Explicit Finite Element Modeling Of The Human Lumbar Spine, Milind Rao Jan 2012

Explicit Finite Element Modeling Of The Human Lumbar Spine, Milind Rao

Electronic Theses and Dissertations

Validated finite element (FE) models of the functional spinal unit (FSU) and lumbar spine are essential in design-phase device development and in assessing the mechanics associated with normal spine function and degenerative disc disease (DDD), as well as the impact of fusion and total disc replacement (TDR). Although experimental data from fully intact specimens can be used for model calibration and validation, the contributions from the individual structures (disc, facets, and ligaments) may be inappropriately distributed. Hence, creation of decompression conditions or device implantations that require structure removal may not have the proper resulting mechanics. An explicit FE formulation may …


Simvastatin Improves Spinal Fusion In Rats, Bora Bostan, Taner Güneş, Murat Aşçi, Cengiz Şen, Mehmet Halidun Keleştemur, Mehmet Erdem, Reşit Doǧan Köseoǧlu, Ünal Erkorkmaz Dec 2011

Simvastatin Improves Spinal Fusion In Rats, Bora Bostan, Taner Güneş, Murat Aşçi, Cengiz Şen, Mehmet Halidun Keleştemur, Mehmet Erdem, Reşit Doǧan Köseoǧlu, Ünal Erkorkmaz

Faculty Publications - Mechanical Engineering

Objective: Statins stimulate bone formation by inducing the expression of bone morphogenetic proteins (BMP-2). The aim of our study was to investigate the effects of orally administered simvastatin on spinal fusion in rats. Methods: Twenty rats were randomized into a spinal fusion group (SF) (n=10) or a spinal fusion and oral simvastatin administered group (SFS) (n=10). A spinal fusion was performed between L4-L6 representing two levels. Simvastatin (120 mg/kg/day) was administered orally in the SFS group. The rats were killed at the end of the 12 week study period. Results: Manual palpation revealed two moderate fusions in the SF group. …


Effect Of Extracellular Matrix (Ecm) Protein Micropatterns On The Behavior Of Human Neuroblastoma Cells, Ishwari Poudel Dec 2011

Effect Of Extracellular Matrix (Ecm) Protein Micropatterns On The Behavior Of Human Neuroblastoma Cells, Ishwari Poudel

Department of Engineering Mechanics: Dissertations, Theses, and Student Research

Recent advances in patterning techniques and emerging surface microtechnologies have allowed cell micropatterning to control spatial location of the cells on a surface as well as cell shape, attachment area, and number of contacting neighbor cells. These parameters play important roles in cell cellular behaviors. Cell micropatterning has thus become one of the most important strategies for biomedical applications, such as, tissue engineering, diagnostic immunoassays, lab-on-chip devices, bio-sensing, etc., and cell biology studies as well. For neuronal cells, there have been attempts to distribute neuronal cells on specific patterns to control cell-to-cell interaction. However, there have been very limited understanding …


Strider, George Cummings, Brian Kreidle, Ricky Lee, Clark Steen Dec 2011

Strider, George Cummings, Brian Kreidle, Ricky Lee, Clark Steen

Mechanical Engineering

No abstract provided.


Effectiveness Of Group Kickboxing As A Means To Improve Gait And Balance In Individuals With Ms, Kurt Jackson, Kimberly Edginton Bigelow, Christina Cooper, Harold L. Merriman Oct 2011

Effectiveness Of Group Kickboxing As A Means To Improve Gait And Balance In Individuals With Ms, Kurt Jackson, Kimberly Edginton Bigelow, Christina Cooper, Harold L. Merriman

