Open Access. Powered by Scholars. Published by Universities.®
Biomedical Engineering and Bioengineering Commons™
Open Access. Powered by Scholars. Published by Universities.®
- Institution
-
- Al Esraa University (115)
- Boise State University (98)
- California Polytechnic State University, San Luis Obispo (67)
- Tashkent State Technical University (56)
- Yıldız Technical University (56)
-
- University of Nebraska - Lincoln (37)
- University of Denver (34)
- University of Nevada, Las Vegas (34)
- Old Dominion University (31)
- Purdue University (25)
- Michigan Technological University (22)
- University of Kentucky (21)
- University of Dayton (19)
- Technological University Dublin (18)
- Rowan University (17)
- University of Mississippi (16)
- University of Texas Rio Grande Valley (16)
- Virginia Commonwealth University (16)
- South Dakota State University (15)
- University of Central Florida (15)
- University of Arkansas, Fayetteville (13)
- Clemson University (12)
- Cleveland State University (12)
- University of South Florida (12)
- Washington University in St. Louis (12)
- University of New Haven (11)
- City University of New York (CUNY) (10)
- Embry-Riddle Aeronautical University (9)
- Georgia Southern University (9)
- The University of Akron (9)
- Keyword
-
- Biomechanics (36)
- Daniel Felix Ritchie School of Engineering and Computer Science (32)
- Mechanical and Materials Engineering (29)
- BRC (26)
- Mechanical Engineering (22)
-
- Finite element analysis (16)
- Engineering (12)
- Microfluidics (12)
- Department of Biomedical Engineering (11)
- Gait (11)
- Simulation (11)
- 3D Printing (10)
- Bioengineering (10)
- Machine learning (10)
- Optimization (10)
- Robotics (10)
- Deep learning (9)
- Materials Science (9)
- Biomedical Engineering (8)
- Biomedical engineering (8)
- Computational fluid dynamics (8)
- Department of Mechanical Engineering-Engineering Mechanics (8)
- Design (8)
- Mechanobiology (8)
- Rehabilitation (8)
- Biomaterials (7)
- CFD (7)
- Compressive strength (7)
- Computer Science (7)
- Electrospinning (7)
- Publication Year
- Publication
-
- Al-Esraa University College Journal for Engineering Sciences (115)
- Mechanical and Biomedical Engineering Faculty Publications and Presentations (93)
- Journal of Sustainable Construction Materials and Technologies (56)
- Technical science and innovation (55)
- Electronic Theses and Dissertations (45)
-
- Theses and Dissertations (36)
- UNLV Theses, Dissertations, Professional Papers, and Capstones (32)
- Mechanical Engineering (30)
- Master's Theses (25)
- Mechanical Engineering Faculty Publications (21)
- Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research (20)
- Mechanical & Aerospace Engineering Theses & Dissertations (20)
- Mechanical and Aerospace Engineering Faculty Publications (19)
- Conference Papers (15)
- Biomedical Engineering (13)
- Faculty and Student Publications (13)
- McKelvey School of Engineering Graduate Student Theses & Dissertations (12)
- Theses and Dissertations--Mechanical and Aerospace Engineering (12)
- USF Tampa Graduate Theses and Dissertations (12)
- Honors Undergraduate Theses (11)
- The Summer Undergraduate Research Fellowship (SURF) Symposium (10)
- Dissertations, Master's Theses and Master's Reports (9)
- Dissertations and Theses (8)
- Michigan Tech Publications (8)
- Wayne State University Dissertations (8)
- College of Graduate Studies: Theses & Dissertations (7)
- Mechanical and Industrial Engineering Faculty Publications (7)
- All Theses (6)
- Department of Mechanical and Materials Engineering: Faculty Publications (6)
- Honors Theses (6)
- Publication Type
- File Type
Articles 751 - 780 of 1006
Full-Text Articles in Biomedical Engineering and Bioengineering
Detection Of Structural Bolt Detorquing Using Direct Stethoscope Measurement, Joe Guarino, Robert Hamilton
Detection Of Structural Bolt Detorquing Using Direct Stethoscope Measurement, Joe Guarino, Robert Hamilton
Mechanical and Biomedical Engineering Faculty Publications and Presentations
