Open Access. Powered by Scholars. Published by Universities.®
- Institution
-
- California Polytechnic State University, San Luis Obispo (61)
- Michigan Technological University (35)
- New Jersey Institute of Technology (31)
- Utah State University (30)
- Wright State University (29)
-
- Clemson University (25)
- University of Nebraska - Lincoln (19)
- University of Arkansas, Fayetteville (18)
- Al Esraa University (16)
- Missouri University of Science and Technology (16)
- Raynor Library Marquette University (16)
- Yıldız Technical University (13)
- Cleveland State University (12)
- University of South Florida (12)
- Louisiana Tech University (11)
- The University of Akron (10)
- Virginia Commonwealth University (10)
- Old Dominion University (8)
- Rowan University (8)
- Tashkent State Technical University (8)
- University of Kentucky (8)
- Boise State University (7)
- Florida Institute of Technology (7)
- Wayne State University (7)
- Louisiana State University (6)
- Purdue University (6)
- Technological University Dublin (6)
- University of Louisville (6)
- University of Mississippi (6)
- Santa Clara University (5)
- Keyword
-
- Corrosion (18)
- Department of Biomedical Engineering (17)
- Biomaterials (15)
- Biocompatibility (11)
- Magnesium (11)
-
- Microstructure (11)
- Engineering (10)
- Implants (10)
- Microfluidics (10)
- Stent (10)
- Tissue engineering (10)
- Titanium (10)
- Applied sciences (9)
- Biosensors (9)
- Biodegradable (8)
- Mechanical engineering and machinery (8)
- TJ1-1570 (8)
- Bone (7)
- Mechanical properties (7)
- Zinc (7)
- Biofilm (6)
- Biomechanics (6)
- Biomedical (6)
- Biomedical engineering (6)
- Bioreactor (6)
- Dental alloy (6)
- Department of Biomedical, Industrial & Human Factors Engineering (6)
- Nanotechnology (6)
- Prosthesis (6)
- Prosthetic (6)
- Publication Year
- Publication
-
- Theses and Dissertations (30)
- Theses (27)
- Biomedical Engineering (26)
- Master's Theses (22)
- Biomedical, Industrial & Human Factors Engineering Faculty Publications (21)
-
- Cells and Materials (19)
- Al-Esraa University College Journal for Engineering Sciences (16)
- All Dissertations (16)
- Biomedical Engineering Faculty Research and Publications (15)
- Chemical and Biochemical Engineering Faculty Research & Creative Works (14)
- Journal of Sustainable Construction Materials and Technologies (13)
- Michigan Tech Publications, Part 1 (13)
- Dissertations, Master's Theses and Master's Reports (12)
- USF Tampa Graduate Theses and Dissertations (12)
- Doctoral Dissertations (11)
- Graduate Theses and Dissertations (11)
- ETD Archive (10)
- Electronic Theses and Dissertations (10)
- Williams Honors College, Honors Research Projects (10)
- Browse all Theses and Dissertations (8)
- Honors Theses (8)
- Technical science and innovation (8)
- All Theses (7)
- Department of Agricultural and Biological Systems Engineering: Faculty Publications (7)
- All Graduate Theses and Dissertations, Spring 1920 to Summer 2023 (6)
- Dissertations (6)
- Mechanical Engineering (6)
- Materials Engineering (5)
- Mechanical and Biomedical Engineering Faculty Publications and Presentations (5)
- Articles (4)
- Publication Type
Articles 301 - 330 of 529
Full-Text Articles in Entire DC Network
The Smart Hard Hat, Darcy Fyffe, Connor Langenderfer, Charlton Johns
The Smart Hard Hat, Darcy Fyffe, Connor Langenderfer, Charlton Johns
Williams Honors College, Honors Research Projects
In a wide variety of manual labor industries, workers are often unaware that they are approaching dangerous vital thresholds until they have already overexerted themselves. According to a 2012 white paper by the Occupational Safety and Health Administration (OSHA), over 4,500 workers lose their lives, and more than 4 million are seriously injured each year. There is an immediate need to improve the safety and monitoring of manual workers to reduce the number of workplace injuries and fatalities. Millions of laborers around the globe go to work every day relying on basic safety devices, such as harnesses and steel toed …
Reducing Fretting Corrosion At The Femoral Neck To Taper Junction In Total Hip Arthroplasty, Andrea M. Carly, Nicholas S. Moyer, Abel S. Pietros
Reducing Fretting Corrosion At The Femoral Neck To Taper Junction In Total Hip Arthroplasty, Andrea M. Carly, Nicholas S. Moyer, Abel S. Pietros
Williams Honors College, Honors Research Projects
Fretting corrosion due to micromotion between the femoral head and neck of hip implants is a growing concern of surgeons and patients. Debris from corrosion can lead to severe adverse effects for patients of total hip arthroplasty and reduce the lifespan of the product. Previous studies conducted by Zimmer Biomet show a connection between higher impaction force and reduced fretting corrosion and debris. This design project explored this issue and developed a training device using a current technology, a dynamic force sensor, and data analysis software for surgeons to obtain muscle memory of a 4kN strike on the head impactor, …
