Open Access. Powered by Scholars. Published by Universities.®

Engineering Commons™

Open Access. Powered by Scholars. Published by Universities.®

Biomedical Engineering and Bioengineering

Institution
Keyword
Publication Year
Publication
Publication Type
File Type

Articles 2611 - 2640 of 11466

Full-Text Articles in Engineering

Modeling Of Temperature Swing Adsorption-Oxidation Of Volatile Organic Compounds, Busuyi O. Adebayo, Fateme Rezaei Mar 2022

Modeling Of Temperature Swing Adsorption-Oxidation Of Volatile Organic Compounds, Busuyi O. Adebayo, Fateme Rezaei

Chemical and Biochemical Engineering Faculty Research & Creative Works

In this work, we simulated a single-bed 4-step temperature swing adsorption-oxidation (TSAO) process for capture and in situ oxidation of benzene, as a model VOC, over Ni/ZrO2-SiO2, as a dual-function material (DFM). The TSAO cycles consisted of adsorption, preheating, desorption/oxidation, and cooling steps. The model sensitive parameters were estimated via parameter estimation and validated against experimental data. Extensive parametric analysis was carried out to investigate the effects of key process variables on the TSAO performance. Model results revealed relatively good prediction of the process. Under the conditions investigated, adsorption, oxidation and total removal efficiencies were estimated …


Annealing Post-Drawn Polycaprolactone (Pcl) Nanofibers Optimizes Crystallinity And Molecular Alignment And Enhances Mechanical Properties And Drug Release Profiles, M. D. Flamini, T. Lima, K. Corkum, N. J. Alvarez, Vincent Beachley Mar 2022

Annealing Post-Drawn Polycaprolactone (Pcl) Nanofibers Optimizes Crystallinity And Molecular Alignment And Enhances Mechanical Properties And Drug Release Profiles, M. D. Flamini, T. Lima, K. Corkum, N. J. Alvarez, Vincent Beachley

Henry M. Rowan College of Engineering Departmental Research

Post-drawn PCL nanofibers can be molecularly tuned to have a variety of mechanical properties and drug release profiles depending on the temperature and time of annealing, which has implications for regenerative medicine and drug delivery applications. Post-drawing polycaprolactone (PCL) nanofibers has previously been demonstrated to drastically increase their mechanical properties. Here the effects of annealing on post-drawn PCL nanofibers are characterized. It is shown that room temperature storage and in vivo temperatures increase crystallinity significantly on the order of weeks, and that high temperature annealing near melt significantly increases crystallinity and molecular orientation on the order of minutes. The kinetics …


Expanding Cherenkov Imaging Applications In Radiotherapy: Clinic-Wide In Vivo Treatment Monitoring And Mr-Linac Quality Assurance, Daniel A. Alexander Mar 2022

Expanding Cherenkov Imaging Applications In Radiotherapy: Clinic-Wide In Vivo Treatment Monitoring And Mr-Linac Quality Assurance, Daniel A. Alexander

Dartmouth College Ph.D Dissertations

Radiation therapy treatments have become increasingly complex, striving to improve patient outcomes by delivering sufficient dose for tumor control while sparing more normal tissue. This trend has necessitated the development of additional workflows, such as multilayered incident mitigation strategies and advanced techniques for adapting treatments to account for time-sensitive patient factors. Novel technologies such as optical 3D surface monitoring and magnetic resonance-guided linear accelerators have been developed to assist clinicians in implementing these workflows. We hypothesize that optical imaging methods developed for radiotherapy dose monitoring and measurement can be used to positively impact modern radiation therapy challenges. Cherenkov imaging allows …


Optimization Of The Musculoskeletal Simulation In Estimation Of Metabolic Cost, Arash Mohammadzadeh Gonabadi, Philippe Malcolm Mar 2022

Optimization Of The Musculoskeletal Simulation In Estimation Of Metabolic Cost, Arash Mohammadzadeh Gonabadi, Philippe Malcolm

UNO Student Research and Creative Activity Fair

Energy from food is supplied to the human body in the form of chemical energy in the muscles. This metabolic energy expenditure is one of the main determinants of the way we walk, and indirect calorimetry measurements are an essential tool for understanding how increases in metabolic cost restrict the mobility of clinical populations. Respiratory oxygen consumption measurements allow recording of the average metabolic cost of walking. However, the time required for these measurements prevents assessing metabolic rate in patients who cannot walk long enough. Musculoskeletal modeling techniques allow to estimate average muscle energy expenditure during locomotion in conjunction with …


