Open Access. Powered by Scholars. Published by Universities.®
- Institution
-
- California Polytechnic State University, San Luis Obispo (61)
- Michigan Technological University (35)
- New Jersey Institute of Technology (31)
- Utah State University (30)
- Wright State University (29)
-
- Clemson University (25)
- University of Nebraska - Lincoln (19)
- University of Arkansas, Fayetteville (18)
- Al Esraa University (16)
- Missouri University of Science and Technology (16)
- Raynor Library Marquette University (16)
- Yıldız Technical University (13)
- Cleveland State University (12)
- University of South Florida (12)
- Louisiana Tech University (11)
- The University of Akron (10)
- Virginia Commonwealth University (10)
- Old Dominion University (8)
- Rowan University (8)
- Tashkent State Technical University (8)
- University of Kentucky (8)
- Boise State University (7)
- Florida Institute of Technology (7)
- Wayne State University (7)
- Louisiana State University (6)
- Purdue University (6)
- Technological University Dublin (6)
- University of Louisville (6)
- University of Mississippi (6)
- Santa Clara University (5)
- Keyword
-
- Corrosion (18)
- Department of Biomedical Engineering (17)
- Biomaterials (15)
- Biocompatibility (11)
- Magnesium (11)
-
- Microstructure (11)
- Engineering (10)
- Implants (10)
- Microfluidics (10)
- Stent (10)
- Tissue engineering (10)
- Titanium (10)
- Applied sciences (9)
- Biosensors (9)
- Biodegradable (8)
- Mechanical engineering and machinery (8)
- TJ1-1570 (8)
- Bone (7)
- Mechanical properties (7)
- Zinc (7)
- Biofilm (6)
- Biomechanics (6)
- Biomedical (6)
- Biomedical engineering (6)
- Bioreactor (6)
- Dental alloy (6)
- Department of Biomedical, Industrial & Human Factors Engineering (6)
- Nanotechnology (6)
- Prosthesis (6)
- Prosthetic (6)
- Publication Year
- Publication
-
- Theses and Dissertations (30)
- Theses (27)
- Biomedical Engineering (26)
- Master's Theses (22)
- Biomedical, Industrial & Human Factors Engineering Faculty Publications (21)
-
- Cells and Materials (19)
- Al-Esraa University College Journal for Engineering Sciences (16)
- All Dissertations (16)
- Biomedical Engineering Faculty Research and Publications (15)
- Chemical and Biochemical Engineering Faculty Research & Creative Works (14)
- Journal of Sustainable Construction Materials and Technologies (13)
- Michigan Tech Publications, Part 1 (13)
- Dissertations, Master's Theses and Master's Reports (12)
- USF Tampa Graduate Theses and Dissertations (12)
- Doctoral Dissertations (11)
- Graduate Theses and Dissertations (11)
- ETD Archive (10)
- Electronic Theses and Dissertations (10)
- Williams Honors College, Honors Research Projects (10)
- Browse all Theses and Dissertations (8)
- Honors Theses (8)
- Technical science and innovation (8)
- All Theses (7)
- Department of Agricultural and Biological Systems Engineering: Faculty Publications (7)
- All Graduate Theses and Dissertations, Spring 1920 to Summer 2023 (6)
- Dissertations (6)
- Mechanical Engineering (6)
- Materials Engineering (5)
- Mechanical and Biomedical Engineering Faculty Publications and Presentations (5)
- Articles (4)
- Publication Type
Articles 331 - 360 of 529
Full-Text Articles in Entire DC Network
Biomaterial Testing Methodology For Long-Term In Vivo Applications: Silicon Carbide Corrosion Resistance, Biocompatibility And Hemocompatibility, Maysam Nezafati
Biomaterial Testing Methodology For Long-Term In Vivo Applications: Silicon Carbide Corrosion Resistance, Biocompatibility And Hemocompatibility, Maysam Nezafati
USF Tampa Graduate Theses and Dissertations
Biomedical devices that function in-vivo offer a tremendous promise to improve the quality of life for many who suffer from disease and trauma. The most important consideration for these devices is that they interact with the physiological environment as designed without initiating a deleterious inflammatory response. ISO 10993 outlines the current international guideline for investigating the biocompatibility of such devices. Numerous groups report the use of ISO 10993 as the basis for their experimental evaluation of candidate materials for neuroprosthetics, as well as other biomedical devices, however most of these reports fail to completely comply with the standard. This leads …
Molecular And Device Engineering Towards The Study Of Potential Anti-Mrsa Agents, Powell Fansler, Karla Geisse, Ryan Marshall
Molecular And Device Engineering Towards The Study Of Potential Anti-Mrsa Agents, Powell Fansler, Karla Geisse, Ryan Marshall
Bioengineering Senior Theses
