Open Access. Powered by Scholars. Published by Universities.®
Biomedical Engineering and Bioengineering Commons™
Open Access. Powered by Scholars. Published by Universities.®
- Institution
-
- California Polytechnic State University, San Luis Obispo (213)
- Missouri University of Science and Technology (131)
- University of Arkansas, Fayetteville (70)
- The University of Akron (48)
- University of Nebraska - Lincoln (45)
-
- Purdue University (39)
- University of Nevada, Las Vegas (32)
- Technological University Dublin (27)
- Marquette University (26)
- City University of New York (CUNY) (25)
- Dartmouth College (25)
- University of Kentucky (25)
- Old Dominion University (24)
- Virginia Commonwealth University (22)
- University of Louisville (21)
- Clemson University (20)
- University of Mississippi (19)
- University of Connecticut (17)
- Kettering University (16)
- Michigan Technological University (15)
- University of Denver (14)
- University of Malaya (12)
- Brigham Young University (11)
- West Virginia University (11)
- Louisiana State University (10)
- Washington University in St. Louis (10)
- Duquesne University (9)
- Embry-Riddle Aeronautical University (9)
- Cleveland State University (7)
- Georgia Southern University (7)
- Keyword
-
- Microfluidics (34)
- Biomechanics (14)
- Biomedical Engineering (14)
- Biomedical (13)
- Biomedical engineering (13)
-
- Daniel Felix Ritchie School of Engineering and Computer Science (13)
- Machine learning (12)
- Prosthetic (12)
- Cancer (11)
- Device (11)
- Engineering (11)
- Machine Learning (11)
- Prosthetics (11)
- Medical device (10)
- Surgery (10)
- Biomaterials (9)
- Electrophysiology (9)
- Kinematics (9)
- 3D printing (8)
- Applied sciences (8)
- Biosensor (8)
- Diagnostics (8)
- Gait (8)
- Mechanical and Materials Engineering (8)
- Sensor (8)
- Ultrasound (8)
- Wearable (8)
- Arduino (7)
- Bone (7)
- Breast cancer (7)
- Publication Year
- Publication
-
- Chemical and Biochemical Engineering Faculty Research & Creative Works (131)
- Master's Theses (98)
- Biomedical Engineering (79)
- Williams Honors College, Honors Research Projects (47)
- Electronic Theses and Dissertations (42)
-
- Graduate Theses and Dissertations (32)
- The Summer Undergraduate Research Fellowship (SURF) Symposium (30)
- UNLV Theses, Dissertations, Professional Papers, and Capstones (28)
- Biomedical Engineering Undergraduate Honors Theses (26)
- Theses and Dissertations (25)
- Honors Theses (22)
- Mechanical Engineering (22)
- Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research (17)
- Master's Theses (2009 -) (17)
- Theses and Dissertations--Biomedical Engineering (17)
- Conference Papers (16)
- Dissertations, Master's Theses and Master's Reports (15)
- Dissertations and Theses (12)
- Student Works (2020-2029) (12)
- All Dissertations (11)
- Dartmouth College Ph.D Dissertations (11)
- Graduate Theses, Dissertations, and Problem Reports (ETD) (11)
- Mechanical Engineering Patents (11)
- Biomedical Engineering Western Regional Conference (10)
- McKelvey School of Engineering Graduate Student Theses & Dissertations (10)
- Publications and Research (10)
- All Theses (9)
- Dissertations (1934 -) (9)
- Honors Scholar Theses (8)
- Department of Agricultural and Biological Systems Engineering: Dissertations, Theses, and Student Research (7)
- Publication Type
- File Type
Articles 451 - 480 of 1153
Full-Text Articles in Biomedical Engineering and Bioengineering
A Centralised Multi-Objective Model Predictive Control For Biventricular Assist Devices, Vivian Koh Ci Ai
A Centralised Multi-Objective Model Predictive Control For Biventricular Assist Devices, Vivian Koh Ci Ai
Student Works (2020-2029)
Heart failure is defined as failure of heart to deliver adequate blood flow rate to support tissue perfusion. Heart failure can be treated by implantation of a left ventricular assist device (LVAD) for left heart failure patients, or a biventricular assist device (BiVAD) for bi-heart failure patients. Since left heart failure predominates right heart failure, all commercial ventricular assist devices are LVADs. Therefore, two LVADs are frequently used as BiVAD for bi-heart failure patients. Clinically, the constant speed (CS) control of BiVAD fails to adapt pump flow rate according to physiological changes, thus putting patients at risk of ventricular suction …
