Open Access. Powered by Scholars. Published by Universities.®
- Discipline
-
- Life Sciences (8515)
- Biology (2708)
- Physical Sciences and Mathematics (2396)
- Ecology and Evolutionary Biology (1587)
- Environmental Sciences (1474)
-
- Engineering (1339)
- Social and Behavioral Sciences (1147)
- Animal Sciences (1109)
- Plant Sciences (1029)
- Agriculture (736)
- Earth Sciences (606)
- Forest Sciences (568)
- Education (501)
- Civil and Environmental Engineering (493)
- Biomedical Engineering and Bioengineering (421)
- Psychology (386)
- Genetics and Genomics (381)
- Food Science (337)
- Entomology (323)
- Water Resource Management (309)
- Medicine and Health Sciences (292)
- Chemistry (281)
- Biological Engineering (263)
- Biochemistry, Biophysics, and Structural Biology (251)
- Nutrition (212)
- Sociology (202)
- Arts and Humanities (201)
- Biochemistry (176)
- Natural Resources and Conservation (152)
- Dairy Science (142)
- Keyword
-
- Utah State University (597)
- Utah (454)
- Newspaper (404)
- USU (398)
- The Utah Statesman (371)
-
- Statesman (367)
- Scanning electron microscopy (342)
- Agenda (264)
- Utah State University Extension (240)
- Educational Policies Committee (209)
- Human–wildlife conflicts (196)
- Faculty senate (192)
- Management (165)
- USU Extension (155)
- Minutes (146)
- Climate change (137)
- Curriculum Subcommittee (129)
- UWRL (116)
- Agriculture (114)
- Water (101)
- Transmission electron microscopy (96)
- X-ray microanalysis (96)
- Conservation (89)
- Ecology (80)
- Irrigation (80)
- Commencement (78)
- Environmental (77)
- Usu (77)
- Human-wildlife interactions (76)
- April (75)
- Publication Year
- Publication
-
- All Graduate Theses and Dissertations, Spring 1920 to Summer 2023 (3266)
- Scanning Microscopy (1289)
- Biology (697)
- Human–Wildlife Interactions (688)
- Wildlife Damage Management Conference (478)
-
- All Current Publications (464)
- The Utah Statesman (417)
- Wildland Resources Faculty Publications (416)
- Aspen Bibliography (408)
- All Graduate Theses and Dissertations, Fall 2023 to Present (340)
- Scanning Electron Microscopy (338)
- Educational Policies Committee (329)
- Memorandum (315)
- All Graduate Plan B and other Reports, Spring 1920 to Spring 2023 (303)
- Biology Faculty Publications (299)
- Undergraduate Honors Capstone Projects (293)
- Student Research Symposium (245)
- Reports (195)
- Biology Posters (190)
- Watershed Sciences Faculty Publications (186)
- Chemistry and Biochemistry Faculty Publications (172)
- Small Satellite Conference (171)
- All U.S. Government Documents (Utah Regional Depository) (165)
- Food Structure (161)
- Civil and Environmental Engineering Faculty Publications (158)
- Cells and Materials (148)
- Faculty Senate & Faculty Senate Executive Committee (145)
- Natural Resources and Environmental Issues (139)
- College of Engineering News (127)
- Utah Science (122)
- Publication Type
- File Type
Articles 10651 - 10680 of 16018
Full-Text Articles in Entire DC Network
Ultrastructural Changes Of The Vestibular Sensory Organs After Streptomycin Application On The Lateral Canal, Kwang-Sun Lee, Robert S. Kimura
Ultrastructural Changes Of The Vestibular Sensory Organs After Streptomycin Application On The Lateral Canal, Kwang-Sun Lee, Robert S. Kimura
Scanning Microscopy
Early changes in the vestibular sense organs resulting from the application of a streptomycin sulfate soaked Gelfoam® pledget on the fenestra of the lateral semicircular canal were studied by transmission and scanning electron microscopy. Three days after the application, lesions were present in the central part of the lateral crista. The type I sensory cells were more affected than the type JI cells. These sensory cells showed mitochondrial swelling, cytoplasm protrusion at the cell apex, inclusion of multiple vacuoles, fusion or loss of stereocilia, and pyknotic nuclei. Seven days after the drug application, the sensory cell damage extended to all …
Light Element X-Ray Microanalysis In Biology, A. T. Marshall
Light Element X-Ray Microanalysis In Biology, A. T. Marshall
Scanning Microscopy
It is shown that both qualitative and quantitative light element X-ray microanalysis of biological samples is feasible. These analyses were carried out using ultrathin window (UTW) detectors. Quantitative analysis yields a total element analysis with H estimated by difference or "guesstimated". Comparison with calculated concentrations, or concentrations obtained by chemical analysis, shows that X-ray microanalysis of sections, by the peak to continuum ratio model, give sufficiently accurate results for biological purposes.
The measurement of O concentrations to yield water content is carried out using x-ray imaging techniques, so that the distribution of heavier elements can be spatially related to water …
Effect Of Urinary Macromolecules And Chondroitin Sulphate On Calcium Oxalate Crystallization In Urine, A. L. Rodgers, D. Ball, W. Harper
Effect Of Urinary Macromolecules And Chondroitin Sulphate On Calcium Oxalate Crystallization In Urine, A. L. Rodgers, D. Ball, W. Harper
Scanning Microscopy
After filtration and ultrafiltration (10 kD) of 24 hour urine specimens from 12 healthy male subjects, calcium oxalate crystallization was induced in the filtered (FILTD) and ultrafiltered (UF) fractions by administration of a sodium oxalate load. In addition crystallization was also induced in UF fractions to which physiological quantities of chondroitin sulphate (CHON) had been added (UF + CHON). The rate of calcium oxalate crystallization was determined by measuring the rate at which turbidity increased. Crystal numbers and sizes were measured with a Malvern particle size analyzer and by scanning electron microscopy.
Crystallization rates, crystal numbers and crystal sizes were …
Improvements In Biological X-Ray Microanalysis: Cryoembedding For Specimen Preparation And Multivariate Statistical Analysis For Data Interpretation, C. Quintana, N. Bonnet
Improvements In Biological X-Ray Microanalysis: Cryoembedding For Specimen Preparation And Multivariate Statistical Analysis For Data Interpretation, C. Quintana, N. Bonnet
Scanning Microscopy
For biological X-ray microanalysis, cryoembedding (CE) combined with cryofixation (CF) and cryodehydration (CD) was already proposed as an alternative method to freeze-dried cryosections in 1984 by Wroblewski and Wroblewski. CD by freeze-drying (FD) is usually recommended because it provides better retention of diffusible elements. CD by freeze-substitution (FS) has the advantage of being simpler, giving more reproducible preservation of ultrastructure and causing fewer problems for resin infiltration. We have increased the retention of diffusible elements by using home-made devices for CS and CE in the new Lowicryl KllM and HM23 resins. These resins allow samples to be kept at a …
Critical Point Mounting Of Kinetoplast Dna For Atomic Force Microscopy, T. Thundat, R. J. Warmack, D. P. Allison, K. B. Jacobson
Critical Point Mounting Of Kinetoplast Dna For Atomic Force Microscopy, T. Thundat, R. J. Warmack, D. P. Allison, K. B. Jacobson
Scanning Microscopy
Atomic force microscope (AFM) images of intact kinetoplast DNA were obtained from samples prepared utilizing critical point drying. These images are compared with AFM images obtained using conventional methods for DNA deposition. Although the images obtained on chemically pretreated mica show more details than on unmodified mica, images obtained with critical point drying were superior. Kinetoplast networks with expected sizes and structures were routinely observed with critical point drying. The resolution of individual strands of DNA was greatly improved, and image artifacts associated with air dried samples were eliminated. Samples prepared using mildly sonicated kinetoplast DNA show isolated minicircles.
Signal And Image Manipulation In Microanalysis, P. W. Hawkes
Signal And Image Manipulation In Microanalysis, P. W. Hawkes
Scanning Microscopy
Scanning electron microscopes, and transmission instruments equipped for EELS, generate a host of signals and hence of images from each pixel of the specimen. Numerous ingenious ways of coping with this multiplicity of information, which may be very different in character, have been devised, but no detailed study has yet been made of the appropriate mathematical structure, with the aid of which all this information could be manipulated reasonably easily.