At the intersection of bio-device engineering and bio-pharmaceutical studies, our project involved the design of a hydraulic manifold to be used in isothermal titration calorimetry (ITC), with the ultimate goal of using ITC to study the thermodynamic binding parameters of potential anti-Methicillin Resistant Staphylococcus aureus (MRSA) agents to our drug target, Sortase A. The hydraulic manifold redesign included the analysis of materials such as high density polyethylene (HDPE), polytetrafluorethylene (PTFE, ‘Teflon’), and polycarbonate as well as the implementation of a new construct of the manifold itself. Sortase A is a transpeptidase found in Gram-positive bacteria and catalyses the attachment of …
Development Of A Multi-Purpose Automated Synthesis Module For Production Of Novel Pet Radiopharmaceuticals, I Hong Shih
Development Of A Multi-Purpose Automated Synthesis Module For Production Of Novel Pet Radiopharmaceuticals, I Hong Shih
Dissertations and Theses (Open Access)
Among radiopharmaceuticals of positron emission tomography (PET), 18F-Fluorodeoxyglucose (18F-FDG) made from commercialized automated synthesis module is the most frequently used in tumor diagnoses. But the false positive findings, such as infectious tissues and post-operative surgical conditions, show strong uptake of 18F-FDG in PET scans which requires extra clinical procedures to confirm the results. Moreover, the false negative findings, such as low glycolytic activity tumors, reduce the accuracy of PET scans. Therefore, there will be new PET radiopharmaceuticals to redeem the defects of 18FDG-PET applications.
Current commercialized automated synthesis modules are suitable for clinical use, but …
Optimization Of Wastewater Microalgae Pretreatment For Acetone, Butanol, And Ethanol Fermentation, Yessica A. Castro
Optimization Of Wastewater Microalgae Pretreatment For Acetone, Butanol, And Ethanol Fermentation, Yessica A. Castro
All Graduate Theses and Dissertations, Spring 1920 to Summer 2023
Acetone-butanol-ethanol (ABE) fermentation from wastewater microalgae by Clostridium saccharoperbutylacetonicum N1-4 is a novel bioprocess that utilizes waste substrate to generate valuable solvents. Butanol, the most abundant product resulting from ABE fermentation, is an environmentally safe and high performing fuel that can be utilized as a drop-in-fuel; however, high operational costs and low ABE yield present challenge in scale-up of the process. The utilization of algae as a substrate requires pretreatment prior to fermentation to increase the bioavailability of the algal fermentable sugars and to improve the conditions of the pre-fermentation medium. The purpose of this thesis was to optimize wastewater …
Effect Of Poultry Litter Biochar On Saccharomyces Cerevisiae Growth And Ethanol Production From Steam-Exploded Poplar And Corn Stover, Oumou Diallo
All Graduate Theses and Dissertations, Spring 1920 to Summer 2023
The use of ethanol produced from lignocellulosic biomass for transportation fuel offers solutions in reducing environmental emission and the use of non-renewable fuels. However, lignocellulosic ethanol production is still hampered by economic and technical obstacles. For instance, the inhibitory effect of toxic compounds produced during biomass pretreatment was reported to inhibit the fermenting microorganisms, hence there was a decrease in ethanol yield and productivity. Thus, there is a need to improve the bioconversion of lignocellulosic biomass to ethanol in order to promote its commercialization. The research reported here investigated the use of poultry litter biochar to improve the ethanol production …
Developing A Hardware Platform For A Low-Power, Low-Cost, Size-Constrained Biomechanical Telemetry System, Aditya Balasubramanian
Developing A Hardware Platform For A Low-Power, Low-Cost, Size-Constrained Biomechanical Telemetry System, Aditya Balasubramanian
Open Access Theses
As sport-related traumatic brain injuries face increasing attention from the media and the general public, the need to be able to detect brain injury quickly, inexpensively and accurately is more important than ever. Commercially-available event-based systems exist that claim to achieve this goal; however, they collect little to no continuous-time data and primarily indicate when a pre-determined acceleration threshold has been exceeded under the unvalidated assumption that a potentially concussive blow has occurred. Recent findings by the Purdue Neurotrauma Group (PNG) have indicated that repeated exposure to both concussive and subconcussive blows can result in cumulative trauma disorder. To track …
Summer 2014 Biomedical Engineering Newsletter, Department Of Biomedical Engineering, Michigan Technological University