An Affordable And Portable Palpable System For Sensing Breast Tissue Abnormalities, Cody J. Clarke
An Affordable And Portable Palpable System For Sensing Breast Tissue Abnormalities, Cody J. Clarke
Montview Journal of Research & Scholarship
Due to the high cost of equipment and lack of trained personnel, manual palpation is a preferred alternative breast examination technique over mammography. The process involves a thorough search pattern using trained fingers and applying adequate pressure, with the objective of identifying solid masses from the surrounding breast tissue. However, palpation requires skills that must be obtained through adequate training in order to ensure proper diagnosis. Consequently, palpation performance and reporting techniques have been inconsistent. Automating the palpation technique would optimize the performance of self-breast examination, optimize clinical breast examinations (CBE), and enable the visualization of breast abnormalities as well …
Immediate Effects Of Dynamic Lycra® Orthosis On Sitting To Standing Ability Children With Cerebral Palsy / Ida Hasni Shaari, Ida Hasn Shaari
Immediate Effects Of Dynamic Lycra® Orthosis On Sitting To Standing Ability Children With Cerebral Palsy / Ida Hasni Shaari, Ida Hasn Shaari
Student Works (2020-2029)
Children with Cerebral Palsy (CP) are highly exposed to postural mal-alignment which interrupt their functional movement pattern and the ability to attain certain functional activities, like walking and Children with Cerebral Palsy (CP) are highly exposed to postural mal-alignment which interrupt their functional movement pattern and the ability to attain certain functional activities, like walking and sitting-to-standing motion (STS). Orthoses are commonly prescribed to give good posture in these children. Yet, none of the orthoses has been found to be suitable in addressing trunkpelvis alignment in children with cerebral palsy, to enhance their STS performance. Therefore, this study was conducted …
Bacteria Analysis By Using A Supervised Machine Learning Algorithm Based On Droplet Microfluidics, Yulder Daniel Angarita
Bacteria Analysis By Using A Supervised Machine Learning Algorithm Based On Droplet Microfluidics, Yulder Daniel Angarita
Electronic Theses and Dissertations
Sepsis is a major medical problem and massive resources have been invested in developing and evaluating alternative treatments. Statistics indicate that sepsis causes between one third and one half of all hospital deaths in the United States. Sepsis has a high impact on health care in the US, with direct sepsis costs in 2009 exceeding $15.4 billion. A research study found that a 1-hour delay in appropriate antimicrobial care resulted in a 7% - 10% rise in mortality. Several professional societies seek to reduce sepsis mortality by targeting the timely use of diagnostic tests and antimicrobial therapy. The diagnostic instruments …
Detection Of Standing And Sitting Variations Based On In-Socket Piezoelectric Sensors For Transfemoral Amputees, Alnusairi Tawfik Yahya
Detection Of Standing And Sitting Variations Based On In-Socket Piezoelectric Sensors For Transfemoral Amputees, Alnusairi Tawfik Yahya
Student Works (2020-2029)
A transfemoral prosthesis is required to assist amputees to perform activities of daily living (ADL). The purely mechanical or passive prosthesis has some drawbacks such as consumption of high metabolic energy and limitations in mimicking normal dynamics and kinematics of gait pattern. In contrast, the active prosthesis offers better performance and consumes less metabolic energy. However, recent active prosthesis uses surface electromyography as its sensory system which requires massive preparation work, causes sores to the patient by its electrodes and requires a lot of computation to extract meaningful features. This thesis focuses on developing signal conditioning circuitry to classify six …