Development Of Carbon Based Neural Interface For Neural Stimulation/Recording And Neurotransmitter Detection, Wenwen Yi
Wayne State University Dissertations
Electrical stimulation and recording of neural cells have been widely used in basic neuroscience studies, neural prostheses, and clinical therapies. Stable neural interfaces that effectively communicate with the nervous system via electrodes are of great significance. Recently, flexible neural interfaces that combine carbon nanotubes (CNTs) and soft polymer substrates have generated tremendous interests. CNT based microelectrode arrays (MEAs) have shown enhanced electrochemical properties compared to commonly used electrode materials such as tungsten, platinum or titanium nitride. On the other hand, the soft polymer substrate can overcome the mechanical mismatch between the traditional rigid electrodes (or silicon shank) and the soft …
Modeling Effects Of Diet On Human Gut Microbiota, Richard Thomas Agans
Modeling Effects Of Diet On Human Gut Microbiota, Richard Thomas Agans
Browse all Theses and Dissertations
The human gut microbiota is integrally involved in the metabolism of nutrients contained within the human diet. Studies into human nutrition have primarily been carried out using human and animal models. These studies are extremely important in our understanding of human nutrition, however, suffer from inherent limitations including unique microbial compositions between individuals, compliance in human studies, inability to carry out mechanistic studies, and inability to interrogate proximal regions of the gut without applying invasive techniques. In vitro gut simulator systems circumvent many of these limitations in animal and human models by allowing control of gut environmental conditions, decreasing variability …
Wireless Implantable Magnetoelastic Sensors And Actuators For Biomedical Applications, Andrew Derouin
Wireless Implantable Magnetoelastic Sensors And Actuators For Biomedical Applications, Andrew Derouin
Dissertations, Master's Theses and Master's Reports
Magnetoelastic sensors represent a low-cost wireless and battery-less method for monitoring parameters in embedded or implanted applications; however, some limitations still exist preventing their commercial implementation. Presented in this work are a variety of studies that are aimed at improving the feasibility of magnetoelastic materials for sensing and actuating applications. Magnetoelastic resonant sensors of non-standard geometries were investigated to determine if geometry could play a role on the sensitivity of the sensor response to mass loading. It was shown that a significant increase in sensitivity could be achieved by using triangular sensors rather than standard rectangular strips. A method for …
Bioactive Poly(Beta-Amino Ester) Biomaterials For Treatment Of Infection And Oxidative Stress, Andrew L. Lakes
Bioactive Poly(Beta-Amino Ester) Biomaterials For Treatment Of Infection And Oxidative Stress, Andrew L. Lakes
Theses and Dissertations--Chemical and Materials Engineering
Polymers have deep roots as drug delivery tools, and are widely used in clinical to private settings. Currently, however, numerous traditional therapies exist which may be improved through use of polymeric biomaterials. Through our work with infectious and oxidative stress disease prevention and treatment, we aimed to develop application driven, enhanced therapies utilizing new classes of polymers synthesized in-house. Applying biodegradable poly(β-amino ester) (PBAE) polymers, covalent-addition of bioactive substrates to these PBAEs avoided certain pitfalls of free-loaded and non-degradable drug delivery systems. Further, through variation of polymer ingredients and conditions, we were able to tune degradation rates, release profiles, cellular …
Synthesis And Characterization Of Antioxidant Conjugated Poly(Βeta-Amino Ester) Micro/Nanogels For The Suppression Of Oxidative Stress, Prachi Gupta
Theses and Dissertations--Chemical and Materials Engineering
Oxidative stress is a pathophysiological condition defined by an increased production of reactive oxygen species (ROS), which can result in the growth arrest of cells followed by cell disintegration or necrosis. A number of small molecule antioxidants (e.g. curcumin, quercetin and resveratrol) are capable of directly scavenging ROS, thereby short-circuiting the self-propagating oxidative stress state. However, poor solubility and rapid 1st pass metabolism results in overall low bioavailability and acts as a barrier for its use as a drug to suppress oxidative stress efficiently.