Mechanical and Aerospace Engineering Faculty Publications

In recent years, there has been a particular emphasis on identifying and delivering appropriate therapeutic interventions that address the significant balance and gait impairments that affect individuals with multiple sclerosis (MS). Group interventions implemented in community settings have been especially of interest, including tai chi classes. Recently, the authors conducted a preliminary study to examine whether group kick-boxing, which requires more vigorous movements, might be a feasible intervention. Initial findings showed promise and led the authors to pursue a more rigorous follow-up study, with the objective of determining whether a 5-week group kickboxing class improved clinical measures of balance and …


Ros-Drill Automation: Visual Feedback Control And Rotational Motion Tracking, Jhon F. Diaz Aug 2011

Ros-Drill Automation: Visual Feedback Control And Rotational Motion Tracking, Jhon F. Diaz

Master's Theses

ICSI (intra-cytoplasmic sperm injection) has attracted research interest from both biological and engineering groups. The technology is constantly evolving to perform this procedure with precision and speed. One such development is the contribution of this thesis. We focus on a relatively recent procedure called Ros-Drill© (rotationally oscillating drill), of which the early versions have already been effectively utilized for the mice. In the first part, we present a procedure to automate a critical part of the operation: initiation of the rotational oscillation, Visual feedback is used to track the pipette tip. Predetermined species-specific penetration depth is successfully utilized …


Muscle Contributions To Frontal And Transverse Plane Whole-Body Angular Momentum, Richard R. Neptune, Craig P. Mcgowan, Allison Kinney Jul 2011

Muscle Contributions To Frontal And Transverse Plane Whole-Body Angular Momentum, Richard R. Neptune, Craig P. Mcgowan, Allison Kinney

Mechanical and Aerospace Engineering Faculty Publications

The purpose of this study was to build upon previous work by analyzing how gravity and individual muscles contribute to frontal and traverse plane whole-body angular momentum. Identifying which muscles are responsible for generating angular momentum has important implications for the diagnosis and treatment of movement disorders.


A Study On Facility Planning Using Discrete Event Simulation: Case Study Of A Grain Delivery Terminal, Sarah M. Asio Jul 2011

A Study On Facility Planning Using Discrete Event Simulation: Case Study Of A Grain Delivery Terminal, Sarah M. Asio

Department of Industrial and Management Systems Engineering: Dissertations, Theses, and Student Research

The application of traditional approaches to the design of efficient facilities can be tedious and time consuming when uncertainty and a number of constraints exist. Queuing models and mathematical programming techniques are not able to capture the complex interaction between resources, the environment and space constraints for dynamic stochastic processes. In the following study discrete event simulation is applied to the facility planning process for a grain delivery terminal. The discrete event simulation approach has been applied to studies such as capacity planning and facility layout for a gasoline station and evaluating the resource requirements for a manufacturing facility. To …


A Comparison Of Two Headless Compression Screws For Operative Treatment Of Scaphoid Fractures, Ruby Grewal, Joseph Assini, David Sauder, Louis Ferreira, Jim Johnson, Kenneth Faber Jun 2011

A Comparison Of Two Headless Compression Screws For Operative Treatment Of Scaphoid Fractures, Ruby Grewal, Joseph Assini, David Sauder, Louis Ferreira, Jim Johnson, Kenneth Faber

Surgery Publications

PURPOSE: The purpose of this study was to compare the interfragmentary compression force across a simulated scaphoid fracture by two commonly used compression screw systems; the Acutrak 2 Standard and the 3.0 mm Synthes headless compression screw.

METHODS: Sixteen (8 pairs; 6 female, 2 male) cadaver scaphoids were randomly assigned to receive either the Acutrak 2 or Synthes screw with the contralateral scaphoid designated to receive the opposite. Guide wires were inserted under fluoroscopic control. Following transverse osteotomy, the distal and proximal fragments were placed on either side of a custom load cell, to measure interfragmentary compression. Screws were placed …


Control System For Mass Spectrometer, Jian Xu May 2011

Control System For Mass Spectrometer, Jian Xu

Purdue Polytechnic Masters Theses

Mass spectrometry (MS) is a very popular analytical methodology that measures the mass of ions using a mass spectrometer. It is widely used for determining masses of chemicals, the elemental composition of a sample and molecule structure. The process of mass spectrometry normally consists of ionizing chemical compounds to ions and measuring their ratios of mass to charge for analysis.