3-Dimensional Carbon Micro-Electro Mechanical System (Mems) Electrode For Potential Dielectrophoretic Hepatic Cell Patterning Application, Wan Yahya Wan Nurlina
3-Dimensional Carbon Micro-Electro Mechanical System (Mems) Electrode For Potential Dielectrophoretic Hepatic Cell Patterning Application, Wan Yahya Wan Nurlina
Student Works (2020-2029)
The maintenance of liver tissue unique pattern remains a great challenge in the generation of functional engineered liver tissue in vitro. This thesis presents a carbon dielectrophoresis (DEP) based cell patterning for generating hepatic cell constructs, mimicking biological hepatic lobule. A new design of electrode named interdigitated radiating-strips electrode (IRSE) was simulated and optimized using COMSOL Multiphysics 4.2a. The simulation result proved that IRSE is capable to provide uniform distribution of electric field for generating three-dimensional (3D) DEP force. The use of carbon electrodes has been an alternative to traditional metal electrodes and insulator structures for DEP applications since more …
Machine Learning Approaches For Fracture Risk Assessment: A Comparative Analysis Of Genomic And Phenotypic Data In 5130 Older Men, Qing Wu, Fatma Nasoz, Jongyun Jung, Bibek Bhattarai, Mira V. Han
Machine Learning Approaches For Fracture Risk Assessment: A Comparative Analysis Of Genomic And Phenotypic Data In 5130 Older Men, Qing Wu, Fatma Nasoz, Jongyun Jung, Bibek Bhattarai, Mira V. Han
School of Public Health Faculty Research
The study aims were to develop fracture prediction models by using machine learning approaches and genomic data, as well as to identify the best modeling approach for fracture prediction. The genomic data of Osteoporotic Fractures in Men, cohort Study (n = 5130), were analyzed. After a comprehensive genotype imputation, genetic risk score (GRS) was calculated from 1103 associated Single Nucleotide Polymorphisms for each participant. Data were normalized and split into a training set (80%) and a validation set (20%) for analysis. Random forest, gradient boosting, neural network, and logistic regression were used to develop prediction models for major osteoporotic fractures …
Automatic Detection Of Dynamic And Static Activities Of The Older Adults Using A Wearable Sensor And Support Vector Machines, Jian Zhang, Rahul Soangra, Thurmon E. Lockhart
Automatic Detection Of Dynamic And Static Activities Of The Older Adults Using A Wearable Sensor And Support Vector Machines, Jian Zhang, Rahul Soangra, Thurmon E. Lockhart
Physical Therapy Faculty Articles and Research
Although Support Vector Machines (SVM) are widely used for classifying human motion patterns, their application in the automatic recognition of dynamic and static activities of daily life in the healthy older adults is limited. Using a body mounted wireless inertial measurement unit (IMU), this paper explores the use of an SVM approach for classifying dynamic (walking) and static (sitting, standing and lying) activities of the older adults. Specifically, data formatting and feature extraction methods associated with IMU signals are discussed. To evaluate the performance of the SVM algorithm, the effects of two parameters involved in SVM algorithm—the soft margin constant …
How Does Robotic Surgery Influence Communication, Leadership, And Team Outcomes? A Multimethod Examination., Jordan E. Rogers
How Does Robotic Surgery Influence Communication, Leadership, And Team Outcomes? A Multimethod Examination., Jordan E. Rogers
Doctoral Dissertations and Master's Theses