A method for detecting loosened bolts in a structural joint based upon open-loop acoustic measurement is presented. The acoustic measurement is taken directly on the bolt head. The response of the bolt to a proximal hammer impact is evaluated and characterized using wavelet decomposition of the signal measured from the bolt head. Data were also taken from an accelerometer mounted longitudinally and transversely on the bolt head. Results from the stethoscope and the accelerometer are presented from a set of structural bolts in several conditions of preload and looseness. A stethoscope applied to the loose bolt and a proximal bolt …
Force Compensation And Recreation Accuracy In Humans, Benjamin Rigsby
Force Compensation And Recreation Accuracy In Humans, Benjamin Rigsby
USF Tampa Graduate Theses and Dissertations
As industry becomes increasingly reliant on robotic assistance and human-computer interfaces, the demand to understand the human sensorimotor system’s characteristics intensifies. Although this field of research has been going on for over a century, new technologies push the limits of the human motor system and our knowledge of it. With new technologies come new abilities, and, in the area of medical care and rehabilitation, the need to expand our knowledge of the sensorimotor system comes from both the patient and physician.
Two studies relating to human force interaction are presented in this thesis. The first study
focuses on humans’ ability …
Effects Of Passive And Active Training Paradigms On Bone And Muscle Recovery After Spinal Cord Injury, Brittany Lynn King
Effects Of Passive And Active Training Paradigms On Bone And Muscle Recovery After Spinal Cord Injury, Brittany Lynn King
Theses and Dissertations
The effects spinal cord injury (SCI) has have been studied in both human and animal models. Specifically in incomplete SCI, the bone degradation and muscle atrophy seen in the lower limbs has been documented, along with the effects of different training paradigms on bone and muscle loss. This study implemented a clinically relevant animal model of a moderate spinal contusion injury at the T9--T10 level, along with active body weight supported treadmill training (BWSTT) and passive bike training, to compare the effects such training methods have on the bone microstructure properties and muscle masses in the lower limbs of rats. …
Blood-Brain Barrier-On-A-Chip Systems Based On 3d Printing, Cade I. Harding
Blood-Brain Barrier-On-A-Chip Systems Based On 3d Printing, Cade I. Harding
Mechanical Engineering Undergraduate Honors Theses
This research focused on the design and testing of a blood-brain barrier (BBB)-on-a-chip microfluidic device produced using 3D printing. First, COMSOL simulations were used to define dimensions of the microchannel that would most accurately replicate the flow environment imposed on the blood-brain barrier, the wall shear stress being the most important characteristic. In using COMSOL, water was used as the simulated fluid and also the testing fluid in the fabricated devices. Therefore, the microsystem is designed to produce the BBB environment using water instead of blood. The numerical simulation parameters were based on theoretical calculations performed to scale up the …
Development Of Peritoneal Microbubble Oxygenation As An Extrapulmonary Treatment For Hypoxia, Nathan Legband
Development Of Peritoneal Microbubble Oxygenation As An Extrapulmonary Treatment For Hypoxia, Nathan Legband
Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research
Patients affected by a respiratory disease or injury experience a substantially impaired respiratory system and as a consequence are unable to obtain a sufficient amount of oxygen. Hypoxia can quickly result in developing permanent tissue damage or death. Currently, the medical methods of treating hypoxia are mechanical ventilation or extracorporeal membrane oxygenation. However, these treatments are ineffective in certain cases and possess significant additional risks including barotrauma, infection, hemorrhage, and thrombosis.
