Open Access. Powered by Scholars. Published by Universities.®

Engineering Commons™

Open Access. Powered by Scholars. Published by Universities.®

Biomedical Engineering and Bioengineering

Institution
Keyword
Publication Year
Publication
Publication Type
File Type

Articles 7291 - 7320 of 11481

Full-Text Articles in Engineering

A Subject-Specific Multiscale Model Of Transcranial Magnetic Stimulation, Brian Daniel Goodwin Oct 2014

A Subject-Specific Multiscale Model Of Transcranial Magnetic Stimulation, Brian Daniel Goodwin

Dissertations (1934 -)

Transcranial magnetic stimulation (TMS) is a neuromodulation technique used to treat a variety of neurological disorders. While many types of neuromodulation therapy are invasive, TMS is an attractive alternative because it is noninvasive and has a very strong safety record. However, clinical use of TMS has preceded a thorough scientific understanding: its mechanisms of action remain elusive, and the spatial extent of modulation is not well understood. We created a subject-specific, multiscale computational model to gain insights into the physiological response during motor cortex TMS. Specifically, we developed an approach that integrates three main components: 1) a high-resolution anatomical MR …


Pixel-Based Absorption Correction For Dual-Tracer Fluorescence Imaging Of Receptor Binding Potential, Stephen C. Kanick, Kenneth M. Tichauer, Jason Gunn, Kimberley S. Samkoe, Brian W. Pogue Oct 2014

Pixel-Based Absorption Correction For Dual-Tracer Fluorescence Imaging Of Receptor Binding Potential, Stephen C. Kanick, Kenneth M. Tichauer, Jason Gunn, Kimberley S. Samkoe, Brian W. Pogue

Dartmouth Scholarship

Ratiometric approaches to quantifying molecular concentrations have been used for decades in microscopy, but have rarely been exploited in vivo until recently. One dual-tracer approach can utilize an untargeted reference tracer to account for non-specific uptake of a receptor-targeted tracer, and ultimately estimate receptor binding potential quantitatively. However, interpretation of the relative dynamic distribution kinetics is confounded by differences in local tissue absorption at the wavelengths used for each tracer. This study simulated the influence of absorption on fluorescence emission intensity and depth sensitivity at typical near-infrared fluorophore wavelength bands near 700 and 800 nm in mouse skin in order …


Within-Socket Myoelectric Prediction Of Continuous Ankle Kinematics For Control Of A Powered Transtibial Prosthesis, Samuel Farmer, M. Barbara Silver-Thorn, Philip A. Voglewede, Scott A. Beardsley Oct 2014

Within-Socket Myoelectric Prediction Of Continuous Ankle Kinematics For Control Of A Powered Transtibial Prosthesis, Samuel Farmer, M. Barbara Silver-Thorn, Philip A. Voglewede, Scott A. Beardsley

Biomedical Engineering Faculty Research and Publications

Objective. Powered robotic prostheses create a need for natural-feeling user interfaces and robust control schemes. Here, we examined the ability of a nonlinear autoregressive model to continuously map the kinematics of a transtibial prosthesis and electromyographic (EMG) activity recorded within socket to the future estimates of the prosthetic ankle angle in three transtibial amputees. Approach. Model performance was examined across subjects during level treadmill ambulation as a function of the size of the EMG sampling window and the temporal 'prediction' interval between the EMG/kinematic input and the model's estimate of future ankle angle to characterize the trade-off between model error, …


Apparatus And Method For Remote Assessment And Therapy Management In Medical Devices Via Interface Systems, Jeffrey Hargrove, Robert M. Ford, Thomas B. Johnson Sep 2014

Apparatus And Method For Remote Assessment And Therapy Management In Medical Devices Via Interface Systems, Jeffrey Hargrove, Robert M. Ford, Thomas B. Johnson

Mechanical Engineering Patents

A remote medical assessment and therapy management apparatus comprising a center user interface, a center computer coupleable with the center user interface. The center computer displays information via the center user interface for use in developing a therapeutic prescription and receives therapeutic control inputs from a user. A remote device includes a medical diagnostic instrument for acquiring biophysical data from a patient, a medical therapeutic instrument that provides a therapy to the patient, and a remote computer that receives diagnostic signals from the diagnostic instrument and transmits therapeutic control signals to the therapeutic instrument. A network interface is connected between …