The practice of delivering surgical care has evolved to be less invasive to the patients undergoing surgery. Minimally-invasive surgery can be practiced through traditional laparoscopic methods as well as with robotic technology that displaces the surgeon from the operating table. Robotic surgery has been cited to be safer and more effective than traditional laparoscopic surgery; however, little research has endeavored to investigate the role of surgical modality upon aspects of teamwork. This dissertation contributes to the human factors and teamwork literature by evaluating how surgical modality may influence communication, shared leadership, and team outcomes. Multiple methods were employed to study …
Utilizing Neural Networks And Wearables To Quantify Hip Joint Angles And Moments During Walking And Stair Ascent, Megan V. Mccabe
Utilizing Neural Networks And Wearables To Quantify Hip Joint Angles And Moments During Walking And Stair Ascent, Megan V. Mccabe
ENGS 88 Honors Thesis (AB Students)
Wearable sensors were leveraged to develop two methods for computing hip joint angles and moments during walking and stair ascent that are more portable than the gold standard. The Insole-Standard (I-S) approach replaced force plates with force-measuring insoles and achieved results that match the curvature of results from similar studies. Peaks in I-S kinetic results are high due to error induced by applying the ground reaction force to the talus. The Wearable-ANN (W-A) approach combines wearables with artificial neural networks to compute the same results. Compared against the I-S, the W-A approach performs well (average rRMSE = 18%, R2 …
Prosthetic Foot Shell, Ql+, Kathryn Victoria Versteeg, Jackson A. Tucker, Ethan William Frey
Prosthetic Foot Shell, Ql+, Kathryn Victoria Versteeg, Jackson A. Tucker, Ethan William Frey
Mechanical Engineering
This final design review includes an overview of our project and the steps we have taken to create our final product. We discuss the background research conducted, including various products like the foot shell we are trying to design and its related patents, along with similar past senior projects. As our product is considered a medical device, there are also certain standards that we must comply with. After determining our problem statement, we established what we believe to be the wants and needs of our user. These wants and needs were converted into specifications for our design, with durability as …
Alternative Epinephrine Auto-Injector, Joshua Wong, Uriel Nieves-Cruz, Tara Howard
Alternative Epinephrine Auto-Injector, Joshua Wong, Uriel Nieves-Cruz, Tara Howard
Biomedical Engineering
Project: Alternative Epinephrine Injector started as a solution for Bianca Aleman’s little brother however the scope has evolved to include the many millions of individuals across the world who struggle with a life-threatening allergen. The stakeholders of this project are Cal Poly and Dr. Michael D. Whitt. Our goals are the following:
● Develop a foolproof method of injection that consistently delivers a dosage of epinephrine
● Be equal or less than the current size of an EpiPen (6 in)
● Be easy to transport or store when not-in-use
● Create an isolated environment where the epinephrine will not be …
Virtual Stethoscope - Otoscope, Ermen J. Elenes-Cazares, Ceasar A. Hurtado, Thomas M. Margolle
Virtual Stethoscope - Otoscope, Ermen J. Elenes-Cazares, Ceasar A. Hurtado, Thomas M. Margolle
Biomedical Engineering
The purpose of this report was to develop a working prototype for a virtual stethoscope and otoscope. Sponsored by Courtney Farr, the virtual diagnostic care system – HouseCalls Mobile digital stethoscope/otoscope is meant for use by medical professionals and non – medical professionals for preliminary medical exams while physically not in a medical setting. The HouseCalls Mobile device is to characterize key biometric parameters such as breathing patterns, heart irregularities, and visual clinical evaluation of the inner ear. This device is intended for pediatric use.
Tmtt Chimera Valve Attachment Process, Paulina Nguyen, Devin Debouk, Tamar Kazazian, Noah Thompson
Tmtt Chimera Valve Attachment Process, Paulina Nguyen, Devin Debouk, Tamar Kazazian, Noah Thompson
Biomedical Engineering
No abstract provided.
Non-Invasive Peripheral Venous And Arterial Line Air Detector For Embolization Prevention, Alexandria Kwong, Kevin Shu, Dylan Meinster
Non-Invasive Peripheral Venous And Arterial Line Air Detector For Embolization Prevention, Alexandria Kwong, Kevin Shu, Dylan Meinster
Biomedical Engineering
The scope of this project includes designing a non-invasive bubble detector for peripheral venous and arterial lines. For minimally invasive cardiac procedures, arterial and venous access is necessary for these procedures as is constant flow through the tubing to prevent clotting and to administer drugs. Air bubbles are common in these lines and can be consequential if enough air is introduced into the human system. Air embolisms are the most common and relevant issues during these procedures. The goal of this device is to create an attachable detector for air bubbles in saline that can also terminate flow and alert …
Surf Sled, Marius Jatulis, Arthur Zaayer, Griffin O'Malley, Jose Covarrubias
Surf Sled, Marius Jatulis, Arthur Zaayer, Griffin O'Malley, Jose Covarrubias
Mechanical Engineering
This Final Design Review document outlines the process by which we designed and built a surfboard sled, nicknamed the “Beachin’ Buggy”, for the AmpSurf program. The document describes the goals and services that AmpSurf provides for those living with disabilities, and the current methods that volunteers use to transport people from to beach to the water and onto a surfboard. It then identifies the need for a new system for beach-to-water transportation, along with all specifications, constraints, and goals for the system. Background research will be introduced to relate similar products to this project, and their relevant features and parameters …
Concussion Detection Device, Jenna C. Sussex, Mark B. Edin, Bianca X. Aleman
Concussion Detection Device, Jenna C. Sussex, Mark B. Edin, Bianca X. Aleman
Biomedical Engineering
No abstract provided.
D.I.Y. Clean Hood, Samuel G. Porter, Ryan E. Shimogaki, Ryan S. Staples
D.I.Y. Clean Hood, Samuel G. Porter, Ryan E. Shimogaki, Ryan S. Staples
Biomedical Engineering
The DIY Clean Hood is a low-cost, sterile, and accessible scientific workspace intended for installation in the BioElectroFluidics Lab of California Polytechnic State University’s (San Luis Obispo) Biomedical Engineering Department (BMED), under the sponsorship of Dr. Benjamin Hawkins, PhD. As normal Clean Hood, Biosafety Cabinets, and the like are generally too expensive for a university, a competitive solution to an expensive problem can assist research students and professors alike continue their own work with an inexpensive yet effective environment.
Specific design elements that the customer requirements entailed for the project include a low-particle-count air filtration system, positive pressure air flow …
Sandy Feet, Garrett E. Herbst, Jacqueline Chuang, Jerin T. Brust, Parker S. Duncan
Sandy Feet, Garrett E. Herbst, Jacqueline Chuang, Jerin T. Brust, Parker S. Duncan
General Engineering
Sgt. Brady is a former armed forces member with a transtibial amputation. He walks on sand frequently for work and leisure, but experiences severe pain and inconvenience because his current prosthesis is not meant for use on sand. Sand Foot V2 is a prosthesis that allows Sgt. Brady to walk on sand for long periods of time without issue.
A Review Of The Latest Insights Into The Mechanism Of Action Of Strontium In Bone, Daniella Marx, Alireza Rahimnejad Yazdi, Marcello Papini, Mark R. Towler
A Review Of The Latest Insights Into The Mechanism Of Action Of Strontium In Bone, Daniella Marx, Alireza Rahimnejad Yazdi, Marcello Papini, Mark R. Towler
Chemical and Biochemical Engineering Faculty Research & Creative Works
Interest in strontium (Sr) has persisted over the last three decades due to its unique mechanism of action: it simultaneously promotes osteoblast function and inhibits osteoclast function. While this mechanism of action is strongly supported by in vitro studies and small animal trials, recent large-scale clinical trials have demonstrated that orally administered strontium ranelate (SrRan) may have no anabolic effect on bone formation in humans. Yet, there is a strong correlation between Sr accumulation in bone and reduced fracture risk in post-menopausal women, suggesting Sr acts via a purely physiochemical mechanism to enhance bone strength. Conversely, the local administration of …
The Role Of Poly(Methyl Methacrylate) In Management Of Bone Loss And Infection In Revision Total Knee Arthroplasty: A Review, Leyla Hasandoost, Omar Rodriguez, Adel Alhalawani, Paul Zalzal, Emil H. Schemitsch, Stephen D. Waldman, Marcello Papini, Mark R. Towler
