Full-Text Articles in Engineering

Test 2134: John Deere 9570rt, Nebraska Tractor Test Lab Jan 2015

Test 2134: John Deere 9570rt, Nebraska Tractor Test Lab

Nebraska Tractor Tests

ABOUT THE TEST REPORT AND USE OF THE DATA The test data contained in this report are a tabulation of the results of a series of tests. Due to the restricted format of these pages, only a limited amount of data and not all of the tractor specifications are included. The full OECD report contains usually about 30 pages of data and specifications. The test data were obtained for each tractor under similar conditions and therefore, provide a means of comparison of performance based on a limited set of reported data. EXPLANATION OF THE TEST PROCEDURES Purpose The purpose of …


Test 2113: John Deere 7310r, Nebraska Tractor Test Lab Jan 2015

Test 2113: John Deere 7310r, Nebraska Tractor Test Lab

Nebraska Tractor Tests

ABOUT THE TEST REPORT AND USE OF THE DATA The test data contained in this report are a tabulation of the results of a series of tests. Due to the restricted format of these pages, only a limited amount of data and not all of the tractor specifications are included. The full OECD report contains usually about 30 pages of data and specifications. The test data were obtained for each tractor under similar conditions and therefore, provide a means of comparison of performance based on a limited set of reported data. EXPLANATION OF THE TEST PROCEDURES Purpose The purpose of …


Test 2136: John Deere 6175r Autoquad-Plus, Nebraska Tractor Test Lab Jan 2015

Test 2136: John Deere 6175r Autoquad-Plus, Nebraska Tractor Test Lab

Nebraska Tractor Tests

ABOUT THE TEST REPORT AND USE OF THE DATA The test data contained in this report are a tabulation of the results of a series of tests. Due to the restricted format of these pages, only a limited amount of data and not all of the tractor specifications are included. The full OECD report contains usually about 30 pages of data and specifications. The test data were obtained for each tractor under similar conditions and therefore, provide a means of comparison of performance based on a limited set of reported data. EXPLANATION OF THE TEST PROCEDURES Purpose The purpose of …


Test 2110: John Deere 9470rt, Nebraska Tractor Test Lab Jan 2015

Test 2110: John Deere 9470rt, Nebraska Tractor Test Lab

Nebraska Tractor Tests

ABOUT THE TEST REPORT AND USE OF THE DATA The test data contained in this report are a tabulation of the results of a series of tests. Due to the restricted format of these pages, only a limited amount of data and not all of the tractor specifications are included. The full OECD report contains usually about 30 pages of data and specifications. The test data were obtained for each tractor under similar conditions and therefore, provide a means of comparison of performance based on a limited set of reported data. EXPLANATION OF THE TEST PROCEDURES Purpose The purpose of …


Test 2128: Cabela's Lm75, Nebraska Tractor Test Lab Jan 2015

Test 2128: Cabela's Lm75, Nebraska Tractor Test Lab

Nebraska Tractor Tests

ABOUT THE TEST REPORT AND USE OF THE DATA The test data contained in this report are a tabulation of the results of a series of tests. Due to the restricted format of these pages, only a limited amount of data and not all of the tractor specifications are included. The full OECD report contains usually about 30 pages of data and specifications. The test data were obtained for each tractor under similar conditions and therefore, provide a means of comparison of performance based on a limited set of reported data. EXPLANATION OF THE TEST PROCEDURES Purpose The purpose of …


Test 2126: Case Ih Magnum 380, Nebraska Tractor Test Lab Jan 2015

Test 2126: Case Ih Magnum 380, Nebraska Tractor Test Lab

Nebraska Tractor Tests

ABOUT THE TEST REPORT AND USE OF THE DATA The test data contained in this report are a tabulation of the results of a series of tests. Due to the restricted format of these pages, only a limited amount of data and not all of the tractor specifications are included. The full OECD report contains usually about 30 pages of data and specifications. The test data were obtained for each tractor under similar conditions and therefore, provide a means of comparison of performance based on a limited set of reported data. EXPLANATION OF THE TEST PROCEDURES Purpose The purpose of …


Test 2125a: Case Ih Magnum 340, Nebraska Tractor Test Lab Jan 2015

Test 2125a: Case Ih Magnum 340, Nebraska Tractor Test Lab

Nebraska Tractor Tests

ABOUT THE TEST REPORT AND USE OF THE DATA The test data contained in this report are a tabulation of the results of a series of tests. Due to the restricted format of these pages, only a limited amount of data and not all of the tractor specifications are included. The full OECD report contains usually about 30 pages of data and specifications. The test data were obtained for each tractor under similar conditions and therefore, provide a means of comparison of performance based on a limited set of reported data. EXPLANATION OF THE TEST PROCEDURES Purpose The purpose of …