The extrapulmonary method of peritoneal oxygenation has been investigated by other research groups as a potential alternative to providing supplemental oxygen in hypoxic animals. In peritoneal oxygenation, the peritoneum, …
Design And Validation Of An In Vivo Long-Term Attachment Capsule Robot, Wanchuan Xie
Design And Validation Of An In Vivo Long-Term Attachment Capsule Robot, Wanchuan Xie
Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research
The invention of capsule endoscopy (CE) made the non-invasive monitoring of the entire small bowel possible and became the primary means for diagnosing small bowel pathology. In the last decade, capsule robots have been transformed from diagnostic devices into a widely studied biomedical platform with the potential for active locomotion, drug delivery and therapeutic capabilities. To perform accurate on-site drug release and therapy, it is necessary for a capsule robot to be able to attach to the intestinal tissue and maintain its position long-term. Design challenges derive from the task of long-term mucosal adhesion which requires firm, quick-response attachment without …
Development And Evaluation Of A Biocompatible Electroactive Sensor For Continuous Blood Pressure Measurement., Scott D. Cambron
Development And Evaluation Of A Biocompatible Electroactive Sensor For Continuous Blood Pressure Measurement., Scott D. Cambron
Electronic Theses and Dissertations
Piezo-active composites have been implemented for sensing and transduction for decades. The 0-3 ceramic/polymer composite is one of the most common composite types used for sensing applications, owing to their tailorable properties of the two-phase composition, consisting of a three-dimensionally connected polymer/rubber matrix (inactive phase) with a dispersion of isolated piezo-ceramic particles (active phase). This thesis describes a method to develop novel biocompatible perivascular band comprised of a two-phase piezo-active composite to be fabricated using simple manufacturing processes. Biomaterials such as tissue scaffolds comprised of silk fibroin (SF) and chitosan (CS), and biocompatible soft rubbers will be implemented as the …
Method And Shear-Driven Micro-Fluidic Pump, Nihad E. Daidzic
Method And Shear-Driven Micro-Fluidic Pump, Nihad E. Daidzic
Aviation Department Publications
United States Patent Application, Publication Number US 2017/0096990 A1, Publication Date April 6, 2017.
An example includes an apparatus to pump a fluid. The apparatus includes a housing extending along a length defining an elongate interior, an actuator in the housing, conforming to the elongate interior, the actuator including a plurality of lumens, each having a length extending substantially parallel to the elongate interior, each from around 10 to 200 micrometers across and an actuator configured to oscillate the actuator in the actuator housing along the length of the elongate interior with a rate differential between movement in a first …
Redesign Of Computer Keyboards For Hospital And Consumer Use, Kent Williams, Brian Jensen, Anton Bowden
Redesign Of Computer Keyboards For Hospital And Consumer Use, Kent Williams, Brian Jensen, Anton Bowden
Biomedical Engineering Western Regional Conference
Application of carbon nanotube coatings to computer keyboards in order to reduce the spread of bacteria in hospitals and homes.
Keywords: carbon nanotube, bacteria, antimicrobial, keyboard, design, MRSA, biofilm
Soft-Tissue Artifact Compensation For Electromagnetic Motion Capture, George T. Dickinson, Steven K. Charles
Soft-Tissue Artifact Compensation For Electromagnetic Motion Capture, George T. Dickinson, Steven K. Charles
Biomedical Engineering Western Regional Conference
This purpose of this study is to develop a soft-tissue artifact compensation algorithm for the upper arm using electromagnetic motion capture systems that can be implemented in a wide range of applications. This study focuses on compensation of humeral axial rotation and forearm axial rotation.
A Nanocomposite Sensor Neck Sleeve For Tracking In Vivo Spine Kinematics In The Alpaca, Colton Porter Graham, Anton Bowden
A Nanocomposite Sensor Neck Sleeve For Tracking In Vivo Spine Kinematics In The Alpaca, Colton Porter Graham, Anton Bowden
Biomedical Engineering Western Regional Conference
Chronic low back pain in the US is often attributed to intervertebral disc degeneration. Camelids, particularly alpacas, pose a potential model for spinal treatment due to similarity of the spinal structure and vertical loading. Alpacas also exhibit a high rate of natural disc degeneration. To gain more understanding about how disc degeneration is caused in alpacas it is necessary to understand the loading and motion of the alpaca cervical spine. The goal of the present work was to incorporate nanocomposite sensors into a custom-designed neck sleeve to track the daily in-vivo neck motion of an alpaca in its natural environment.
