Monaural Cue Sound Localizer, John G. Harris, Chiang Jung Pu, Jose C. Principe Jan 2000

Monaural Cue Sound Localizer, John G. Harris, Chiang Jung Pu, Jose C. Principe

Electrical and Computer Engineering Faculty Research & Creative Works

We describe the first single microphone sound localization system and its inspiration from theories of human monaural sound localization. Reflections and diffractions caused by the external ear (pinna) allow humans to estimate sound source elevations using only one ear. Our single microphone localization model relies on a specially shaped reflecting structure that serves the role of the pinna. Specially designed analog VLSI circuitry uses echo-time processing to localize the sound. A CMOS integrated circuit has been designed, fabricated, and successfully demonstrated on actual sounds.


Effects Of Cosolvents And Ph On Protein Adsorption On Polystyrene Latex: A Dynamic Light Scattering Study, Da Song, Daniel Forciniti Jan 2000

Effects Of Cosolvents And Ph On Protein Adsorption On Polystyrene Latex: A Dynamic Light Scattering Study, Da Song, Daniel Forciniti

Chemical and Biochemical Engineering Faculty Research & Creative Works

Dynamic light scattering was used to study the adsorption of two proteins with different surface properties (IgG and HSA) on negatively charged polystyrene latex. The proteins were adsorbed from water and from water/methanol and water/glycerol mixtures at various pH. Some striking differences between the adsorption behaviors of the proteins were observed. Whereas the thickness of the adsorbed layer of HSA was extremely sensitive to pH and solvent composition, that of IgG was not. IgG mainly showed an end-on orientation on polystyrene whereas several different surface orientations are suggested for HSA under different conditions. The addition of methanol inhibited the adsorption …


Applicability Of Ozone In Small Drinking Water Systems, Craig D. Adams, Justin Sutherland Jan 2000

Applicability Of Ozone In Small Drinking Water Systems, Craig D. Adams, Justin Sutherland

Civil, Architectural and Environmental Engineering Faculty Research & Creative Works

The use of ozone in water treatment plants is expanding rapidly in the United States. Ozone offers excellent disinfection properties (including chlorine-resistant pathogens) and does not form trihalomethanes. Additionally, ozone can be used to achieve or control many other water quality parameters such as color, taste and odor, and inorganic and organic contaminant concentrations. Control of ozone's disinfection byproducts such as bromate (formed in high bromide waters) is required. This presentation will review the synergistic effects of ozone applicable to use in small water treatment plants.


Accumulation Of Heavy Metals By Vegetables Grown In Mine Wastes, George P. Cobb, Kristin Sands, Melissa Waters, Bobby G. Wixson, Elaine Dorward-King Jan 2000

Accumulation Of Heavy Metals By Vegetables Grown In Mine Wastes, George P. Cobb, Kristin Sands, Melissa Waters, Bobby G. Wixson, Elaine Dorward-King

Civil, Architectural and Environmental Engineering Faculty Research & Creative Works

Lead, cadmium, arsenic, and zinc were quantified in mine wastes and in soils mixed with mine wastes. Metal concentrations were found to be heterogeneous in the wastes. Iceberg lettuce, Cherry Belle radishes, Roma bush beans, and Better Boy tomatoes were cultivated in mine wastes and in waste-amended soils. Lettuce and radishes had 100% survival in the 100% mine waste treatments compared to 0% and 25% survival for tomatoes and beans, respectively. Metal concentrations were determined in plant tissues to determine uptake and distribution of metals in the edible plant parts. Individual soil samples were collected beneath each plant to assess …


Development Of A Functional Basis For Design, Robert B. Stone, Kristin L. Wood Jan 2000

Development Of A Functional Basis For Design, Robert B. Stone, Kristin L. Wood

Mechanical and Aerospace Engineering Faculty Research & Creative Works

Functional models represent a form independent blueprint of a product. As with any blueprint or schematic, a consistent language or coding system is required to ensure others can read it. This paper introduces such a design language, called a functional basis, where product function is characterized in a verb-object (function-flow) format. The set of functions and flows is intended to comprehensively describe the mechanical design space. Clear definitions are provided for each function and flow. The functional basis is compared to previous functional representations and is shown to subsume these attempts as well as offer a more consistent classification scheme. …


Electroporation Dynamics In Biological Cells Subjected To Ultrafast Electrical Pulses: A Numerical Simulation Study, R. P. Joshi, K. H. Schoenbach Jan 2000

Electroporation Dynamics In Biological Cells Subjected To Ultrafast Electrical Pulses: A Numerical Simulation Study, R. P. Joshi, K. H. Schoenbach