Reducing Loading On The Contralateral Limb Using Human-In-The-Loop Optimization, Siena Senatore Mar 2022

Reducing Loading On The Contralateral Limb Using Human-In-The-Loop Optimization, Siena Senatore

UNO Student Research and Creative Activity Fair

In most everyday activities, we head towards a specific goal by updating our choices for a more direct path. However, there are specific clinical tasks where taking the direct path is more challenging. Clinical investigations of optimizing a prosthesis involve the assessment of multiple parameter settings through trial and error rather than goal-directed optimization. We investigate if a human-in-the-loop optimization algorithm can guide manual alterations to a prosthesis-simulating device to reduce the ground reaction force on the contralateral limb. In most participants, the optimal condition reduced the loading rate on the contralateral limb compared to the initial condition tested. These …


How Can Actuation Timing And Magnitude Of A Bilateral Semi-Rigid Hip Exoskeleton Optimize Metabolic Cost, Arash Mohammadzadeh Gonabadi, Prokopios Antonellis, Sara Myers, Iraklis Pipinos, Philippe Malcolm Mar 2022

How Can Actuation Timing And Magnitude Of A Bilateral Semi-Rigid Hip Exoskeleton Optimize Metabolic Cost, Arash Mohammadzadeh Gonabadi, Prokopios Antonellis, Sara Myers, Iraklis Pipinos, Philippe Malcolm

UNO Student Research and Creative Activity Fair

Semi-rigid exoskeletons could combine some advantages of rigid and soft approaches. The purpose of this study was to investigate the effects of timing and magnitude of assistance from a semi-rigid hip exoskeleton. For ten participants, we tested ten conditions that were combinations of 5 different end-timings, ranging from 21% to 49%, and 2 different moment magnitudes ranging from 0.06 to 0.12 Nm.kg-1. The participants walked in two reference conditions: a condition without actuation and a condition without the exoskeleton. A semi-rigid hip exoskeleton could alter metabolic rate. However, to produce a net assistive effect, it is necessary to …


Changes In Ankle Muscle Force And Power During Walking In Patients With Peripheral Artery Disease, Hafizur Rahman, Cody Anderson, Iraklis I. Pipinos, Jason M. Johanning, Jianghu Dong, Sara A. Myers Mar 2022

Changes In Ankle Muscle Force And Power During Walking In Patients With Peripheral Artery Disease, Hafizur Rahman, Cody Anderson, Iraklis I. Pipinos, Jason M. Johanning, Jianghu Dong, Sara A. Myers

UNO Student Research and Creative Activity Fair

Background: Patients with peripheral artery disease (PAD) have significantly reduced lower extremity muscle strength compared with healthy individuals as measured during isolated, single plane joint motion by isometric and isokinetic strength dynamometers. The objective of this study was to understand the contribution of the ankle muscles during walking in patients with PAD and compared to healthy older individuals.

Methods: A total of 12 patients diagnosed with Fontaine stage II PAD and 10 healthy older controls were recruited for the study. Each subject walked across a 10-meter pathway with reflective markers placed on specific anatomical locations on lower limbs while the …


Design And Development Of Software With A Graphical User Interface To Display And Convert Multiple Microscopic Histology Images, Sayed Ahmadreza Razian, Majid Jadidi, Alexey Kamenskiy Mar 2022

Design And Development Of Software With A Graphical User Interface To Display And Convert Multiple Microscopic Histology Images, Sayed Ahmadreza Razian, Majid Jadidi, Alexey Kamenskiy

UNO Student Research and Creative Activity Fair

Histological images are widely used to assess the microscopic anatomy of biological tissues. Recent advancements in image analysis allow the identification of structural features on histological sections that can help advance medical device development, brain and cancer research, drug discovery, vascular mechanobiology, and many other fields. Histological slide scanners create images in SVS and TIFF formats that were designed to archive image blocks and high-resolution textual information. Because these formats were primarily intended for storage, they are often not compatible with conventional image analysis software and require conversion before they can be used in research. We have developed a user-friendly …


Breaks In Longitudinal Elastic Fibers Of Human Femoropopliteal Arteries, Elham Zamani Mar 2022

