Design Optimization Of An Above-Knee Prosthesis With Energy Regeneration, Taylor Barto, Holly Warner, Rick Rarick, Dan Simon Sep 2013

Design Optimization Of An Above-Knee Prosthesis With Energy Regeneration, Taylor Barto, Holly Warner, Rick Rarick, Dan Simon

Undergraduate Research Posters 2013

Above-knee amputees who use a prosthetic leg typically have to compensate for its shortcomings with unnatural hip motions. This compensation eventually leads to adverse health issues such as arthritis. We propose an active prosthesis to improve performance. The motor in our prosthetic knee allows the patient to move his hip normally, thus reducing the possibility of ancillary health issues. To improve the efficiency of the prosthesis, we use the braking phase of the prosthesis to regenerate energy. By storing energy in a supercapacitor during braking, the prosthesis lasts longer between each charge than it would without regenerative braking. We are …


Towards A More Robust Lower Neck Compressive Injury Tolerance - An Approach Combining Multiple Test Methodologies, Daniel Toomey, King H. Yang, N Yoganadan, F A. Pintar, C A. Van Ee Sep 2013

Towards A More Robust Lower Neck Compressive Injury Tolerance - An Approach Combining Multiple Test Methodologies, Daniel Toomey, King H. Yang, N Yoganadan, F A. Pintar, C A. Van Ee

Biomedical Engineering Faculty Research Publications

Objective.The compressive tolerance of the cervical spine has traditionally been reported in terms of axial force at failure. Previous studies suggest that axial compressive force at failure is particularly sensitive to the alignment of the cervical vertebra and the end conditions of the test methodology used. The present study was designed to develop a methodology to combine the data of previous experiments into a diverse dataset utilizing multiple test methods to allow for the evaluation of the robustness of current and proposed eccentricity based injury criteria.

Methods. Data was combined from two studies composed of dynamic experiments including whole …


Why Is Ca3 More Vulnerable Than Ca1 In Experimental Models Of Controlled Cortical Impact-Induced Brain Injury?, Haojie Mao, Benjamin S. Elkin, Vinay V. Genthikatti, Barclay Morrison Iii, King H. Yang Sep 2013

Why Is Ca3 More Vulnerable Than Ca1 In Experimental Models Of Controlled Cortical Impact-Induced Brain Injury?, Haojie Mao, Benjamin S. Elkin, Vinay V. Genthikatti, Barclay Morrison Iii, King H. Yang

Biomedical Engineering Faculty Research Publications

One interesting finding of controlled cortical impact (CCI) experiments is that the CA3 region of the hippocampus, which is positioned further from the impact than the CA1 region, is reported as being more injured. The current literature has suggested a positive correlation between brain tissue stretch and neuronal cell loss. However, it is counterintuitive to assume that CA3 is stretched more during CCI injury. Recent mechanical studies of the brain have reported on a level of spatial heterogeneity not previously appreciated—the finding that CA1 was significantly stiffer than all other regions tested and that CA3 was one of the most …


Finite Element Models Of The Knee & Hip Joints: Using Opensim To Predict Muscle Forces, Kevin S. Jones, Spencer D. Wangerin, Jeffrey D. Pyle, Stephen M. Klisch, Scott J. Hazelwood Aug 2013

Finite Element Models Of The Knee & Hip Joints: Using Opensim To Predict Muscle Forces, Kevin S. Jones, Spencer D. Wangerin, Jeffrey D. Pyle, Stephen M. Klisch, Scott J. Hazelwood

STAR Program Research Presentations

Quantitative data of stresses and strains in the cartilage of the knee and hip joints are required to design prostheses and can be used to give accurate advice to patients with cartilage damage as to which activities should be avoided. Instrumented hip implants can only give the overall resultant force in the joint, not the stresses and strains throughout the cartilage. Finite Element (FE) models of the Knee and Hip are being constructed in order to obtain the stresses and strains in articular (of the joint) cartilage. Muscle forces and joint contact forces are required as inputs to these FE …


The Effects Of Variation In Collagen D-Spacing On Compact Bone Viscoelasticity: A Finite Element Analysis, Miguel A. Mendoza Aug 2013

The Effects Of Variation In Collagen D-Spacing On Compact Bone Viscoelasticity: A Finite Element Analysis, Miguel A. Mendoza