Bioelectrics Publications

A model analysis of electroporation dynamics in biological cells has been carried out based on the Smoluchowski equation. Results of the cellular response to short, electric pulses are presented, taking account of the growth and resealing dynamics of transient aqueous pores. It is shown that the application of large voltages alone may not be sufficient to cause irreversible breakdown, if the time duration is too short. Failure to cause irreversible damage at small pulse widths could be attributed to the time inadequacy for pores to grow and expand beyond a critical threshold radius. In agreement with earlier studies, it is …


Kentucky Water Resources Research Institute Annual Technical Report Fy 1999, Kentucky Water Resources Research Institute, University Of Kentucky Jan 2000

Kentucky Water Resources Research Institute Annual Technical Report Fy 1999, Kentucky Water Resources Research Institute, University Of Kentucky

KWRRI Annual Technical Reports (USGS’s 104b Grant Program)

The FY 1999 Annual Technical Report for Kentucky consolidates the reporting requirements of the Section 104(b) base grant and regional competitive grant awards in a single technical report which includes: 1) a synopsis of each ongoing research project and each research project completed during the period, 2) a list of related reports published, 3) a brief description of information transfer activities, 4) a summary of student support during the reporting period, and 5) notable achievements and awards during the year. The activities supported by Section 104 (b) and the required matching funds are interwoven into the Kentucky Water Resources ResearchInsitute's …


Chemical Oxidation Of Mtbe Under O2-Rich And O2-Limited Environments Coupled With Biological Degradation Of Oxidation Byproducts, J. Sutherland, B. Panka, Craig D. Adams, Joel Gerard Burken Jan 2000

Chemical Oxidation Of Mtbe Under O2-Rich And O2-Limited Environments Coupled With Biological Degradation Of Oxidation Byproducts, J. Sutherland, B. Panka, Craig D. Adams, Joel Gerard Burken

Civil, Architectural and Environmental Engineering Faculty Research & Creative Works

The H2O2/UV Advanced Oxidation Process (AOP) Was Investigated to Determine Byproduct Formation under Different Experimental Conditions (PH, Alkalinity, and H2O2/UV Dose). a Key Factor in the Efficiency of the AOP Was the Dissolved Oxygen Concentration. Gas Chromatography/mass Spectrometry (GC/MS) Analysis Was Used to Identify Byproducts Resulting from Oxidation under Oxygen-Rich and Oxygen-Limited Conditions. Resultant Oxidation Byproducts Were Analyzed for their Susceptibility to Biological Degradation. Biodegradation Rate Constants Were Determined and Modeled for the Primary Byproducts of the Advanced Oxidation Process. Inhibition Resulting from the Presence of Multiple Byproducts in a Biological System Was Investigated as Well. Effects of Process Parameters …


Dead-Time Compensators: Performance And Robustness Issues, James Syder, Thomas Heeg, Aidan O'Dwyer Jan 2000

Dead-Time Compensators: Performance And Robustness Issues, James Syder, Thomas Heeg, Aidan O'Dwyer

Conference papers

This paper will compare a number of PID and predictive controller strategies to compensate processes modelled in first order lag plus time delay (FOLPD) form. The performance and robustness of the resulting compensated systems are evaluated analytically (where appropriate) and in simulation.


Pid Compensation Of Time Delayed Processes: A Survey, Aidan O'Dwyer Jan 2000

Pid Compensation Of Time Delayed Processes: A Survey, Aidan O'Dwyer

Conference papers

An extensive literature exists on the PID compensation of time delayed processes. It is possible to identify themes that are common to many of the available techniques. The intention of the paper is to provide a framework against which the literature may be viewed.


Test 1778: John Deere 8410t And 8420t Diesel 16-Speed, Nebraska Tractor Test Lab Jan 2000

Test 1778: John Deere 8410t And 8420t Diesel 16-Speed, Nebraska Tractor Test Lab

Nebraska Tractor Tests

ABOUT THE TEST REPORT AND USE OF THE DATA

The test data contained in this report are a tabulation of the results of a series of tests. Due to the restricted format of these pages, only a limited amount of data and not all of the tractor specifications are included. The full OECD report contains usually about 30 pages of data and specifications. The test data were obtained for each tractor under similar conditions and therefore, provide a means of comparison of performance based on a limited set of reported data.

