containing An Oligomerization Domain, James T. Cole
The Synthesis And Characterization Of Novel Elastin-Like Polypeptides Containing An Oligomerization Domain, James T. Cole
ETD Archive
Elastin like polypeptides (ELPs) are an emerging class of biomaterials due to their unique group of chemical, physical and biological properties. We have constructed a library of ELPs based on the pentapeptide amino acid repeat sequence (GVGVP). ELPs exhibit lower critical solution temperature (LCST) transition behavior from a soluble phase below the transition temperature (Tt) to an insoluble two phase system above the transition temperature. This process is completely reversible so that ELPs can become soluble again upon lowering the temperature. This temperature can be tuned in many different ways at the molecular level by changing the composition of the …