Summer 2014 Biomedical Engineering Newsletter, Department Of Biomedical Engineering, Michigan Technological University
Department of Biomedical Engineering Newsletters
Table of Contents
- New IEEE, AIMBE and SPIE fellows
- Arteries on aisle 9
- Implants with sensors that shake off infection
- Mitch Kirby wins Whitaker International Fellowship
- Skin patch warns when it’s time to get out of the sun
Utilizing Fast Spin Echo Mri To Reduce Image Artifacts And Improve Implant/Tissue Interface Detection In Refractory Parkinson’S Patients With Deep Brain Stimulators, Subhendra N. Sarkar, Pooja R. Sarkar, Efstathios Papavassiliou, Rafael Rojas
Utilizing Fast Spin Echo Mri To Reduce Image Artifacts And Improve Implant/Tissue Interface Detection In Refractory Parkinson’S Patients With Deep Brain Stimulators, Subhendra N. Sarkar, Pooja R. Sarkar, Efstathios Papavassiliou, Rafael Rojas
Publications and Research
Introduction. In medically refractory Parkinson’s disease (PD) deep-brain stimulation (DBS) is an effective therapeutic tool. Postimplantation MRI is important in assessing tissue damage and DBS lead placement accuracy. We wanted to identify which MRI sequence can detectDBS leads with smallest artifactual signal void, allowing better tissue/electrode edge conspicuity.
Methods. Using an IRB approved protocol 8 advanced PDpatientswere imagedwithinMRconditional safety guidelines at lowRF power (SAR ≤ 0.1 W/kg) in coronal plane at 1.5T by various sequences.The image slices were subjectively evaluated for diagnostic quality and the lead contact diameters were compared to identify a sequence least affected by metallic leads.
Results …
Design Of Controlled Environment For Tissue Engineering, Malcolm Gerald Lapera
Design Of Controlled Environment For Tissue Engineering, Malcolm Gerald Lapera
Master's Theses
Design of Controlled Environment for Tissue Engineering
Malcolm Lapera
Tissue engineering aims at relieving the need for donor tissue and organs by developing a process of creating viable tissues in the laboratory setting. With over 120,000 people awaiting a transplant, the need for generating tissue engineered organs is very large [3]. In order for organs to be engineered, a few issues need to be overcome. A work space that both creates an environment which maintains cell viability over an extended period of time as well as accommodates the necessary fabrication equipment will be needed to further tissue engineering research. Therefore, …
In Vitro Modeling And Analysis Of Axon Stretch Growth For The Sustained Growth Of Long Nerve Fibers, Joseph Rocco Loverde
In Vitro Modeling And Analysis Of Axon Stretch Growth For The Sustained Growth Of Long Nerve Fibers, Joseph Rocco Loverde
Dissertations
The integration of long nerve fibers throughout the body is distinctive among somatic tissues. Single, individual motor neurons grow to a meter in length or more as they maintain connectivity with sacral areas of the spinal cord from the brain. Similarly, homologous growth also occurs via spinal ganglion neurons within the peripheral nervous system. The most widely studied aspect of nerve development has been the migration and extension of growth cones towards synaptic targets during early development. However, following growth cone extension, axonal fibers continue to grow in synchrony with the expansion of limbs and mit otic tissues throughout childhood …
Heavy Element Doping For Enhancing Thermoelectric Properties Of Nanostructured Zinc Oxide, Priyanka Jood, Rutvik J. Mehta, Yanliang Zhang, Theo Borca-Tasciuc, Shi Xue Dou, David J. Singh, Ganpati Ramanath
Heavy Element Doping For Enhancing Thermoelectric Properties Of Nanostructured Zinc Oxide, Priyanka Jood, Rutvik J. Mehta, Yanliang Zhang, Theo Borca-Tasciuc, Shi Xue Dou, David J. Singh, Ganpati Ramanath
Mechanical and Biomedical Engineering Faculty Publications and Presentations
ZnO is a high melting point, high charge carrier mobility semiconductor with potential as a thermoelectric material, but its high thermal conductivity κ is the limiting factor for increasing the thermoelectric figure of merit ZT. Here, we demonstrate that doping ZnO with heavy elements can significantly enhance ZT. Indium doping leads to ultralow κ 3 W m−1 K−1 and a high power factor α2σ 1.230 × 10−3 W m−1 K−2, yielding ZT1000K 0.45 that is 80% higher than non-nanostructured In–Zn–O alloys. Although Bi doping also yields a high Seebeck coefficient of …
Effects Of Environmental Heavy Metals On Neural Stem Cell Survival And Differentiation, Sameera S. Clev Tasneem
Effects Of Environmental Heavy Metals On Neural Stem Cell Survival And Differentiation, Sameera S. Clev Tasneem
ETD Archive
No abstract provided.
