Open Access. Powered by Scholars. Published by Universities.®
Biomedical Engineering and Bioengineering Commons™
Open Access. Powered by Scholars. Published by Universities.®
- Institution
-
- Old Dominion University (48)
- Dartmouth College (19)
- California Polytechnic State University, San Luis Obispo (16)
- University of Nebraska - Lincoln (13)
- Purdue University (10)
-
- Washington University in St. Louis (10)
- City University of New York (CUNY) (9)
- University of Kentucky (7)
- Harrisburg University of Science and Technology (6)
- University of Connecticut (6)
- Virginia Commonwealth University (6)
- Technological University Dublin (5)
- University of Mississippi (5)
- Ateneo de Manila University (4)
- Chapman University (4)
- Louisiana State University (4)
- The Texas Medical Center Library (4)
- University of Arkansas, Fayetteville (4)
- University of Central Florida (4)
- University of Nevada, Las Vegas (4)
- Duquesne University (3)
- Portland State University (3)
- The University of Akron (3)
- University of New Mexico (3)
- University of South Alabama (3)
- Brigham Young University (2)
- Clemson University (2)
- Institut de Recherche Robert-Sauvé en santé et en sécurité du travail (2)
- LSU Health New Orleans (2)
- Marquette University (2)
- Keyword
-
- Diagnosis (11)
- Humans (9)
- Biomedical engineering (8)
- Machine learning (8)
- Medical imaging (8)
-
- Biosensors (7)
- Deep learning (6)
- Female (6)
- Fluorescence (6)
- Drug delivery (5)
- Magnetic resonance imaging (5)
- Adult (4)
- Biomedical Engineering (4)
- Computer aided diagnosis (4)
- Glioma (4)
- Image processing (4)
- Instrumentation (4)
- Microfluidics (4)
- Nanoparticles (4)
- Sensitivity and specificity (4)
- Spectroscopy (4)
- Tissue engineering (4)
- Tissues (4)
- Acoustic Emission (3)
- Algorithms (3)
- Aneurysm (3)
- Artificial intelligence (3)
- Biomarkers (3)
- Biomaterials (3)
- Biomechanics (3)
- Publication Year
- Publication
-
- Electrical & Computer Engineering Faculty Publications (16)
- Dartmouth Scholarship (13)
- Center for Bioelectronics Publications (9)
- Master's Theses (9)
- McKelvey School of Engineering Graduate Student Theses & Dissertations (9)
-
- Theses and Dissertations (8)
- The Summer Undergraduate Research Fellowship (SURF) Symposium (7)
- Faculty Works (6)
- Honors Theses (6)
- Publications and Research (6)
- Biomedical Engineering (5)
- Electronic Theses and Dissertations (5)
- Bioelectrics Publications (4)
- Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research (4)
- Dissertations and Theses (Open Access) (4)
- Honors Scholar Theses (4)
- Honors Undergraduate Theses (4)
- LSU Doctoral Dissertations (4)
- Theses and Dissertations--Biomedical Engineering (4)
- Ateneo Laboratory for Intelligent Visual Environments (3)
- Biomedical Engineering Undergraduate Honors Theses (3)
- Computer Science Faculty Publications (3)
- Conference Papers (3)
- Dissertations and Theses (3)
- Mechanical & Aerospace Engineering Faculty Publications (3)
- Williams Honors College, Honors Research Projects (3)
- All Dissertations (2)
- Articles (2)
- Biomedical Engineering ETDs (2)
- Dartmouth College Master’s Theses (2)
- Publication Type
- File Type
Articles 211 - 240 of 257
Full-Text Articles in Biomedical Engineering and Bioengineering
Evaluation Of The Anterior Talofibular And Calcaneofibular Ligament In Relation To Supination Ankle Sprains, Peter Tran
Evaluation Of The Anterior Talofibular And Calcaneofibular Ligament In Relation To Supination Ankle Sprains, Peter Tran
Biomedical Engineering
Ankle injuries have always posed an issue to a number of athletes. Sports that involve running and jumping accumulate about 25% of injuries correlating to ankle sprains. In most ankle sprains the inversion (supination) of the ankle cause damage to lateral ligaments. The two most common lateral ligaments to experience damage are the anterior talofibular (ATFL) and calcaneofibular (CFL) ligaments. The methods of taping and ankle braces have allowed athletes to prevent recurring sprains from occurring. However, sprains can still occur even when one or both methods are applied. The purpose of each method is to restrict the range of …