MS instruments consist of three modules: Ionization, Analysis and detection. A LabVIEW system was developed to control the three modules of a mass spectrometer, giving the required signals in a right sequence. Experiments can be carried out by using the …


Lower Extremity Biomechanics During Weightlifting Exercise Vary Across Joint And Load, Kristof Kipp, Chad Harris, Michelle B. Sabick May 2011

Lower Extremity Biomechanics During Weightlifting Exercise Vary Across Joint And Load, Kristof Kipp, Chad Harris, Michelle B. Sabick

Mechanical and Biomedical Engineering Faculty Publications and Presentations

The purpose of this study was to determine the effect of load on lower extremity biomechanics during the pull-phase of the clean. Kinematic and kinetic data of the three joints of the lower extremity were collected while participants performed multiple sets of cleans at three percentages: 65, 75, and 85% of 1-Reptition maximum (RM). General linear models with repeated measures were used to assess the influence of load on angular velocities, net torques, powers, and rates of torque development at the ankle, knee, and hip joint. The results suggest that the biomechanical demands required from the lower extremities change with …


Gas Embolic Factors In Cardiovascular Health, Eric L. Cutler Apr 2011

Gas Embolic Factors In Cardiovascular Health, Eric L. Cutler

Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research

Gas emboli are a clinical issue often encountered in the space exploration, marine construction, and medical fields.  Individuals involved with these disciplines will often have asympomatic gas emboli circulating throughout their bodies on a regular basis.  A study into the impact of chronic asymptomatic gas emboli on the risk of atherosclerosis in humans is thus presented.  This research utilized a custom built cardiovascular flow simulator and accompanying data acquisition system to experimentally determine the influence of gas emboli under varied circumstances on the mean wall shear stress of a tube in-vitro.  A directly inverse relationship between gas embolus presence in …


Ultrasonic And Stereo-Optical Characterization Techniques For Applications In Mechanical Testing, Jonathan M. Hein Apr 2011

Ultrasonic And Stereo-Optical Characterization Techniques For Applications In Mechanical Testing, Jonathan M. Hein

Department of Engineering Mechanics: Dissertations, Theses, and Student Research

This thesis considers methods developed based on ultrasonic reflections from interfaces and stereo-optical surface strain measurements to study the mechanical characterization of materials and bodies. The ultrasonic method is used to characterize wave speed and attenuation for highly attenuating samples. The stereo-optical strain measurements are used to characterize the effects of genes on mechanical properties of bone, and the dynamic characterization of blast waves in the UNL Shock Wave Trauma Mechanics facility.

A method is described and developed for characterizing the wave speed and attenuation spectrums from reflected waves from the contact surface with an unknown material. The method is …


Characterising 3d Soft Tissue Features On Joint Surfaces, Colm O'Kane Jan 2011

Characterising 3d Soft Tissue Features On Joint Surfaces, Colm O'Kane

Conference Papers

A crucial aspect of orthopaedic implant design is the prediction of surgical outcomes when the shape of a bone is necessarily altered by the addition of the implant. Matching native kinematics as closely as possible is generally considered a core aim of joint replacement surgery. The overall hypothesis behind this research is that soft tissue geometry, including cartilage thickness distribution and ligament attachment sites, influences kinematics in the knee joint. In order to enable investigation of possible links between geometry and kinematics, the ability to characterise the shape variation of the soft tissue relative to the underlying bony geometry must …


Intelligibility Of Electrolarynx Speech Using A Novel Hands-Free Actuator, Brian Madden, Mark Nolan, Ted Burke, James Condron, Eugene Coyle Jan 2011

