Open Access. Powered by Scholars. Published by Universities.®
Biomedical Engineering and Bioengineering Commons™
Open Access. Powered by Scholars. Published by Universities.®
- Institution
-
- Old Dominion University (61)
- California Polytechnic State University, San Luis Obispo (29)
- University of Nevada, Las Vegas (27)
- University of Arkansas, Fayetteville (13)
- Chapman University (9)
-
- Technological University Dublin (9)
- Purdue University (8)
- Ateneo de Manila University (5)
- Harrisburg University of Science and Technology (5)
- Kennesaw State University (5)
- Louisiana State University (5)
- University of Nebraska - Lincoln (5)
- Dartmouth College (4)
- San Jose State University (4)
- The University of Akron (4)
- University of Denver (4)
- University of Louisville (4)
- City University of New York (CUNY) (3)
- Georgia Southern University (3)
- Liberty University (3)
- Michigan Technological University (3)
- New Jersey Institute of Technology (3)
- Southern Methodist University (3)
- University of Connecticut (3)
- University of Malaya (3)
- University of North Florida (3)
- University of Texas at Tyler (3)
- Brigham Young University (2)
- Clemson University (2)
- University of Central Florida (2)
- Keyword
-
- Electroporation (8)
- Electric fields (7)
- Medical imaging (7)
- Machine Learning (6)
- Machine learning (6)
-
- Cells (5)
- Signal processing (5)
- Biomedical engineering (4)
- EEG (4)
- Electro-larynx (4)
- Federated learning (4)
- Intelligibility (4)
- Magnetic resonance imaging (4)
- Nanoparticles (4)
- Piezoelectric (4)
- Tissue engineering (4)
- Tissues (4)
- Tracking (4)
- Arduino (3)
- Biochemical markers (3)
- Biomedical (3)
- Biopsy (3)
- Biosensor (3)
- Biosensors (3)
- Brain (3)
- Cancer (3)
- Computer aided diagnosis (3)
- Daniel Felix Ritchie School of Engineering and Computer Science (3)
- Deep learning (3)
- Drug delivery (3)
- Publication Year
- Publication
-
- UNLV Theses, Dissertations, Professional Papers, and Capstones (24)
- Electrical & Computer Engineering Theses & Dissertations (22)
- Master's Theses (17)
- Electrical & Computer Engineering Faculty Publications (16)
- Bioelectrics Publications (11)
-
- Engineering Faculty Articles and Research (9)
- Conference Papers (8)
- Electronic Theses and Dissertations (7)
- Graduate Theses and Dissertations (7)
- Electrical Engineering (6)
- The Summer Undergraduate Research Fellowship (SURF) Symposium (6)
- Dissertations (5)
- Faculty Works (5)
- Biomedical Engineering (4)
- LSU Doctoral Dissertations (4)
- Symposium of Student Scholars (4)
- Williams Honors College, Honors Research Projects (4)
- Ateneo Laboratory for Intelligent Visual Environments (3)
- Biomedical Engineering Theses & Dissertations (3)
- College of Graduate Studies: Theses & Dissertations (3)
- Dartmouth College Ph.D Dissertations (3)
- Dissertations and Theses (3)
- Dissertations, Master's Theses and Master's Reports (3)
- Electrical Engineering Theses (3)
- School of Medical Diagnostics & Translational Sciences Publications (3)
- Student Works (2020-2029) (3)
- Theses and Dissertations (3)
- UNF Graduate Theses and Dissertations (3)
- Biomedical Engineering Undergraduate Honors Theses (2)
- Computer Engineering (2)
- Publication Type
Articles 211 - 240 of 270
Full-Text Articles in Biomedical Engineering and Bioengineering
Temporal Modulation Of Plasma Species In Atmospheric Dielectric Barrier Discharges, Aijun Yang, Xiaohua Wang, Dingxin Liu, Mingzhe Rong, Michael G. Kong
Temporal Modulation Of Plasma Species In Atmospheric Dielectric Barrier Discharges, Aijun Yang, Xiaohua Wang, Dingxin Liu, Mingzhe Rong, Michael G. Kong
Bioelectrics Publications
The atmospheric pressure dielectric barrier discharge in helium is a pulsed discharge in nature and the moment of maximum species densities is almost consistent with peak discharge current density. In this paper, a one-dimensional fluid model is used to investigate the temporal structure of plasma species in an atmospheric He-N2 dielectric barrier discharge (DBD). It is demonstrated that there exist microsecond delays of the moments of the maximum electron and ion densities from the peak of discharge current density. These time delays are caused by a competition between the electron impact and Penning ionizations, modulated by the N2 …
A Quantitative Analysis Of A Paper-Based, Laser-Defined, Oxygen-Generating Platform For Chronic Wounds, Tiffany L. Huang, Babak Ziaie