Master's Theses

The D-spacing that is characteristic of collagen and its structural arrangement was previously thought to be a constant value. Much research is revealing that it is actually a distribution of values in biological tissues. Recent ovine experimentation has also shown that the D-spacing distribution is significantly altered following estrogen depletion. While ewes contain some major biological differences between their human counterparts, they are an economical and robust large animal model for postmenopausal osteoporosis. So, the exploration of the possible implications that D-spacing has on the mechanical properties of the whole bone utilizing animal models and computational methods is warranted. Six …


Design Of A Compliant Underactuated Robotic Finger With Coordinated Stiffness, Etienne Dessauw Aug 2013

Design Of A Compliant Underactuated Robotic Finger With Coordinated Stiffness, Etienne Dessauw

Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research

The concept of underactuation has been previously developed in the robotic field for grasping applications. For these anthropomorphic grippers, the minimization of the number of input signals, or in other words underactuation, is the most expected characteristic. This method has become very popular in recent decades. Indeed, by minimizing the number of input signals, it minimizes the complexity of the system’s control and at the same time avoids increased weight and cost. The inconvenience of such a technique is that the design of this type of system remains a difficult task if the behavior of the underactuated set of joints …


Finite Element Analysis And Validation Of Hip Joints With The Main Types Of Femoroacetabular Impingement, Kevin Lucas Mitchell Aug 2013

Finite Element Analysis And Validation Of Hip Joints With The Main Types Of Femoroacetabular Impingement, Kevin Lucas Mitchell

Master's Theses

Current research suggests that femoroacetabular impingement can be a cause of osteoarthritis. Femoroacetabular impingement is a condition that can affect both the femur and the pelvis of an individual. Femoroacetabular impingement can cause damage to the hip joint and its surrounding tissues. The articular cartilage and the labrum are both affected by this condition. A cam impingement is where a bony protrusion develops at the femoral head/neck junction. A pincer impingement is where a bony protrusion develops at the acetabular rim. Often, patients are seen with a combination of both impingements. The main goal of this study was to computationally …


Computational Biomechanical Modeling Of The Human Knee During Kneeling, Tariq R. Abo-Alhol Aug 2013

Computational Biomechanical Modeling Of The Human Knee During Kneeling, Tariq R. Abo-Alhol

Electronic Theses and Dissertations

Total knee replacement benefits patients who suffer from severe knee pain or joint stiffness and other joint related illnesses that limit everyday activities. There has been an increase in the number of procedures performed each year and a need to evaluate the performance of these implants during specialized activities such as kneeling. Most computational studies lack insight into inter-patient variability and the results do not apply to large population. This study developed: (1) three-dimensional explicit finite element (FE) models to investigate natural and implanted knee joint kinematics and bone strain and (2) a platform to enable population-based evaluation by combining …


Interleukin Expression After Injury And The Effects Of Interleukin-1 Receptor Antagonist, Connie S. Chamberlain, Ellen M. Leiferman, Kayt E. Frisch, Stacey L. Brickson, William L. Murphy, Geoffrey S. Baer, Ray Vanderby Aug 2013

Interleukin Expression After Injury And The Effects Of Interleukin-1 Receptor Antagonist, Connie S. Chamberlain, Ellen M. Leiferman, Kayt E. Frisch, Stacey L. Brickson, William L. Murphy, Geoffrey S. Baer, Ray Vanderby

Faculty Work Comprehensive List

Ligament healing follows a series of complex coordinated events involving various cell types, cytokines, as well as other factors, producing a mechanically inferior tissue more scar-like than native tissue. Macrophages provide an ongoing source of cytokines to modulate inflammatory cell adhesion and migration as well as fibroblast proliferation. Studying interleukins inherent to ligament healing during peak macrophage activation and angiogenesis may elucidate inflammatory mediators involved in subsequent scar formation. Herein, we used a rat healing model assayed after surgical transection of their medial collateral ligaments (MCLs). On days 3 and 7 post-injury, ligaments were collected and used for microarray analysis. …


Subtalar Joint Instability: Diagnosis And Conservative Treatment, Julie Choisne Jul 2013