Test 2135: John Deere 9620r, Nebraska Tractor Test Lab Jan 2015

Test 2135: John Deere 9620r, Nebraska Tractor Test Lab

Nebraska Tractor Tests

ABOUT THE TEST REPORT AND USE OF THE DATA The test data contained in this report are a tabulation of the results of a series of tests. Due to the restricted format of these pages, only a limited amount of data and not all of the tractor specifications are included. The full OECD report contains usually about 30 pages of data and specifications. The test data were obtained for each tractor under similar conditions and therefore, provide a means of comparison of performance based on a limited set of reported data. EXPLANATION OF THE TEST PROCEDURES Purpose The purpose of …


Test 2133: John Deere 9570r, Nebraska Tractor Test Lab Jan 2015

Test 2133: John Deere 9570r, Nebraska Tractor Test Lab

Nebraska Tractor Tests

ABOUT THE TEST REPORT AND USE OF THE DATA The test data contained in this report are a tabulation of the results of a series of tests. Due to the restricted format of these pages, only a limited amount of data and not all of the tractor specifications are included. The full OECD report contains usually about 30 pages of data and specifications. The test data were obtained for each tractor under similar conditions and therefore, provide a means of comparison of performance based on a limited set of reported data. EXPLANATION OF THE TEST PROCEDURES Purpose The purpose of …


Test 2123: Case Ih Magnum 280, Nebraska Tractor Test Lab Jan 2015

Test 2123: Case Ih Magnum 280, Nebraska Tractor Test Lab

Nebraska Tractor Tests

ABOUT THE TEST REPORT AND USE OF THE DATA The test data contained in this report are a tabulation of the results of a series of tests. Due to the restricted format of these pages, only a limited amount of data and not all of the tractor specifications are included. The full OECD report contains usually about 30 pages of data and specifications. The test data were obtained for each tractor under similar conditions and therefore, provide a means of comparison of performance based on a limited set of reported data. EXPLANATION OF THE TEST PROCEDURES Purpose The purpose of …


Test 2123a: New Holland T8.350, Nebraska Tractor Test Lab Jan 2015

Test 2123a: New Holland T8.350, Nebraska Tractor Test Lab

Nebraska Tractor Tests

ABOUT THE TEST REPORT AND USE OF THE DATA The test data contained in this report are a tabulation of the results of a series of tests. Due to the restricted format of these pages, only a limited amount of data and not all of the tractor specifications are included. The full OECD report contains usually about 30 pages of data and specifications. The test data were obtained for each tractor under similar conditions and therefore, provide a means of comparison of performance based on a limited set of reported data. EXPLANATION OF THE TEST PROCEDURES Purpose The purpose of …


Test 2122a: Case Ih Magnum 250, Nebraska Tractor Test Lab Jan 2015

Test 2122a: Case Ih Magnum 250, Nebraska Tractor Test Lab

Nebraska Tractor Tests

ABOUT THE TEST REPORT AND USE OF THE DATA The test data contained in this report are a tabulation of the results of a series of tests. Due to the restricted format of these pages, only a limited amount of data and not all of the tractor specifications are included. The full OECD report contains usually about 30 pages of data and specifications. The test data were obtained for each tractor under similar conditions and therefore, provide a means of comparison of performance based on a limited set of reported data. EXPLANATION OF THE TEST PROCEDURES Purpose The purpose of …


An Investigation Into Bacterial Contamination In An Urban Nebraska Stream Using Microbial Source Tracking, Allison R. Speicher Jan 2015

An Investigation Into Bacterial Contamination In An Urban Nebraska Stream Using Microbial Source Tracking, Allison R. Speicher

Department of Civil and Environmental Engineering: Dissertations, Theses, and Student Research

High levels of fecal bacteria in surface waters are a public health concern due to the enteric illnesses caused by primary contact with these waters. Shortcomings in the current fecal indicator bacteria (FIB) monitoring approach and the ubiquity of pathogen-impaired water bodies has led to the development of microbial source tracking (MST), a molecular tool that can identify potential fecal contamination sources. In this study we use a bacterial community based approach examining the V4 region of the 16S rRNA gene to elucidate sources of fecal bacteria in Antelope Creek, an urban creek in Lincoln Nebraska.