Carboxymethylcellulose Hydrogels Support Central Nervous System-Derived Tumor-Cell Chemotactic Migration: Comparison With Conventional Extracellular Matrix Macromolecules, Tanya Singh, Chandrasekhar Kothapalli, Devika Varma, Steven B. Nicoll, Maribel Vazquez Sep 2014

Carboxymethylcellulose Hydrogels Support Central Nervous System-Derived Tumor-Cell Chemotactic Migration: Comparison With Conventional Extracellular Matrix Macromolecules, Tanya Singh, Chandrasekhar Kothapalli, Devika Varma, Steven B. Nicoll, Maribel Vazquez

Publications and Research

The local microenvironment plays an important role in maintaining the dynamics of the extracellular matrix and the cell-extracellular matrix relationship. The extracellular matrix is a complex network of macromolecules with distinct mechanical and biochemical characteristics. Disruptions in extracellular matrix homeostasis are associated with the onset of cancer. The extracellular matrix becomes highly disorganized, and the cell-matrix relationship changes, resulting in altered cell-signaling processes and metastasis. Medulloblastoma is one of the most common malignant pediatric brain tumors in the United States. In order to gain a better understanding of the interplay between cell-extracellular matrix interactions and cell-migratory responses in tumors, eight …


Breast Cancer Detection Using Interferometric Music: Experimental And Numerical Assessment, Giuseppe Ruvio, Raffaele Solimene, Antonio Cuccaro, Domenico Gaetano, Jacinta Browne, Max Ammann Sep 2014

Breast Cancer Detection Using Interferometric Music: Experimental And Numerical Assessment, Giuseppe Ruvio, Raffaele Solimene, Antonio Cuccaro, Domenico Gaetano, Jacinta Browne, Max Ammann

Articles

Purpose: In microwave breast cancer detection, it is often beneficial to arrange sensors in close proximity to the breast. The resultant coupling generally changes the antenna response. As an a priori characterization of the radio frequency system becomes difficult, this can lead to severe degradation of the detection efficacy. The purpose of this paper is to demonstrate the advantages of adopting an interferometric multiple signal classification (I-MUSIC) approach due to its limited dependence from a priori information on the antenna. The performance of I-MUSIC detection was measured in terms of signal-to-clutter ratio (SCR), signal-to-mean ratio (SMR), and spatial displacement (SD) …


Cutaneous Electrode Positioning, Jeffrey Hargrove, Susan R. Briggs Sep 2014

Cutaneous Electrode Positioning, Jeffrey Hargrove, Susan R. Briggs

Mechanical Engineering Patents

A device and method for positioning a cutaneous electrode for delivery of electrical stimulation to a subject's head. A harness is worn on a subject's head with a first band of the harness worn in a closed loop around the subject's head and around a desired contact location on the subject's head. A tensioning strap of the harness is worn across the desired contact location and connected at spaced-apart attachment locations of the strap to spaced-apart attachment locations of the harness such that an electrode disposed over the desired contact location on the subject's head is held in place by …


A Collagen‐Glycosaminoglycan‐Fibrin Scaffold For Heart Valve Tissue Engineering Applications, Claire Brougham, Stefan Jockenhoevel, Thomas Flanagan, Fergal O'Brien Sep 2014

A Collagen‐Glycosaminoglycan‐Fibrin Scaffold For Heart Valve Tissue Engineering Applications, Claire Brougham, Stefan Jockenhoevel, Thomas Flanagan, Fergal O'Brien

Conference Papers

The field of heart valve biology and tissue engineering a heart valve continue to expand. The presentatio ns at this meeting reflect the advances made in both areas due to the multi-disciplinary approach taken by many laboratories.