Development And Application Of Biomimetic Electrospun Nanofibers In Total Joint Replacement, Wei Song
Development And Application Of Biomimetic Electrospun Nanofibers In Total Joint Replacement, Wei Song
Wayne State University Dissertations
Failure of osseointegration (direct anchorage of an implant by bone formation at the bone-implant surface) and implant infection (such as that caused by Staphylococcus aureus, S. aureus) are the two main causes of implant failure and loosening. There is a critical need for orthopedic implants that promote rapid osseointegration and prevent bacterial colonization, particularly when placed in bone compromised by disease or physiology of the patients. A better understanding of the key factors that influence cell fate decisions at the bone-implant interface is required. Our study is to develop a class of "bone-like" nanofibers (NFs) that promote osseointegration while preventing …
Synergistic Toughening Of Hard, Nacre-Mimetic Mosi2 Coatings By Self-Assembled Hierarchical Structure, Jiang Xu, Xiaoli Zhao, Paul Munroe, Zonghan Xie
Synergistic Toughening Of Hard, Nacre-Mimetic Mosi2 Coatings By Self-Assembled Hierarchical Structure, Jiang Xu, Xiaoli Zhao, Paul Munroe, Zonghan Xie
Research outputs 2014 to 2021
Like many other intermetallic materials, MoSi2 coatings are typically hard, but prone to catastrophic failure due to their low toughness at ambient temperature. In this paper, a self-assembled hierarchical structure that closely resembles that of nacre (i.e., mother of pearl) was developed in a MoSi2 -based coating through a simple, yet cost-effective, depostion technique. The newly formed coating is tough and can withstand multiple indentations at high loads. Key design features responsible for this remarkable outcome were identified. They include a functionally graded multilayer featuring elastic modulus oscillation, varying sublayer thickness and a columnar structure that are able to attenuate …
Design And Application Of Wireless Passive Magnetoelastic Resonance And Magnetoharmonic Force Sensors, Brandon D. Pereles
Design And Application Of Wireless Passive Magnetoelastic Resonance And Magnetoharmonic Force Sensors, Brandon D. Pereles
Dissertations, Master's Theses and Master's Reports - Open
The objective of the work described in this dissertation is the development of new wireless passive force monitoring platforms for applications in the medical field, specifically monitoring lower limb prosthetics. The developed sensors consist of stress sensitive, magnetically soft amorphous metallic glass materials. The first technology is based on magnetoelastic resonance. Specifically, when exposed to an AC excitation field along with a constant DC bias field, the magnetoelastic material mechanically vibrates, and may reaches resonance if the field frequency matches the mechanical resonant frequency of the material. The presented work illustrates that an applied loading pins portions of the strip, …
Fabrication Of Drug Eluting Ti Implants For Dental/Orthopedic Applications, Azhang Hamlekhan
Fabrication Of Drug Eluting Ti Implants For Dental/Orthopedic Applications, Azhang Hamlekhan
Dissertations, Master's Theses and Master's Reports - Open
Titanium and its alloys are typically used for fabrication of dental and orthopedic implants as they possess various desirable properties including biocompatibility and corrosion resistance. In spite of such benefits, titanium implants show lack of osseointegration after surgery in minor cases. The objective of this research has been to modify the surface of titanium alloy for medical applications through increasing surface hydrophilicity and drug loading. Primarily, anodization method is employed for fabrication of nanotubes on titanium surface to act as anchoring cite for cells.