Portable, Powerless Automation Of Valve Actuation For Microfluidic Large-Scale Integration Technology, Andrew Schmidt Mr., Matt Fitzgerald Mr., Emre Araci Mr., Connor Mcloughlin Mr.
Portable, Powerless Automation Of Valve Actuation For Microfluidic Large-Scale Integration Technology, Andrew Schmidt Mr., Matt Fitzgerald Mr., Emre Araci Mr., Connor Mcloughlin Mr.
Biomedical Engineering Western Regional Conference
Portable, powerless automation of valve actuation for microfluidic large-scale integration technology
Biophysical Tools To Study Cellular Mechanotransduction, Ismeel Muhamed, Farhan Chowdhury, Venkat Maruthamuthu
Biophysical Tools To Study Cellular Mechanotransduction, Ismeel Muhamed, Farhan Chowdhury, Venkat Maruthamuthu
Mechanical & Aerospace Engineering Faculty Publications
The cell membrane is the interface that volumetrically isolates cellular components from the cell's environment. Proteins embedded within and on the membrane have varied biological functions: reception of external biochemical signals, as membrane channels, amplification and regulation of chemical signals through secondary messenger molecules, controlled exocytosis, endocytosis, phagocytosis, organized recruitment and sequestration of cytosolic complex proteins, cell division processes, organization of the cytoskeleton and more. The membrane's bioelectrical role is enabled by the physiologically controlled release and accumulation of electrochemical potential modulating molecules across the membrane through specialized ion channels (e.g., Na⁺, Ca2+, K⁺ channels). …
Development And Verification Of A Mechanical Loading Device For Microfluidics, Stefan Habean, Erin Tesny
Development And Verification Of A Mechanical Loading Device For Microfluidics, Stefan Habean, Erin Tesny
Undergraduate Research Posters 2017
Establishing the role that mechanics play in nerve cell (e.g. neurons) function requires experimental testing. Microfluidic based experiments are commonly used to study neuron growth and function, and studies have found mechanics to play an important role in neuron health. External loads can be applied to a microfluidic device using a motor, which presumably influences the mechanical environment of the cells. While a motor can easily apply known displacements, a “load cell” is necessary to measure corresponding forces. In an existing prototype microfluidic loading device, a load cell was integrated and verified. The manufacturer's calibration of the load cell was …
Design And Control Of A Powered Rowing Machine With Programmable Impedance, Jose Humberto De La Casas Zolezzi
Design And Control Of A Powered Rowing Machine With Programmable Impedance, Jose Humberto De La Casas Zolezzi
ETD Archive
Due to the rise of obesity, diabetes and cardiovascular disease, research in human performance and physical activity has received increased attention. Rowing machines are used for performance improvements through concentric exercises, however a combination of concentric and eccentric actions is known to improve the effectiveness of training. In this work, a conventional rowing machine was modified to include an electric motor and a robust impedance control system, enabling programmable impedance with concentric and eccentric capabilities. Eccentric exercises are known to contribute significantly to the efficacy of training and to diminish the detrimental effects of humans operating in microgravity for long …
Biomechanics Of Concussion: The Importance Of Neck Tension, Ron Jadischke
Biomechanics Of Concussion: The Importance Of Neck Tension, Ron Jadischke
Wayne State University Dissertations
Linear and angular velocity and acceleration of the head are typically correlated to concussion. Despite improvements in helmet performance to reduce accelerations, a corresponding reduction in the incidence of concussion has not occurred (National Football League [NFL] 1996 – present).