Monitoring Micelle Formation In Mixtures Of Linear And Foldon-Capped Polypeptides With Light Scattering Spectroscopy, Janna Mino, John P. Gavin, Michael G. Price, Kiril Streletzky, Nolan Holland Sep 2014

Monitoring Micelle Formation In Mixtures Of Linear And Foldon-Capped Polypeptides With Light Scattering Spectroscopy, Janna Mino, John P. Gavin, Michael G. Price, Kiril Streletzky, Nolan Holland

Undergraduate Research Posters 2014

Elastin-like polypeptide (ELP) polymers are ideal for producing environmentally responsive micellar systems because they exhibit a transition from being water-soluble at low temperatures to phase-separated at high temperatures. For application development of drug delivery vehicles and biosensing nanoparticles, it is important to prepare spherical micelles of controlled diameter and shape. Since at a given salt concentration, the headgroup area for each foldon should be constant, the size of the micelles is expected to be proportional to the volume of the linear ELP available per foldon headgroup. Therefore, adding linear ELPs to a system of ELP-foldon should result in changes of …


Comparison Of Electronic And Mechanical Handgrip Devices In Lowering Blood Pressure, Katie Webb, Brandon Musarra, Megan O’Keefe, Shana Strunk, Courtney Perkins, Kenneth E. Sparks, Emily Kullman, Eddie T.C. Lam Sep 2014

Comparison Of Electronic And Mechanical Handgrip Devices In Lowering Blood Pressure, Katie Webb, Brandon Musarra, Megan O’Keefe, Shana Strunk, Courtney Perkins, Kenneth E. Sparks, Emily Kullman, Eddie T.C. Lam

Undergraduate Research Posters 2014

Hypertension causes billions of deaths per year (Millar et al., 2013). The Zona PlusTM is an expensive tool designed to lower blood pressure (BP) using isometric exercise. This exercise may be achieved using a less expensive Handgrip Dynamometer. PURPOSE: The purpose of this research is to determine if the Zona or Handgrip Dynamometer is more efficient at lowering BP and most cost effective for patients. METHODS: Twenty subjects used the Zona and twenty subjects used the dynamometer three times per week for six weeks. BP was taken once per week prior to the treatment. A maximum voluntary contraction (MVC) was …


Anatomy-Based Transmission Factors For Technique Optimization In Portable Chest X-Ray, Chris L. Liptak, W. Paul Segars, Ashraf G. Morgan, Frank F. Dong, Xiang Li Sep 2014

Anatomy-Based Transmission Factors For Technique Optimization In Portable Chest X-Ray, Chris L. Liptak, W. Paul Segars, Ashraf G. Morgan, Frank F. Dong, Xiang Li

Undergraduate Research Posters 2014

Currently, portable x-ray examinations do not employ automatic exposure control (AEC). To aid in the design of a size-specific technique chart, acrylic slabs of various thicknesses are often used to estimate x-ray transmission factors for patients of various body thicknesses. This approach, while simple, does not account for patient anatomy, tissue heterogeneity, and the attenuation properties of the human body. To better account for these factors, in this work, we determined x-ray transmission factors using computational patient models that are anatomically realistic. A Monte Carlo program was developed to model a portable x-ray system. Detailed modeling was done of the …


3d Cultures Of Human Liver Cell Lines Encapsulated In Puramatrix On A Microarray Chip Platform, Pratap Lama, Alexander D. Roth, Pranav Joshi, Akshata Datar, Moo-Yeal Lee Sep 2014

3d Cultures Of Human Liver Cell Lines Encapsulated In Puramatrix On A Microarray Chip Platform, Pratap Lama, Alexander D. Roth, Pranav Joshi, Akshata Datar, Moo-Yeal Lee

Undergraduate Research Posters 2014

A high-throughput cell printing technology has developed to simulate the liver tissue environment using a hydrogel-based chip platform that has potential to shift in vivo drug toxicity models towards in vitro tests. However, the hydrophobic nature of polystyrene chips is not promoting direct adhesion of hydrogels, which created a problem with spot attachment. The main goal of this research is to create a surface chemistry that helps to attach a peptide-based hydrogel, including PuraMatrix, to a polystyrenebased micropillar chip. Seven analogs of maleic anhydride co-polymers were used to coat the micropillar chip to create a functional surface. Then, six ionic …


Sub-Diffusive Scattering Parameter Maps Recovered Using Wide-Field High-Frequency Structured Light Imaging, Stephen C. Kanick, David M. Mcclatchy, Venkataramanan Krishnaswamy, Jonathan T. Elliott, Keith D. Paulsen, Brian W. Pogue Sep 2014

Sub-Diffusive Scattering Parameter Maps Recovered Using Wide-Field High-Frequency Structured Light Imaging, Stephen C. Kanick, David M. Mcclatchy, Venkataramanan Krishnaswamy, Jonathan T. Elliott, Keith D. Paulsen, Brian W. Pogue