Intelligibility Of Electrolarynx Speech Using A Novel Hands-Free Actuator, Brian Madden, Mark Nolan, Ted Burke, James Condron, Eugene Coyle

Conference Papers

During voiced speech, the larynx provides quasi-periodic acoustic excitation of the vocal tract. In most electrolarynxes, mechanical vibrations are produced by a linear electromechanical actuator, the armature of which percusses against a metal or plastic plate at a frequency within the range of glottal excitation. In this paper, the intelligibility of speech produced using a novel hands-free actuator is compared to speech produced using a conventional electrolarynx. Two able-bodied speakers (one male, one female) performed a closed response test containing 28 monosyllabic words, once using a conventional electrolarynx and a second time using the novel design. The resulting audio recordings …


A Full-Depth Amalgamated Parallel 3d Geometric Multigrid Solver For Gpu Clusters, Dana A. Jacobsen, Inanc Senocak Jan 2011

A Full-Depth Amalgamated Parallel 3d Geometric Multigrid Solver For Gpu Clusters, Dana A. Jacobsen, Inanc Senocak

Mechanical and Biomedical Engineering Faculty Publications and Presentations

Numerical computations of incompressible flow equations with pressure-based algorithms necessitate the solution of an elliptic Poisson equation, for which multigrid methods are known to be very efficient. In our previous work we presented a dual-level (MPI-CUDA) parallel implementation of the Navier-Stokes equations to simulate buoyancy-driven incompressible fluid flows on GPU clusters with simple iterative methods while focusing on the scalability of the overall solver. In the present study we describe the implementation and performance of a multigrid method to solve the pressure Poisson equation within our MPI-CUDA parallel incompressible flow solver. Various design decisions and algorithmic choices for multigrid methods …


Scalability Of Incompressible Flow Computations On Multi-Gpu Clusters Using Dual-Level And Tri-Level Parallelism, Dana A. Jacobsen, Inanc Senocak Jan 2011

Scalability Of Incompressible Flow Computations On Multi-Gpu Clusters Using Dual-Level And Tri-Level Parallelism, Dana A. Jacobsen, Inanc Senocak

Mechanical and Biomedical Engineering Faculty Publications and Presentations

High performance computing using graphics processing units (GPUs) is gaining popularity in the scientific computing field, with many large compute clusters being augmented with multiple GPUs in each node. We investigate hybrid tri-level (MPI-OpenMP-CUDA) parallel implementations to explore the efficiency and scalability of incompressible flow computations on GPU clusters up to 128 GPUS. This work details some of the unique issues faced when merging fine-grain parallelism on the GPU using CUDA with coarse-grain parallelism using OpenMP for intra-node and MPI for inter-node communication. Comparisons between the tri-level MPI-OpenMP-CUDA and dual-level MPI-CUDA implementations are shown using computationally large computational fluid dynamics …


The Hemocompatibility Of A Nitric Oxide Generating Polymer That Catalyzes S-Nitrosothiol Decomposition In An Extracorporeal Circulation Model, Terry C. Major, David O. Brant, Charles P. Burney, Kagya Amoako, Gail M. Annich, Mark E. Meyerhoff, Hitesh Handa, Robert E. Bartlett Jan 2011

The Hemocompatibility Of A Nitric Oxide Generating Polymer That Catalyzes S-Nitrosothiol Decomposition In An Extracorporeal Circulation Model, Terry C. Major, David O. Brant, Charles P. Burney, Kagya Amoako, Gail M. Annich, Mark E. Meyerhoff, Hitesh Handa, Robert E. Bartlett

Mechanical and Industrial Engineering Faculty Publications

Nitric oxide (NO) generating (NOGen) materials have been shown previously to create localized increases in NO concentration by the catalytic decomposition of blood S-nitrosothiols (RSNO) via copper (Cu)-containing polymer coatings and may improve extracorporeal circulation (ECC) hemocompatibility. In this work, a NOGen polymeric coating composed of a Cuo-nanoparticle (80 nm)-containing hydrophilic polyurethane (SP-60D-60) combined with the intravenous infusion of an RSNO, S- nitroso-N-acetylpenicillamine (SNAP), is evaluated in a 4 h rabbit thrombogenicity model and the anti-thrombotic mechanism is investigated. Polymer films containing 10 wt.% Cuo-nanoparticles coated on the inner walls of ECC circuits are employed concomitantly with systemic SNAP administration …


Nitric Oxide-Generating Silicone As A Blood-Contacting Biomaterial, Kagya Amoako Jan 2011

Nitric Oxide-Generating Silicone As A Blood-Contacting Biomaterial, Kagya Amoako

Mechanical and Industrial Engineering Faculty Publications

Coagulation upon blood-contacting biomaterials remains a problem for short and long-term clinical applications. This study examined the ability of copper(II)-doped silicone surfaces to generate nitric oxide (NO) and locally inhibit coagulation. Silicone was doped with 3-micron copper (Cu(0)) particles yielding 3 to 10 weight percent (wt%) Cu in 70-μm thick Cu/Silicone polymeric matrix composites (Cu/Si PMCs). At 3, 5, 8 and 10 wt% Cu doping, the surface expression of Cu was 12.1 ± 2.8%, 19.7 ± 5.4%, 29.0 ± 3.8%, and 33.8 ± 6.5% respectively. After oxidizing Cu(0) to Cu(II) by spontaneous corrosion, NO flux, JNO (mol*cm−2*min−1), as measured by …


Finite Element Reconstruction Of Real World Aortic Injury In Near-Side Lateral Automotive Crashes With Conceptual Countermeasures, Aditya Neelakanta Belwadi Jan 2011

Finite Element Reconstruction Of Real World Aortic Injury In Near-Side Lateral Automotive Crashes With Conceptual Countermeasures, Aditya Neelakanta Belwadi

Wayne State University Dissertations

Traumatic rupture of the aorta (TRA) remains the second most common cause of death associated with motor vehicle crashes after brain injury. On an average, nearly 8,000 people die annually in the United States due to blunt injury to the aorta. It is observed that more than 80% of occupants who suffer an aortic injury die at the scene due to exsanguination into the chest. With the advent of more accurate and established human body finite element (FE) models, FE crash reconstruction methods may become a valuable tool when assessing crash scenarios and occupant injury mechanisms.

The current study is …


Using Thermally Coupled Reactive Distillation Columns In Biodiesel Production, Nghi Nguyen, Yaşar Demirel Jan 2011

Using Thermally Coupled Reactive Distillation Columns In Biodiesel Production, Nghi Nguyen, Yaşar Demirel

Yaşar Demirel Publications

Production of ethyl dodecanoate (biodiesel) using lauric acid and methanol with a solid acid catalyst of sulfated zirconia is studied by using two distillation sequences. In the first sequence, the methanol recovery column follows the reactive distillation column. In the second sequence, the reactive distillation and methanol recovery columns are thermally coupled. Thermally coupled distillation sequences may consume less energy by allowing interconnecting vapor and liquid streams between the two columns to elminate reboiler or condenser or both. Here we study the thermally coupled side-stripper reactive distillation and eliminate the condenser of the reactive distillation column. Both the sequences are …


Role Of Hydrodynamic Behavior Of Dna Molecules In Dielectrophoretic Polarization Under The Action Of An Electric Field, Hui Zhao Jan 2011

Role Of Hydrodynamic Behavior Of Dna Molecules In Dielectrophoretic Polarization Under The Action Of An Electric Field, Hui Zhao

Mechanical Engineering Faculty Research

A continuum model is developed to predict the dielectrophoretic polarizability of coiled DNA molecules under the action of an alternating current electric field. The model approximates the coiled DNA molecule as a charged porous spherical particle. The model explains the discrepancies among scaling laws of polarizability of different-sized DNA molecules with contour length and such discrepancies are attributed to different hydrodynamic behavior. With zero or one fitting parameter, theoretical predictions are in good agreement with various experimental data, even though in experiments there are some uncertainties in regard to certain parameters.