To overcome this limitation, these small molecule antioxidants were covalently conjugated into poly(β-amino ester) (PβAE) …
Effects Of Antidepressants On Human Mesenchymal Stem Cell Differentiation On Clinically Relevant Titanium Surfaces, Nancy B. Ayad
Effects Of Antidepressants On Human Mesenchymal Stem Cell Differentiation On Clinically Relevant Titanium Surfaces, Nancy B. Ayad
Theses and Dissertations
Selective Serotonin Reuptake Inhibitors (SSRIs) are the most frequently prescribed class of drugs worldwide and are implemented in the treatment of depression and other psychiatric disorders. SSRIs relieve depressive symptoms by modulating levels of the neurotransmitter serotonin in the brain. SSRIs block the function of the serotonin transporter, thereby increasing concentrations of extracellular serotonin. However, serotonin levels in the neurons of the brain only account for 5% while the remaining 95% is present outside the brain. Serotonin receptors and transporter are located on bone resident cells (mesenchymal stem cells (MSCs)), osteoblasts and osteoclasts, and serotonergic activity is believed to affect …
Investigation Of The Inherent Chemical, Structural, And Mechanical Attributes Of Bio-Engineered Composites Found In Nature: Alligator Gar’S Exoskeleton Fish Scales, Wayne Derald Hodo
Investigation Of The Inherent Chemical, Structural, And Mechanical Attributes Of Bio-Engineered Composites Found In Nature: Alligator Gar’S Exoskeleton Fish Scales, Wayne Derald Hodo
Graduate Theses and Dissertations
The U.S. Army has determined a huge cost savings of up to 51% can be accomplished by reducing the gross vehicle weight, for their personnel carrier, by 33%. To cut cost, composite materials are needed. Man-made composites can have superior material properties (high-strength, high-fracture toughness, and lightweight), but they are prone to delamination at the glued-layered interface. In contrast, fish scale is a natural composite that has the same material properties and, additionally, tend not to delaminate.
The focus of this study was to learn how nature integrates hard and soft materials at each length scale to form a layered …
When 1 + 1 > 2: Nanostructured Composites For Hard Tissue Engineering Applications, Vuk Uskoković
When 1 + 1 > 2: Nanostructured Composites For Hard Tissue Engineering Applications, Vuk Uskoković
Pharmacy Faculty Articles and Research
Multicomponent, synergistic and multifunctional nanostructures have taken over the spotlight in the realm of biomedical nanotechnologies. The most prospective materials for bone regeneration today are almost exclusively composites comprising two or more components that compensate for the shortcomings of each one of them alone. This is quite natural in view of the fact that all hard tissues in the human body, except perhaps the tooth enamel, are composite nanostructures. This review article highlights some of the most prospective breakthroughs made in this research direction, with the hard tissues in main focus being those comprising bone, tooth cementum, dentin and enamel. …
Alagebrium Inhibits Neointimal Hyperplasia And Restores Distributions Of Wall Shear Stress By Reducing Downstream Vascular Resistance In Obese And Diabetic Rats, Hongfeng Wang, Dorothee Weihrauch, Judy R. Kersten, Jeffrey M. Toth, Anthony G. Passerini, Anita Rajamani, Sonja Schrepfer, John F. Ladisa Jr.