We hypothesized that sediment …


Stabilizing Electrochemical Carbon Capture Membrane With Al2O3 Thin-Film Overcoating Synthesized By Chemical Vapor Deposition, Jingjing Tong, Fengzhan Si, Lingling Zhang, Jie Fang, Minfang Han, Kevin Huang Jan 2015

Stabilizing Electrochemical Carbon Capture Membrane With Al2O3 Thin-Film Overcoating Synthesized By Chemical Vapor Deposition, Jingjing Tong, Fengzhan Si, Lingling Zhang, Jie Fang, Minfang Han, Kevin Huang

Faculty Publications

Development of high-efficiency and cost-effective carbon capture technology is a central element of our effort to battle the global warming and climate change. Here we report that the unique high-flux and high-selectivity of electrochemical silver-carbonate dual-phase membranes can be retained for an extended period of operation by overcoating the surfaces of porous silver matrix with a uniform layer of Al2O3 thin-film derived from chemical vapor deposition.


La0.7Sr0.3Fe0.7Ga0.3O3-Δ As Electrode Material For A Symmetrical Solid Oxide Fuel Cell, Zhibin Yang, Yu Chen, Chao Jin, Guoliang Xiao, Minfang Han, Fanglin Chen Jan 2015

La0.7Sr0.3Fe0.7Ga0.3O3-Δ As Electrode Material For A Symmetrical Solid Oxide Fuel Cell, Zhibin Yang, Yu Chen, Chao Jin, Guoliang Xiao, Minfang Han, Fanglin Chen

Faculty Publications

In this research, La0.7Sr0.3Fe0.7Ga0.3O3−δ (LSFG) perovskite oxide was successfully prepared using a microwave-assisted combustion method, and employed as both anode and cathode in symmetrical solid oxide fuel cells. A maximum power density of 489 mW cm−2 was achieved at 800 °C with wet H2 as the fuel and ambient air as the oxidant in a single cell with the configuration LSFG|La0.8Sr0.2Ga0.83Mg0.17O3−δ|LSFG. Furthermore, the cells demonstrated good stability in H2 and acceptable sulfur tolerance.


La0.6Sr1.4Mno4+Δ Layered Perovskite Oxide: Enhanced Catalytic Activity For The Oxygen Reduction Reaction, Yarong Wang, Zhibin Yang, Fanliang Liu, Chao Jin, Jiao Wu, Ming Shen, Ruizhi Yang, Fanglin Chen Jan 2015

La0.6Sr1.4Mno4+Δ Layered Perovskite Oxide: Enhanced Catalytic Activity For The Oxygen Reduction Reaction, Yarong Wang, Zhibin Yang, Fanliang Liu, Chao Jin, Jiao Wu, Ming Shen, Ruizhi Yang, Fanglin Chen

Faculty Publications

Efficient electrocatalysts for the oxygen reduction reaction (ORR) is a critical factor to influence the performance of lithium–oxygen batteries. In this study, La0.6Sr1.4MnO4+δ layered perovskite oxide as a highly active electrocatalyst for the ORR has been prepared, and a carbon-coating layer with thickness <5 nm has been successfully introduced to enhance the electronic conductivity of the as-prepared oxide. XRD, XPS, Raman, SEM and TEM measurements were carried out to characterize the crystalline structure and morphology of these samples. Rotating ring-disk electrode (RRDE) technique has been used to study catalytic activities of the as-prepared catalysts for the ORR in 0.1 M KOH media. RRDE results reveal that carbon-coated La0.6Sr1.4MnO4+δ exhibits better catalytic activity for the ORR. For the carbon-coated La0.6Sr1.4MnO4+δ, the ORR proceeds predominately via a direct four electron process, and a maximum cathodic current density of 6.70 mA cm−2 at 2500 rpm has been obtained, …


Nebraska Summary: S1017a Massey Ferguson 7722s, Nebraska Tractor Test Lab Jan 2015

Nebraska Summary: S1017a Massey Ferguson 7722s, Nebraska Tractor Test Lab

Nebraska Tractor Tests

ABOUT THE TEST REPORT AND USE OF THE DATA The test data contained in this report are a tabulation of the results of a series of tests. Due to the restricted format of these pages, only a limited amount of data and not all of the tractor specifications are included. The full OECD report contains usually about 30 pages of data and specifications. The test data were obtained for each tractor under similar conditions and therefore, provide a means of comparison of performance based on a limited set of reported data. EXPLANATION OF THE TEST PROCEDURES Purpose The purpose of …