A Quantitative Analysis Of A Paper-Based, Laser-Defined, Oxygen-Generating Platform For Chronic Wounds, Tiffany L. Huang, Babak Ziaie
The Summer Undergraduate Research Fellowship (SURF) Symposium
Chronic wounds affect 6.5 million patients a year while consuming US$25 billion in health care costs (Sen 2009 Wound Repair Regen.). Despite advances in wound management therapies, modern treatment for chronic wounds still requires continual professional attention and expensive equipment, posing serious practical and financial burdens for the regular patient. To provide an alternative solution, we are developing a low-cost smart bandage platform that integrates actuators and sensors to monitor and treat chronic wounds. One component of the integrated platform is an oxygen-generating module. It is a polydimethylsiloxane (PDMS) based microfluidic device fabricated on a parchment paper substrate that …
Computational Modeling To Evaluate Helical Electrode Designs For Use In Vagus Nerve Stimulation, Anthony W. Cowley
Computational Modeling To Evaluate Helical Electrode Designs For Use In Vagus Nerve Stimulation, Anthony W. Cowley
Master's Theses
An estimated 0.5% of world’s population has been diagnosed with epilepsy. Of these patients 20-30% will be unable to achieve seizure control with anti-epileptic drugs. Vagus nerve stimulation (VNS) may be an appropriate treatment option for some patients with pharmaceutically refractory, partial-onset seizures.
VNS therapy uses a helical electrode to interface between the implantable pulse generator and the vagus nerve. While there have been several studies related to the mechanical and electrical safety of such electrodes, little work has been done toward understanding the effectiveness of the helical electrode in nerve stimulation. A better understanding of the voltage field and …
Design And Testing Of Novel Mouthguard With Intermediate Nitinol And Foam Layers, Adam Kessler
Design And Testing Of Novel Mouthguard With Intermediate Nitinol And Foam Layers, Adam Kessler
UNLV Theses, Dissertations, Professional Papers, and Capstones
It is the aim of this study to investigate a novel mouthguard design that incorporates the use of a nickel-titanium (Nitinol) layer and thin foam layer in addition to EVA layers. It is thought that the Nitinol layer can distribute the force of an impact and that the thin foam layer may absorb this distributed force better than a solid EVA mouthguard of the same thickness. Rectangular, flat coupons representative of several mouthguard configurations were constructed for testing using an instrumented drop-weight impact tower. The coupon configurations include a control made of laminated EVA, a group of laminated EVA and …
Closed Loop Control Of A Cylindrical Tube Type Ionic Polymer Metal Composite (Ipmc), Benjamin Mead
Closed Loop Control Of A Cylindrical Tube Type Ionic Polymer Metal Composite (Ipmc), Benjamin Mead
UNLV Theses, Dissertations, Professional Papers, and Capstones
The goal of this research is to provide a framework for the integration of tube type, cylindrical Ionic Polymer Metal-Composite (IPMC) into conventional devices. IPMCs are one of the most widely used types of electro-active polymer actuator, due to their low electric driving potential and large deformation range. For this research a tube type IPMC was investigated. This IPMC has a circular cross section with four separate electrodes on its surface and a hole through the middle. The four electrodes allow for biaxial bending and accurate control of the tip location. One of the main advantages of using this type …
Subnanosecond Exposure Systems For Biological Studies, Jongbong Nah
Subnanosecond Exposure Systems For Biological Studies, Jongbong Nah
Electrical & Computer Engineering Theses & Dissertations
The research of bioelectrics has expanded to subnanosecond pulse region and entered a new domain of biophysics of cell interaction with ultra-short and intense electric fields. As subnanosecond pulses may be delivered by antennas to the human body and is very attractive to the medical community, the study of subnanosecond pulse effects calls for exposure systems for both cells and tissues. Two systems were designed in the scope of this thesis, used for cells and tissues respectively. The exposure system designed for cell exposure is a cuvette consisting of two parallel aluminum gaps. This cuvette is placed in a coaxial …