There is compelling research that forces on and deformation to the brain stem are related to concussion. The brain stem is the center of control for respiration, blood pressure and heart rate and is the root of most cranial nerves. Injury to the brain stem is consistent with most symptoms of concussion reported in the National Football League and the …
Anisotropy Evolution Due To Surface Treatment On 3d-Printed Fused Deposition Modeling (Fdm) Of Acrylonitrile Butadiene Styrene (Abs), Blake E. Lozinski
Anisotropy Evolution Due To Surface Treatment On 3d-Printed Fused Deposition Modeling (Fdm) Of Acrylonitrile Butadiene Styrene (Abs), Blake E. Lozinski
Honors Undergraduate Theses
Purpose: This paper will present insight to the methodology and results of the experimental characterization of Acrylonitrile Butadiene Styrene (ABS) using Fused Deposition Modeling (FDM). The work in this research explored the effects of print orientation, surface treatment, and ultraviolet (UV) light degradation with the utilization of Digital Image Correlation (DIC) on ABS tensile specimens.
Design/methodology: ABS specimens were printed at three build orientations (flat (0 degrees), 45 degrees, and up-right (90 degrees)). Each of these specimens were treated with three different surface treatments including a control (acrylic paint, Cyanoacrylate, and Diglycidyl Bisphenol A) followed by exposure to UV light …
Development Of A Finite Element Pelvis And Lower Extremity Model With Growth Plates For Pediatric Pedestrian Protection, Ming Shen
Wayne State University Dissertations
Finite element (FE) model is a useful tool frequently used for investigating the injury mechanisms and designing protection countermeasures. At present, no 10 years old (YO) pedestrian FE model has been developed from appropriate anthropometries and validated against limitedly available impact response data. A 10 YO child FE pelvis and lower extremities (PLEX) model was established to fill the gap of lacking such models in this age group. The baseline model was validated against available pediatric postmortem human subjects (PMHS) test data and additional scaled adult data, then the PLEX model was integrated to build a whole-body FE model representing …
Development & Validation Of An Improved Biomechanical Model For Motion Analysis, Darren Dawson
Development & Validation Of An Improved Biomechanical Model For Motion Analysis, Darren Dawson
Theses
Three dimensional motion analysis systems are utilised across a number of different disciplines, including clinical gait analysis, sports performance studies and analysis of tasks of daily living. These systems utilise biomechanical models which define body segment coordinate systems and calculate kinematic and kinetic relationships about the joints between adjacent coordinate systems. In this study, a biomechanical model for general use in motion analysis was developed and validated. It was designed to improve upon the accuracy and capability of currently available models. The newly developed model utilises state of the art techniques to accurately define body segment coordinate systems. Accurate predictive …
Age-Related Differences In The Lumbopelvic Kinematics During The Trunk Motions In The Anatomical Planes, Milad Vazirian
Age-Related Differences In The Lumbopelvic Kinematics During The Trunk Motions In The Anatomical Planes, Milad Vazirian
Theses and Dissertations--Biomedical Engineering
Management and control of the low back pain as an important health problem in the industrial societies necessitates to investigate how the risk of this disease is affected by aging. Since the abnormalities of the lumbopelvic kinematics are related to the existence or risk of low back injuries, the objective of this dissertation was set to find the age-related differences in lumbopelvic kinematics when performing basic trunk motions reaching to range of motion in different anatomical planes.
A cross-sectional study was designed where sixty asymptomatic individuals between 20–70 years old with no confounding health condition, no current or previous highly …
Shape Memory Behavior Of Dense And Porous Niti Alloys Fabricated By Selective Laser Melting, Soheil Saedi
Shape Memory Behavior Of Dense And Porous Niti Alloys Fabricated By Selective Laser Melting, Soheil Saedi
Theses and Dissertations--Mechanical and Aerospace Engineering
Selective Laser Melting (SLM) of Additive Manufacturing is an attractive fabrication method that employs CAD data to selectively melt the metal powder layer by layer via a laser beam and produce a 3D part. This method not only opens a new window in overcoming traditional NiTi fabrication problems but also for producing porous or complex shaped structures. The combination of SLM fabrication advantages with the unique properties of NiTi alloys, such as shape memory effect, superelasticity, high ductility, work output, corrosion, biocompatibility, etc. makes SLM NiTi alloys extremely promising for numerous applications.