Alagebrium Inhibits Neointimal Hyperplasia And Restores Distributions Of Wall Shear Stress By Reducing Downstream Vascular Resistance In Obese And Diabetic Rats, Hongfeng Wang, Dorothee Weihrauch, Judy R. Kersten, Jeffrey M. Toth, Anthony G. Passerini, Anita Rajamani, Sonja Schrepfer, John F. Ladisa Jr.
Biomedical Engineering Faculty Research and Publications
Mechanisms of restenosis in type 2 diabetes mellitus (T2DM) are incompletely elucidated, but advanced glycation end-products (AGEs)-induced vascular remodeling likely contributes. We tested the hypothesis that AGEs-related collagen cross-linking (ARCC) leads to increased downstream vascular resistance (DVR), and altered in-stent hemodynamics, thereby promoting neointimal hyperplasia (NH) in T2DM. We proposed that decreasing ARCC with ALT-711 (Alagebrium) would mitigate this response. Abdominal aortic stents were implanted in Zucker lean (ZL), obese (ZO), and diabetic (ZD) rats. Blood flow, vessel diameter, and wall shear stress (WSS) were calculated after 21 days, and NH was quantified. Arterial segments (aorta, carotid, iliac, femoral, arterioles) …
Analysis Of A Clinically Failed, Mechanically Intact, Reconstructive Compression Plate, Bharadwaj Cheruvu, Sunil Karmacharya, Richard T. Laughlin, Tarun Goswami
Analysis Of A Clinically Failed, Mechanically Intact, Reconstructive Compression Plate, Bharadwaj Cheruvu, Sunil Karmacharya, Richard T. Laughlin, Tarun Goswami
Biomedical, Industrial & Human Factors Engineering Faculty Publications
A reconstructive orthopedic bone plate was submitted for analysis. Traditional failure analysis methods were used to assess the mode of the plate failure. Metallographic investigation of the plate was carried out in this report. Since limited data was available in the literature and clinical data related to subject demography, date of removal as well as reasons for removal unknown, in depth analysis was not possible. However, the plate was received in in-tact condition with minor biological deposits and scratches, it is speculated that the failure of the plate may have been due to biological/clinical reasons, likely infection, rejecting the device …
Diamond Mems Biosensors: Development And Applications, Wenli Zhang
Diamond Mems Biosensors: Development And Applications, Wenli Zhang
Doctoral Dissertations
This research focuses on the development a dielectrophoresis-enhanced microfluidic impedance biosensor (DEP-e-MIB) to enable fast response, real-time, label-free, and highly sensitive sensor for bacterial detection in clinical sample. The proposed design consists of application of dielectrophoresis (DEP) across a microfluidic channel to one of the impedance spectroscopy electrodes in order to improve the existent bacterial detection limits with impedance spectroscopy. In order to realize such a design, choice of electrode material with a wide electrochemical potential window for water is very important. Conventional electrode material, such as gold, are typically insulated for the application of DEP, and they fail when …
Self-Contained Breathing Apparatus For Firefighter With A Permanent Stoma, Jason Delgadillo, Aaron Wheeler, Zachary Wishbow
Self-Contained Breathing Apparatus For Firefighter With A Permanent Stoma, Jason Delgadillo, Aaron Wheeler, Zachary Wishbow
Biomedical Engineering
The purpose of this project was to create a unique SCBA (self-contained breathing apparatus) for a firefighter named Chris Gauer. This prototype consists of a SCBA headgear connected to a polycarbonate-formed stoma mask with a medical-grade sanitary silicone hose.