Locating And Extracting Acoustic And Neural Signals, Na Zhu Jan 2011

Locating And Extracting Acoustic And Neural Signals, Na Zhu

Wayne State University Dissertations

This dissertation presents innovate methodologies for locating, extracting, and separating multiple incoherent sound sources in three-dimensional (3D) space; and applications of the time reversal (TR) algorithm to pinpoint the hyper active neural activities inside the brain auditory structure that are correlated to the tinnitus pathology. Specifically, an acoustic modeling based method is developed for locating arbitrary and incoherent sound sources in 3D space in real time by using a minimal number of microphones, and the Point Source Separation (PSS) method is developed for extracting target signals from directly measured mixed signals. Combining these two approaches leads to a novel technology …


Estimation Of The Centre Of Mass From Motion Capture And Force Plate Recordings: A Study On The Elderly, Sebastien Cotton, Michele Vanoncini, Philippe Fraisse, Nacim Ramdani, Emel Demircan, Andrew P. Murray, Thierry Keller Jan 2011

Estimation Of The Centre Of Mass From Motion Capture And Force Plate Recordings: A Study On The Elderly, Sebastien Cotton, Michele Vanoncini, Philippe Fraisse, Nacim Ramdani, Emel Demircan, Andrew P. Murray, Thierry Keller

Mechanical and Aerospace Engineering Faculty Publications

The estimation of the centre of mass position in humans is usually based on biomechanical models developed from anthropometric tables. This method can potentially introduce errors in studies involving elderly people, since the ageing process is typically associated with a modification of the distribution of the body mass. In this paper, an alternative technique is proposed, and evaluated with an experimental study on 9 elderly volunteers. The technique is based on a virtual chain, identified from experimental data and locating the subject's centre of mass. Its configuration defines the location of the centre of mass, and is a function of …


Creep Behaviour Of Hand Laminated Glass Reinforced Polymer Composites., Brian Quinn Jan 2011

Creep Behaviour Of Hand Laminated Glass Reinforced Polymer Composites., Brian Quinn

Theses

The creep behaviour of hand laminated, glass fiber reinforced polyester composites were studied at coupon level, due to the use of similar materials in long term load bearing civil and structural engineering applications. Creep predictions were made by fitting the parameters of several viscoelastic models to experimental creep data as well as two accelerated test methods, time temperature superposition (TTS) and frequency time transformations (FTT). TTS experiments were carried out in a dynamic mechanical analyzer (DMA) in three point bending mode for three types of material systems. Creep compliance master curves representing the linear viscoelastic creep response at reference temperatures …


A Microfluidic Device For Impedance Spectroscopy, Ahmet Can Sabuncu Jan 2011

A Microfluidic Device For Impedance Spectroscopy, Ahmet Can Sabuncu

Mechanical & Aerospace Engineering Theses & Dissertations

Recently, microfluidics has become a versatile tool to investigate cellular biology and to build novel biomedical devices. Dielectric spectroscopy, on the other hand, allows non-invasive probing of biological cells. Information on the cell membrane, cytoplasm, and nucleus can be obtained by dielectric spectroscopy provided that appropriate tools are used in specific frequency ranges. This dissertation includes fabrication, characterization, and testing of a simple microfluidic device to measure cell dielectric properties. The dielectric measurements are performed on human T-cell leukemia (Jurkat), mouse melanoma (B16), mouse hepatoma (Hepa), and human costal chondrocyte cells. Dielectric measurements consist of measuring the complex impedance of …


Experimental And Computational Analysis Of An Energy Storage Composite Ankle Foot Orthosis, Michelle C. Hawkins Dec 2010