The SLM process parameters such as laser power, …
Computational Studies On Biomechanics Of Concussion And On Efficacy Of Football Helmets, David Labyak
Computational Studies On Biomechanics Of Concussion And On Efficacy Of Football Helmets, David Labyak
Dissertations, Master's Theses and Master's Reports
Football helmets have been used for many years to prevent head injuries to players. Over the years, the helmet design has evolved from a crude leather head covering to the more recent form fitting helmets that are seen today. The one design feature that has been common in the majority of all helmets is a hard polycarbonate shell with a foam cushion padding. The main goal of the padding layer was to reduce the amount of linear acceleration during an impact event. The one feature that has been overlooked is how stiff the padding is in rotation.
The purpose of …
Skintronics: Wireless, Skin-Wearable Electronics For Monitoring Of Electrocardiogram, Matthew B. Piper, Woon-Hong Yeo, Yongkuk Lee
Skintronics: Wireless, Skin-Wearable Electronics For Monitoring Of Electrocardiogram, Matthew B. Piper, Woon-Hong Yeo, Yongkuk Lee
UROP Posters
The ECGs I micro-fabricate are designed to be flexible, stretchable and wireless circuits that can be applied to the skin directly. The device is encased in a conformal, silicon-like substrate, that allows the ECG to be attached with the electrodes. Each electrode has been previously measured and verified that it will be correctly placed for an accurate reading. Prototyping this ECG/electrode device allows the user to mount the prototype directly to the patient without having to attach and wire ten other electrodes. This prototype solves the issue that comes about when a doctor, nurse or emergency medical technician must attach …
Statistical Shape Modeling To Quantify Variation In The Proximal Humeral Anatomy, Paul B. Sade Sr.
Statistical Shape Modeling To Quantify Variation In The Proximal Humeral Anatomy, Paul B. Sade Sr.
Electronic Theses and Dissertations
The fit of the humeral prosthesis to the intramedullary canal and the replication of the anatomic humeral head center are important factors in Total Shoulder Arthroplasty (TSA). The objective of this thesis was to develop a Statistical Shape Model (SSM) of the cortical and cancellous bone regions of the proximal humerus, and to assess potential shape differences with gender and ethnicity, with a goal of informing implant design. An SSM was used and Principal Component Analysis (PCA) was applied to data that represented both the cancellous and cortical humeral bone of 63 healthy subjects and cadavers. Anatomical measurements and PC …
Shear Driven Micro-Fluidic Pump, Nihad E. Daidzic
Shear Driven Micro-Fluidic Pump, Nihad E. Daidzic
Aviation Department Publications
United States Patent, Patent Number US 9,528,503 B2, Date of Patent December 27, 2016.