The Role Of Poly(Methyl Methacrylate) In Management Of Bone Loss And Infection In Revision Total Knee Arthroplasty: A Review, Leyla Hasandoost, Omar Rodriguez, Adel Alhalawani, Paul Zalzal, Emil H. Schemitsch, Stephen D. Waldman, Marcello Papini, Mark R. Towler
Chemical and Biochemical Engineering Faculty Research & Creative Works
Poly (methyl methacrylate) (PMMA) is widely used in joint arthroplasty to secure an implant to the host bone. Complications including fracture, bone loss and infection might cause failure of total knee arthroplasty (TKA), resulting in the need for revision total knee arthroplasty (rTKA). The goals of this paper are: (1) to identify the most common complications, outside of sepsis, arising from the application of PMMA following rTKA, (2) to discuss the current applications and drawbacks of employing PMMA in managing bone loss, (3) to review the role of PMMA in addressing bone infection following complications in rTKA. Papers published between …
The Effect Of Distal Core Flattening And Heat Treatment On 304 Stainless Steel Guide Wires, Andrew Spencer Yap, Bryce Eric Veit, Matthew Frederick Lopez Villena
The Effect Of Distal Core Flattening And Heat Treatment On 304 Stainless Steel Guide Wires, Andrew Spencer Yap, Bryce Eric Veit, Matthew Frederick Lopez Villena
Materials Engineering
The mechanical response of 304 stainless steel guide wires due to different temper conditions and amounts of flattening is to be explored in this project. For this specific project, there is no public literature on the mechanical properties of guide wires with the above conditions through tensile testing or Turns to Failure Testing. To address this, the project with Abbott Vascular will measure the mechanical properties of guide wires using the aforementioned factors. Due to a lack of previous literature on this research topic, there are no quantitative goals for the project, however, any new research compiled in this area …
Septal Closure Device, Olivia N. Welch, Hillal H. Jarrar, Kai Harrison
Septal Closure Device, Olivia N. Welch, Hillal H. Jarrar, Kai Harrison
Biomedical Engineering
The septal closure device was designed to seal defects in the atrial septum. To fully seal an atrial defect, the device was designed to consist of two circular seals to cover the defect in both the right and left atria, attached with a central rod. The materials were chosen for compressibility (for ease of insertion), biocompatibility, and tissue ingrowth. A CAD model was drafted in SolidWorks. Key customer requirements include ease of implantation (specifications: adjustable sizing and clear directions for use), physician controlled (specifications: short implantation time and compatibility with current catheter/scope techniques), and a long lifetime (specifications: materials that …
Control And Locomotion Of Inertially And Magnetically Actuated Multi-Scale Robotic Systems, Ehab Al Khatib
Control And Locomotion Of Inertially And Magnetically Actuated Multi-Scale Robotic Systems, Ehab Al Khatib
Mechanical Engineering Research Theses and Dissertations
In this research, two actuation systems were introduced, inertial and magnetic actuation. In the inertial actuation, the robot used the transfer of momentum to navigate, and this momentum could be generated by spinning masses and wheels. Recent studies in our System Laboratory proved that a wide range of inertially actuated locomotion systems could be generated. This can be achieved by using a family tree approach, starting from a very simple system, and progressively evolving it to more complex ones. The motion diversity of these robots inspired us to extend their locomotion from a macro scale to millimeter and micro scales. …
Wearable Blood Pressure Device For Detection Of Orthostatic Hypotension, Mariam Hafez
Wearable Blood Pressure Device For Detection Of Orthostatic Hypotension, Mariam Hafez
Honors Scholar Theses
Orthostatic hypotension may be described as an inevitable response from the body in the form of a drop in blood pressure after changing positions. This quick drop in blood pressure can cause a syncopal episode, often injuring victims. There are limitations in the currently used cuff-type blood pressure sensor, which is used in healthcare settings, in that it does not continuously measure blood pressure. This research project developed a wearable device that measures heart rate variability (HRV) to detect changes in blood pressure using the correlation between the two measurements. The instrumentation was developed and included a commercially available pulse …