Subtalar Joint Instability: Diagnosis And Conservative Treatment, Julie Choisne

Mechanical & Aerospace Engineering Theses & Dissertations

Subtalar instability may be caused by various ligamentous injuries. Combined instability at the ankle and subtalar joint is not adequately diagnosed. Further, isolated subtalar instability is usually misdiagnosed which may lead to long term damage to the joint. Developing a non-invasive and clinically practical tool to diagnose subtalar joint instability would be an important asset. The ability of an ankle brace, a common treatment for hindfoot instability, to promote stability for the subtalar joint was not well established. The purposes of this study were to 1) assess the kinematics of the subtalar, ankle, and hindfoot in the presence of isolated …


Design And Development Of A Stair Ascension Assistive Device For Transfemoral Amputees, Casey Michael Barbarino Jun 2013

Design And Development Of A Stair Ascension Assistive Device For Transfemoral Amputees, Casey Michael Barbarino

Master's Theses

Transfemoral amputees around the world experience increased difficulty in climbing stairs due to lack of muscle, balance, and other factors. The loss of a lower limb greatly diminishes the amount of natural force generation provided that is necessary to propel oneself up stairs. This study investigated possible solutions to the problem of stair ascension for transfemoral amputees by the means of designing and developing an externally attachable device to a prosthesis. The number of amputations from military service has greatly increased since 2008, which shows there is a clear need for assistive devices (Wenke, Krueger, & Ficke, 2012). With the …


Evaluation Of The Anterior Talofibular And Calcaneofibular Ligament In Relation To Supination Ankle Sprains, Peter Tran Jun 2013

Evaluation Of The Anterior Talofibular And Calcaneofibular Ligament In Relation To Supination Ankle Sprains, Peter Tran

Biomedical Engineering

Ankle injuries have always posed an issue to a number of athletes. Sports that involve running and jumping accumulate about 25% of injuries correlating to ankle sprains. In most ankle sprains the inversion (supination) of the ankle cause damage to lateral ligaments. The two most common lateral ligaments to experience damage are the anterior talofibular (ATFL) and calcaneofibular (CFL) ligaments. The methods of taping and ankle braces have allowed athletes to prevent recurring sprains from occurring. However, sprains can still occur even when one or both methods are applied. The purpose of each method is to restrict the range of …


Analysis Of Acetabular Cup Orientation Effects On Stress Shielding In Total Hip Replacements Using Finite Element Methods, Brogan Mcguire, Jennifer Gemkow, Brad Gausewitz, Alex Georges Jun 2013

Analysis Of Acetabular Cup Orientation Effects On Stress Shielding In Total Hip Replacements Using Finite Element Methods, Brogan Mcguire, Jennifer Gemkow, Brad Gausewitz, Alex Georges

Biomedical Engineering

Improper positioning of the acetabular cup has been shown to contribute to issues such as high wear rates and dislocations in total hip replacements. The differences in contact mechanics due to varying orientation of the acetabular cup may also significantly affect strain distribution in the femur. This study examined these effects of acetabular orientation changes and their contribution to stress shielding using finite element analysis. A solid model of a cementless total hip implant was obtained using 3D point scanning and implanted virtually into a femur solid model. The implanted femur model was imported into ABAQUS and loaded with a …


Modeling The Zimmer Fitmore And Ml Taper Implantation, Tyler Kazuo Franklin May 2013

Modeling The Zimmer Fitmore And Ml Taper Implantation, Tyler Kazuo Franklin

Master's Theses

With more young adults requiring total hip

arthroplasties the need for bone saving implants becomes

more important. The Zimmer Fitmore is a new bone saving

implant that utilizes an implantation technique that

reduces the damage to the muscle tissue allowing for

patients to have a short recovery time as well as a new

design that allows it to rest on the medial cortex. There

has been anecdotal evidence that this device leads to early

revision within six months of implantation due to failures

occurring in the medial cortex. The main goal of this

study was to computationally model the Zimmer …


A Microfluidic Pretreatment Isoelectric Focusing Dc-Field Assisted H-Filter For The Separation Of Charged Particles, Cameron Sean Carroll Mar 2013

A Microfluidic Pretreatment Isoelectric Focusing Dc-Field Assisted H-Filter For The Separation Of Charged Particles, Cameron Sean Carroll

Biomedical Engineering

Microfluidic devices are small portable diagnostic chips that allow for analysis of a biologic sample at relatively low cost. This makes them ideal for settings where a hospital is unavailable. The microfluidic pretreatment isoelectric focusing DC-field assisted H-filter is a device that allows for the separation of differently charged particles in a biologic sample. It does this by employing the concepts of diffusion, electrophoresis, and isoelectric focusing. This is perfect for isolation of a desired analyte or separation of waste from a sample in order to achieve better diagnostic results. The device was first modeled mathematically and visually using Comsol. …