An example includes an apparatus to pump a fluid. The apparatus includes a housing extending along a length defining an elongate interior, an actuator in the housing, conforming to the elongate interior, the actuator including a plurality of lumens, each having a length extending substantially parallel to the elongate interior, each from around 10 to 200 micrometers across and an actuator configured to oscillate the actuator in the actuator houslng along the length of the elongate interior with a rate differential between movement in a first …
Finite Element Simulation And Additive Manufacturing Of Stiffness-Matched Niti Fixation Hardware For Mandibular Reconstruction Surgery, Ahmadreza Jahadakbar, Narges Shayesteh Moghaddam, Amirhesam Amerinatanzi, David Dean, Haluk E. Karaca, Mohammad Elahinia
Finite Element Simulation And Additive Manufacturing Of Stiffness-Matched Niti Fixation Hardware For Mandibular Reconstruction Surgery, Ahmadreza Jahadakbar, Narges Shayesteh Moghaddam, Amirhesam Amerinatanzi, David Dean, Haluk E. Karaca, Mohammad Elahinia
Mechanical Engineering Faculty Publications
Process parameters and post-processing heat treatment techniques have been developed to produce both shape memory and superelastic NiTi using Additive Manufacturing. By introducing engineered porosity, the stiffness of NiTi can be tuned to the level closely matching cortical bone. Using additively manufactured porous superelastic NiTi, we have proposed the use of patient-specific, stiffness-matched fixation hardware, for mandible skeletal reconstructive surgery. Currently, Ti-6Al-4V is the most commonly used material for skeletal fixation devices. Although this material offers more than sufficient strength for immobilization during the bone healing process, the high stiffness of Ti-6Al-4V implants can cause stress shielding. In this paper, …
Design Of A Modified Stewart Platform Manipulator For Misalignment Correction, Adekunle Ayoko
Design Of A Modified Stewart Platform Manipulator For Misalignment Correction, Adekunle Ayoko
Master of Technology Management Plan II Graduate Projects
This thesis work is about the design of a modified Stewart platform manipulator for misalignment correction. The common version of the Stewart platform uses six actuators. The traditional Stewart platform of this kind has a moving top plate and a fixed base plate. However, in this research, the modified design of the traditional Stewart platform is studied. It is designed to be an easy connect-disconnect platform that can wrap around different structures with different cross sections and symmetrically designed. It is able to adjust position easily by using four identical but independent linear actuators populated evenly in two parts fastened …
A Validated Software Application To Measure Fiber Organization In Soft Tissue, Erica E. Morrill, Azamat N. Tulepbergenov, Christina J. Stender, Roshani Lamichhane, Raquel J. Brown, Trevor J. Lujan
A Validated Software Application To Measure Fiber Organization In Soft Tissue, Erica E. Morrill, Azamat N. Tulepbergenov, Christina J. Stender, Roshani Lamichhane, Raquel J. Brown, Trevor J. Lujan
Mechanical and Biomedical Engineering Faculty Publications and Presentations
The mechanical behavior of soft connective tissue is governed by a dense network of fibrillar proteins in the extracellular matrix. Characterization of this fibrous network requires the accurate extraction of descriptive structural parameters from imaging data, including fiber dispersion and mean fiber orientation. Common methods to quantify fiber parameters include fast Fourier transforms (FFT) and structure tensors, however, information is limited on the accuracy of these methods. In this study, we compared these two methods using test images of fiber networks with varying topology. The FFT method with a band-pass filter was the most accurate, with an error of 0.71 …
Final Design Report: Polymer Fatigue Characterization Test Method, Wyatt Ayling, Tyler Price, Brandon Stell, Michela Upson
Final Design Report: Polymer Fatigue Characterization Test Method, Wyatt Ayling, Tyler Price, Brandon Stell, Michela Upson
Mechanical Engineering
Polylogix is a team dedicated to the design, build, and testing of a fatigue machine to simulate cyclic loading on a biomedical polymer. This project is sponsored by Endologix, Inc. to provide test data characterizing mechanical material properties of various formulations of polymer used in abdominal aortic aneurysm surgeries. With this project goal, the machine must be able to test the polymer at body conditions; these include a testing temperature of 37°C and a cycling frequency ranging from 1 Hz to 10 Hz. This report proposes the following solution to this design challenge: an AC motor-driven mechanism utilizing a planetary …
Concurrent Detection And Isolation Of Cellular And Molecular Biomarkers, Wanfeng Huang
Concurrent Detection And Isolation Of Cellular And Molecular Biomarkers, Wanfeng Huang
Open Access Dissertations
Detection of cancer markers such as protein biomolecules and cancer cells in bodily fluids is of great importance in early diagnosis, prognosis as well as evaluation of therapy efficacy. Numerous devices have been developed for detecting either cellular or molecular targets, however there has not yet been a system that can simultaneously detect both cellular and molecular targets effectively. Molecule and cell-based assays are important because each type of target can tell a different story about the state of the disease and the two types of information can potentially be combined and/or compared for more accurate biological or clinical assessments. …