EXPLANATION OF THE TEST PROCEDURES

Purpose

The purpose of …


Test 1767: Agco Allis 8745 Diesel 12-Speed, Nebraska Tractor Test Lab Jan 2000

Test 1767: Agco Allis 8745 Diesel 12-Speed, Nebraska Tractor Test Lab

Nebraska Tractor Tests

ABOUT THE TEST REPORT AND USE OF THE DATA

The test data contained in this report are a tabulation of the results of a series of tests. Due to the restricted format of these pages, only a limited amount of data and not all of the tractor specifications are included. The full OECD report contains usually about 30 pages of data and specifications. The test data were obtained for each tractor under similar conditions and therefore, provide a means of comparison of performance based on a limited set of reported data.

EXPLANATION OF THE TEST PROCEDURES

Purpose

The purpose of …


Test 1770: John Deere 5105 Diesel 8-Speed, Nebraska Tractor Test Lab Jan 2000

Test 1770: John Deere 5105 Diesel 8-Speed, Nebraska Tractor Test Lab

Nebraska Tractor Tests

ABOUT THE TEST REPORT AND USE OF THE DATA

The test data contained in this report are a tabulation of the results of a series of tests. Due to the restricted format of these pages, only a limited amount of data and not all of the tractor specifications are included. The full OECD report contains usually about 30 pages of data and specifications. The test data were obtained for each tractor under similar conditions and therefore, provide a means of comparison of performance based on a limited set of reported data.

EXPLANATION OF THE TEST PROCEDURES

Purpose

The purpose of …


Test 1781: White 8510 Diesel 18-Speed, Nebraska Tractor Test Lab Jan 2000

Test 1781: White 8510 Diesel 18-Speed, Nebraska Tractor Test Lab

Nebraska Tractor Tests

ABOUT THE TEST REPORT AND USE OF THE DATA

The test data contained in this report are a tabulation of the results of a series of tests. Due to the restricted format of these pages, only a limited amount of data and not all of the tractor specifications are included. The full OECD report contains usually about 30 pages of data and specifications. The test data were obtained for each tractor under similar conditions and therefore, provide a means of comparison of performance based on a limited set of reported data.

EXPLANATION OF THE TEST PROCEDURES

Purpose

The purpose of …


Test 1772: John Deere 8110 Diesel 16-Speed, Nebraska Tractor Test Lab Jan 2000

Test 1772: John Deere 8110 Diesel 16-Speed, Nebraska Tractor Test Lab

Nebraska Tractor Tests

ABOUT THE TEST REPORT AND USE OF THE DATA

The test data contained in this report are a tabulation of the results of a series of tests. Due to the restricted format of these pages, only a limited amount of data and not all of the tractor specifications are included. The full OECD report contains usually about 30 pages of data and specifications. The test data were obtained for each tractor under similar conditions and therefore, provide a means of comparison of performance based on a limited set of reported data.

EXPLANATION OF THE TEST PROCEDURES

Purpose

The purpose of …


Test 1782: White 8610 Diesel 18-Speed, Nebraska Tractor Test Lab Jan 2000

Test 1782: White 8610 Diesel 18-Speed, Nebraska Tractor Test Lab

Nebraska Tractor Tests

ABOUT THE TEST REPORT AND USE OF THE DATA

The test data contained in this report are a tabulation of the results of a series of tests. Due to the restricted format of these pages, only a limited amount of data and not all of the tractor specifications are included. The full OECD report contains usually about 30 pages of data and specifications. The test data were obtained for each tractor under similar conditions and therefore, provide a means of comparison of performance based on a limited set of reported data.

EXPLANATION OF THE TEST PROCEDURES

Purpose

The purpose of …


Test 1777: John Deere 8410 Diesel 16-Speed, Nebraska Tractor Test Lab Jan 2000

Test 1777: John Deere 8410 Diesel 16-Speed, Nebraska Tractor Test Lab

Nebraska Tractor Tests

ABOUT THE TEST REPORT AND USE OF THE DATA

The test data contained in this report are a tabulation of the results of a series of tests. Due to the restricted format of these pages, only a limited amount of data and not all of the tractor specifications are included. The full OECD report contains usually about 30 pages of data and specifications. The test data were obtained for each tractor under similar conditions and therefore, provide a means of comparison of performance based on a limited set of reported data.

EXPLANATION OF THE TEST PROCEDURES

Purpose

The purpose of …


Test 1787: John Deere 7610 Powrquad Diesel 20-Speed (Chassis S/N Rw7610r030002 And Higher), Nebraska Tractor Test Lab Jan 2000

Test 1787: John Deere 7610 Powrquad Diesel 20-Speed (Chassis S/N Rw7610r030002 And Higher), Nebraska Tractor Test Lab

Nebraska Tractor Tests

ABOUT THE TEST REPORT AND USE OF THE DATA

The test data contained in this report are a tabulation of the results of a series of tests. Due to the restricted format of these pages, only a limited amount of data and not all of the tractor specifications are included. The full OECD report contains usually about 30 pages of data and specifications. The test data were obtained for each tractor under similar conditions and therefore, provide a means of comparison of performance based on a limited set of reported data.