The Effects Of Toning Shoes On The Postural Stability Of Women, Kevin Farley, Audrey Niverson, Renee Rogge Jan 2013

The Effects Of Toning Shoes On The Postural Stability Of Women, Kevin Farley, Audrey Niverson, Renee Rogge

Rose-Hulman Undergraduate Research Publications

Postural stability is the ability to maintain an upright posture and to keep the center of pressure (COP) within the limits of the body’s base of support. It is maintained through the dynamic integration of muscle activity and joint position. The foot, and therefore footwear, also plays a critical role in postural stability. The goal of this study is to determine the effects of toning shoes on the postural stability of women.


Distal Placement Of An End-To-Side Bypass Graft Anastomosis: A 3d Computational Study, John Di Cicco, Ayodeji Demuren Jan 2013

Distal Placement Of An End-To-Side Bypass Graft Anastomosis: A 3d Computational Study, John Di Cicco, Ayodeji Demuren

Mechanical & Aerospace Engineering Faculty Publications

A three-dimensional (3D) computational fluid dynamics study of shear rates around distal end-to-side anastomoses has been conducted. Three 51% and three 75% cross-sectional area-reduced 6 mm cylinders were modeled each with a bypass cylinder attached at a 30-degree angle at different placements distal to the constriction. Steady, incompressible, Newtonian blood flow was assumed, and the full Reynolds-averaged Navier-Stokes equations, turbulent kinetic energy, and specific dissipation rate equations were solved on a locally structured multiblock mesh with hexahedral elements. Consequently, distal placement of an end-to-side bypass graft anastomosis was found to have an influence on the shear rate magnitudes. For the …


The Effects Of Hydrostatic Pressure On Early Endothelial Tubulogenic Processes, Ryan M. Underwood Jan 2013

The Effects Of Hydrostatic Pressure On Early Endothelial Tubulogenic Processes, Ryan M. Underwood

Theses and Dissertations--Biomedical Engineering

The effects of mechanical forces on endothelial cell function and behavior are well documented, but have not been fully characterized. Specifically, fluid pressure has been shown to elicit physical and chemical responses known to be involved in the initiation and progression of endothelial cell-mediated vascularization. Central to the process of vascularization is the formation of tube-like structures. This process—tubulogenesis—is essential to both the physiological and pathological growth of tissues. Given the known effects of pressure on endothelial cells and its ubiquitous presence in the vasculature, we investigated pressure as a magnitude-dependent parameter for the regulation of endothelial tubulogenic activity. To …


Effect Of Rolling On Viscoelastic Fluids Using A Novel Testing Device, Aswini Mangadu Jan 2013

Effect Of Rolling On Viscoelastic Fluids Using A Novel Testing Device, Aswini Mangadu

Dissertations and Theses

The purpose of this research thesis project was to develop a mechanical testing device that could enable us to load articular cartilage with a rolling/sliding motion. This novel device was then used to observe the effect of a rolling motion on the fluid film thickness of different lubricants (motor oil, synovial fluid and Hyaluronic Acid (HA)) to varying loads (1kg, 2,kg, 3kg and 4kg) and speeds (10, 25, 48 and 91 mm/s) applied on the sample fluids for 10 cycles. We were able to examine the effect of different speeds within each load for each of the fluid that was …


Bone Properties By Nanoindentation In Mild And Severe Osteogenesis Imperfecta, Carolyne Albert, John Jameson, Jeffrey M. Toth, Peter Smith, Gerald F. Harris Jan 2013

Bone Properties By Nanoindentation In Mild And Severe Osteogenesis Imperfecta, Carolyne Albert, John Jameson, Jeffrey M. Toth, Peter Smith, Gerald F. Harris

Biomedical Engineering Faculty Research and Publications

Background

Osteogenesis imperfecta is a heterogeneous genetic disorder characterized by bone fragility. Previous research suggests that impaired collagen network and abnormal mineralization affect bone tissue properties, however, little data is yet available to describe bone material properties in individuals with this disorder. Bone material properties have not been characterized in individuals with the most common form of osteogenesis imperfecta, type I.

Methods

Bone tissue elastic modulus and hardness were measured by nanoindentation in eleven osteotomy specimens that were harvested from children with osteogenesis imperfecta during routine surgeries. These properties were compared between osteogenesis imperfecta types I (mild, n = …


Designing For Success: Developing Engineers Who Consider Universal Design Principles, Kimberly Edginton Bigelow Oct 2012

Designing For Success: Developing Engineers Who Consider Universal Design Principles, Kimberly Edginton Bigelow

Mechanical and Aerospace Engineering Faculty Publications

Engineers must design for a diverse group of potential users of their products; however, engineering curricula rarely include an emphasis on universal design principles. This research article details the effectiveness of a design project implemented in a first-year engineering course in an effort to raise awareness of the need for engineers to be more inclusive when designing. Students were asked to apply universal design principles to redesign an engineering laboratory to make it more usable to all, including individuals with disabilities who use the room. A representative from the university’s disability services staff, as well as individuals with first-hand experience …


The Biomechanical Role Of Scaffolds In Augmented Rotator Cuff Tendon Repairs, Amit Aurora, Jesse A. Mccarron, Antonie J. Van Den Bogert, Jorge E. Gatica, Joseph P. Iannotti, Kathleen A. Derwin Aug 2012

The Biomechanical Role Of Scaffolds In Augmented Rotator Cuff Tendon Repairs, Amit Aurora, Jesse A. Mccarron, Antonie J. Van Den Bogert, Jorge E. Gatica, Joseph P. Iannotti, Kathleen A. Derwin

Mechanical Engineering Faculty Publications

Background

Scaffolds continue to be developed and used for rotator cuff repair augmentation; however, the appropriate scaffold material properties and/or surgical application techniques for achieving optimal biomechanical performance remains unknown. The objectives of the study were to simulate a previously validated spring-network model for clinically relevant scenarios to predict: (1) the manner in which changes to components of the repair influence the biomechanical performance of the repair and (2) the percent load carried by the scaffold augmentation component.

Materials and methods

The models were parametrically varied to simulate clinically relevant scenarios, namely, changes in tendon quality, altered surgical technique(s), and …


Viscoelastic Anisotropic Finite Element Mixture Model Of Articular Cartilage Using Viscoelastic Collagen Fibers And Validation With Stress Relaxation Data, Matthew Alexander Griebel Jun 2012

Viscoelastic Anisotropic Finite Element Mixture Model Of Articular Cartilage Using Viscoelastic Collagen Fibers And Validation With Stress Relaxation Data, Matthew Alexander Griebel

Master's Theses

Experimental results show that collagen fibers exhibit stress relaxation under tension and a highly anisotropic distribution. To further develop the earlier model of Stender [1], the collagen constituent was updated to reflect its intrinsic viscoelasticity and anisotropic distribution, and integrated with an existing mixture model with glycosaminoglycans and ground substance matrix. A two-term Prony series expansion of the quasi-linear viscoelastic model was chosen to model the viscoelastic properties of the collagen fibers. Material parameters were determined by using the simplex method to minimize the sum of squared errors between model results and experimental stress relaxation data of tissue in tension. …


A Kinetic Study Of Anti-Vegf-A Polyclonal Antibodies And Anti-Vegf-A Ssdna Aptamers, Heather A. Hedeen Jun 2012

A Kinetic Study Of Anti-Vegf-A Polyclonal Antibodies And Anti-Vegf-A Ssdna Aptamers, Heather A. Hedeen

Master's Theses

A new detection reagent that could possibly augment or replace antibodies research and diagnosis methods are aptamers. Aptamers are ssDNA, RNA or polypeptide constructs that function like active antibodies. Antibodies and aptamers both specifically bind to selected target molecules, and as such they enable the detection or targeting of the presence or absence of a specific antigen.

In order to ensure that ssDNA aptamers perform similarly to antibodies, anti-VEGF-A polyclonal antibody and anti-VEGF-A ssDNA aptamer were evaluated against vascular endothelial growth factor A (VEGF-A) using Surface Plasmon Resonance (SPR). It was hypothesized that the anti-VEGF-A aptamer had the same, if …


Hydraulically Driven Mechanical Representation Of A Biological System, Andrea Argouarch, Michael Mceachern, Brandon Parham Jun 2012

Hydraulically Driven Mechanical Representation Of A Biological System, Andrea Argouarch, Michael Mceachern, Brandon Parham

Biomedical Engineering

No abstract provided.