Dartmouth Scholarship

This study investigates the hypothesis that structured light reflectance imaging with high spatial frequency patterns (fx) can be used to quantitatively map the anisotropic scattering phase function distribution (P(θs)) in turbid media. Monte Carlo simulations were used in part to establish a semi-empirical model of demodulated reflectance (Rd) in terms of dimensionless scattering (μ′sf−1x) and γ, a metric of the first two moments of the P(θs) distribution. Experiments completed in tissue-simulating phantoms showed that simultaneous analysis of Rd spectra sampled at multiple f …


Computational Modeling Of Pathophysiologic Responses To Exercise In Fontan Patients, Ethan Kung, James C. Perry, Christopher Davis, Francesco Migliavacca, Giancarlo Pennati, Alessandro Giardini, Tain-Yen Hsia, Alison Marsden Sep 2014

Computational Modeling Of Pathophysiologic Responses To Exercise In Fontan Patients, Ethan Kung, James C. Perry, Christopher Davis, Francesco Migliavacca, Giancarlo Pennati, Alessandro Giardini, Tain-Yen Hsia, Alison Marsden

Publications

Reduced exercise capacity is nearly universal among Fontan patients. Although many factors have emerged as possible contributors, the degree to which each impacts the overall hemodynamics is largely unknown. Computational modeling provides a means to test hypotheses of causes of exercise intolerance via precisely controlled virtual experiments and measurements. We quantified the physiological impacts of commonly encountered, clinically relevant dysfunctions introduced to the exercising Fontan system via a previously developed lumped-parameter model of Fontan exercise. Elevated pulmonary arterial pressure was observed in all cases of dysfunction, correlated with lowered cardiac output (CO), and often mediated by elevated atrial pressure. Pulmonary …


Implementation And Validation Of Aortic Remodeling In Hypertensive Rats, Shijia Zhao, Linxia Gu Sep 2014

Implementation And Validation Of Aortic Remodeling In Hypertensive Rats, Shijia Zhao, Linxia Gu

Department of Mechanical and Materials Engineering: Faculty Publications

A computational framework was implemented and validated to better understand the hypertensive artery remodeling in both geometric dimensions and material properties. Integrating the stress-modulated remodeling equations into commercial finite element codes allows a better control and visualization of local mechanical parameters. Both arterial thickening and stiffening effects were captured and visualized. An adaptive material remodeling strategy combined with the element birth and death techniques for the geometrical growth were implemented. The numerically predicted remodeling results in terms of the wall thickness, inner diameter, and the ratio of elastin to collagen content of the artery were compared with and fine-tuned by …


Reduced Diaphyseal Strength Associated With High Intracortical Vascular Porosity Within Long Bones Of Children With Osteogenesis Imperfecta, Carolyne Albert, John Jameson, Peter Smith, Gerald F. Harris Sep 2014

Reduced Diaphyseal Strength Associated With High Intracortical Vascular Porosity Within Long Bones Of Children With Osteogenesis Imperfecta, Carolyne Albert, John Jameson, Peter Smith, Gerald F. Harris

Biomedical Engineering Faculty Research and Publications

Osteogenesis imperfecta is a genetic disorder resulting in bone fragility. The mechanisms behind this fragility are not well understood. In addition to characteristic bone mass deficiencies, research suggests that bone material properties are compromised in individuals with this disorder. However, little data exists regarding bone properties beyond the microstructural scale in individuals with this disorder.

Specimens were obtained from long bone diaphyses of nine children with osteogenesis imperfecta during routine osteotomy procedures. Small rectangular beams, oriented longitudinally and transversely to the diaphyseal axis, were machined from these specimens and elastic modulus, yield strength, and maximum strength were measured in three-point …


Entrepreneurship In Capstone Design: Has The Pendulum Swung Too Far?, Jay R. Goldberg Sep 2014

Entrepreneurship In Capstone Design: Has The Pendulum Swung Too Far?, Jay R. Goldberg

Biomedical Engineering Faculty Research and Publications

The author supports entrepreneurial education for all interested students, but not at the expense of design education. He thinks we should develop business literacy among all of our students to prepare them for work in start-ups and established medical device companies, and provide opportunities for interested students to add entrepreneurial literacy to better prepare them to create new companies, either upon graduation or later in their careers. Capstone design courses should focus on helping students develop solid design skills and providing opportunities to apply the analytical tools learned in previous courses. Students should be encouraged, not required, to consider commercializing …


How Sensitive Is The Deltoid Moment Arm To Joint Center Changes With Rtsa?, David Walker, Allison Kinney, Aimee Struk, Benjamin J. Fregly, Thomas Wright, Scott Banks Sep 2014

How Sensitive Is The Deltoid Moment Arm To Joint Center Changes With Rtsa?, David Walker, Allison Kinney, Aimee Struk, Benjamin J. Fregly, Thomas Wright, Scott Banks

Mechanical and Aerospace Engineering Faculty Publications

The goal of this study was to assess the sensitivity of the deltoid muscle moment arms as a function of joint configuration for an existing RTSA subject. High variations were found for all three deltoid components. Variation over the entire abduction arc was greatest in the anterior and lateral deltoid, while the posterior deltoid moment arm was mostly sensitive to joint center changes early in the abduction arc. Moment arm changes of 10-16mm represent a significant amount of the total deltoid moment arm. This means there is an opportunity to dramatically change the deltoid moments arms through surgical placement of …


Deltoid Moment Arms During Abduction: A Subject-Specific Musculoskeletal Modeling Study In Healthy Shoulders And Shoulders With Rtsa, David Walker, Allison Kinney, Aimee Struk, Benjamin J. Fregly, Thomas Wright, Scott Banks Sep 2014

Deltoid Moment Arms During Abduction: A Subject-Specific Musculoskeletal Modeling Study In Healthy Shoulders And Shoulders With Rtsa, David Walker, Allison Kinney, Aimee Struk, Benjamin J. Fregly, Thomas Wright, Scott Banks

Mechanical and Aerospace Engineering Faculty Publications

Reverse total shoulder arthroplasty (RTSA) is increasingly used in the United States since approval by the FDA in 2003. RTSA relieves pain and restores mobility in arthritic rotator cuff deficient shoulders. Though many advantages of RTSA have been demonstrated, there still are a variety of complications (implant loosening, shoulder impingement, infection, frozen shoulder) making apparent much still is to be learned how RTSA modifies normal shoulder function. The goal of this study was to assess how RTSA affects deltoid muscle moment generating capacity post-surgery using a subjectspecific computational model driven by in vivo kinematic data.


A Novel Approach To Estimation Of Patient-Specific Muscle Strength, David Walker, Allison Kinney, Benjamin J. Fregly, Thomas Wright, Scott Banks Sep 2014

A Novel Approach To Estimation Of Patient-Specific Muscle Strength, David Walker, Allison Kinney, Benjamin J. Fregly, Thomas Wright, Scott Banks

Mechanical and Aerospace Engineering Faculty Publications

Current modeling techniques have been used to model the Reverse Total Shoulder Arthroplasty (RTSA) to account for the geometric changes implemented after RTSA. Though these models have provided insight into the effects of geometric changes from RTSA these is still a limitation of understanding muscle function after RTSA on a patient-specific basis. The goal of this study sought to overcome this limitation by developing an approach to calibrate patient-specific muscle strength for an RTSA subject.


Development, Characterization, And Optimization Of Process For Minimal Functional Barrier And Channel Width In Nitrocellulose Paper Microfluidic Diagnostic Platforms, Ryan Daniel Silva Sep 2014

Development, Characterization, And Optimization Of Process For Minimal Functional Barrier And Channel Width In Nitrocellulose Paper Microfluidic Diagnostic Platforms, Ryan Daniel Silva

Biomedical Engineering

A central goal of diagnostic microfluidics is to reduce the cost of diagnostic medicine by reducing the equipment and reagents needed to perform diagnostic tests. The literature has demonstrated that a wax printer can be used to pattern nitrocellulose paper with hydrophobic barriers to direct a sample in a defined reaction path, eliminating the need for external pumps and controllers. However, manufacturing methods for minimizing sample volume (and thus reagent volume) in a paper-diagnostic chip have not been well defined. In this work, we experimentally determine manufacturing processes for creating functional features of minimal size—effectively reducing the sample size and …


Implementation And Validation Of Aortic Remodeling In Hypertensive Rats, Shijia Zhao, Linxia Gu Sep 2014

Implementation And Validation Of Aortic Remodeling In Hypertensive Rats, Shijia Zhao, Linxia Gu

Department of Mechanical and Materials Engineering: Faculty Publications

A computational framework was implemented and validated to better understand the hypertensive artery remodeling in both geometric dimensions and material properties. Integrating the stress-modulated remodeling equations into commercial finite element codes allows a better control and visualization of local mechanical parameters. Both arterial thickening and stiffening effects were captured and visualized. An adaptive material remodeling strategy combined with the element birth and death techniques for the geometrical growth were implemented. The numerically predicted remodeling results in terms of the wall thickness, inner diameter, and the ratio of elastin to collagen content of the artery were compared with and fine-tuned by …


Virus-Host Mucosal Interactions During Early Siv Rectal Transmission, Wuxun Lu, Fangrui Ma, Alexander Churbanov, Yanmin Wan, Yue Li, Guobin Kang, Zhe Yuan, Dong Wang, Chi Zhang, Jianqing Xu, Mark Lewis, Qingsheng Li Sep 2014

Virus-Host Mucosal Interactions During Early Siv Rectal Transmission, Wuxun Lu, Fangrui Ma, Alexander Churbanov, Yanmin Wan, Yue Li, Guobin Kang, Zhe Yuan, Dong Wang, Chi Zhang, Jianqing Xu, Mark Lewis, Qingsheng Li

Nebraska Center for Biotechnology: Faculty and Staff Publications

To deepen our understanding of early rectal transmission of HIV-1, we studied virus-host interactions in the rectal mucosa using simian immunodeficiency virus (SIV)-Indian rhesus macaque model and mRNA deep sequencing. We found that rectal mucosa actively responded to SIV as early as 3 days post-rectal inoculation (dpi) and mobilized more robust responses at 6 and 10 dpi. Our results suggests that the failure of the host to contain virus replication at the portal of entry is attributable to both a high-level expression of lymphocyte chemoattractant, proinflammatory and immune activation genes, which can recruit and activate viral susceptible target cells into …


An Experimental Study Of The Implementation Of A Fluid Diode Inside A Sano Shunt, Patrick Austin Lane Sep 2014

An Experimental Study Of The Implementation Of A Fluid Diode Inside A Sano Shunt, Patrick Austin Lane

Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research

Fluid diodes are fluidic devices that enhance fluid flow in a particular direction while inhibiting it in the opposite direction without the use of moving parts. This is accomplished through the use of nozzle shaped geometry on one side of the diode, and cusp shaped geometry on the opposing side. Fluid meets very little resistance as is travels though the nozzle side of the diode. The cusps on the other side of the diode reduce the effective flow area, thereby inhibiting flow. The objective of this study is to determine the effectiveness of a fluid diode installed in a reconstructed …


Image Reconstruction In Photoacoustic Computed Tomography With Acoustically Heterogeneous Media, Chao Huang Sep 2014

Image Reconstruction In Photoacoustic Computed Tomography With Acoustically Heterogeneous Media, Chao Huang

All Theses and Dissertations (ETDs)

Photoacoustic computed tomography (PACT), also known as optoacoustic or thermoacoustic tomography, is a rapidly emerging hybrid imaging modality that combines optical image contrast with ultrasound detection. The majority of currently available PACT image reconstruction algorithms are based on idealized imaging models that assume a lossless and acoustically homogeneous medium. However, in many applications of PACT these assumptions are violated and the induced photoacoustic (PA) wavefields are scattered and absorbed as they propagate to the receiving transducers. In those applications of PACT, the reconstructed images can contain significant distortions and artifacts if the inhomogeneous acoustic properties of the object are not …


Sensitivity Of Mri-Guided Near-Infrared Spectroscopy Clinical Breast Exam Data And Its Impact On Diagnostic Performance, Michael A. Mastanduno, Junqing Xu, Fadi El-Ghussein, Shudong Jiang, Hong Yin, Yan Zhao, Kelly E. Michaelson, Ke Wang, Fang Ren, Brian W. Pogue, Keith D. Paulsen Aug 2014

Sensitivity Of Mri-Guided Near-Infrared Spectroscopy Clinical Breast Exam Data And Its Impact On Diagnostic Performance, Michael A. Mastanduno, Junqing Xu, Fadi El-Ghussein, Shudong Jiang, Hong Yin, Yan Zhao, Kelly E. Michaelson, Ke Wang, Fang Ren, Brian W. Pogue, Keith D. Paulsen

Dartmouth Scholarship

In this study, data from breast MRI-guided near infrared spectroscopy (NIRS) exams delivered to 44 patients scheduled for surgical resection (ending in 16 benign and 28 malignant diagnoses) were analyzed using a spatial sensitivity metric to quantify the adequacy of the optical measurements for interrogating the tumor region of interest, as derived from the concurrent MRI scan. Along with positional sensitivity, the incorporation of spectral priors and the selection of an appropriate regularization parameter in the image reconstruction were considered, and found to influence the diagnostic accuracy of the recovered images. Once optimized, the MRI/NIRS data was able to differentiate …


Design And Development Of A Miniature In Vivo Surgical Robot With Distributed Motor Control For Laparoendoscopic Single-Site Surgery, Eric J. Markvicka Aug 2014

Design And Development Of A Miniature In Vivo Surgical Robot With Distributed Motor Control For Laparoendoscopic Single-Site Surgery, Eric J. Markvicka

Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research

Paradigm shifts in invasiveness, recovery time, cosmesis, and cost have been seen within the field of general surgery through major advances in surgical technology. Some of the most advanced types of general surgery now include Minimally Invasive Surgery (MIS), LaparoEndoscopic Single-Site (LESS) surgery, and Natural Orifice Translumenal Endoscopic Surgery (NOTES). One of the newest and rapidly developing catalysts is robotic platforms. Such platforms have improved ergonomics and control, increased workspace and dexterity, and have surpassed the efficacy of many non-robotic platforms such as traditional laparoscopic surgical tools. This thesis presents the design and development of a four-degree-of-freedom (4- DOF) miniature …


Improvements To Uhmwpe, Brooke Mckelvogue Aug 2014

Improvements To Uhmwpe, Brooke Mckelvogue

Journal of Undergraduate Research at Minnesota State University, Mankato

Ultra high molecular weight polyethylene (UHMWPE) is a material used in artificial implants for articular joint replacements. However, these implants have a limited lifespan in which the patient will be pain-free due to the wear of the UHMWPE components. Recently crosslinking, or exposing the material to radiation, has been used to extend the wear resistance of UHMWPE. Crosslinking introduces another set of drawbacks; mainly the reduction of the fracture toughness of UHMWPE and the generation of free radicals, which leave the polymer vulnerable to damage from oxidation. Currently, research is being conducted on other methods to increase the wear resistance …


Computational Model Of A Left Ventricle: Showing The Effects Of Inertia On Cardiac Dyssynchrony, Andrew Mcnally, Matthew Korpela, Erin Lamke, Matthew Hudson Aug 2014

Computational Model Of A Left Ventricle: Showing The Effects Of Inertia On Cardiac Dyssynchrony, Andrew Mcnally, Matthew Korpela, Erin Lamke, Matthew Hudson

Journal of Undergraduate Research at Minnesota State University, Mankato

In an effort to research heart failure, a leading cause of death in the industrialized world, this research team has developed a segmented lumped parameter model of the left ventricle. The computations model developed focuses on dyssynchrony, a heart condition where some regions of the heart vary significantly in properties like internal muscle resistance, mass, or elastance. Inertial effects are often assumed as negligible by cardiovascular models. One primary function of this model is to investigate inertial effects as they relate to mechanical cardiac dyssynchrony. An added dimension of this analysis is to observe the thermodynamics of the cardiac cycle …


Developing A Bioreactor For Biaxial Mechanical Testing And Conditioning Of Vascular Tissue, Steve Marcous Aug 2014

Developing A Bioreactor For Biaxial Mechanical Testing And Conditioning Of Vascular Tissue, Steve Marcous

Theses and Dissertations

Cardiovascular diseases are known to be one of the major causes of death around the world. One of the major causes of cardiovascular disease is arterial malfunction. Arteries malfunction when they experience chronic perturbations in their local environment above normal levels. Hence, we developed a bioreactor system in order to study the effect of chronic changes in the arterial global parameters (axial force, luminal pressure, and flow rate) on the behavior of local parameters (circumferential stress, axial stress, and flow induced shear stress). The bioreactor system was designed to (i) perform biaxial mechanical testing, (ii) incorporate, for the first time, …