A Wireless And Digital Electrode Bus Topology For Biopotential Measurement, Mark Nolan, Edward Burke, Eugene Coyle
A Wireless And Digital Electrode Bus Topology For Biopotential Measurement, Mark Nolan, Edward Burke, Eugene Coyle
Conference Papers
The conventional biopotential measurement configuration utilises long lead wires which connect measuring electrodes to signal conditioning circuitry. The majority of bioelectric signals that are measured from the human body have a tiny signal amplitude (5µV-5mV range) and thus any interference that is induced on the lead wires can have a detrimental effect on the original signal. In this paper, we present an alternative configuration, in which digitisation occurs on the electrode, potentially providing enhanced signal measurement as well as significant benefits in terms of the simplification of the physical interconnections between electrodes. Multiple electrodes are combined to form a digital …
Polygrasp: Reach; Myoelectric Prosthetic Hand Iteration, Devon Patrick Augustus, Mighells Blaed Deuel, Ian Noel Fraser, Nicholas Philip Moesser
Polygrasp: Reach; Myoelectric Prosthetic Hand Iteration, Devon Patrick Augustus, Mighells Blaed Deuel, Ian Noel Fraser, Nicholas Philip Moesser
Mechanical Engineering
Amputations are a common occurrence in soldiers returning home who have suffered the effects of IED and munitions explosions. For upper limb amputees, trans-radial amputations are the most common. Traditional hook devices do not offer an adequate level of normalcy for users, prompting the use of myoelectric devices. While current myoelectric devices do offer a more natural experience, they come with a host of other problems that makes their adoption by service personnel not desirable or not permitted by the VA. PolyGrasp Reach seeks to reduce weight and cost and improve performance. This addresses several of the issues with devices …
The Presence Of Regional Accents In Electrolarynx Speech And The Resultant Effect On Overall Intelligibility., Brian Madden, Eugene Coyle
The Presence Of Regional Accents In Electrolarynx Speech And The Resultant Effect On Overall Intelligibility., Brian Madden, Eugene Coyle
Conference Papers
During voiced speech, the larynx provides quasi-periodic acoustic excitation of the vocal tract. In most electrolarynxes, mechanical vibrations are produced by a linear electromechanical actuator, the armature of which percusses against a metal or plastic plate at a frequency within the range of glottal excitation. In this paper, a phonological analysis of a section of results from an online perceptual intelligibility test was performed which compared speech produced using a novel hands-free electrolarynx and a commercially available electrolarynx. A portion of the test consisted of a closed-set format containing a selection of four sets of four random CVC audio samples …
The Use Of An In Vitro 3d Melanoma Model To Predict In Vivo Plasmid Transfection Using Electroporation, Benadette Marrero, Richard Heller
The Use Of An In Vitro 3d Melanoma Model To Predict In Vivo Plasmid Transfection Using Electroporation, Benadette Marrero, Richard Heller
Bioelectrics Publications
A large-scale in vitro 3D tumor model was generated to evaluate gene delivery procedures in vivo. This 3D tumor model consists of a "tissue-like" spheroid that provides a micro-environment supportive of melanoma proliferation, allowing cells to behave similarly to cells in vivo. This functional spheroid measures approximately 1 cm in diameter and can be used to effectively evaluate plasmid transfection when testing various electroporation (EP) electrode applicators. In this study, we identified EP conditions that efficiently transfect green fluorescent protein (GFP) and interleukin 15 (IL-15) plasmids into tumor cells residing in the 3D construct. We found that plasmids …
Assessing The Therapeutic Effect Of 630 Nm Light-Emitting Diodes Irradiation On The Recovery Of Exercise-Induced Hand Muscle Fatigue With Surface Electromyogram, Dandan Yang, Xiaoying Wu, Wensheng Hou, Xiaolin Zheng, Jun Zheng, Yingtao Jiang
Assessing The Therapeutic Effect Of 630 Nm Light-Emitting Diodes Irradiation On The Recovery Of Exercise-Induced Hand Muscle Fatigue With Surface Electromyogram, Dandan Yang, Xiaoying Wu, Wensheng Hou, Xiaolin Zheng, Jun Zheng, Yingtao Jiang