Dynamic Dual-Tracer Mri-Guided Fluorescence Tomography To Quantify Receptor Density In Vivo, Scott C. Davis, Kimberley S. Samkoe, Kenneth M. Tichauer, Kristian J. Sexton, Jason R. Gunn, Sophie J. Deharvengt, Tayyaba Hasan, Brian W. Pogue
Dynamic Dual-Tracer Mri-Guided Fluorescence Tomography To Quantify Receptor Density In Vivo, Scott C. Davis, Kimberley S. Samkoe, Kenneth M. Tichauer, Kristian J. Sexton, Jason R. Gunn, Sophie J. Deharvengt, Tayyaba Hasan, Brian W. Pogue
Dartmouth Scholarship
The up-regulation of cell surface receptors has become a central focus in personalized cancer treatment; however, because of the complex nature of contrast agent pharmacokinetics in tumor tissue, methods to quantify receptor binding in vivo remain elusive. Here, we present a dual-tracer optical technique for noninvasive estimation of specific receptor binding in cancer. A multispectral MRI-coupled fluorescence molecular tomography system was used to image the uptake kinetics of two fluorescent tracers injected simultaneously, one tracer targeted to the receptor of interest and the other tracer a nontargeted reference. These dynamic tracer data were then fit to a dual-tracer compartmental model …
Biomedical Photoacoustic Imaging Using Gas-Coupled Laser Acoustic Detection, Jami Johnson
Biomedical Photoacoustic Imaging Using Gas-Coupled Laser Acoustic Detection, Jami Johnson
Student Research Initiative
Several detection methods have been explored for photoacoustic and ultrasound imaging of biological tissues. Piezoelectric transducers are commonly used, which require contact with the sample to be imaged and have limiting bandwidth characteristics. Interferometry detection exhibits improved bandwidth characteristics and resolution, yet generally require complicated optics and the incorporation of a contacting reflective medium. In this paper, we report the use of a noncontact photoacoustic imaging system that does not require the use of a reflective layer. A simple, robust technique known as gas-coupled laser acoustic detection is used, which has previously been applied to evaluation of composite materials. This …
Tracking Knee Joint Functional Axes Through Tikhonov Filtering And Plűcker Coordinates, Wangdo Kim, Yoon-Hyuk Kim, António P. Veloso, Sean S. Kohles
Tracking Knee Joint Functional Axes Through Tikhonov Filtering And Plűcker Coordinates, Wangdo Kim, Yoon-Hyuk Kim, António P. Veloso, Sean S. Kohles
Mechanical and Materials Engineering Faculty Publications and Presentations
Researchers have reported several compensation methods to estimate bone and joint position from a cluster of skin-mounted markers as influenced by Soft Tissue Artifacts (STA). Tikhonov Regularization Filtering (TRF) as a means to estimate Instantaneous Screw Axes (ISA) was introduced here as a means to reduce the displacement of a rigid body to its simplest geometric form. Recent studies have suggested that the ISA of the knee, i.e., Knee Functional Axes (KFA), might be closely connected to the estimation of constraint forces such as those due to medial and lateral connective tissues. The estimations of ISAs were known to be …
Scanning In Situ Spectroscopy Pplatform For Imaging Surgical Breast Tissue Specimens, Venkataramanan Krishnaswamy, Ashley M. Laughney, Wendy A. Wells, Keith D. Paulsen, Brian W. Pogue
Scanning In Situ Spectroscopy Pplatform For Imaging Surgical Breast Tissue Specimens, Venkataramanan Krishnaswamy, Ashley M. Laughney, Wendy A. Wells, Keith D. Paulsen, Brian W. Pogue
Dartmouth Scholarship
A non-contact localized spectroscopic imaging platform has been developed and optimized to scan 1 x 1 cm² square regions of surgically resected breast tissue specimens with ~150-micron resolution. A color corrected, image-space telecentric scanning design maintained a consistent sampling geometry and uniform spot size across the entire imaging field. Theoretical modeling in ZEMAX allowed estimation of the spot size, which is equal at both the center and extreme positions of the field with ~5% variation across the designed waveband, indicating excellent color correction. The spot sizes at the center and an extreme field position were also measured experimentally using the …
Automated Point-Of-Care Image Processing Methodology For The Diagnosis Of Malaria, Michael B. Jorgensen