EXPLANATION OF THE TEST PROCEDURES

Purpose

The purpose of …


Test 1776: John Deere 8310t Diesel 16-Speed, Nebraska Tractor Test Lab Jan 2000

Test 1776: John Deere 8310t Diesel 16-Speed, Nebraska Tractor Test Lab

Nebraska Tractor Tests

ABOUT THE TEST REPORT AND USE OF THE DATA

The test data contained in this report are a tabulation of the results of a series of tests. Due to the restricted format of these pages, only a limited amount of data and not all of the tractor specifications are included. The full OECD report contains usually about 30 pages of data and specifications. The test data were obtained for each tractor under similar conditions and therefore, provide a means of comparison of performance based on a limited set of reported data.

EXPLANATION OF THE TEST PROCEDURES

Purpose

The purpose of …


Test 1780: White 6810 Diesel 32-Speed, Nebraska Tractor Test Lab Jan 2000

Test 1780: White 6810 Diesel 32-Speed, Nebraska Tractor Test Lab

Nebraska Tractor Tests

ABOUT THE TEST REPORT AND USE OF THE DATA

The test data contained in this report are a tabulation of the results of a series of tests. Due to the restricted format of these pages, only a limited amount of data and not all of the tractor specifications are included. The full OECD report contains usually about 30 pages of data and specifications. The test data were obtained for each tractor under similar conditions and therefore, provide a means of comparison of performance based on a limited set of reported data.

EXPLANATION OF THE TEST PROCEDURES

Purpose

The purpose of …


Test 1788: John Deere 7710 Powrquad Diesel 20-Speed (Chassis S/N Rw7710h030004 And Higher), Nebraska Tractor Test Lab Jan 2000

Test 1788: John Deere 7710 Powrquad Diesel 20-Speed (Chassis S/N Rw7710h030004 And Higher), Nebraska Tractor Test Lab

Nebraska Tractor Tests

ABOUT THE TEST REPORT AND USE OF THE DATA

The test data contained in this report are a tabulation of the results of a series of tests. Due to the restricted format of these pages, only a limited amount of data and not all of the tractor specifications are included. The full OECD report contains usually about 30 pages of data and specifications. The test data were obtained for each tractor under similar conditions and therefore, provide a means of comparison of performance based on a limited set of reported data.

EXPLANATION OF THE TEST PROCEDURES

Purpose

The purpose of …


Test 1786: John Deere 7510 Powrquad Diesel 16-Speed, Nebraska Tractor Test Lab Jan 2000

Test 1786: John Deere 7510 Powrquad Diesel 16-Speed, Nebraska Tractor Test Lab

Nebraska Tractor Tests

ABOUT THE TEST REPORT AND USE OF THE DATA

The test data contained in this report are a tabulation of the results of a series of tests. Due to the restricted format of these pages, only a limited amount of data and not all of the tractor specifications are included. The full OECD report contains usually about 30 pages of data and specifications. The test data were obtained for each tractor under similar conditions and therefore, provide a means of comparison of performance based on a limited set of reported data.

EXPLANATION OF THE TEST PROCEDURES

Purpose

The purpose of …


Test 1794a: Agco Allis 9775 Navistar Diesel 18-Speed, Nebraska Tractor Test Lab Jan 2000

Test 1794a: Agco Allis 9775 Navistar Diesel 18-Speed, Nebraska Tractor Test Lab

Nebraska Tractor Tests

ABOUT THE TEST REPORT AND USE OF THE DATA The test data contained in this report are a tabulation of the results of a series of tests. Due to the restricted format of these pages, only a limited amount of data and not all of the tractor specifications are included. The full OECD report contains usually about 30 pages of data and specifications. The test data were obtained for each tractor under similar conditions and therefore, provide a means of comparison of performance based on a limited set of reported data. EXPLANATION OF THE TEST PROCEDURES Purpose The purpose of …


Test 1780a: Agco Allis 8785 Diesel 32-Speed, Nebraska Tractor Test Lab Jan 2000

Test 1780a: Agco Allis 8785 Diesel 32-Speed, Nebraska Tractor Test Lab

Nebraska Tractor Tests

ABOUT THE TEST REPORT AND USE OF THE DATA

The test data contained in this report are a tabulation of the results of a series of tests. Due to the restricted format of these pages, only a limited amount of data and not all of the tractor specifications are included. The full OECD report contains usually about 30 pages of data and specifications. The test data were obtained for each tractor under similar conditions and therefore, provide a means of comparison of performance based on a limited set of reported data.