Experimental And Computational Analysis Of An Energy Storage Composite Ankle Foot Orthosis, Michelle C. Hawkins

UNLV Theses, Dissertations, Professional Papers, and Capstones

Ankle Foot Orthotics (AFOs) are used by individuals presenting with Charcot-Marie-Tooth (CMT) to assist with improving gait. Mitch Warner, CPO, has developed a composite AFO made from woven carbon-Kevlar and carbon fiber lamina. The overall goals of the research are to characterize the HELIOS brace and to determine its effect on the gait of CMT subjects. Human motion analysis, experimental mechanical testing, and Finite Element Analysis (FEA) are used to gain a better understanding of how the materials and geometric design of the HELIOS AFO contribute to gait.


Human motion experiments are performed to determine the relationship between ground reaction …


Personal Navigation Via High-Resolution Gait-Corrected Inertial Measurement Units, Özkan Bebek, Michael A. Suster, Srihari Rajgopal, Michael J. Fu, Xuemei Huang, M. Cenk Çavu¸So˘Glu,, Darrin J. Young, Mehran Mehregany, Antonie J. Van Den Bogert, Carlos H. Mastrangelo Nov 2010

Personal Navigation Via High-Resolution Gait-Corrected Inertial Measurement Units, Özkan Bebek, Michael A. Suster, Srihari Rajgopal, Michael J. Fu, Xuemei Huang, M. Cenk Çavu¸So˘Glu,, Darrin J. Young, Mehran Mehregany, Antonie J. Van Den Bogert, Carlos H. Mastrangelo

Mechanical Engineering Faculty Publications

In this paper, a personal micronavigation system that uses high-resolution gait-corrected inertial measurement units is presented. The goal of this paper is to develop a navigation system that uses secondary inertial variables, such as velocity, to enable long-term precise navigation in the absence of Global Positioning System (GPS) and beacon signals. In this scheme, measured zerovelocity duration from the ground reaction sensors is used to reset the accumulated integration errors from accelerometers and gyroscopes in position calculation. With the described system, an average position error of 4 m is achieved at the end of half-hour walks.


Individual Muscle Contributions To The Axial Knee Joint Contact Force During Normal Walking, Kotaro Sasaki, Richard R. Neptune Oct 2010

Individual Muscle Contributions To The Axial Knee Joint Contact Force During Normal Walking, Kotaro Sasaki, Richard R. Neptune

Mechanical and Biomedical Engineering Faculty Publications and Presentations

Muscles are significant contributors to the high joint forces developed in the knee during human walking. Not only do muscles contribute to the knee joint forces by acting to compress the joint, but they also develop joint forces indirectly through their contributions to the ground reaction forces via dynamic coupling. Thus, muscles can have significant contributions to forces at joints they do not span. However, few studies have investigated how the major lower-limb muscles contribute to the knee joint contact forces during walking. The goal of this study was to use a muscle-actuated forward dynamics simulation of walking to identify …


Modeling Of Micro-Diaphragm For Optical Pressure Sensor For Human Artery Pulse Wave Detection., Khairunnisa Hasikin Sep 2010

Modeling Of Micro-Diaphragm For Optical Pressure Sensor For Human Artery Pulse Wave Detection., Khairunnisa Hasikin

Student Works (2010-2019)

This thesis presents the development of a micro-diaphragm for an optical pulse pressure sensor using Micro-electro-mechanical Systems (MEMS) technology. Modelling of the micro-diaphragm was conducted and the comparison of its performance was simulated for silicon nitride and polyirnide materials. In addition. diaphragm's radius and thickness were varied to further analyze the performance of the micro-diaphragm. There are three design parameters that affecting the micro-diaphragm performance namely diaphragms radius. thickness and material. Thus, an optimization analysis using Taguchi method was done to attain significant design parameters that give the best micro-diaphragm performance. Findings indicated that the best performance of the micro-diaphragm …