Automated Point-Of-Care Image Processing Methodology For The Diagnosis Of Malaria, Michael B. Jorgensen
Master's Theses
Malaria has profoundly influenced human history for over four thousand years and despite numerous attempts at eradication, the prevention, diagnosis, and treatment of malaria have been largely ineffective. More than five hundred million people are affected by malaria every year resulting in over one million deaths. Drug resistance development by the parasite has diminished the effectiveness of numerous treatment options due, in part, to overtreatment of negative patients based on insufficient clinical algorithms and diagnostic methods. The goal of this research was to develop an image analysis algorithm to diagnose malaria with a high degree of sensitivity and specificity in …
Micromechanical Analysis Of Nanoparticle-Reinforced Dental Composites, Yi Hua, Linxia Gu, Hidehiko Watanabe
Micromechanical Analysis Of Nanoparticle-Reinforced Dental Composites, Yi Hua, Linxia Gu, Hidehiko Watanabe
Department of Mechanical and Materials Engineering: Faculty Publications
The mechanical behavior of TiO2 nanoparticle-reinforced resin-based dental composites was characterized in this work using a three-dimensional nanoscale representative volume element. The impacts of nanoparticle volume fraction, aspect ratio, stiffness, and interphase zone between the resin matrix and nanoparticle on the bulk properties of the composite were characterized. Results clearly demonstrated the mechanical advantage of nanocomposites in comparison to microfiber-reinforced composites. The bulk response of the nanocomposite could be further enhanced with the increased nanoparticle volume fraction, or aspect ratio, while the influence of nanoparticle stiffness was minimal. The effective Young’s modulus and yield strength of the composite was …
Noninvasive Near-Infrared Diffuse Optical Monitoring Of Cerebral Hemodynamics And Autoregulation, Ran Cheng
Noninvasive Near-Infrared Diffuse Optical Monitoring Of Cerebral Hemodynamics And Autoregulation, Ran Cheng
Theses and Dissertations--Biomedical Engineering
Many cerebral diseases are associated with abnormal cerebral hemodynamics and impaired cerebral autoregulation (CA). CA is a mechanism to maintain cerebral blood flow (CBF) stable when mean arterial pressure (MAP) fluctuates. Evaluating these abnormalities requires direct measurements of cerebral hemodynamics and MAP. Several near-infrared diffuse optical instruments have been developed in our laboratory for hemodynamic measurements including near-infrared spectroscopy (NIRS), diffuse correlation spectroscopy (DCS), hybrid NIRS/DCS, and dual-wavelength DCS flow-oximeter. We utilized these noninvasive technologies to quantify CBF and cerebral oxygenation in different populations under different physiological conditions/manipulations. A commercial finger plethysmograph was used to continuously monitor MAP. For investigating …
A Dna Computer For Glioblastoma Multiforme Diagnosis And Drug Delivery, Sumaiya F. Hashmi
A Dna Computer For Glioblastoma Multiforme Diagnosis And Drug Delivery, Sumaiya F. Hashmi
CMC Senior Theses
Glioblastoma multiforme (GBM) is a debilitating malignant brain tumor with expected patient survival of less than a year and limited responsiveness to most treatments, often requiring biopsy for diagnosis and invasive surgery for treatment. We propose a DNA computer system, consisting of input, computation, and output components, for diagnosis and treatment. The input component will detect the presence of three GBM biomarkers: vascular endothelial growth factor (VEGF), caveolin-1α (CAV), and B2 receptors. The computation component will include indicator segments for each of these genes, and ensure that output is only released if all the biomarkers are present. The output component …
Reviewing The American University Law Review On Extraterritoriality: A Critical Response To Viki Economides, Note, Tianrui Group Co. V. Itc: The Dubious Status Of Extraterritoriality And The Domestic Industry Requirement Requirement Of Section 337(Link), Jonathan Stroud
Scholarly Articles in Law Reviews & Journals