Considering the key role of surface hydrophilicity on cellular attachment to the surface and subsequent biological …
Magnesium-Titanium Alloys For Biomedical Applications, Ilona Hoffmann
Magnesium-Titanium Alloys For Biomedical Applications, Ilona Hoffmann
Theses and Dissertations--Chemical and Materials Engineering
Magnesium has been identified as a promising biodegradable implant material because it does not cause systemic toxicity and can reduce stress shielding. However, it corrodes too quickly in the body. Titanium, which is already used ubiquitously for implants, was chosen as the alloying element because of its proven biocompatibility and corrosion resistance in physiological environments. Thus, alloying magnesium with titanium is expected to improve the corrosion resistance of magnesium.
Mg-Ti alloys with a titanium content ranging from 5 to 35 at.-% were successfully synthesized by mechanical alloying. Spark plasma sintering was identified as a processing route to consolidate the alloy …
Theoretical And Experimental Investigations To Improve The Performance Of Surface Acoustic Wave (Saw) Biosensors, Mandek Richardson
Theoretical And Experimental Investigations To Improve The Performance Of Surface Acoustic Wave (Saw) Biosensors, Mandek Richardson
USF Tampa Graduate Theses and Dissertations
The objective of this dissertation is to improve the performance of surface acoustic wave (SAW) biosensors for use in point-of-care-testing (POCT) applications. SAW biosensors have the ability to perform fast, accurate detection of an analyte in real time without the use of labels. However, the technology suffers from the inability to differentiate between specific and non-specific binding. Due to this limitation, direct testing of bodily fluids using SAW sensors to accurately determine an analyte's concentration is difficult. In addition, these sensors are challenged by the need to detect small concentrations of a biomarker that are typically required to give a …
Which Design And Biomaterial Factors Affect Clinical Wear Performance Of Total Disc Replacements? A Systematic Review, Sai Y. Veruva, Marla J. Steinbeck, Jeffrey M. Toth, Dominik D. Alexander, Steven M. Kurtz
Which Design And Biomaterial Factors Affect Clinical Wear Performance Of Total Disc Replacements? A Systematic Review, Sai Y. Veruva, Marla J. Steinbeck, Jeffrey M. Toth, Dominik D. Alexander, Steven M. Kurtz
Biomedical Engineering Faculty Research and Publications
Background
Total disc replacement was clinically introduced to reduce pain and preserve segmental motion of the lumbar and cervical spine. Previous case studies have reported on the wear and adverse local tissue reactions around artificial prostheses, but it is unclear how design and biomaterials affect clinical outcomes.
Questions/purposes
Which design and material factors are associated with differences in clinical wear performance (implant wear and periprosthetic tissue response) of (1) lumbar and (2) cervical total disc replacements?
Methods
We performed a systematic review on the topics of implant wear and periprosthetic tissue response using an advanced search in MEDLINE and Scopus …
2013 Fall Engr333 Project Final Report, 2013 Fall Engr333
2013 Fall Engr333 Project Final Report, 2013 Fall Engr333
ENGR 333
During the fall of 2013, the Engineering 333 class was asked the question, “what would it take for Calvin College to operate a biofuel vehicle from campus resources?” The three primary considerations included:
- Determining the optimal biofuel feedstock in terms of availability, transportation, and processing.
- Selecting a biofuel vehicle for conversion or purchase to operate on the selected feedstock.
- Designing the infrastructure and process required for operating the selected biofuel vehicle. The design and research described below proposes an environmentally sustainable and cost-effective method for integrating a biofuel vehicle into Calvin’s existing infrastructure.
Fabrication And In Vivo Thrombogenecity Testing Of Nitric Oxide Generating Artificial Lungs, Kagya Amoako, Patrick Montoya, Terry C. Major, Ahmed B. Suhaib, Hitesh Handa, David O. Brant, Mark E. Meyerhoff, Robert H. Bartlett, Keith E. Cook
Fabrication And In Vivo Thrombogenecity Testing Of Nitric Oxide Generating Artificial Lungs, Kagya Amoako, Patrick Montoya, Terry C. Major, Ahmed B. Suhaib, Hitesh Handa, David O. Brant, Mark E. Meyerhoff, Robert H. Bartlett, Keith E. Cook
Mechanical and Industrial Engineering Faculty Publications
Hollow fiber artificial lungs are increasingly being used for long-term applications. However, clot formation limits their use to 1–2 weeks. This study investigated the effect of nitric oxide generating (NOgen) hollow fibers on artificial lung thrombogenicity. Silicone hollow fibers were fabricated to incorporate 50 nm copper particles as a catalyst for NO generation from the blood. Fibers with and without (control) these particles were incorporated into artificial lungs with a 0.1 m2 surface area and inserted in circuits coated tip-to-tip with the NOgen material. Circuits (N = 5/each) were attached to rabbits in a pumpless, arterio-venous configuration and run for …
Scratch Damage Evolution On Metals In Total Joint Replacements, Caleb Eljach
Scratch Damage Evolution On Metals In Total Joint Replacements, Caleb Eljach
All Theses
The goal of total joint replacement (TJR) is to replace nonfunctioning joint components and relieve pain, improve quality of life, and to improve joint function. Although TJR is a successful procedure, more than 54,000 knee revisions occur each year due to factors, such as wear, loosening, infection, fracture, instability, and patient related factors (Ranawat, 2010). TJRs consist of components typically composed of polyethylene and a metallic counterface (Navarro, 2008). The sliding contact that occurs between the metal and polyethylene components has been well studied and is shown to produce both surface damage and wear of the implant components (Barbour, 1997; …
Conventional And Catalytic Pyrolysis Of Pinyon Juniper Biomass, Bhuvanesh Kumar Yathavan
Conventional And Catalytic Pyrolysis Of Pinyon Juniper Biomass, Bhuvanesh Kumar Yathavan
All Graduate Theses and Dissertations, Spring 1920 to Summer 2023
Pinyon and juniper are invasive woody species which has occupied more than 47 million acres of land in Western United States. Pinyon juniper woodlands domination decreases the herbaceous vegetation, increase bare lands which in turn increases soil erosion and nutrition loss. Thus, The US Bureau of Land Management (BLM) has focused on harvesting these woody species to make room for herbaceous vegetation. The major application of harvested pinyon-juniper (PJ) is low value firewood. Thus, there is a need to develop new high value products from this woody biomass to reduce the cost of harvesting. In this study pyrolysis was carried …
Iron-Magnesium Alloy Bioabsorbable Blood Stent, Kaitlyn Jarry, L Stanciu
Iron-Magnesium Alloy Bioabsorbable Blood Stent, Kaitlyn Jarry, L Stanciu
The Summer Undergraduate Research Fellowship (SURF) Symposium
Bioabsorbable materials are fairly new and proper alloys for implantation in the body have not yet been established. There are a few polymers that have showed promise, but they do not provide the proper mechanical support that metal does. These materials would be used to create devices such as blood stents and orthopedic screws. Investigation into the properties of different alloys can help to establish a material that can be used for implanted devices that are only needed for a limited amount of time. In order to investigate these alloys many different experiments will to be run to test the …
Halloysite Nanotube Composites For Sustained Release Of Antimocrobial Agents (Antiseptics And Antibiotics), Wenbo Wei
Doctoral Dissertations
Encapsulation of antimicrobial agents (simple antiseptics and more specific antibiotics) within micro-scale and nano-scale containers may provide prolonged and more evenly distributed drug release. One of such containers proposed at Louisiana Tech is natural halloysite clay nanotubes. Halloysite is an aluminosilicate tube with a length of approximately 1 µm, outer diameter of approximately 50 nm, and internal lumen of 15 nm. The chemical composition of halloysite is similar to more common clay–kaolinite, and it can be described as rolled sheets of kaolinite. Halloysite, loaded with drugs inside its lumen, has shown aqueous release of the loaded chemicals over 10-20 hours …
Evaluation Of Corrosion Properties Of Proprietary Metal Alloy Stents For In-Vivo Use, Michael David Bremner
Evaluation Of Corrosion Properties Of Proprietary Metal Alloy Stents For In-Vivo Use, Michael David Bremner
Materials Engineering
To assess corrosion rates of metal alloy bio-absorbable stents an experimental set-up was designed to mimic the coronary artery environment. The artery was modeled using 4mm diameter Tecoflex tubing and the metal alloy stents were inserted into the tubing using a catheter. As is the case in cardiac surgery, the catheter with the stent and a microballoon were maneuvered to the desired position. The microballoon was then slowly inflated to expand the stent and compress it against the tubing walls. The catheter and microballoon were then withdrawn. A circulating pump system was set up to cycle fetal bovine serum (FBS) …
Fluorescence Characterization Of Quantum Dots For Use As Biomarkers, Logan M. Grimes
Fluorescence Characterization Of Quantum Dots For Use As Biomarkers, Logan M. Grimes
Materials Engineering
Fluorescence profiles of quantum dots (QDs) were characterized to select the ideal QDs for encapsulation in phospholipids for use as biomarkers to selectively adhere to cancer cells. QDs were synthesized and extracted 0, 30, 60, and 90 seconds after precursor compounds were mixed. These extractions were isolated by extraction time. Portions from each vial were coated in a zinc sulfide shelling procedure, leaving at least half of the QD solution unshelled. These samples were characterized over four days to monitor fluctuations in fluorescence. This was done utilizing an Ocean Optics spectrometer in conjunction with Spectra Suite software. The central wavelength, …
Beach Wheelchair Project, Rory Aronson, Joshua Marcum, Samuel Coyne, Alex Hayes, Alexa Colburn, Max Hessel, Benedikt Strauss, Marvin Rimmele, Marco Pietsch
Beach Wheelchair Project, Rory Aronson, Joshua Marcum, Samuel Coyne, Alex Hayes, Alexa Colburn, Max Hessel, Benedikt Strauss, Marvin Rimmele, Marco Pietsch
Mechanical Engineering
The Beach Wheelchair, Sandcrawler, is a machine intended to help give people with disabilities the full beach experience. The non-profit organization Bridge II Sports sponsored this project, and tasked us with developing the design and fabricating a prototype. This chair has several features including a linkage mechanism that raises and lowers a chair relative to an external frame, hand crank drive with Gates Carbondrive belt and sprockets, buoyant Wheeleez balloon tires, and much more.
Multilayer Bioactive Glass/Zirconium Titanate Thin Films In Bone Tissue Engineering And Regenerative Dentistry, Masoud Mozafari, Erfan Salahinejad, Vahid Shabafrooz, Mostafa Yazdimamaghani, Daryoosh Vashaee, Lobat Tayebi
Multilayer Bioactive Glass/Zirconium Titanate Thin Films In Bone Tissue Engineering And Regenerative Dentistry, Masoud Mozafari, Erfan Salahinejad, Vahid Shabafrooz, Mostafa Yazdimamaghani, Daryoosh Vashaee, Lobat Tayebi
Chemical and Biochemical Engineering Faculty Research & Creative Works
Surface modification, particularly coatings deposition, is beneficial to tissue-engineering applications. In this work, bioactive glass/zirconium titanate composite thin films were prepared by a sol-gel spin-coating method. The surface features of the coatings were studied by scanning electron microscopy, atomic force microscopy, and spectroscopic reflection analyses. The results show that uniform and sound multilayer thin films were successfully prepared through the optimization of the process variables and the application of carboxymethyl cellulose as a dispersing agent. Also, it was found that the thickness and roughness of the multilayer coatings increase nonlinearly with increasing the number of the layers. This new class …
Characterization Of Potential Wear Sources In Knee Arthroplasty Prostheses After In Vivo Function, Nicole Durig
Characterization Of Potential Wear Sources In Knee Arthroplasty Prostheses After In Vivo Function, Nicole Durig
All Theses
Total joint arthroplasty (TJA) is a common procedure generally performed in patients with osteoarthritis. While TJA continues to be a successful treatment for degenerative joint disease, there are many studies that demonstrate wear and its sequelae as the major limitation of joint replacement longevity. Previous studies have shown that wear debris originates from four main locations: articulating surfaces, modular component surfaces, surfaces of fixation, and adjuvant fixation devices. Each of these possible wear sources can initiate the cascade of failure associated with wear-induced osteolysis and lead to subsequent revision surgery. The objective of this thesis is to characterize the in …