Electrical & Computer Engineering Faculty Research
This paper aims to investigate the effect of light emitting diode therapy (LEDT) on exercise-induced hand muscle fatigue by measuring the surface electromyography (sEMG) of flexor digitorum superficialis. Ten healthy volunteers were randomly placed in the equal sized LEDT group and control group. All subjects performed a sustained fatiguing isometric contraction with the combination of four fingertips except thumb at 30% of maximal voluntary contraction (MVC) until exhaustion. The active LEDT or an identical passive rest therapy was then applied to flexor digitorum superficialis. Each subject was required to perform a re-fatigue task immediately after therapy which was the same …
Cyberknife Radiation Modeling: Effects Of Relaxed Translational And Rotational Constraints On Healthy Tissue Irradiation, Sudha Bhavaroop Potineni
Cyberknife Radiation Modeling: Effects Of Relaxed Translational And Rotational Constraints On Healthy Tissue Irradiation, Sudha Bhavaroop Potineni
Electrical & Computer Engineering Theses & Dissertations
The Cyberknife system is a robotic radio surgery instrument that is used to treat cancers in different parts of the human body. Because of its accuracy and precision, it has become one of the best radio surgery systems in the world. However, even with Cyberknife the treatment time for one session takes from 30 minutes up to 120 minutes depending on the size, shape, and position of the tumor in the human body. In this research, a solution is presented to aid in reducing this long treatment time. An algorithm is developed which simulates the amount of the healthy tissue …
Heart-Rate Monitoring Control System Using Photoplethysmography (Ppg), Wesley Nguyen, Ryan Horjus
Heart-Rate Monitoring Control System Using Photoplethysmography (Ppg), Wesley Nguyen, Ryan Horjus
Electrical Engineering
No abstract provided.
Universal Engineering Programmer – An In-House Development Tool For Developing And Testing Implantable Medical Devices In St. Jude Medical, Khoa Tat Do
Master's Theses
During development and testing of the functionality of the pacemaker and defibrillator device, engineers in the St. Jude Medical Cardiac Rhythm Management Division use an in-house development tool called Universal Engineering Programmer (UEP) to ensure the device functions as expected, before it can be used to test on an animal or a human during the implantation process. In addition, some applications of UEP are incorporated into the official releases of the device product. UEP has been developed and used by engineers across departments in the St. Jude Medical Cardiac Rhythm Management Division (CRMD). This thesis covers the flexible and reusable …
Radio-Frequency Breast Cancer Imaging Results For A Simplified Cylindrical Phantom, Giuseppe Ruvio, Raffaele Solimene, Antonietta D'Alterio, Max Ammann, Rocco Pierri
Radio-Frequency Breast Cancer Imaging Results For A Simplified Cylindrical Phantom, Giuseppe Ruvio, Raffaele Solimene, Antonietta D'Alterio, Max Ammann, Rocco Pierri
Conference Papers
Microwave imaging is a pervasive research field and
is useful in numerous applicative diagnostic noninvasive contexts. This paper focuses on two aspects. First, we perform a numerical investigation to assess the role played by fundamental parameters (i.e. number of sensors, operating frequency bandwidth) on cancer detection. To this end, a simplified cylindrical phantom probed by ideal two-dimensional dipoles (i.e. infinitely long along the axis of invariance) is considered. Second, in order to focus on the role of the antennas, we analyze, still by numerical simulations and for a simplified breast model, how performances vary when a realistic antenna is adopted.
Sar Map Of Gel Phantom In A 64mhz Mri Birdcage By Fiber-Optic Thermometry And Fdtd Simulation, Chirag Mukesh Patel
Sar Map Of Gel Phantom In A 64mhz Mri Birdcage By Fiber-Optic Thermometry And Fdtd Simulation, Chirag Mukesh Patel
Master's Theses
As implantable medical devices are being used more often to treat medical problems for which pharmaceuticals don’t suffice, it is important to understand their interactions with commonly used medical modalities. The interactions between medical implants and Magnetic Resonance Imaging machines have proven to be a risk for patients with implants.
Implanted medical devices with elongated metallic components can create harmful levels of local heating in a Magnetic Resonance Imaging (MRI) environment [1]. The heating of a biological medium under MRI is monitored via the Specific Absorption Rate (SAR). SAR, defined as power absorbed per unit mass (W/kg), can be calculated …
Novel Bioelectrical Measurement Using A Digital Biopotential Monode, Mark Nolan, Edward Burke, Eugene Coyle
Novel Bioelectrical Measurement Using A Digital Biopotential Monode, Mark Nolan, Edward Burke, Eugene Coyle
Conference Papers
In conventional biopotential recording, two or more electrodes are placed on the body. A unipolar lead records the time-varying electrical potential at a single point (relative to a reference potential) via one signal electrode. A bipolar lead records the time-varying potential difference between two points via two signal electrodes. In each case, the signal electrodes are connected to high impedance amplifier inputs, while an additional electrode provides a low-impedance path between the amplifier and human subject. Bipolar leads are usually preferred since interference appearing at both signal electrodes can be eliminated using an instrumentation amplifier with high CMRR. A drawback …
Intelligibility Of Electrolarynx Speech Using A Novel Hands-Free Actuator, Brian Madden, Mark Nolan, Ted Burke, James Condron, Eugene Coyle
Intelligibility Of Electrolarynx Speech Using A Novel Hands-Free Actuator, Brian Madden, Mark Nolan, Ted Burke, James Condron, Eugene Coyle
Conference Papers
During voiced speech, the larynx provides quasi-periodic acoustic excitation of the vocal tract. In most electrolarynxes, mechanical vibrations are produced by a linear electromechanical actuator, the armature of which percusses against a metal or plastic plate at a frequency within the range of glottal excitation. In this paper, the intelligibility of speech produced using a novel hands-free actuator is compared to speech produced using a conventional electrolarynx. Two able-bodied speakers (one male, one female) performed a closed response test containing 28 monosyllabic words, once using a conventional electrolarynx and a second time using the novel design. The resulting audio recordings …
Augmented Control Of A Hands-Free Electrolarynx, Brian Madden, James Condron, Eugene Coyle
Augmented Control Of A Hands-Free Electrolarynx, Brian Madden, James Condron, Eugene Coyle
Conference Papers
During voiced speech, the larynx acts as the sound source, providing a quasi-periodic excitation of the vocal tract. Following a total laryngectomy, some people speak using an electrolarynx which employs an electromechanical actuator to perform the excitatory function of the absent larynx. Drawbacks of conventional electrolarynx designs include the monotonic sound emitted, the need for a free-hand to operate the device, and the difficulty experienced by many laryngectomees in adapting to its use. One improvement to the electrolarynx, which clinicians and users frequently suggest, is the provision of a convenient hands-free control facility. This would allow more natural use of …
On Improving Electrooculogram-Based Computer Mouse Systems: The Accelerometer Trigger, Johnalan Keegan, Edward Burke, James Condron, Eugene Coyle
On Improving Electrooculogram-Based Computer Mouse Systems: The Accelerometer Trigger, Johnalan Keegan, Edward Burke, James Condron, Eugene Coyle
Conference Papers
Eye tracking is a well-established method of computer control for profoundly paralysed people (Anson et al., 2002). Cameras are commonly used to track eye movements (Morimoto et al., 2005) but one alternative is the bioelectrical signal known as the electrooculogram (EOG). There are some EOG mouse control systems that facilitate the use of GUI applications, but certain actions, which are straightforward using a conventional mouse, remain impossible. Unless the eyes are tracking a target, they move in saccades (jumps), making it impossible to voluntarily trace out smooth trajectories with one's gaze, as would be required to draw a smooth curve. …
Bcc Skin Cancer Diagnosis Based On Texture Analysis Techniques, Shao-Hui Chuang, Xiaoyan Sun, Wen-Yu Chang, Gwo-Shing Chen, Adam Huang, Jiang Li, Frederic D. Mckenzie
Bcc Skin Cancer Diagnosis Based On Texture Analysis Techniques, Shao-Hui Chuang, Xiaoyan Sun, Wen-Yu Chang, Gwo-Shing Chen, Adam Huang, Jiang Li, Frederic D. Mckenzie
Electrical & Computer Engineering Faculty Publications
In this paper, we present a texture analysis based method for diagnosing the Basal Cell Carcinoma (BCC) skin cancer using optical images taken from the suspicious skin regions. We first extracted the Run Length Matrix and Haralick texture features from the images and used a feature selection algorithm to identify the most effective feature set for the diagnosis. We then utilized a Multi-Layer Perceptron (MLP) classifier to classify the images to BCC or normal cases. Experiments showed that detecting BCC cancer based on optical images is feasible. The best sensitivity and specificity we achieved on our data set were 94% …
On The Visual Quality Enhancement Of Super-Resolution Images, Amr Hussein Yousef, Jiang Li, Mohammad Karim, Andrew G. Tescher (Ed.)
On The Visual Quality Enhancement Of Super-Resolution Images, Amr Hussein Yousef, Jiang Li, Mohammad Karim, Andrew G. Tescher (Ed.)
Electrical & Computer Engineering Faculty Publications
Super-resolution (SR) is the process of obtaining a higher resolution image from a set of lower resolution (LR) blurred and noisy images. One may, then, envision a scenario where a set of LR images is acquired with a sensor on a moving platform. In such a case, an SR image can be reconstructed in an area of sufficient overlap between the LR images which generally have a relative shift with respect to each other by subpixel amounts. The visual quality of the SR image is affected by many factors such as the optics blur, the inherent signalto- noise ratio of …
A Monocular Marker-Free Gait Measurement System, Jane Courtney, Annraoi M. De Paor
A Monocular Marker-Free Gait Measurement System, Jane Courtney, Annraoi M. De Paor
Articles
This paper presents a new, user-friendly, portable motion capture and gait analysis system for capturing and analyzing human gait, designed as a telemedicine tool to monitor remotely the progress of patients through treatment. The system requires minimal user input and simple single-camera filming (which can be acquired from a basic webcam) making it very accessible to nontechnical, nonclinical personnel. This system can allow gait studies to acquire a much larger data set and allow trained gait analysts to focus their skills on the interpretation phase of gait analysis. The design uses a novel motion capture method derived from spatiotemporal segmentation …
Application Of Signal Advance Technology To Electrophysiology, Chris M. Hymel
Application Of Signal Advance Technology To Electrophysiology, Chris M. Hymel
Dissertations and Theses (Open Access)
Medical instrumentation used in diagnosis and treatment relies on the accurate detection and processing of various physiological events and signals. While signal detection technology has improved greatly in recent years, there remain inherent delays in signal detection/ processing. These delays may have significant negative clinical consequences during various pathophysiological events. Reducing or eliminating such delays would increase the ability to provide successful early intervention in certain disorders thereby increasing the efficacy of treatment.
In recent years, a physical phenomenon referred to as Negative Group Delay (NGD), demonstrated in simple electronic circuits, has been shown to temporally advance the detection of …
Simulation Of Temperature Distributions In Tissue Upon Laser Pulse Irradiation Including Water Mass Transfer, Deepthi Nagulapally
Simulation Of Temperature Distributions In Tissue Upon Laser Pulse Irradiation Including Water Mass Transfer, Deepthi Nagulapally
Electrical & Computer Engineering Theses & Dissertations
Lasers, due to their unique characteristics, have tremendous applications in the medical field. Generally all laser applications in hie-medicine involve the propagation of laser energy through tissue. Energy is deposited giving rise to many physical, hie-chemical, and mechanical effects. Among these are dynamical changes in the local temperature distributions within the tissue. Analysis of the temperature changes requires the creation of an appropriate optical transmission and heat flow model that incorporates user specified laser parameters. Here, a numerical simulation model was developed to study both steady state and time dependent temperature distributions due to pulsed laser radiation within user specified …
Intelligibility Of Electrolarynx Speech Using A Novel Actuator, Brian Madden, Mark Nolan, Ted Burke, James Condron, Eugene Coyle
Intelligibility Of Electrolarynx Speech Using A Novel Actuator, Brian Madden, Mark Nolan, Ted Burke, James Condron, Eugene Coyle
Conference Papers
During voiced speech, the larynx provides quasi-periodic acoustic excitation of the vocal tract. Following a laryngectomy, some people speak using an electrolarynx which replaces the excitatory function of the absent larynx. Drawbacks of conventional electrolarynx designs include the buzzing monotonic sound emitted, the need for a free hand to operate the device, and difficulty experienced by many laryngectomees in adapting to its use. Despite these shortcomings, it remains the preferred method of speech rehabilitation for a substantial minority of laryngectomees. In most electrolarynxes, mechanical vibrations are produced by a linear electromechanical actuator, the armature of which percusses against a metal …
Human Osteoblast Proliferation In Culture Following A Nanosecond Pulsed Electric Field (Nspef), Leonard Joseph Carinci Jr.