Recently, the Federal Circuit upheld the Commission’s decision to exclude goods based on a trade secret violation that largely happened abroad. The American University Law Review critiqued that decision on two grounds: First, that a presumption against extraterritorial application of U.S. law applied; and second, that licensing alone could not establish a domestic industry. The American University Law Review's critique remains incomplete, however, as the Federal Circuit correctly decided the case for at least two reasons. first, the Federal Circuit correctly applied the “extraterritorial presumption” canon of construction; and second, the recent Federal Circuit decision in InterDigital Communications LLC v. …
A Digital X-Ray Tomosynthesis Coupled Near Infrared Spectral Tomography System For Dual-Modality Breast Imaging, Venkataramanan Krishnaswamy, Kelly E. Michaelsen, Brian W. Pogue, Steven P. Poplack, Ian Shaw, Ken Defrietas, Ken Brooks, Keith D. Paulsen
A Digital X-Ray Tomosynthesis Coupled Near Infrared Spectral Tomography System For Dual-Modality Breast Imaging, Venkataramanan Krishnaswamy, Kelly E. Michaelsen, Brian W. Pogue, Steven P. Poplack, Ian Shaw, Ken Defrietas, Ken Brooks, Keith D. Paulsen
Dartmouth Scholarship
A Near Infrared Spectral Tomography (NIRST) system has been developed and integrated into a commercial Digital Breast Tomosynthesis (DBT) scanner to allow structural and functional imaging of breast in vivo. The NIRST instrument uses an 8-wavelength continuous wave (CW) laser-based scanning source assembly and a 75-element silicon photodiode solid-state detector panel to produce dense spectral and spatial projection data from which spectrally constrained 3D tomographic images of tissue chromophores are produced. Integration of the optical imaging system into the DBT scanner allows direct co-registration of the optical and DBT images, while also facilitating the synergistic use of x-ray contrast as …
Quantitative Cherenkov Emission Spectroscopy For Tissue Oxygenation Assessment, Johan Axelsson, Adam K. Glaser, David J. Gladstone, Brian W. Pogue
Quantitative Cherenkov Emission Spectroscopy For Tissue Oxygenation Assessment, Johan Axelsson, Adam K. Glaser, David J. Gladstone, Brian W. Pogue
Dartmouth Scholarship
Measurements of Cherenkov emission in tissue during radiation therapy are shown to enable estimation of hemoglobin oxygen saturation non-invasively, through spectral fitting of the spontaneous emissions from the treated tissue. Tissue oxygenation plays a critical role in the efficacy of radiation therapy to kill tumor tissue. Yet in-vivo measurement of this has remained elusive in routine use because of the complexity of oxygen measurement techniques. There is a spectrally broad emission of Cherenkov light that is induced during the time of irradiation, and as this travels through tissue from the point of the radiation deposition, the tissue absorption and scatter …
Assessing The Therapeutic Effect Of 630 Nm Light-Emitting Diodes Irradiation On The Recovery Of Exercise-Induced Hand Muscle Fatigue With Surface Electromyogram, Dandan Yang, Xiaoying Wu, Wensheng Hou, Xiaolin Zheng, Jun Zheng, Yingtao Jiang
Assessing The Therapeutic Effect Of 630 Nm Light-Emitting Diodes Irradiation On The Recovery Of Exercise-Induced Hand Muscle Fatigue With Surface Electromyogram, Dandan Yang, Xiaoying Wu, Wensheng Hou, Xiaolin Zheng, Jun Zheng, Yingtao Jiang
Electrical & Computer Engineering Faculty Research
This paper aims to investigate the effect of light emitting diode therapy (LEDT) on exercise-induced hand muscle fatigue by measuring the surface electromyography (sEMG) of flexor digitorum superficialis. Ten healthy volunteers were randomly placed in the equal sized LEDT group and control group. All subjects performed a sustained fatiguing isometric contraction with the combination of four fingertips except thumb at 30% of maximal voluntary contraction (MVC) until exhaustion. The active LEDT or an identical passive rest therapy was then applied to flexor digitorum superficialis. Each subject was required to perform a re-fatigue task immediately after therapy which was the same …
Targeted Multistage Delivery Of Nanoparticles To The Bone Marrow, Aman Mann
Targeted Multistage Delivery Of Nanoparticles To The Bone Marrow, Aman Mann
Dissertations and Theses (Open Access)