One such structure falls within the subject that has come to be known as Image Algebra, the principal attraction of which is that we deal directly with entire images …
Standards For X-Ray Microanalysis Of Calcified Structures, J. A. Lopez-Escamez, A. Campos
Standards For X-Ray Microanalysis Of Calcified Structures, J. A. Lopez-Escamez, A. Campos
Scanning Microscopy
The ability of electron probe X-ray microanalysis (EPMA) to solve biological problems often depends on the use of a quantitative approach. EPMA allows the quantitative determination of chemical elements of biological materials by using reference standards which resemble the specimen in the mode of interaction with the electron beam. Although there is a large experience in the quantification of elements in biological thin specimens, experience with standards for X-ray microanalysis of bulk specimens is limited, especially for calcified structures where the density of the specimen is difficult to estimate. The quality of the results in EPMA depends on obtaining accurate …
Environmental Scanning Electron Microscope Examination Of Paper In High Moisture Environment: Surface Structural Changes And Electron Beam Damage, Päivi Forsberg, Pierre Lepoutre
Environmental Scanning Electron Microscope Examination Of Paper In High Moisture Environment: Surface Structural Changes And Electron Beam Damage, Päivi Forsberg, Pierre Lepoutre
Scanning Microscopy
Supercalendered and coated papers (SC and LWC) were examined using an environmental scanning electron microscope (ESEM). Moderate structural surface changes were observed as water condensed on the surface in a high moisture environment. The changes were fully or partially reversible depending on the sample origin. A wide range of contact angles could be observed when condensing water on uncoated wood fibers. While there was no visible indication of irradiation damage on the commercial paper samples examined nor on mechanical pulp fibers, attempts to look at chemical pulp fibers during wetting to examine fiber swelling were unsuccessful because of very rapid …
X-Ray Microanalysis Of Endocrine, Exocrine And Intestinal Cells And Organs In Culture: Technical And Physiological Aspects, Romuald Wróblewski, Joanna Wroblewski
X-Ray Microanalysis Of Endocrine, Exocrine And Intestinal Cells And Organs In Culture: Technical And Physiological Aspects, Romuald Wróblewski, Joanna Wroblewski
Scanning Microscopy
In the present study methods for preparation of cultured cells and organ cultures for analytical electron microscopy are investigated. These methods allow qualitative and quantitative analysis of mobile ions in combination with biochemical or morphological studies. Cultured cells can be easily prepared for analytical microscopy and therefore use of in vitro systems for X-ray microanalysis has increased over the last few years. Two major, anhydrous preparation techniques, by which loss or redistribution of ions is minimized, were used: (1) Cells were cryosectioned and analysis carried out on freeze-dried sections obtained from frozen cell monolayers, pelleted cells or organ cultures. (2) …
Microvascular Pattern Of The Retina In The Japanese Monkey (Macaca Fuscata Fuscata), Shigenori Okada, Yoshikuni Ohta
Microvascular Pattern Of The Retina In The Japanese Monkey (Macaca Fuscata Fuscata), Shigenori Okada, Yoshikuni Ohta
Scanning Microscopy
The microvascular architecture of the retina in the Japanese monkey was revealed using scanning electron microscopy of microvascular corrosion casts.
At the optic nerve disc, the central retinal artery radiated to four primary retinal arterioles: the superior and inferior temporal arterioles and superior and inferior nasal arterioles. A dense retinal capillary network showed regional differences in density. The capillary networks observed were divided in four parts: the optic nerve disc, macula, equator, and ora serrata. At the optic nerve disc, the network was a multi-laminar structure containing the radial peripapillary capillaries in parallel with the nerve fibers at the innermost …
1st Biennial Ultra-High Temperature (Uht) Symposium, Various Authors
1st Biennial Ultra-High Temperature (Uht) Symposium, Various Authors
Other Documents
No abstract provided.
Plasmon Effects In The Particle-Induced Kinetic Electron Emission From Solids, Max Rösler
Plasmon Effects In The Particle-Induced Kinetic Electron Emission From Solids, Max Rösler
Scanning Microscopy
Starting from a microscopic description of the particle-induced kinetic electron emission based on the transport equation formalism, the role of different excitation and scattering mechanisms is investigated. Especially, the excitation of electrons by decay of plasmons generated by the impinging particle results in an important contribution to the electron yield. In the case of ion-induced kinetic electron emission, the special features of the energy distribution of emitted electrons are related to the plasmon damping and the plasmon dispersion. In order to describe the available experimental results on nearly-free-electron metals (Al,Mg) in a consistent way, plasmon effects must be taken into …
Induction Of Selective Inner Hair Cell Damage By Carboplatin, S. Takeno, R. V. Harrison, R. J. Mount, M. Wake, Y. Harada
Induction Of Selective Inner Hair Cell Damage By Carboplatin, S. Takeno, R. V. Harrison, R. J. Mount, M. Wake, Y. Harada
Scanning Microscopy
Carboplatin (diammine [1,1 cyclobutane dicarboxylato (2)-0,0'] platinum) is an anti-cancer agent which can be toxic to the inner ear. We have explored the nature of this ototoxicity in the chinchilla. In this species, initial degenerative changes appear to be restricted to the inner hair cell (IHC) regions of the organ of Corti. This finding is intriguing and unusual since all other known ototoxic drugs, such as aminoglycosides, are predominantly associated with outer hair cell damage.
In the present study, the mechanism of ototoxicity was investigated by comparing two different routes of carboplatin administration. Carboplatin was administered either intravenously (i.v.) or …
Integrated Embedding Optimization Applied To Salt Lake Valley Aquifers, A. Gharbi, Richard C. Peralta
Integrated Embedding Optimization Applied To Salt Lake Valley Aquifers, A. Gharbi, Richard C. Peralta
Civil and Environmental Engineering Faculty Publications
The embedding optimization modeling approach is adapted to aid sustainable groundwater quantity and quality management of complex nonlinear multilayer aquifers. Implicit block-centered finite difference approximations of the quasi three-dimensional unsteady flow equation and Galerkin finite element approximations of the two-dimensional advection-dispersion transport equation are embedded directly as constraints in the model. Also used are nonlinear constraints describing river-aquifer interflow, evapotranspiration, and vertical flow reduction due to unconfinement. These circumvent use of large numbers of integer variables. The use of both linear and nonlinear formulations in a cyclical manner reduces execution time and improves confidence in solution optimality. The methodology is …
Optimal Freeze-Drying Of Cryosections And Bulk Specimens For X-Ray Microanalysis, L. Edelmann
Optimal Freeze-Drying Of Cryosections And Bulk Specimens For X-Ray Microanalysis, L. Edelmann
Scanning Microscopy
Electron microscopic investigations of rapidly frozen specimens of striated muscle, either frozen-hydrated or obtained after different dehydration procedures, have shown that the subcellular distribution of the main cellular cation K+ or its surrogates Rb+, Cs+, or Tl+ does not follow the water distribution but follows certain proteins. Conflicting results obtained by X-ray microanalysis of freeze-dried cryosections are explained by showing that freeze-drying of bulk specimens and cryosections must be carried out for rather long periods at low temperature in order to avoid severe shrinkage and ion redistribution artefacts. Proposals for future freeze-drying studies are …
Ultrastructural Alterations Of Golgi Apparatus In The Nerve Cells Of Cerebral Cortex In Human Hydrocephalus. A Qualitative Study Using Cortical Biopsies, Orlando J. Castejon, Melecio Diaz, Consuelo Valero
Ultrastructural Alterations Of Golgi Apparatus In The Nerve Cells Of Cerebral Cortex In Human Hydrocephalus. A Qualitative Study Using Cortical Biopsies, Orlando J. Castejon, Melecio Diaz, Consuelo Valero
Scanning Microscopy
Cortical biopsies of 17 patients with clinical diagnosis of hydrocephalus and associated pathology were examined in the transmission electron microscope. Moderately and severely edematous neurons showed relevant structural changes of the Golgi apparatus consisting of either discrete or marked dilation, fragmentation, and partial disappearance of Golgi stacked cisternae. In Arnold-Chiari malformation small Golgi complexes of vesicular type and atrophic changes were observed in severely edematous neurons. The microtubules appeared intact, suggesting differential response between Golgi complex and microtubules. Atrophic changes of the Golgi complex coexisted with degenerated presynaptic endings.
Ultrastructural Observations Of The Argonaut Shell, P. R. Mitchell, P. P. Phakey, W. A. Rachinger
Ultrastructural Observations Of The Argonaut Shell, P. R. Mitchell, P. P. Phakey, W. A. Rachinger
Scanning Microscopy
An examination of the ultrastructure of the shell of the cephalopod Argonauta Nodosa was carried out using scanning electron microscopy, transmission electron microscopy and polarised light microscopy. The structure of the Argonaut shell was found to consist of an inner and outer prismatic layer separated by a thin central zone which was sparsely occupied by spherulitic crystals. Fluctuations in the width and porosity of the central zone resulted in changes in the shell's opacity and gave rise to the fibrous lines visible in the structure. The central zone was the region of initial growth and was the nucleating point for …
Pc Software For Optimizing Groundwater Contaminant Plume Capture And Containment, Richard C. Peralta, Herminio H. Suguino, Alaa H. Aly
Pc Software For Optimizing Groundwater Contaminant Plume Capture And Containment, Richard C. Peralta, Herminio H. Suguino, Alaa H. Aly
Civil and Environmental Engineering Faculty Publications
Simulation/optimization (S/0) models can be used to speed the process of computing desirable groundwater pumping strategies for plume management. They make the process of computing optimal strategies fairly straightforward and can help minimize the labor and cost of groundwater contaminant cleanup.
Biological Electron Energy Loss Spectroscopy In The Field-Emission Scanning Transmission Electron Microscope, R. D. Leapman, S. Q. Sun, J. A. Hunt, S. B. Andrews
Biological Electron Energy Loss Spectroscopy In The Field-Emission Scanning Transmission Electron Microscope, R. D. Leapman, S. Q. Sun, J. A. Hunt, S. B. Andrews
Scanning Microscopy
The dedicated scanning transmission electron microscope (STEM) combined with parallel electron energy loss spectroscopy (EELS) provides a very sensitive means of detecting specific elements in small structures. EELS is more sensitive than optimized energy-dispersive X-ray spectroscopy by a factor of about three for calcium. Measurement of such low concentrations requires special processing methods such as difference-acquisition techniques and multiple least squares procedures for fitting reference spectra. By analyzing data recorded at each pixel in a spectrum-image it is possible to map quantitatively the elemental distributions in a specimen. It is possible to prepare cryosections that are sufficiently thin to avoid …
Electron Probe X-Ray Microanalysis Of Epithelial Cells: Aspects Of Cryofixation, Karl Zierold, Hartmut Hentschel, Frank Wehner, Armin Wessing
Electron Probe X-Ray Microanalysis Of Epithelial Cells: Aspects Of Cryofixation, Karl Zierold, Hartmut Hentschel, Frank Wehner, Armin Wessing
Scanning Microscopy
Content and distribution of diffusible ions in epithelial cells were studied by scanning transmission electron microscopy and energy dispersive electron probe X-ray microanalysis of freeze-dried cryosections from trout kidney, rat liver and Malpighian tubules of Drosophila larvae. Cryofixation of small excised kidney and liver samples by rapid immersion into liquid propane resulted in intracellular K/Na-ratios < 1. In contrast, K/Na-ratios > 7 were obtained after in situ cryofixation by means of a cryopunching device which allows tissue pieces to be frozen during excision from the intact organ. Isolated hepatocytes cryofixed in a small droplet of culture medium had a K/Na-ratio of 3.7. After culturing the hepatocytes, …
Radiation-Induced Fibrosis: The Structure/Function Relationship, J. C. Murray
Radiation-Induced Fibrosis: The Structure/Function Relationship, J. C. Murray
Scanning Microscopy
Fibrosis is a frequent complication of therapeutic radiation delivered to organ sites such as the thorax and pelvic region. We investigated the relationship between function, and biochemical and structural changes in the lung and colon of CBA mice irradiated with 240 kV X-rays. Progressive changes in lung function, as evidenced by increased breathing rates were observed out to 6 months post-irradiation. Biochemical studies demonstrated increased metabolism (synthesis and breakdown) of collagen around 6 months after irradiation, but provided no evidence of net collagen accumulation. Analysis of collagen isotypes revealed a slight increase in the ratio of types I and Ill. …
Impacts Of Projected Climate Change On Urban Water Use, United States Department Of The Interior, Bureau Of Reclamation
Impacts Of Projected Climate Change On Urban Water Use, United States Department Of The Interior, Bureau Of Reclamation
Water
Urban water use, particularly outdoor use, responds to changes in temperature, precipitation, and other climatic parameters. This study significantly improved the capacity of an existing regional water demand model to estimate the response of both residential and commercial-industrial water demand to changes in climatic parameters. The resulting functional relationships derived from historic time-series climatic and water use data were applied to global climate scenarios for the four Wasatch Front counties of Utah.
Image-Eels: A Synthesis Of Energy-Loss Analysis And Imaging, Karl-Heinz Körtje
Image-Eels: A Synthesis Of Energy-Loss Analysis And Imaging, Karl-Heinz Körtje
Scanning Microscopy
Two different modes of energy-filtering transmission electron microscopy (EFTEM) are often used for element microanalysis: electron energy-loss spectroscopy (EELS) and electron spectroscopic imaging (ESI).
A new approach was developed which we call Image-EELS. This procedure was realized with the commercially available standard equipment of the energy-filtering transmission microscope CEM 902 (Zeiss, Germany).
A series of energy-filtered images is recorded with ESI at many different energy losses. In a second step the intensity of selected objects is measured for each energy loss and plotted as a function of the energy loss, that means as an EELS spectrum.
This method increases the …
Optical Methods For Imaging Ionic Activities, Roger B. Moreton
Optical Methods For Imaging Ionic Activities, Roger B. Moreton
Scanning Microscopy
Optical fluorescence is characteristic of molecules and their environment, and dyes can be made whose fluorescence is altered by reversible binding to specific ions. By introducing these into the cytosol, fluorescence microscopy can be used to form dynamic images of ionic activities in living cells under experimental manipulation. Optical fluorescence spectra are broad-band, and if specific ion binding alters the wavelength of maximal excitation or emission, quantitative measurements can be made from the ratio of images taken at two different wavelengths, eliminating errors due to spatial variations in dye concentration and optical path-length. This method is analogous to continuum normalisation …
Crystallization Of Calcium Oxalate And Calcium Phosphate At Supersaturation Levels Corresponding To Those In Different Parts Of The Nephron, Ján Lupták, Hanne Bek-Jensen, Anne-Marie Fornander, Inge Höjgaard, Mari-Anne Nilsson, Hans-Göran Tiselius
Crystallization Of Calcium Oxalate And Calcium Phosphate At Supersaturation Levels Corresponding To Those In Different Parts Of The Nephron, Ján Lupták, Hanne Bek-Jensen, Anne-Marie Fornander, Inge Höjgaard, Mari-Anne Nilsson, Hans-Göran Tiselius
Scanning Microscopy
The risk of crystallization in solutions, with a composition corresponding to that of urine in various parts of the nephron, was assessed by studying urine samples containing standardized increments of calcium and oxalate concentrations. The experiments were carried out in salt solutions with and without dialysed urine and the appearance of crystals was detected and measured with a Coulter counter. With increased concentrations of calcium, crystals of calcium phosphate were predominantly formed in solutions with a composition corresponding to that in the proximal and distal tubuli, whereas, calcium oxalate was the primary crystallization product in solutions with a composition corresponding …
Effects Of Acute Acid Loading On The Risk Of Calcium Phosphate And Calcium Oxalate Crystallization In Urine, P. J. Osther, J. Bollerslev, J. R. Nørgård, K. Engel, P. Kildeberg
Effects Of Acute Acid Loading On The Risk Of Calcium Phosphate And Calcium Oxalate Crystallization In Urine, P. J. Osther, J. Bollerslev, J. R. Nørgård, K. Engel, P. Kildeberg
Scanning Microscopy
The aim of this study was to examine the risk of calcium phosphate and calcium oxalate crystallization during acute acid loading under controlled conditions.
The effects of acute acid loading on rates of renal excretion of calcium, magnesium, phosphate, citrate, oxalate and urine pH were studied in healthy subjects. The risk of calcium phosphate and calcium oxalate crystallization were evaluated by estimates of the ion activity products of calcium phosphate [AP(CaP)-index] and calcium oxalate [AP(CaOx)-index] according to Tiselius. In addition, the risk of brushite [AP(Bru)-index] crystallization was estimated.
An acute acid load administered as ammonium chloride (NH4Cl) produced …
Changes Of Ion And Water Content Of Mouse Intestinal Cells After Pilocarpine And Isoproterenol Stimulation, Thomas Von Zglinicki, Godfried M. Roomans
Changes Of Ion And Water Content Of Mouse Intestinal Cells After Pilocarpine And Isoproterenol Stimulation, Thomas Von Zglinicki, Godfried M. Roomans
Scanning Microscopy
Cytoplasmic monovalent ion and water contents in morphologically defined mice jejuna) cells were measured by X-ray microanalysis in order to gain insight into the cell-type specificity of intestinal electrolyte transport mechanisms. Ion and water contents were measured independently. It was found that in some cases net fluxes of ions and water do not correspond to the assumption of constant osmotic activity of cytoplasmic Na and K ions. Stimulation of secretion with the cholinergic secretagogue pilocarpine resulted in efflux of Cl- from and influx of K+ into crypt enterocytes containing small secretion granula (crypt A cells). No significant changes …
Laser Microprobe Mass Spectrometry In Biology And Biomedicine, S. Eeckhaoudt, L. Van Vaeck, R. Gijbels, R. E. Van Grieken
Laser Microprobe Mass Spectrometry In Biology And Biomedicine, S. Eeckhaoudt, L. Van Vaeck, R. Gijbels, R. E. Van Grieken
Scanning Microscopy
An overview is given of laser microprobe mass spectrometry (LMMS) in biology and biomedicine (1989-1993). The present instrumentation and its analytical features are surveyed. Applications are presented with special attention on human and animal tissue samples, as well as plant material. The capabilities of LMMS to study the element distribution in histological sections, to identify the chemical composition of inorganic inclusions and to generate structural information from organic compounds are evidenced.
X-Ray Microanalysis With The Environmental Scanning Electron Microscope: Interpretation Of Data Obtained Under Different Atmospheric Conditions, D. C. Sigee, C. Gilpin
X-Ray Microanalysis With The Environmental Scanning Electron Microscope: Interpretation Of Data Obtained Under Different Atmospheric Conditions, D. C. Sigee, C. Gilpin
Scanning Microscopy
X-ray microanalysis of non-biological and biological specimens was carried out in an environmental scanning electron microscope (ESEM) over a range of atmospheric conditions. Introduction of water vapour into the specimen chamber lead to direct X-ray contribution from oxygen atoms, an increase in extraneous background (causing reduced P/B ratios of other elements), X-ray absorption (also reducing P/B ratios) and broadening (skirting) of the electron beam. Similar results were obtained after introduction of an argon atmosphere. These effects were reduced under conditions of minimal chamber atmospheric pressure and maximal accelerating voltage.
Because of beam skirting, quantitative X-ray microanalysis of biological specimens in …
Ion Microscopy In Biology, George H. Morrison, Isabelle Gay, Subhash Chandra
Ion Microscopy In Biology, George H. Morrison, Isabelle Gay, Subhash Chandra
Scanning Microscopy
Ion microscopy, a mass spectrometry based isotopic imaging technique, is uniquely suited for ion transport-related problems in biological systems. Due to its high sensitivity, it can image the transport and distribution of both major and minor elements (isotopes) at subcellular resolutions. The images of major elements such as K, Na, Cl, etc., can be viewed directly and recorded in real-time from the microchannel plate-fluorescent screen detector of the instrument. The low concentration physiologically important elements, such as Ca, need about one minute of integration for good quality imaging. The isotopic imaging capability of ion microscopy provides a unique approach for …