Human Osteoblast Proliferation In Culture Following A Nanosecond Pulsed Electric Field (Nspef), Leonard Joseph Carinci Jr.
Biological Sciences Theses & Dissertations
Osteoblasts are mononucleate bone forming cells responsible for the deposition of new bone. Application of mechanical stress on bone reveals its ability to produce and release electric potentials across the cell membrane called piezoelectricity. The electric potentials produced in response to mechanical stress may have a direct correlation on osseous cells and the signaling pathways that regulate proliferation. Nanosecond pulsed electric fields (nsPEFs) are high intensity, ultrashort pulses which have the ability to maintain the integrity of the cell membrane by avoiding traditional electroporation. We delivered 8 nsPEFs (0.5 Hz) of a 25 kV/cm or 35 kV/cm electric field strength …
Combining Molecular And Imaging Biomarkers To Enhance Maldi Biomarker Analysis, Ayyappa Chowdary Vadlamudi
Combining Molecular And Imaging Biomarkers To Enhance Maldi Biomarker Analysis, Ayyappa Chowdary Vadlamudi
Electrical & Computer Engineering Theses & Dissertations
This thesis presents a three-step method to predict prostate cancer (PCa) regions on biopsy tissue samples based on high confident, low resolution PCa regions marked by a pathologist. First, a prediction model is designed to predict PCa regions using matrix-assisted laser desorption mass spectrometry (MALDI-MS) tissue imaging data from one prostate tissue slice. Second, a texture analysis technique is applied to a high magnification optical image for the same purpose from an adjacent tissue slice. Finally, those two results are fused to obtain the PCa regions that will assist MALDI imaging biomarker analysis. Experiments show that the texture analysis based …
Theory Of ‘Selectivity’ Of Label-Free Nanobiosensors – A Geometro-Physical Perspective, Pradeep R. Nair, Muhammad A. Alam
Theory Of ‘Selectivity’ Of Label-Free Nanobiosensors – A Geometro-Physical Perspective, Pradeep R. Nair, Muhammad A. Alam
Birck and NCN Publications
Modern label-free biosensors are generally far more sensitive and require orders of magnitude less incubation time compared to their classical counterparts. However, a more important characteristic regarding the viability of this technology for applications in Genomics/Proteomics is defined by the ‘Selectivity’, i.e., the ability to concurrently and uniquely detect multiple target biomolecules in the presence of interfering species. Currently, there is no theory of Selectivity that allows optimization of competing factors and there are few experiments to probe this problem systematically. In this article, we use the elementary considerations of surface exclusion, diffusion limited transport, and void distribution function to …
Bioelectric Applications For Treatment Of Melanoma, Stephen J. Beebe, Karl H. Schoenbach, Richard Heller
Bioelectric Applications For Treatment Of Melanoma, Stephen J. Beebe, Karl H. Schoenbach, Richard Heller
Bioelectrics Publications
Two new cancer therapies apply bioelectric principles. These methods target tumor structures locally and function by applying millisecond electric fields to deliver plasmid DNA encoding cytokines using electrogene transfer (EGT) or by applying rapid rise-time nanosecond pulsed electric fields (nsPEFs). EGT has been used to locally deliver cytokines such as IL-12 to activate an immune response, resulting in bystander effects. NsPEFs locally induce apoptosis-like effects and affect vascular networks, both promoting tumor demise and restoration of normal vascular homeostasis. EGT with IL-12 is in melanoma clinical trials and nsPEFs are used in models with B16F10 melanoma in vitro and in …