A Microfluidic Platform For High-Throughput Screening Of Aquaporin Performance, Adriana Del Pino Herrera, Jordan Hoydick, Rachel Rauh, Elyssa El-Hajj, Madison Burchfield
A Microfluidic Platform For High-Throughput Screening Of Aquaporin Performance, Adriana Del Pino Herrera, Jordan Hoydick, Rachel Rauh, Elyssa El-Hajj, Madison Burchfield
Undergraduate Research and Scholarship Symposium
Aquaporins are a family of small integral membrane proteins that transport water across cell membranes in response to osmotic gradients. They facilitate fluid secretion and absorption across epithelial surfaces in kidney tubules, exocrine glands, and gastrointestinal tract. Here, we describe a novel microfluidic method to evaluate and screen for aquaporin-based transmembrane permeability in mammalian cells. A microfluidic device was designed and fabricated for the encapsulation of single mammalian and yeast cells in micron-sized droplets. For this purpose, Chinese Hamster Ovarian (CHO) cells were used. CHO cells express AQP1 (aquaporin-1) homologous to human kidney aquaporins. The cells were cultivated and exposed …
Heel Down And Toe-Off Time Measured With Ultrasonic Doppler System And Force Plate Sensor, Sabin Timsina
Heel Down And Toe-Off Time Measured With Ultrasonic Doppler System And Force Plate Sensor, Sabin Timsina
Honors Theses
Collie Box is a medical device that measures the gait parameters of the person walk- ing in front of it. This device uses the Ultrasonic Doppler system to extract the heel-contact and toe-off times of a person walking within the range of 2-10 meters. These times are used to determine the leg’s swing phase and double stance times. The ultrasonic transducer of 10mm diameter is driven at 40kHz. At the time of the heel-contact and toe-off, foot velocity is zero while the torso part of the human body is still in motion. The wide directivity of 10mm diameter ultrasonic transducer …
Characterization Of Photoacoustic Flow Cytometry Signals, Craig Benzinger
Characterization Of Photoacoustic Flow Cytometry Signals, Craig Benzinger
Electronic Theses and Dissertations
Photoacoustic flow cytometry has been utilized to clinically determine the presence of melanoma circulating tumor cells (CTCs). Further investigation was conducted into the morphology of detection signals and how they could be manipulated to allow for further classification. Novel features were extracted from waveforms that appear to have strong classification ability. Neural networks were also used to determine classification potential and the creation of feature mapping for future unsupervised classification. Detections were expanded from single waves to a time dependent multiwave event. Waveforms were also determined to be of non-parametric distribution, allowing for classification by neural network but not allowing …
Rapid Antibiotic Susceptibility Testing Platform For Direct Clinical Samples, Terrance Zhang
Rapid Antibiotic Susceptibility Testing Platform For Direct Clinical Samples, Terrance Zhang
Honors Scholar Theses
Infectious diseases and septicemia are two of the major causes of death in the U.S., necessitating rapid treatment of septic patients with proper, efficacious antibiotics. Unfortunately, the emergence and spread of multidrug-resistant bacteria are continuously being aggravated by an abuse in antibiotic prescription at a clinical and agricultural level. It is known that antibiotic resistance evolves through the sequential accumulation of multiple mutations in bacteria, which is accentuated by prolonged exposure of bacteria to ineffective antibiotics when implementing traditional septicemia treatment. The goal of this project is to develop a novel, easy-to-use AST platform for rapid antimicrobial susceptibility profiling to …
Redesign And Quantitative Assessment Of An Accelerated Venous Valve Fatigue Apparatus, Megan Kueh
Redesign And Quantitative Assessment Of An Accelerated Venous Valve Fatigue Apparatus, Megan Kueh
Biomedical Engineering Undergraduate Honors Theses
Chronic venous insufficiency (CVI) is a form of cardiovascular disease that is caused when valves in the leg become incompetent. Current treatment methods serve to manage symptoms, but there are currently no ways to treat the underlying cause of CVI. A venous valve prosthetic made from a xenograft of a bovine jugular vein is one possible treatment method currently in the research phase. Prosthetic valves must be tested with an accelerated wear tester prior to approval for clinical testing. Although such testers exist for heart valves, physiological differences between heart and venous valves restrict the use those testers on venous …