Assessment Of Bore-Cone Taper Junctions In Explanted Modular Total Hip Replacements, Christine Margaret Stamer
Assessment Of Bore-Cone Taper Junctions In Explanted Modular Total Hip Replacements, Christine Margaret Stamer
All Theses
For people with chronic hip pain due to arthritis or other conditions, a total hip replacement (THR) is a common procedure used to eliminate the pain. Due to the natural variation in patient anatomy, THR prostheses are becoming increasingly more modular to allow for a more customized initial replacement and for an easier revision if needed in the future. Currently, THR prostheses routinely have modular femoral heads to provide surgeons with intraoperative flexibility. This modularity allows the surgeons to maintain the proper leg length and restore hip biomechanics for the patient and insert the components more easily and precisely. Modular …
Design Of A Simple Device For Accurate Measurement Of Human Blood Viscosity In Oxygenated And Deoxygenated Conditions, Catherine E. Oliver, Jessica Hockla, Divya Kamireddi
Design Of A Simple Device For Accurate Measurement Of Human Blood Viscosity In Oxygenated And Deoxygenated Conditions, Catherine E. Oliver, Jessica Hockla, Divya Kamireddi
Honors Scholar Theses
The purpose of this research is to design, fabricate, and test a simple device that can accurately measure the viscosity of whole blood in both an oxygenated and a deoxygenated environment. The ideal device is easy to operate, inexpensive to fabricate, and is usable outside of a laboratory setting. The microfluidic rheometer presented here was fabricated using a wet chemical etching method. Using the channel dimensions, the known viscosity of a reference fluid, and the velocity of fluid flow of the sample and a reference fluid through the microchannels the unknown viscosity of a sample fluid is calculated.
Mitochondrial Dysfunction And Loss Of Glutamate Uptake In Primary Astrocytes Exposed To Titanium Dioxide Nanoparticles, Christina L. Wilson
Mitochondrial Dysfunction And Loss Of Glutamate Uptake In Primary Astrocytes Exposed To Titanium Dioxide Nanoparticles, Christina L. Wilson
Department of Chemical and Biomolecular Engineering: Dissertations, Theses, and Student Research
The proper function of astrocytes is critical for brain health as they are the most abundant cells in the brain which monitor ion homeostasis, recycle neurotransmitters and respond to tissue damage therefore disruption in astrocyte function can result in overall detrimental effects and has been linked with neurodegenerative diseases. Titanium Dioxide (TiO2) nanoparticles are currently the second most produced engineered nanomaterial in the world with vast usage in consumer products leading to recurrent human exposure. Animal studies indicate significant nanoparticle accumulation in the brain while cellular toxicity studies demonstrate negative effects on neuronal cell viability and function. However, …
Catalytic Fast Pyrolysis Of Whole Field Pennycress Biomass, Yonas Afewerki Kidane
Catalytic Fast Pyrolysis Of Whole Field Pennycress Biomass, Yonas Afewerki Kidane
All Graduate Theses and Dissertations, Spring 1920 to Summer 2023
To satisfy the energy demand of the ever-increasing world population as well as to prevent environmental pollution arising from the use of fossil fuels, an alternate source of energy has to be developed. Biomass has the potential to provide a renewable energy source that is inexpensive and environmentally friendly. Field pennycress (Thlaspi arvense L.), previously considered as a weed, has now been found to be an ideal source of bio-fuel production. The focus of this research was to produce upgraded bio-oil by a process known as catalytic fast pyrolysis. A characterization and a temperature degradation profile study helped to …
Surface Modification Of Traditional And Bioresorbable Metallic Implant Materials For Improved Biocompatibility, Emily Kristine Walker
Surface Modification Of Traditional And Bioresorbable Metallic Implant Materials For Improved Biocompatibility, Emily Kristine Walker
Open Access Dissertations
Due to their strength, elasticity, and durability, a variety of metal alloys are commonly used in medical implants. Traditionally, corrosion-resistant metals have been preferred. These permanent materials can cause negative systemic and local tissue effects in the long-term. Permanent stenting can lead to late-stent thrombosis and in-stent restenosis. Metallic pins and screws for fracture fixation can corrode and fail, cause loss of bone mass, and contribute to inflammation and pain at the implant site, requiring reintervention. Corrodible metallic implants have the potential to prevent many of these complications by providing transient support to the affected tissue, dissolving at a rate …