Breaks In Longitudinal Elastic Fibers Of Human Femoropopliteal Arteries, Elham Zamani

UNO Student Research and Creative Activity Fair

Breaks in Longitudinal Elastic Fibers of Human Femoropopliteal Arteries

Elham Zamani1, Majid Jadidi1

1 Department of Biomechanics, University of Nebraska Omaha, Omaha, NE

Introduction: Elastin is a major protein in the body with half-life >50 years. It is thought that elastic fibers are formed before the postnatal period. In the femoropopliteal artery (FPA), the main artery in the leg, longitudinal elastic fibers are present in External Elastic Lamina (EEL). Our team has studied more than 1000 cadaveric human FPA and has noticed that there are big breaks in their longitudinal elastic fibers in some subjects. Our goal in this work …


Effects Of Lower Limb Cycling Training On Different Components Of Force And Fatigue In Individuals With Parkinson’S Disease, Yen-Po Lin, Rou-Shayn Chen, Vincent Chiun-Fan Chen, Chun-Hsien Liu, Hsiao-Lung Chan, Ya-Ju Chang Mar 2022

Effects Of Lower Limb Cycling Training On Different Components Of Force And Fatigue In Individuals With Parkinson’S Disease, Yen-Po Lin, Rou-Shayn Chen, Vincent Chiun-Fan Chen, Chun-Hsien Liu, Hsiao-Lung Chan, Ya-Ju Chang

Engineering Science Faculty Publications

The strength of lower extremity is important for individuals to maintain balance and ambulation functions. The previous studies showed that individuals with Parkinson’s disease suffered from fatigue and strength loss of central origin. The purpose of this study was to investigate the effect of lower extremities’ cycling training on different components of force and fatigue in individuals with Parkinson’s disease. Twenty-four individuals (13 males, 11 females, mean age: 60.58 ± 8.21 years) diagnosed with idiopathic Parkinson’s disease were randomized into training and control groups. The maximum voluntary contraction (MVC) force, voluntary activation level (VA), and twitch force of knee extensors …


Abbott Lab Instrumentation Validation, Brandon James Mukai, Bosung Josh Kim Mar 2022

Abbott Lab Instrumentation Validation, Brandon James Mukai, Bosung Josh Kim

Biomedical Engineering: Graduate Reports and Projects

Over the past 40 years, since the initial catheter ablation procedure was completed, cardiac mapping has become an essential part of electrophysiological procedures. Cardiac mapping is an electrophysiological study that allows physicians to analyze the electrical activity of the heart in order to diagnose and treat cardiovascular disease. Institutions like Cal Poly can utilize professional instrumentation systems with an appropriate wet lab to develop new devices and study various phenomena in an in-vitro physiological environment. Cardiac mapping systems used in tandem with catheter ablation procedures are essential to ensuring that the trend of deaths due to cardiovascular disease continues to …


Acl Risk Data Comparison And Turnout Analysis Of Female Dancers Trained In Ballet And Female Traditional Jumping Sport Athletes, Samantha A. Campbell Mar 2022

Acl Risk Data Comparison And Turnout Analysis Of Female Dancers Trained In Ballet And Female Traditional Jumping Sport Athletes, Samantha A. Campbell

Master's Theses

INTRODUCTION: An increase in participation in females sports has created an increase of female athletes at risk for injuring their Anterior Cruciate Ligament(ACL)[12,21,29,44]. Traditional jumping sports have the highest rate of non contact ACL injuries, due to the use of movements of cutting, pivoting and landing on one foot[5,8,32,33,38]. ACL injuries can also be attributed to neuromuscular deficits such as the ‘Ligament Dominance Theory’, ‘Quadricep Dominance Theory’, ‘Trunk Dominance Theory’ and the ‘Leg Dominance Theory’[24,33]. The neuromuscular deficits are muscle strength, power or activation patterns that can cause an individual to have an increased risk of ACL injury[33]. Female traditional …


Optimization Of A Novel Nipam-Based Thermoresponsive Copolymer For Intramuscular Injection As A Myoblast Delivery Vehicle To Combat Peripheral Artery Occlusive Disease, Quentin R. Klueter Mar 2022

Optimization Of A Novel Nipam-Based Thermoresponsive Copolymer For Intramuscular Injection As A Myoblast Delivery Vehicle To Combat Peripheral Artery Occlusive Disease, Quentin R. Klueter

Master's Theses

There is a need for a minimally invasive delivery method to enable cell therapies to combat peripheral artery occlusive disease (PAOD) in end stage patients. Myoblasts show promise as a cell mediated therapy but warrant an improved delivery method to increase cell retention in the region of interest because of their adherent nature, relative to previously used BM-MNC’s that are non-adherent. Contemporary issues with achieving successful cell therapies of vasculature can be mainly characterized by the lack of clinical translation from promising animal studies and absence of cell delivery scaffolding. Naturally, polymers have been widely experimented with as grafts to …


Impact Of Primary Myoblasts On Macrophage Polarization In-Vitro, Olivia Welch Mar 2022

Impact Of Primary Myoblasts On Macrophage Polarization In-Vitro, Olivia Welch

Master's Theses

Peripheral artery disease (PAD) is characterized by the development of atherosclerotic plaques on arterial walls, leading to the narrowing of blood vessels, resulting in ischemia in the downstream tissue. In the United States, 12% of the adult population is affected by PAD and its related symptoms. Current surgical revascularization techniques can be effective in part of the patient population, but there is a need for other options. Alternatively, collateral blood vessels, or natural bypass arteries, enlarge to increase blood flow to the ischemic tissue in a process called arteriogenesis, which has been studied as a therapeutic option. Cell-based therapies, such …


Bimodal Particle Distributions With Increased Thermal Conductivity For Solid Particles As Heat Transfer Media And Storage Materials, Chase E. Christen, Jesús Gómez-Hernández, Todd P. Otanicar Mar 2022

Bimodal Particle Distributions With Increased Thermal Conductivity For Solid Particles As Heat Transfer Media And Storage Materials, Chase E. Christen, Jesús Gómez-Hernández, Todd P. Otanicar

Mechanical and Biomedical Engineering Faculty Publications and Presentations

Solid particles are being considered in several high temperature thermal energy storage systems and as heat transfer media in a variety of advanced power generation systems, particularly in concentrated solar power plants. The downside of such an approach is the low overall heat transfer coefficients caused by the inherently low thermal conductivity values of the low-cost solid media when coupled to heat exchanger for the power cycle working fluid. Choosing the right particle size distribution, emittance, and material of the solid media can all make a substantial difference in packed bed thermal conductivity. Current research though exclusively focuses on continuous …


Formulation And Processing Of Dual Functional Adsorbent/Catalyst Structured Monoliths Using An Additively Manufactured Contactor For Direct Capture/Conversion Of Co2 With Cogeneration Of Ethylene, Shane Lawson, Khaled Baamran, Kyle Newport, Fateme Rezaei, Ali A. Rownaghi Mar 2022

Formulation And Processing Of Dual Functional Adsorbent/Catalyst Structured Monoliths Using An Additively Manufactured Contactor For Direct Capture/Conversion Of Co2 With Cogeneration Of Ethylene, Shane Lawson, Khaled Baamran, Kyle Newport, Fateme Rezaei, Ali A. Rownaghi

Chemical and Biochemical Engineering Faculty Research & Creative Works

Utilizing CO2 as a mild oxidant for oxidative dehydrogenation of ethane (ODHE) is an attractive way of recycling this greenhouse contaminant. Typically, CO2 capture and conversion processes are performed in separate beds, however, combining these processes into one bed incurs advantages of lower thermal gradient and reduced energy costs. This study formulated the first generation of structured dual-functional materials (DFMs) by directly 3D printing metal-oxide-CaO/ZSM-5 inks into monolithic contactors. Specifically, we 3D-printed monoliths with V, Ga, Ni, or Ti dopants to perform metal screening and determine which metal generates the best structured DFM for combined CO2 capture …


Youth Pitching Kinematics: Associations With Body Overweight Parameters, Christina K. Fong Mar 2022

Youth Pitching Kinematics: Associations With Body Overweight Parameters, Christina K. Fong

Master's Theses

The objective of this study was to investigate associations between injury-related kinematic parameters and overweight measures for youth baseball pitchers. The injury-related kinematic parameters considered were measurements 1) at foot contact: stride length, front foot position, shoulder external rotation, shoulder abduction, and elbow flexion; 2) between FC and ball release: peak knee extension; and 3) at BR: shoulder abduction. Data from three separate collection sites examined pitching mechanics of 18 10- to 11-year-old pitchers, 11 14- to 16-year-old pitchers, and 104 16- to 18-year-old pitchers Linear regression analyses were performed to determine significant correlations between kinematic parameters and body mass …


Bone And Cartilage Compression Simulator, Karoline M. Wucherer, Benjamin A. Parmentier, Thomasina E. Hinkle Mar 2022

Bone And Cartilage Compression Simulator, Karoline M. Wucherer, Benjamin A. Parmentier, Thomasina E. Hinkle

Biomedical Engineering

A device was developed that delivers mechanical loads to bone and soft tissue samples under physiological conditions to aid in the research of tissue engineering bone and cartilage. To begin the design process, a Network Diagram and Gantt Chart were produced to create a general timeline for the project to follow. This allowed us to measure our progress and determine what effects (if any) delays could have on our project.


Live Cell Imaging Gas Control, Elsa M. Bean, Brady C. Berg, Abby A. Jens Mar 2022

Live Cell Imaging Gas Control, Elsa M. Bean, Brady C. Berg, Abby A. Jens

Biomedical Engineering

The following document outlines the entire process for designing and manufacturing a Live Cell Imaging Gas Control subsystem in tandem with the Heated Stage subsystem to make a CO2 and temperature-controlled chamber for use with the Olympus IX73P2F Microscope. It highlights the current literature and patents surrounding live cell imaging and touches on the existing live cell imaging setups currently being used by other entities. Following this, it defines the scope of the project, key customer requirements, and engineering specifications to ensure the design meets all the needs of its users. This document includes project planning steps to establish …


Live Cell Imaging Heated Stage, Kerri Byrne, Anna Frauenheim, Simon Park Mar 2022

Live Cell Imaging Heated Stage, Kerri Byrne, Anna Frauenheim, Simon Park

Biomedical Engineering

Live cell imaging is a method used by scientists to obtain a better understanding of tissue and cell functions through the study and imaging of cellular dynamics, however it is often detrimental to cell cultures due to effects of changing environment on dynamic cellular events. In order to combat the effects of a changing environment, our team has designed, manufactured, and tested an incubation chamber that will control the heat and pH environment that these cells are experiencing throughout the imaging process. This project is sponsored by the BMED microscopy core group to be used with the Olympus IX73P2F inverted …


Minivette Integrated Sample Prep Funnel For Cepheid Cartridges, Hanna N. Blumer, Sophia Arias, Camille Porciuncula, Ben Runkle Mar 2022

Minivette Integrated Sample Prep Funnel For Cepheid Cartridges, Hanna N. Blumer, Sophia Arias, Camille Porciuncula, Ben Runkle

Biomedical Engineering

This report covers the redesign of the Sample Prep Funnel for Cepheid’s engineering team. The Sample Prep Funnel, responsible for relaying liquid from the sample collection device to the testing cartridge, experiences fluid loss that causes invalid test results. Our group's task was to redesign this funnel to minimize fluid loss and, overall, increase efficiency and effectiveness.


Pickleball Paddle For Minimizing Elbow/Shoulder Joint Forces, Kaley Sapper, Nick Rodgers, Claire Steines Mar 2022

Pickleball Paddle For Minimizing Elbow/Shoulder Joint Forces, Kaley Sapper, Nick Rodgers, Claire Steines

Biomedical Engineering

The goal of this project was to design a pickleball paddle to prevent overuse injuries. This was accomplished through a design that minimizes joint forces experienced by the player during backhand strokes.


Gradient And Pressure Recovery Of A Self-Expandable Transcatheter Aortic Valve Depends On Ascending Aorta Size: In Vitro Study, Milad Samaee, Hoda Hatoum, Michael Biersmith, Breandan Yeats, Shelley C. Gooden, Vinod H. Thourani, Rebecca T. Hahn, Scott Lilly, Ajit Yoganathan, Lakshmi Prasad Dasi Mar 2022

Gradient And Pressure Recovery Of A Self-Expandable Transcatheter Aortic Valve Depends On Ascending Aorta Size: In Vitro Study, Milad Samaee, Hoda Hatoum, Michael Biersmith, Breandan Yeats, Shelley C. Gooden, Vinod H. Thourani, Rebecca T. Hahn, Scott Lilly, Ajit Yoganathan, Lakshmi Prasad Dasi

Michigan Tech Publications, Part 1

Objective: In this study we aimed to understand the role of interaction of the Medtronic Evolut R transcatheter aortic valve with the ascending aorta (AA) by evaluating the performance of the valve and the pressure recovery in different AA diameters with the same aortic annulus size. Methods: A 26-mm Medtronic Evolut R valve was tested using a left heart simulator in aortic root models of different AA diameter (D): small (D = 23 mm), medium (D = 28 mm), and large (D = 34 mm) under physiological conditions. Measurements of pressure from upstream to downstream of the valve were performed …


Feverdots, Kameryn Laureano, Heidi Silk, Rita Grigorian Mar 2022

Feverdots, Kameryn Laureano, Heidi Silk, Rita Grigorian

Biomedical Engineering

FeverDots are wearable temperature sensitive stickers that change color from black to pink at 99°F when placed on the temple or forehead. The objective of this project was to develop an efficient manufacturing method for FeverDots, and manufacture a device along with it. To create the FeverDots manufacturing device, the full design process was executed. The team went through a thorough ideation phase before ultimately defining and specifying the scope of the project.

The key customer requirements of this device include that it is lightweight, portable, durable, simple to assemble, easy to use, and able to generate uniform ink and …


Astm Test Fixture For Spinal Screws, Sarah K. Pickering, Matthew W. Rowen, Kaajal N. Khanna, Thomas A. Sunding Mar 2022

Astm Test Fixture For Spinal Screws, Sarah K. Pickering, Matthew W. Rowen, Kaajal N. Khanna, Thomas A. Sunding

Biomedical Engineering

This document is an overview report of the Cal Poly Senior Project ASTM Test Fixture for SeaSpine orthopedic bone screws. The main application of orthopedic screws is to fasten implants directly to the bone structure, enhancing structural integrity. Testing for breaking angle, insertion torque, removal torque, axial pullout strength, and self-tapping force as specified in the ASTM F543 Annexes provides the FDA with vital screw mechanics and ensures manufacturing uniformity. The test system is comprised of custom and off the shelf components allowing for interchangeability, in case of part failure, and a low overall cost. It is mechanically capable of …


Eeg And Fmri Coupling And Decoupling Based On Joint Independent Component Analysis (Jica), Nicholas Heugel, Scott A. Beardsley, Einat Liebenthal Mar 2022

Eeg And Fmri Coupling And Decoupling Based On Joint Independent Component Analysis (Jica), Nicholas Heugel, Scott A. Beardsley, Einat Liebenthal

Biomedical Engineering Faculty Research and Publications

Background

Meaningful integration of functional magnetic resonance imaging (fMRI) and electroencephalography (EEG) requires knowing whether these measurements reflect the activity of the same neural sources, i.e., estimating the degree of coupling and decoupling between the neuroimaging modalities.

New method

This paper proposes a method to quantify the coupling and decoupling of fMRI and EEG signals based on the mixing matrix produced by joint independent component analysis (jICA). The method is termed fMRI/EEG-jICA.

Results

fMRI and EEG acquired during a syllable detection task with variable syllable presentation rates (0.25–3 Hz) were separated with jICA into two spatiotemporally distinct components, a primary …


Cbct In Clinical Practice, Tarunjeet Pabla Bds, Dmd, Ms, Dip. Abomr, Hugo C. Campos Dds, Dmd, Mds, Dip. Abomr, Aruna Ramesh Bds, Dmd, Ms, Dip. Abomr Mar 2022

Cbct In Clinical Practice, Tarunjeet Pabla Bds, Dmd, Ms, Dip. Abomr, Hugo C. Campos Dds, Dmd, Mds, Dip. Abomr, Aruna Ramesh Bds, Dmd, Ms, Dip. Abomr

The Journal of the Michigan Dental Association

This feature explores the integration of Cone Beam Computed Tomography (CBCT) into dental practice, offering guidelines for best practices. Introduced in 2001, CBCT revolutionized dental radiography, impacting various clinical areas. The article emphasizes the need for clinicians to comprehend CBCT technology, its benefits, and potential risks. It delves into CBCT imaging considerations, technical parameters (Field of View, Voxel Size, Spatial and Contrast Resolution), image viewing, artifacts, machine calibration, and service. Addressing radiation dose, risks, and protection, the article outlines decision-making for 2D vs. 3D imaging. It underscores the responsibility of interpreting CBCT images, legal considerations, return on investment, and the …


Targeting Hif-2Α In The Tumor Microenvironment: Redefining The Role Of Hif-2Α For Solid Cancer Therapy., Leah Davis, Matthias Recktenwald, Evan Hutt, Schuyler Fuller, Madison Briggs, Arnav Goel, Nichole Daringer Feb 2022

Targeting Hif-2Α In The Tumor Microenvironment: Redefining The Role Of Hif-2Α For Solid Cancer Therapy., Leah Davis, Matthias Recktenwald, Evan Hutt, Schuyler Fuller, Madison Briggs, Arnav Goel, Nichole Daringer

Henry M. Rowan College of Engineering Departmental Research

Inadequate oxygen supply, or hypoxia, is characteristic of the tumor microenvironment and correlates with poor prognosis and therapeutic resistance. Hypoxia leads to the activation of the hypoxia-inducible factor (HIF) signaling pathway and stabilization of the HIF-α subunit, driving tumor progression. The homologous alpha subunits, HIF-1α and HIF-2α, are responsible for mediating the transcription of a multitude of critical proteins that control proliferation, angiogenic signaling, metastasis, and other oncogenic factors, both differentially and sequentially regulating the hypoxic response. Post-translational modifications of HIF play a central role in its behavior as a mediator of transcription, as well as the temporal transition from …


Advancing Ubiquitous Collaboration For Telehealth - A Framework To Evaluate Technology-Mediated Collaborative Workflow For Telehealth, Hypertension Exam Workflow Study, Christopher Bondy Ph.D., Linlin Chen Ph.D, Pamela Grover Md, Pengcheng Shi Ph.D Feb 2022

Advancing Ubiquitous Collaboration For Telehealth - A Framework To Evaluate Technology-Mediated Collaborative Workflow For Telehealth, Hypertension Exam Workflow Study, Christopher Bondy Ph.D., Linlin Chen Ph.D, Pamela Grover Md, Pengcheng Shi Ph.D

Articles

Healthcare systems are under siege globally regarding technology adoption; the recent pandemic has only magnified the issues. Providers and patients alike look to new enabling technologies to establish real-time connectivity and capability for a growing range of remote telehealth solutions. The migration to new technology is not as seamless as clinicians and patients would like since the new workflows pose new responsibilities and barriers to adoption across the telehealth ecosystem. Technology-mediated workflows (integrated software and personal medical devices) are increasingly important in patient-centered healthcare; software-intense systems will become integral in prescribed treatment plans [1]. My research explored the path to …


Novel Stimuli-Responsive Pectin-Pvp-Functionalized Clay Based Smart Hydrogels For Drug Delivery And Controlled Release Application, Shabnam Rehmat, Nayab Batool Rizvi, Saba Urooge Khan, Abdul Ghaffar, Atif Islam, Rafi Ullah Khan, Azra Mehmood, Hira Butt, Muhammad Rizwan Feb 2022

Novel Stimuli-Responsive Pectin-Pvp-Functionalized Clay Based Smart Hydrogels For Drug Delivery And Controlled Release Application, Shabnam Rehmat, Nayab Batool Rizvi, Saba Urooge Khan, Abdul Ghaffar, Atif Islam, Rafi Ullah Khan, Azra Mehmood, Hira Butt, Muhammad Rizwan

Michigan Tech Publications, Part 1

Stimuli-responsive drug delivery systems are urgently required for injectable site-specific delivery and release of drugs in a controlled manner. For this purpose, we developed novel pH-sensitive, biodegradable, and antimicrobial hydrogels from bio-macromolecule pectin, polyvinylpyrrolidone (PVP), 3-aminopropyl (diethoxy)methyl silane (3-APDEMS), and sepiolite clay via blending and solution casting technique. The purified sepiolite (40 um) was functionalized with 3-APDEMS crosslinker (ex-situ modification) followed by hydrogels fabrication. FTIR and SEM confirmed crosslinked structural integrity and rod-like morphology of hydrogels respectively. The swelling properties of hydrogels could be controlled by varying the concentration of modified clay in pectin/PVP blends. Moreover, the decrease in pH …