Bone marrow is a target organ site involved in multiple diseases including myeloproliferative disorders and hematologic malignancies and metastases from breast and prostate. Most of these diseases are characterized with poor quality of life, and the treatment options are only palliative due to lack of delivery mechanisms for systemically injected drugs which results in dose limitation to protect the healthy hematopoietic cells. Therefore, there is a critical need to develop effective therapeutic strategies that allow for selective delivery of therapeutic payload to the bone marrow. Nanotechnology-based drug delivery systems provide the opportunity to deliver drugs to the target tissue while …
In-Vivo Ct Dosimetry During Virtual Colonoscopy, Jonathon W. Mueller
In-Vivo Ct Dosimetry During Virtual Colonoscopy, Jonathon W. Mueller
Dissertations and Theses (Open Access)
Virtual colonoscopy (VC) is a minimally invasive means for identifying colorectal polyps and colorectal lesions by insufflating a patient’s bowel, applying contrast agent via rectal catheter, and performing multi-detector computed tomography (MDCT) scans. The technique is recommended for colonic health screening by the American Cancer Society but not funded by the Centers for Medicare and Medicaid Services (CMS) partially because of potential risks from radiation exposure. To date, no in‐vivo organ dose measurements have been performed for MDCT scans; thus, the accuracy of any current dose estimates is currently unknown.
In this study, two TLDs were affixed to the inner …
Cyberknife Radiation Modeling: Effects Of Relaxed Translational And Rotational Constraints On Healthy Tissue Irradiation, Sudha Bhavaroop Potineni
Cyberknife Radiation Modeling: Effects Of Relaxed Translational And Rotational Constraints On Healthy Tissue Irradiation, Sudha Bhavaroop Potineni
Electrical & Computer Engineering Theses & Dissertations
The Cyberknife system is a robotic radio surgery instrument that is used to treat cancers in different parts of the human body. Because of its accuracy and precision, it has become one of the best radio surgery systems in the world. However, even with Cyberknife the treatment time for one session takes from 30 minutes up to 120 minutes depending on the size, shape, and position of the tumor in the human body. In this research, a solution is presented to aid in reducing this long treatment time. An algorithm is developed which simulates the amount of the healthy tissue …
Determining A Method For Rendering Low Cost Cdse(Zns) Core(Shell) Quantum Dots Aqueous Soluble Via Amphiphilic Polymer Wrapping, Patrick Mcbride
Determining A Method For Rendering Low Cost Cdse(Zns) Core(Shell) Quantum Dots Aqueous Soluble Via Amphiphilic Polymer Wrapping, Patrick Mcbride
Materials Engineering
Herein is described the procedure of two amphiphilic polymer wrapping techniques that may be employed for obtaining aqueous soluble quantum dots (QDs) for use in biological fluorescent imaging applications. The advent of QDs has led to new nanoscale fluorescent materials that exhibit unparalleled quantum yields (QYs), high resistance to photobleaching, tunable emissions, and
absorption over a large optical range. However, the QD synthesis employed here at Cal Poly to obtain bright, photostable CdSe(ZnS) core(shell) QDs involves the use of organic solvents and surfactants, leading to hydrophobic QDs. Since all of biology relies on aqueous solubility, this hydrophobicity creates a major …
The Use Of Motion Analysis Technology As An Alternative Means Of Assessing Spinal Deformity In Patients With Adolescent Idiopathic Scoliosis, Matthew J. Solomito
The Use Of Motion Analysis Technology As An Alternative Means Of Assessing Spinal Deformity In Patients With Adolescent Idiopathic Scoliosis, Matthew J. Solomito
Master's Theses
Adolescent Idiopathic Scoliosis (AIS) is a three dimensional deformity of the spine that causes abnormal curvatures in the coronal and sagittal planes and abnormal vertebral rotations. The gold standard for diagnosing and tracking the progression of the deformity is through the use of repeated radiography and a patient can receive upwards of fifteen radiographic series over the course of treatment, which exposes this population to an increased risk of radiation-dependent complications.
This thesis presents the necessary calculations and the marker set required to make the motion capture technology a viable alternative to radiographs, in an effort to reduce the patient’s …
Laser Etched Pmma Microfluidic Chip Design And Manufacture With Applications In Capillary Zone Electrophoresis, Evan Allen Barbre
Laser Etched Pmma Microfluidic Chip Design And Manufacture With Applications In Capillary Zone Electrophoresis, Evan Allen Barbre
Master's Theses
This thesis encompasses a feasibility study of using low-cost materials to manufacture microfluidic chips that can perform the same functions as chips manufactured using traditional methods within an acceptable range of efficiency of chips created with more exotic methods and materials. The major parts of the project are the selection and characterization of the fabrication methods for creating the channels for fluid flow, the methods for sealing the channels to create a usable chip and the electrophoretic separations of carboxylated microspheres of different potentials. In this work we seek to answer the question if laser-etched PMMA microfluidic chips are comparable …
Bcc Skin Cancer Diagnosis Based On Texture Analysis Techniques, Shao-Hui Chuang, Xiaoyan Sun, Wen-Yu Chang, Gwo-Shing Chen, Adam Huang, Jiang Li, Frederic D. Mckenzie
Bcc Skin Cancer Diagnosis Based On Texture Analysis Techniques, Shao-Hui Chuang, Xiaoyan Sun, Wen-Yu Chang, Gwo-Shing Chen, Adam Huang, Jiang Li, Frederic D. Mckenzie
Electrical & Computer Engineering Faculty Publications
In this paper, we present a texture analysis based method for diagnosing the Basal Cell Carcinoma (BCC) skin cancer using optical images taken from the suspicious skin regions. We first extracted the Run Length Matrix and Haralick texture features from the images and used a feature selection algorithm to identify the most effective feature set for the diagnosis. We then utilized a Multi-Layer Perceptron (MLP) classifier to classify the images to BCC or normal cases. Experiments showed that detecting BCC cancer based on optical images is feasible. The best sensitivity and specificity we achieved on our data set were 94% …
Prediction Of Brain Tumor Progression Using Multiple Histogram Matched Mri Scans, Debrup Banerjee, Loc Tran, Jiang Li, Yuzhong Shen, Frederic Mckenzie, Jihong Wang, Ronald M. Summers (Ed.), Bram Van Ginneken (Ed.)
Prediction Of Brain Tumor Progression Using Multiple Histogram Matched Mri Scans, Debrup Banerjee, Loc Tran, Jiang Li, Yuzhong Shen, Frederic Mckenzie, Jihong Wang, Ronald M. Summers (Ed.), Bram Van Ginneken (Ed.)
Electrical & Computer Engineering Faculty Publications
In a recent study [1], we investigated the feasibility of predicting brain tumor progression based on multiple MRI series and we tested our methods on seven patients' MRI images scanned at three consecutive visits A, B and C. Experimental results showed that it is feasible to predict tumor progression from visit A to visit C using a model trained by the information from visit A to visit B. However, the trained model failed when we tried to predict tumor progression from visit B to visit C, though it is clinically more important. Upon a closer look at the MRI scans …
A Monocular Marker-Free Gait Measurement System, Jane Courtney, Annraoi M. De Paor
A Monocular Marker-Free Gait Measurement System, Jane Courtney, Annraoi M. De Paor
Articles
This paper presents a new, user-friendly, portable motion capture and gait analysis system for capturing and analyzing human gait, designed as a telemedicine tool to monitor remotely the progress of patients through treatment. The system requires minimal user input and simple single-camera filming (which can be acquired from a basic webcam) making it very accessible to nontechnical, nonclinical personnel. This system can allow gait studies to acquire a much larger data set and allow trained gait analysts to focus their skills on the interpretation phase of gait analysis. The design uses a novel motion capture method derived from spatiotemporal segmentation …
Bioelectric Applications For Treatment Of Melanoma, Stephen J. Beebe, Karl H. Schoenbach, Richard Heller
Bioelectric Applications For Treatment Of Melanoma, Stephen J. Beebe, Karl H. Schoenbach, Richard Heller
Bioelectrics Publications
Two new cancer therapies apply bioelectric principles. These methods target tumor structures locally and function by applying millisecond electric fields to deliver plasmid DNA encoding cytokines using electrogene transfer (EGT) or by applying rapid rise-time nanosecond pulsed electric fields (nsPEFs). EGT has been used to locally deliver cytokines such as IL-12 to activate an immune response, resulting in bystander effects. NsPEFs locally induce apoptosis-like effects and affect vascular networks, both promoting tumor demise and restoration of normal vascular homeostasis. EGT with IL-12 is in melanoma clinical trials and nsPEFs are used in models with B16F10 melanoma in vitro and in …
Automatic Exposure Control And Estimation Of Effective System Noise In Diffuse Fluorescence Tomography, Dax L. Kepshire, Hamid Dehghani, Frederic Leblond, Brian W. Pogue
Automatic Exposure Control And Estimation Of Effective System Noise In Diffuse Fluorescence Tomography, Dax L. Kepshire, Hamid Dehghani, Frederic Leblond, Brian W. Pogue
Dartmouth Scholarship
A diffuse fluorescence tomography system, based upon time-correlated single photon counting, is presented with an automated algorithm to allow dynamic range variation through exposure control. This automated exposure control allows the upper and lower detection levels of fluorophore to be extended by an order of magnitude beyond the previously published performance and benefits in a slight decrease in system effective noise. The effective noise level is used as a metric to characterize the system performance, integrating both model-mismatch and calibration bias errors into a single parameter. This effective error is near 7% of the reconstructed fluorescent yield value, when imaging …
Statistical Hypothesis Testing For Postreconstructed And Postregistered Medical Images, Eugene Demidenko
Statistical Hypothesis Testing For Postreconstructed And Postregistered Medical Images, Eugene Demidenko
Dartmouth Scholarship
Postreconstructed and postregistered medical images are typically treated as the raw data, implicitly assuming that those operations are error free. We question this assumption and explore how the precision of reconstruction and affine registration can be assessed by the image covariance matrix and confidence interval, called the confidence eigenimage, using a statistical model-based approach. Various hypotheses may be tested after image reconstruction and registration using classical statistical hypothesis testing vehicles: Is there a statistically significant difference between images? Does the intensity at a specific location or area of interest belong to the “normal” range? Is there a tumor? Does the …
Investigation Of Magnetic Resonance Imaging And Spectroscopy For The Detection Of Breast Cancer, Robert Thomas Etnire
Investigation Of Magnetic Resonance Imaging And Spectroscopy For The Detection Of Breast Cancer, Robert Thomas Etnire
UNLV Theses, Dissertations, Professional Papers, and Capstones
Magnetic resonance imaging (MRI) of the breast offers an alternative to screening mammography which may benefit those women at high risk for breast cancer, women under the age of 40, and those with dense breast tissue. One concern with MRI is the number of high false positives. Coupling MRI with magnetic resonance spectroscopy(MRS) may lower the number of false positives, and thus improve the diagnostic capabilities of MRI for the clinician. MRS for breast imaging focuses on the total choline containing compounds in the spectra in the suspected breast lesion to analyze areas of concern. The results of the study …
Parameter Optimization For Image Denoising Based On Block Matching And 3d Collaborative Filtering, Ramu Pedada, Emin Kugu, Jiang Li, Zhanfeng Yue, Yuzhong Shen, Josien P.W. Pluim (Ed.), Benoit M. Dawant (Ed.)