Surface Modification Of Biodegradable Porous Mg Bone Scaffold Using Polycaprolactone/Bioactive Glass Composite, Mostafa Yazdimamaghani, Mehdi Razavi, Daryoosh Vashaee, Lobat Tayebi
Surface Modification Of Biodegradable Porous Mg Bone Scaffold Using Polycaprolactone/Bioactive Glass Composite, Mostafa Yazdimamaghani, Mehdi Razavi, Daryoosh Vashaee, Lobat Tayebi
Chemical and Biochemical Engineering Faculty Research & Creative Works
A reduction in the degradation rate of magnesium (Mg) and its alloys is in high demand to enable these materials to be used in orthopedic applications. For this purpose, in this paper, a biocompatible polymeric layer reinforced with a bioactive ceramic made of polycaprolactone (PCL) and bioactive glass (BG) was applied on the surface of Mg scaffolds using dip-coating technique under low vacuum. The results indicated that the PCL-BG coated Mg scaffolds exhibited noticeably enhanced bioactivity compared to the uncoated scaffold. Moreover, the mechanical integrity of the Mg scaffolds was improved using the PCL-BG coating on the surface. The stable …
Investigating The Solubility And Cytocompatibility Of Cao-Na2o-Sio2/Tio2 Bioactive Glasses, Anthony W. Wren, Aisling Coughlan, Courtney M. Smith, Sarah P. Hudson, Fathima R. Laffir, Mark R. Towler
Investigating The Solubility And Cytocompatibility Of Cao-Na2o-Sio2/Tio2 Bioactive Glasses, Anthony W. Wren, Aisling Coughlan, Courtney M. Smith, Sarah P. Hudson, Fathima R. Laffir, Mark R. Towler
Chemical and Biochemical Engineering Faculty Research & Creative Works
This study aims to investigate the solubility of a series of titanium (TiO2)-containing bioactive glasses and their subsequent effect on cell viability. Five glasses were synthesized in the composition range SiO2-Na2O-CaO with 5 mol % of increments TiO2 substituted for SiO2. Glass solubility was investigated with respect to (1) exposed surface area, (2) particle size, (3) incubation time, and (4) compositional effects. Ion release profiles showed that sodium (Na+) presented high release rates after 1 day and were unchanged between 7 and 14 days. Calcium (Ca2+) release …
Time And Temperature Dependent Surface Tension Measurements Of Responsive Protein-Based Polymer Surfactant Solutions, Hakan Celik
Time And Temperature Dependent Surface Tension Measurements Of Responsive Protein-Based Polymer Surfactant Solutions, Hakan Celik
ETD Archive
A three-armed star elastin-like polypeptide (ELP-foldon) has thermoreversible character which exhibits phase separation above a transition temperature (Tt) in physiologic salt concentrations. At lower salt concentration, the ELP-foldon behaves like a thermoresponsive surfactant, exhibiting micelle formation above its Tt. The purpose of this study is characterize the surfactant behavior of the ELP-foldon at air-liquid interface by measuring the surface tension. The surface tension is measured as a function of time for different ELP concentrations from 10 nM to 50 ℗æM and over range of temperatures from 25 to 35 ℗¿ using the axisymmetric drop shape analysis (ADSA). The ADSA is …
Frontal Cryosectioning: An Improved Protocol For Sectioning Large Areas Of Fibrous Scaffolds, Casey Grey, David G. Simpson
Frontal Cryosectioning: An Improved Protocol For Sectioning Large Areas Of Fibrous Scaffolds, Casey Grey, David G. Simpson
Biomedical Engineering Publications
Fibrous tissue engineering scaffolds, such as those produced by electrospinning, cannot achieve their clinical potential until deep cell-scaffold interactions are understood. Even the most advanced imaging techniques are limited to capturing data at depths of 100 µm due to light scatter associated with the fibers that compose these scaffolds. Conventional cross-sectional analysis provides information on relatively small volumes of space and frontal sections are difficult to generate. Current understanding of cellular penetration into fibrous scaffolds is limited predominantly to the scaffold surface. Although some information is available from cross-sections, sections vary in quality, can distort spatial scaffold properties, and offer …
Fabrication And Characterization Of A Robust, Field- Deployable, