Open Access. Powered by Scholars. Published by Universities.®

Engineering Commons™

Open Access. Powered by Scholars. Published by Universities.®

University of Central Florida

Discipline
Keyword
Publication Year
Publication
Publication Type
File Type

Articles 3571 - 3600 of 4566

Full-Text Articles in Engineering

Study Of Delamination In Acceleration Tested Pv Modules, Florida Solar Energy Center, Neelkanth Dhere Oct 2001

Study Of Delamination In Acceleration Tested Pv Modules, Florida Solar Energy Center, Neelkanth Dhere

FSEC Energy Research Center®

The average adhesional shear strength at silicon cell/EVA interface in damp-heat, acceleration-tested modules was ~27% of that measured in new modules. The average carbon concentration at the surface of samples extracted from acceleration tested modules was 15 atomic % or ~30% of that measured in new modules. Surface concentrations of sodium on Si-cell samples from the acceleration tested modules ranged from 4.9 to 22.0 atomic %while those of phosphorous ranged from 4.3 to 7.1 at. %. These are very high impurity concentrations. Often small concentrations of phosphorous were detected at the interface between titanium oxide antireflection coating and silicon cell. …


Preliminary Evaluation Of Energy-Efficiency Improvements To Modular Classrooms, Florida Solar Energy Center, Danny Parker Sep 2001

Preliminary Evaluation Of Energy-Efficiency Improvements To Modular Classrooms, Florida Solar Energy Center, Danny Parker

FSEC Energy Research Center®

The objective of our investigation is to evaluate innovations that would enable modular classroom builders to improve the energy performance of their classrooms. We investigate improved insulation, better windows, daylighting, cross-ventilation, sensible and latent heat recovery of ventilation air and light colored surfaces and radiant barriers for cooling dominated climates. The tasks associated with this work are as follows:

  • Create a simulation software.
  • Establish a baseline reference building using a standard modular classroom building.
  • Parametric evaluation of the impact of ventilation and school schedule on energy use.
  • Determine the feasibility of improving insulation and envelope systems.
  • Determine the feasibility of …


Evaluate Deployment Of Photovoltaic Systems For Disasters, Florida Solar Energy Center, William Young Aug 2001

Evaluate Deployment Of Photovoltaic Systems For Disasters, Florida Solar Energy Center, William Young

FSEC Energy Research Center®

In 1996, the U.S. Department of Energy (DOE), developed a program with the Federal Emergency Management Agency (FEMA) to provide photovoltaic electrical power in disasters. In support of this effort, DOE purchased eight PV-generator trailers which were constructed in 1998 and supplied to FEMA for deployment in disaster response efforts. This report describes past and present use of the trailers, their depot location, list maintenance data, and the viability of the trailers in a disaster.


Photovoltaics In Disaster Management, Florida Solar Energy Center, William Young Aug 2001

Photovoltaics In Disaster Management, Florida Solar Energy Center, William Young

FSEC Energy Research Center®

Man made or natural, disasters can happen at any time, often with little or no advance warning. Major disasters, such as hurricanes, floods, tornados, and earthquakes, can leave many people without adequate medical services, potable water, electrical service and communications. They can be as destructive as Hurricane Mitch leaving several hundred-thousand people homeless or as minor as an afternoon thunderstorm knocking down local power lines to your home.

In response to a disaster, photovoltaic (solar electric) modules offer a source of quiet, safe, pollution-free electrical power. Photovoltaic (PV) power systems are capable of providing the electrical needs for vaccine refrigerators, …


Solar Cooker Reflector Optical Evaluation And Design Evolution, Florida Solar Energy Center, Ross Mccluney Jun 2001

Solar Cooker Reflector Optical Evaluation And Design Evolution, Florida Solar Energy Center, Ross Mccluney

FSEC Energy Research Center®

Solar Cooker Reflector Optical Evaluation and Design Evolution


Developing An Implementation Plan For The Arkansas Msri Coalition Workshop Summary - Final Report, Florida Solar Energy Center, Jennifer Szaro Jun 2001

Developing An Implementation Plan For The Arkansas Msri Coalition Workshop Summary - Final Report, Florida Solar Energy Center, Jennifer Szaro

FSEC Energy Research Center®

Workshop conducted to develop an implementation plan for the Arkansas Million Solar Roofs Initiative.