Nebraska Summary: S996 Challenger Mt665e, Nebraska Tractor Test Lab Jan 2015

Nebraska Summary: S996 Challenger Mt665e, Nebraska Tractor Test Lab

Nebraska Tractor Tests

ABOUT THE TEST REPORT AND USE OF THE DATA The test data contained in this report are a tabulation of the results of a series of tests. Due to the restricted format of these pages, only a limited amount of data and not all of the tractor specifications are included. The full OECD report contains usually about 30 pages of data and specifications. The test data were obtained for each tractor under similar conditions and therefore, provide a means of comparison of performance based on a limited set of reported data. EXPLANATION OF THE TEST PROCEDURES Purpose The purpose of …


Nebraska Summary: S993 Massey Ferguson 8737, Nebraska Tractor Test Lab Jan 2015

Nebraska Summary: S993 Massey Ferguson 8737, Nebraska Tractor Test Lab

Nebraska Tractor Tests

ABOUT THE TEST REPORT AND USE OF THE DATA The test data contained in this report are a tabulation of the results of a series of tests. Due to the restricted format of these pages, only a limited amount of data and not all of the tractor specifications are included. The full OECD report contains usually about 30 pages of data and specifications. The test data were obtained for each tractor under similar conditions and therefore, provide a means of comparison of performance based on a limited set of reported data. EXPLANATION OF THE TEST PROCEDURES Purpose The purpose of …


Nebraska Summary: S994 Challenger Mt645e, Nebraska Tractor Test Lab Jan 2015

Nebraska Summary: S994 Challenger Mt645e, Nebraska Tractor Test Lab

Nebraska Tractor Tests

ABOUT THE TEST REPORT AND USE OF THE DATA The test data contained in this report are a tabulation of the results of a series of tests. Due to the restricted format of these pages, only a limited amount of data and not all of the tractor specifications are included. The full OECD report contains usually about 30 pages of data and specifications. The test data were obtained for each tractor under similar conditions and therefore, provide a means of comparison of performance based on a limited set of reported data. EXPLANATION OF THE TEST PROCEDURES Purpose The purpose of …


Nebraska Summary: S992 Massey Ferguson 8735, Nebraska Tractor Test Lab Jan 2015

Nebraska Summary: S992 Massey Ferguson 8735, Nebraska Tractor Test Lab

Nebraska Tractor Tests

ABOUT THE TEST REPORT AND USE OF THE DATA The test data contained in this report are a tabulation of the results of a series of tests. Due to the restricted format of these pages, only a limited amount of data and not all of the tractor specifications are included. The full OECD report contains usually about 30 pages of data and specifications. The test data were obtained for each tractor under similar conditions and therefore, provide a means of comparison of performance based on a limited set of reported data. EXPLANATION OF THE TEST PROCEDURES Purpose The purpose of …


Nebraska Summary: S991a Massey Ferguson 8732, Nebraska Tractor Test Lab Jan 2015

Nebraska Summary: S991a Massey Ferguson 8732, Nebraska Tractor Test Lab

Nebraska Tractor Tests

ABOUT THE TEST REPORT AND USE OF THE DATA The test data contained in this report are a tabulation of the results of a series of tests. Due to the restricted format of these pages, only a limited amount of data and not all of the tractor specifications are included. The full OECD report contains usually about 30 pages of data and specifications. The test data were obtained for each tractor under similar conditions and therefore, provide a means of comparison of performance based on a limited set of reported data. EXPLANATION OF THE TEST PROCEDURES Purpose The purpose of …


Nebraska Summary: S990 Massey Ferguson 8730, Nebraska Tractor Test Lab Jan 2015

Nebraska Summary: S990 Massey Ferguson 8730, Nebraska Tractor Test Lab

Nebraska Tractor Tests

ABOUT THE TEST REPORT AND USE OF THE DATA The test data contained in this report are a tabulation of the results of a series of tests. Due to the restricted format of these pages, only a limited amount of data and not all of the tractor specifications are included. The full OECD report contains usually about 30 pages of data and specifications. The test data were obtained for each tractor under similar conditions and therefore, provide a means of comparison of performance based on a limited set of reported data. EXPLANATION OF THE TEST PROCEDURES Purpose The purpose of …


Nebraska Summary: S1024 Challenger Mt595e, Nebraska Tractor Test Lab Jan 2015

Nebraska Summary: S1024 Challenger Mt595e, Nebraska Tractor Test Lab

Nebraska Tractor Tests

ABOUT THE TEST REPORT AND USE OF THE DATA The test data contained in this report are a tabulation of the results of a series of tests. Due to the restricted format of these pages, only a limited amount of data and not all of the tractor specifications are included. The full OECD report contains usually about 30 pages of data and specifications. The test data were obtained for each tractor under similar conditions and therefore, provide a means of comparison of performance based on a limited set of reported data. EXPLANATION OF THE TEST PROCEDURES Purpose The purpose of …