EXPLANATION OF THE TEST PROCEDURES

Purpose

The purpose of …


Test 1782a: Agco Allis 9765 Diesel 18-Speed, Nebraska Tractor Test Lab Jan 2000

Test 1782a: Agco Allis 9765 Diesel 18-Speed, Nebraska Tractor Test Lab

Nebraska Tractor Tests

ABOUT THE TEST REPORT AND USE OF THE DATA

The test data contained in this report are a tabulation of the results of a series of tests. Due to the restricted format of these pages, only a limited amount of data and not all of the tractor specifications are included. The full OECD report contains usually about 30 pages of data and specifications. The test data were obtained for each tractor under similar conditions and therefore, provide a means of comparison of performance based on a limited set of reported data.

EXPLANATION OF THE TEST PROCEDURES

Purpose

The purpose of …


Test 1782b: Massey Ferguson 8260 18-Speed, Nebraska Tractor Test Lab Jan 2000

Test 1782b: Massey Ferguson 8260 18-Speed, Nebraska Tractor Test Lab

Nebraska Tractor Tests

ABOUT THE TEST REPORT AND USE OF THE DATA

The test data contained in this report are a tabulation of the results of a series of tests. Due to the restricted format of these pages, only a limited amount of data and not all of the tractor specifications are included. The full OECD report contains usually about 30 pages of data and specifications. The test data were obtained for each tractor under similar conditions and therefore, provide a means of comparison of performance based on a limited set of reported data.

EXPLANATION OF THE TEST PROCEDURES

Purpose

The purpose of …


Nebraska Summary 360: Massey Ferguson 4233 And 4335 Diesel 12-Speed, Nebraska Tractor Test Lab Jan 2000

Nebraska Summary 360: Massey Ferguson 4233 And 4335 Diesel 12-Speed, Nebraska Tractor Test Lab

Nebraska Tractor Tests

ABOUT THE TEST REPORT AND USE OF THE DATA

The test data contained in this report are a tabulation of the results of a series of tests. Due to the restricted format of these pages, only a limited amount of data and not all of the tractor specifications are included. The full OECD report contains usually about 30 pages of data and specifications. The test data were obtained for each tractor under similar conditions and therefore, provide a means of comparison of performance based on a limited set of reported data.

EXPLANATION OF THE TEST PROCEDURES

Purpose

The purpose of …


Nebraska Summary; S342 New Holland Tm115, Nebraska Tractor Test Lab Jan 2000

Nebraska Summary; S342 New Holland Tm115, Nebraska Tractor Test Lab

Nebraska Tractor Tests

ABOUT THE TEST REPORT AND USE OF THE DATA The test data contained in this report are a tabulation of the results of a series of tests. Due to the restricted format of these pages, only a limited amount of data and not all of the tractor specifications are included. The full OECD report contains usually about 30 pages of data and specifications. The test data were obtained for each tractor under similar conditions and therefore, provide a means of comparison of performance based on a limited set of reported data. EXPLANATION OF THE TEST PROCEDURES Purpose The purpose of …


Nebraska Summary: S346 New Holland Tm165, Nebraska Tractor Test Lab Jan 2000

Nebraska Summary: S346 New Holland Tm165, Nebraska Tractor Test Lab

Nebraska Tractor Tests

ABOUT THE TEST REPORT AND USE OF THE DATA The test data contained in this report are a tabulation of the results of a series of tests. Due to the restricted format of these pages, only a limited amount of data and not all of the tractor specifications are included. The full OECD report contains usually about 30 pages of data and specifications. The test data were obtained for each tractor under similar conditions and therefore, provide a means of comparison of performance based on a limited set of reported data. EXPLANATION OF THE TEST PROCEDURES Purpose The purpose of …


Nebraska Summary: S345 New Holland Tm150, Nebraska Tractor Test Lab Jan 2000

Nebraska Summary: S345 New Holland Tm150, Nebraska Tractor Test Lab

Nebraska Tractor Tests

ABOUT THE TEST REPORT AND USE OF THE DATA The test data contained in this report are a tabulation of the results of a series of tests. Due to the restricted format of these pages, only a limited amount of data and not all of the tractor specifications are included. The full OECD report contains usually about 30 pages of data and specifications. The test data were obtained for each tractor under similar conditions and therefore, provide a means of comparison of performance based on a limited set of reported data. EXPLANATION OF THE TEST PROCEDURES Purpose The purpose of …