Developing An Implementation Plan For The Alaskan Msri Coalition Workshop Summary - Final Report, Florida Solar Energy Center, Gerard Ventre Jun 2001

Developing An Implementation Plan For The Alaskan Msri Coalition Workshop Summary - Final Report, Florida Solar Energy Center, Gerard Ventre

FSEC Energy Research Center®

Workshop conducted to develop and implementation plan for the Alaskan Million Solar Roofs Initiative.


Typical Photovoltaic System For A Commercial Building, Florida Solar Energy Center, Gobind Atmaram Jun 2001

Typical Photovoltaic System For A Commercial Building, Florida Solar Energy Center, Gobind Atmaram

FSEC Energy Research Center®

This paper covers the design and installation of an 11 peak kilowatt (kWp) grid-connected photovoltaic system on the roof of the new facilities at the Florida Solar Energy Center (FSEC7). The main objectives of this work are to demonstrate the application of photovoltaics (PV) as a demand-side management option for meeting peak commercial electric loads and provide a typical PV array and system design for commercial buildings. The PV array consists of 48 ASE America=s EFG ribbon silicon modules and is interfaced with three Omnion 4kW power conditioners. The complete array and system electrical design and installation were performed by …


Fsec Procedure For Testing Stand-Alone Photovoltaic Systems, Florida Solar Energy Center May 2001

Fsec Procedure For Testing Stand-Alone Photovoltaic Systems, Florida Solar Energy Center

FSEC Energy Research Center®

This procedure is based on IEEE P1526/D1, Draft Recommended Practice for Testing the Performance of Stand-Alone Photovoltaic Systems. The system performance is based upon how well it can charge the battery. The usable battery capacity is measured by charging and discharging the battery three separate times. The tests are designed to test the overall system performance in the span of about one month.


The Importance Of Site Surveys In Florida's Pv Buildings Program, Florida Solar Energy Center, Kevin Lynn Apr 2001

The Importance Of Site Surveys In Florida's Pv Buildings Program, Florida Solar Energy Center, Kevin Lynn

FSEC Energy Research Center®

One of the goals of the Florida PV Buildings Program is to ensure that only quality utility-interactive PV systems are installed in the state. One important component of the Program is the site survey. The purpose of the site survey is to inspect the potential location for PV system before beginning construction, ensuring it is a sensible place to install it. The purpose of this paper is to introduce the method used by this Program and to present some examples that will demonstrate why it is important.


Fpc Residential Monitoring Project: New Technology Development Radiant Barrier Pilot Project, Florida Solar Energy Center, Danny Parker Jan 2001

Fpc Residential Monitoring Project: New Technology Development Radiant Barrier Pilot Project, Florida Solar Energy Center, Danny Parker

FSEC Energy Research Center®

The FPC Monitoring project has evaluated radiant barrier systems (RBS) as a new potential DSM program. The objective was to examine how the retrofit of attic radiant barriers can be expected to alter FPC residential space conditioning loads. An RBS consists of a layer of aluminum foil fastened to roof decking or roof trusses to block radiant heat transfer between the hot roof surface and the attic below. The radiant barrier can significantly lower summer heat transfer to the attic insulation and to the cooling duct system. Both of these mechanisms have strong potential impacts on cooling energy use as …


Executive Summary - Fpc Residential Monitoring Project: New Technology Development Radiant Barrier Pilot Project, Florida Solar Energy Center, Danny Parker Jan 2001

Executive Summary - Fpc Residential Monitoring Project: New Technology Development Radiant Barrier Pilot Project, Florida Solar Energy Center, Danny Parker

FSEC Energy Research Center®

The FPC Monitoring project has evaluated radiant barrier systems (RBS) as a new potential DSM program. The objective was to examine how the retrofit of attic radiant barriers can be expected to alter FPC residential space conditioning loads. An RBS consists of a layer of aluminum foil fastened to roof decking or roof trusses to block radiant heat transfer between the hot roof surface and the attic below. The radiant barrier can significantly lower summer heat transfer to the attic insulation and to the cooling duct system. Both of these mechanisms have strong potential impacts on cooling energy use as …


Design And Applications Of Volume Holographic Optical Elements, Steven C. Dunn Jan 2001

Design And Applications Of Volume Holographic Optical Elements, Steven C. Dunn

Retrospective Theses and Dissertations

Volume gratings were studied both theoretically and experimentally in order to design and analyze practical volume holographic optical elements. The diffraction of finite (Gaussian) beams by transmission gratings is investigated. A closed form solution for the off-Bragg profiles is obtained, and the distortion in the resulting profiles is analyzed. Criteria for when the finiteness of the beam has a minimal effect on the angular selectivity response are given. A model is developed to investigate the cross talk in multiplexed gratings Experimental verification in LiNb03 and PTR glass is demonstrated. The diffraction efficiency and output profiles of finite beams diffracted …


A Framework For The Implementation Of An Iso 9000 Based Certification Program For Printed Circuit Board Manufacturers, Adam Y. Maamoun Jan 2001

A Framework For The Implementation Of An Iso 9000 Based Certification Program For Printed Circuit Board Manufacturers, Adam Y. Maamoun

Retrospective Theses and Dissertations

ISO 9000:2000 is the newest version of the ISO 9000 family of standards. Unlike the 1994 version, it does not distinguish between servicing, testing and designing standards. It emphasizes quality improvement rather than quality control and briefly explains how to implement the Plan-Do-Check- Act (PDCA) cycle for improvement and the use of statistical techniques to improve the quality of process and product instead of controlling the quality of the output. The thesis explains why companies need to be certified and how to implement quality improvement programs.

The objective of this thesis is to provide generic certification guidelines for printed circuit …


Computing A Diameter-Constrained Minimum Spanning Tree, Ayman Mahmoud Abdalla Jan 2001

Computing A Diameter-Constrained Minimum Spanning Tree, Ayman Mahmoud Abdalla

Retrospective Theses and Dissertations

In numerous practical applications, it is necessary to find the smallest possible tree with a bounded diameter. A diameter-constrained minimum spanning tree (DCMST) of a given undirected, edge-weighted graph, G, is the smallest-weight spanning tree of all spanning trees of G which contain no path with more than k edges, where k is a given positive integer. The problem of finding a DCMST is NP-complete for all values of k; 4 ≤ k ≤ (n - 2), except when all edge-weights are identical.

A DCMST is essential for the efficiency of various distributed mutual exclusion algorithms, where …


Use Of Incremental Adaptation And Habituation Regimens For Mitigating Optokinetic Side-Effects, David A. Graeber Jan 2001

Use Of Incremental Adaptation And Habituation Regimens For Mitigating Optokinetic Side-Effects, David A. Graeber

Retrospective Theses and Dissertations

The use of incremental and repeated exposures regimens have been put forth as effective means to mitigate visually induced motion sickness based on the Dual Process Theory (DPT) (Groves & Thompson, 1970) of neural plasticity. In essence, DPT suggests that by incrementing stimulus intensity the depression opponent process should be allowed to exert greater control over the net outcome than the sensitization opponent process, thereby minimizing side-effects. This conceptual model was tested by empirically validating the effectiveness of adaptation, incremental adaptation, habituation, and incremental habituation regimens to mitigate side-effects arising from exposure to an optokinetic drum. Forty college students from …


Low Voltage Regulator Modules And Single Stage Front-End Converters, Wei Gu Jan 2001

Low Voltage Regulator Modules And Single Stage Front-End Converters, Wei Gu

Retrospective Theses and Dissertations

Evolution in microprocessor technology poses new challenges for supplying power to these devices. To meet demands for faster and more efficient data processing, modem microprocessors are being designed with lower voltage implementations. More devices will be packed on a single processor chip and the processors will operate at higher frequencies, exceeding 1GHz. New high-performance microprocessors may require from 40 to 80 watts of power for the CPU alone. Load current must be supplied with up to 30A/µs slew rate while keeping the output voltage within tight regulation and response time tolerances. Therefore, special power supplies and Voltage Regulator Modules (VRMs) …


Study Of Photoelectrochemical Cells For Hydrogen Production By Water Splitting Using Cigs2/Cds Heterojunction, Florida Solar Energy Center, Neelkanth Dhere Dec 2000

Study Of Photoelectrochemical Cells For Hydrogen Production By Water Splitting Using Cigs2/Cds Heterojunction, Florida Solar Energy Center, Neelkanth Dhere

FSEC Energy Research Center®

Study of Photoelectrochemical Cells for Hydrogen Production by Water Splitting Using CIGS2/CdS Heterojunction


Industry Guide To Selecting The Best Residential Window Options For The Florida Climate, Florida Solar Energy Center, Ross Mccluney Dec 2000

Industry Guide To Selecting The Best Residential Window Options For The Florida Climate, Florida Solar Energy Center, Ross Mccluney

FSEC Energy Research Center®

It used to be said that windows are little more than holes in the insulation. It is true to some extent that poorly insulated and drafty windows in certain climates defeat the purpose of wall insulation. However, modern high performance windows are almost as good as opaque insulated wall sections, at least in terms of total energy savings over long periods of time. In some cases, they can be shown to actually out-perform insulated walls. Of course, they have the priceless additional benefits of providing views to the outdoors and natural daylight illumination indoors important issues of quality and comfort. …


Executive Summary: Comparative Evaluation Of The Impact Of Roofing Systems On Residential Cooling Energy Demand In Florida, Florida Solar Energy Center, John Sherwin Nov 2000

Executive Summary: Comparative Evaluation Of The Impact Of Roofing Systems On Residential Cooling Energy Demand In Florida, Florida Solar Energy Center, John Sherwin

FSEC Energy Research Center®

Roof and attic thermal performance exert a powerful influence on cooling energy use in Florida homes. Unshaded residential roofs are heated by solar radiation causing high afternoon attic air temperatures. The large influence on cooling is due to increased ceiling heat transfer as well as heat gains to the duct systems which are typically located in the attic space (Figure E-1). The Florida Power and Light Company and the Florida Solar Energy Center instrumented six side-by-side Habitat homes in Ft. Myers, Florida with identical floor plans and orientation, R-19 ceiling insulation, but with different roofing systems designed to reduce attic …


Evaluating The Impacts Of Uncontrolled Air Flow And Hvac Performance Problems On Florida's Commercial And Institutional Buildings - Final Report, Florida Solar Energy Center, James Cummings Oct 2000

Evaluating The Impacts Of Uncontrolled Air Flow And Hvac Performance Problems On Florida's Commercial And Institutional Buildings - Final Report, Florida Solar Energy Center, James Cummings

FSEC Energy Research Center®

Twenty commercial and institutional buildings located in central Florida were tested for uncontrolled air flow and cooling system problems. Tested buildings were selected based on three criteria; 1) buildings with large exhaust fans, 2) buildings with leaky ceilings, and 3) education buildings. They ranged in size from a 650 square foot portable classroom to a 50,000 square foot elementary school, with an average floor area of 6518 square feet.

Diagnostic inspection and testing was performed in each building to identify problems related to uncontrolled air flow or HVAC system or control problems. The tests were performed to characterize or identify …


Developing An Implementation Plan For The Idaho Msri Partnership Workshop Summary - Final Report, Florida Solar Energy Center, Jennifer Szaro Oct 2000

Developing An Implementation Plan For The Idaho Msri Partnership Workshop Summary - Final Report, Florida Solar Energy Center, Jennifer Szaro

FSEC Energy Research Center®

Workshop conducted to develop an implementation plan for the Idaho Million Solar Roofs Initiative.


Validation Of Energygauge® Usa Using The Hers Bestest Procedure, Florida Solar Energy Center, Philip W. Fairey Oct 2000

Validation Of Energygauge® Usa Using The Hers Bestest Procedure, Florida Solar Energy Center, Philip W. Fairey

FSEC Energy Research Center®

This report presents results from the testing and validation of the EnergyGauge USA home energy rating software conducted using the HERS BESTEST procedures. The results show that EnergyGauge USA is an excellent and verifiable simulation program that is capable of meeting all national requirements for home energy rating software tools.


The Hers Rating Method And The Derivation Of The Normalized Modified Loads Method, Florida Solar Energy Center, Philip W. Fairey Oct 2000

The Hers Rating Method And The Derivation Of The Normalized Modified Loads Method, Florida Solar Energy Center, Philip W. Fairey

FSEC Energy Research Center®

This paper provides much of the historical background surrounding the contentious development of a national, uniform rating method for rating the energy-efficiency of homes. A full derivation of the most recently adopted rating method, the Normalized Modified Loads Method, is provided in detail and the issues and events leading up to the development of each of the succeeding methods are described.

Ever since the inclusion of Home Energy Rating Systems in the 1992 Energy Policy Act, the most contentious issue associated with them has been the development of a uniform rating method. To date, four succeeding methods have been proposed: …


Developing An Implementation Plan For The Montana Msri Coalition Workshop Summary - Final Report, Florida Solar Energy Center, Jennifer Szaro Oct 2000

Developing An Implementation Plan For The Montana Msri Coalition Workshop Summary - Final Report, Florida Solar Energy Center, Jennifer Szaro

FSEC Energy Research Center®

Workshop was conducted to develop an implementation plan for the Montana Million Solar Roofs Initiative.


Evaluation Of Resources And Energy Systems At Dry Tortugas National Park, Addendum Report, Florida Solar Energy Center, James Dunlop Sep 2000

Evaluation Of Resources And Energy Systems At Dry Tortugas National Park, Addendum Report, Florida Solar Energy Center, James Dunlop

FSEC Energy Research Center®

The objectives of this report are to identify opportunities for increasing efficiency, reducing costs and improving environmental quality by implementing conservation measures and renewable energy systems in park operations. Information in this report was derived from a site survey conducted on April 4-6, 2000 by personnel from the National Park Service (NPS), U.S. Department of Energy (DOE), Sandia National Laboratories (SNL), Oak Ridge National Laboratory (ORNL) and Florida Solar Energy Center (FSEC). It builds on earlier site assessments and reports developed in 1989 and 1997 by FSEC under contract to DOE and SNL


Energy Efficient Design For Florida Educational Facilities, Florida Solar Energy Center, Janet Mcilvaine Sep 2000

Energy Efficient Design For Florida Educational Facilities, Florida Solar Energy Center, Janet Mcilvaine

FSEC Energy Research Center®

This manual addresses energy efficiency options for new educational facilities in Florida. The recommendations may not be valid when considered outside Florida's hot humid climate or for purposes other than new construction.

Construction funds spent on new construction heavily outweigh (67%) those spent on retrofit, as reported in an annual statistical analysis published by American School and University (September 1992). The comprehensive survey showed that construction funds for new educational facilities nationwide have risen for eight consecutive years, and no region has experienced more growth than the Southeast. Currently, funds spent on energy services (excluding capital outlay, salaries, benefits, and …


Improving Doe-2'S Resys Routine: User Defined Functions To Provide More Accurate Part Load Energy Use And Humidity Predictions, Florida Solar Energy Center, Hugh Henderson, Jr. Aug 2000

Improving Doe-2'S Resys Routine: User Defined Functions To Provide More Accurate Part Load Energy Use And Humidity Predictions, Florida Solar Energy Center, Hugh Henderson, Jr.

FSEC Energy Research Center®

In hourly energy simulations, it is important to properly predict the performance of air conditioning systems over a range of full and part load operating conditions. An important component of these calculations is to properly consider the performance of the cycling air conditioner and how it interacts with the building. This paper presents improved approaches to properly account for the part load performance of residential and light commercial air conditioning systems in DOE-2. First, more accurate correlations are given to predict the degradation of system efficiency at part load conditions. In addition, a user-defined function for RESYS is developed that …


Factors Influencing Space Heat And Heat Pump Efficiency From A Large-Scale Residential Monitoring Study, Florida Solar Energy Center, Matthew Bouchelle Aug 2000

Factors Influencing Space Heat And Heat Pump Efficiency From A Large-Scale Residential Monitoring Study, Florida Solar Energy Center, Matthew Bouchelle

FSEC Energy Research Center®

Since Florida utilities often experience their system peak during the state's few cold mornings, understanding influences on space heat performance is important to controlling demand. Analysis of heat pump impacts on system load in a large scale monitoring study have shown large levels of strip heat being used during the winter morning peak. The implied coefficient of performance of heat pumps during the system peak hour was only 1.30. Also, analysis of the total seasonal space heat has shown that the implied Heating Season Performance Factor (HSPF) of heat pump homes is only 4.4 Btu/W rather than the 6-8 Btu/W …


Hidden Power Drains: Trends In Residential Heating And Cooling Fan Watt Power Demand, Florida Solar Energy Center, John Proctor Aug 2000

Hidden Power Drains: Trends In Residential Heating And Cooling Fan Watt Power Demand, Florida Solar Energy Center, John Proctor

FSEC Energy Research Center®

This paper compiles power draw, air flow, and static pressure measurements of residential air handlers taken during nine separate field tests of space conditioning systems in Arizona, California, Florida, Nevada, and Canada. The field tests show that air handler devices do not meet basic performance standards and that the interactions between components combine to further degrade overall system efficiency. The findings support conclusions from previous research in Canada that called for a systems approach to improving air handler efficiency. This study reports that fan power consumption in U.S. air conditioners is about 40% higher than estimates used in the DOE …