Nebraska Summary: S1022 Challenger Mt575e, Nebraska Tractor Test Lab Jan 2015

Nebraska Summary: S1022 Challenger Mt575e, Nebraska Tractor Test Lab

Nebraska Tractor Tests

ABOUT THE TEST REPORT AND USE OF THE DATA The test data contained in this report are a tabulation of the results of a series of tests. Due to the restricted format of these pages, only a limited amount of data and not all of the tractor specifications are included. The full OECD report contains usually about 30 pages of data and specifications. The test data were obtained for each tractor under similar conditions and therefore, provide a means of comparison of performance based on a limited set of reported data. EXPLANATION OF THE TEST PROCEDURES Purpose The purpose of …


Nebraska Summary: S989a Massey Ferguson 8727, Nebraska Tractor Test Lab Jan 2015

Nebraska Summary: S989a Massey Ferguson 8727, Nebraska Tractor Test Lab

Nebraska Tractor Tests

ABOUT THE TEST REPORT AND USE OF THE DATA The test data contained in this report are a tabulation of the results of a series of tests. Due to the restricted format of these pages, only a limited amount of data and not all of the tractor specifications are included. The full OECD report contains usually about 30 pages of data and specifications. The test data were obtained for each tractor under similar conditions and therefore, provide a means of comparison of performance based on a limited set of reported data. EXPLANATION OF THE TEST PROCEDURES Purpose The purpose of …


Nebraska Summary: S991 Massey Ferguson 8732, Nebraska Tractor Test Lab Jan 2015

Nebraska Summary: S991 Massey Ferguson 8732, Nebraska Tractor Test Lab

Nebraska Tractor Tests

ABOUT THE TEST REPORT AND USE OF THE DATA The test data contained in this report are a tabulation of the results of a series of tests. Due to the restricted format of these pages, only a limited amount of data and not all of the tractor specifications are included. The full OECD report contains usually about 30 pages of data and specifications. The test data were obtained for each tractor under similar conditions and therefore, provide a means of comparison of performance based on a limited set of reported data. EXPLANATION OF THE TEST PROCEDURES Purpose The purpose of …


Nebraska Summary: S1019a Massey Ferguson 7726, Nebraska Tractor Test Lab Jan 2015

Nebraska Summary: S1019a Massey Ferguson 7726, Nebraska Tractor Test Lab

Nebraska Tractor Tests

ABOUT THE TEST REPORT AND USE OF THE DATA The test data contained in this report are a tabulation of the results of a series of tests. Due to the restricted format of these pages, only a limited amount of data and not all of the tractor specifications are included. The full OECD report contains usually about 30 pages of data and specifications. The test data were obtained for each tractor under similar conditions and therefore, provide a means of comparison of performance based on a limited set of reported data. EXPLANATION OF THE TEST PROCEDURES Purpose The purpose of …


A Physics-Based Compact Model For Thermoelectric Devices, Kyle Jeffrey Conrad Jan 2015

A Physics-Based Compact Model For Thermoelectric Devices, Kyle Jeffrey Conrad

Open Access Theses

Thermoelectric devices have a wide variety of potential applications including as coolers, temperature regulators, power generators, and energy harvesters. During the past decade or so, new thermoelectric materials have been an active area of research. As a result, several new high figure of merit (zT) materials have been identified, but practical devices using these new materials have not yet been reported. A physics-based compact model could be used to simulate a thermoelectric devices within a full system using SPICE-compatible circuit simulators. If such a model accepts measured or simulated material parameters, it would be useful in exploring the …


Assessing Coupled Mechanical Behavior And Environmental Degradation At Submicron Scales, Samantha K Lawrence Jan 2015

Assessing Coupled Mechanical Behavior And Environmental Degradation At Submicron Scales, Samantha K Lawrence

Open Access Dissertations

Mechanical and electromechanical properties, deformation and fracture mechanisms, and environmental resistance of materials at submicron scales have been investigated through the combination of nanomechanical testing, high resolution microscopy, diffraction, and electrochemical testing. Nanomechanical techniques were used to isolate environmental, orientation, and size effects. Material evaluation focuses on metals, both model and engineering alloys, in bulk and thin-film form as well as oxide-substrate systems. Yield behavior of Ni 200, a model material, depends on sampled volume size, orientation, and surface preparation. Exposure to high-pressure hydrogen gas is also found to impact incipient plasticity and mechanical properties of commercially pure Ni 201. …