Development And Application Of A Portable System To Reliably Measure Grip Forces Using Thin-Film Force Sensors, Shane Vincent Tornifoglio May 2012

Development And Application Of A Portable System To Reliably Measure Grip Forces Using Thin-Film Force Sensors, Shane Vincent Tornifoglio

Master's Theses

Accurate tracking of hand grip force is an important consideration needed for a robust understanding in the study of human biomechanics. One aspect where it proves useful is in hand-arm vibration, such as from gripping a power tool. Depending on how firmly the user is gripping the tool, they may change their exposure levels to the tool vibration, which can lead to potential disorders such as Hand-Arm Vibration Syndrome (HAVS).

A small, battery powered portable force unit has been developed to supply power to, and condition, the signals from eight thin-film force sensors. This gives a better understanding of the …


A Comprehensive Methodology For Assessing Biomechanical Risks Associated With Hand Tool Use: Applied To Laparoscopic Surgical Instruments, Drew R. Seils May 2012

A Comprehensive Methodology For Assessing Biomechanical Risks Associated With Hand Tool Use: Applied To Laparoscopic Surgical Instruments, Drew R. Seils

Master's Theses

Biomechanical risk factors are physical stressors that act on the neuromuscular structures of the human body and are present in all occupational settings. Repetition and intensity of tasks performed can magnify the effects of the biomechanical risks that a worker is exposed to.

After reviewing the current literature on ergonomics in laparoscopic surgery it was clear that a comprehensive approach to quantitatively reporting on the biomechanical risk factors associated with surgical hand tools had never been performed. Utilizing an opto-electronic motion capture system meant the exact surgeon posture was recorded during simulated surgical tasks. Electromyography was used to evaluate muscle …


Simulation Of Lower Limb Axial Arterial Length Change During Locomotion, Melissa D. Young, Matthew C. Streicher, Richard J. Beck, Antonie J. Van Den Bogert, Azita Tajaddini, Brian L. Davis May 2012

Simulation Of Lower Limb Axial Arterial Length Change During Locomotion, Melissa D. Young, Matthew C. Streicher, Richard J. Beck, Antonie J. Van Den Bogert, Azita Tajaddini, Brian L. Davis

Mechanical Engineering Faculty Publications

The effect of external forces on axial arterial wall mechanics has conventionally been regarded as secondary to hemodynamic influences. However, arteries are similar to muscles in terms of the manner in which they traverse joints, and their three-dimensional geometrical requirements for joint motion. This study considers axial arterial shortening and elongation due to motion of the lower extremity during gait, ascending stairs, and sitting-to-standing motion. Arterial length change was simulated by means of a graphics based anatomic and kinematic model of the lower extremity. This model estimated the axial shortening to be as much as 23% for the femoropopliteal arterial …


The Use Of A Pylon Mounted Transducer For Investigating The Gait Of Transtibial Amputees, Justin Robert Brink May 2012

The Use Of A Pylon Mounted Transducer For Investigating The Gait Of Transtibial Amputees, Justin Robert Brink

UNLV Theses, Dissertations, Professional Papers, and Capstones

Two areas of research interest in the design and use of lower limb prosthetic devices are how foot performance varies with design and how prosthesis alignment affects gait. The current study addressed both of these areas through the use of the JR3 triaxial transducer mounted at the base of the socket. The transducer is an innovative form of instrumentation that measures forces and moments at the end of the socket. Traditional measurement of gait uses a force plate buried in the floor of a gait laboratory. The study established that the transducer offers a viable means of instrumentation for amputee …


Mechanical Properties Of Bone Due To Sost Expression: A 3-Point Bending Assessment Of Murine Femurs, Kainoa John Peterson May 2012

Mechanical Properties Of Bone Due To Sost Expression: A 3-Point Bending Assessment Of Murine Femurs, Kainoa John Peterson

Master's Theses

Sclerostin, a protein coded for by the SOST gene, is an osteocyte-expressed negative regulator of bone formation. The absence of SOST in the genome may have an effect on bone formation both during skeletal maturation and full maturity. This study attempts to determine significant differences in the mechanical properties of bone that expresses SOST compared to bone that does not. One hundred femur samples from 6, 8, and 12 month old mice were obtained from Lawrence Livermore National Labs and loaded until failure using three-point bending. Results showed significant differences in treatment group effects for cross sectional area, yield force, …