Parameter Optimization For Image Denoising Based On Block Matching And 3d Collaborative Filtering, Ramu Pedada, Emin Kugu, Jiang Li, Zhanfeng Yue, Yuzhong Shen, Josien P.W. Pluim (Ed.), Benoit M. Dawant (Ed.)
Electrical & Computer Engineering Faculty Publications
Clinical MRI images are generally corrupted by random noise during acquisition with blurred subtle structure features. Many denoising methods have been proposed to remove noise from corrupted images at the expense of distorted structure features. Therefore, there is always compromise between removing noise and preserving structure information for denoising methods. For a specific denoising method, it is crucial to tune it so that the best tradeoff can be obtained. In this paper, we define several cost functions to assess the quality of noise removal and that of structure information preserved in the denoised image. Strength Pareto Evolutionary Algorithm 2 (SPEA2) …
Automatic Diagnosis For Prostate Cancer Using Run-Length Matrix Method, Xiaoyan Sun, Shao-Hui Chuang, Jiang Li, Frederic Mckenzie, Nico Karssemeijer (Ed.), Maryellen L. Giger (Ed.)
Automatic Diagnosis For Prostate Cancer Using Run-Length Matrix Method, Xiaoyan Sun, Shao-Hui Chuang, Jiang Li, Frederic Mckenzie, Nico Karssemeijer (Ed.), Maryellen L. Giger (Ed.)
Electrical & Computer Engineering Faculty Publications
Prostate cancer is the most common type of cancer and the second leading cause of cancer death among men in US1. Quantitative assessment of prostate histology provides potential automatic classification of prostate lesions and prediction of response to therapy. Traditionally, prostate cancer diagnosis is made by the analysis of prostate-specific antigen (PSA) levels and histopathological images of biopsy samples under microscopes. In this application, we utilize a texture analysis method based on the run-length matrix for identifying tissue abnormalities in prostate histology. A tissue sample was collected from a radical prostatectomy, H&E fixed, and assessed by a pathologist …
Methodology Development For Three-Dimensional Mr-Guided Near Infrared Spectroscopy Of Breast Tumors, Colin M. Carpenter, Subhadra Srinivasan, Brian W. Pogue, Keith D. Paulsen
Methodology Development For Three-Dimensional Mr-Guided Near Infrared Spectroscopy Of Breast Tumors, Colin M. Carpenter, Subhadra Srinivasan, Brian W. Pogue, Keith D. Paulsen
Dartmouth Scholarship
Combined Magnetic Resonance (MR) and Near Infrared Spectroscopy (NIRS) has been proposed as a unique method to quantify hemodynamics, water content, and cellular size and packing density of breast tumors, as these tissue constituents can be quantified with increased resolution and overlaid on the structural features identified by the MR. However, the choices in how to reconstruct and visualize this information can have a dramatic impact on the feasibility of implementing this modality in the clinic. This is especially true in 3 dimensions, as there is often limited optical sampling of the breast tissue, and methods need to accurately reflect …
Medical Image Modeling And Processing, Ramu Pedada
Medical Image Modeling And Processing, Ramu Pedada
Electrical & Computer Engineering Theses & Dissertations
During the last few decades of the twentieth century, medical imaging has been playing a prominent role in many fields of biomedical research and clinical practice. Image modalities such as x-rays, computed tomography (CT), and magnetic resonance images (MRI) have all been valuable additions to the radiologist's arsenal of imaging tools. Medical images assure quality diagnosis and patient safety by gathering valuable information without invading the human body. Apart from clinical diagnosis, medical images are used as tools for education where they are used for training individuals before operating on a patient. Many medical educators tum to simulation based training …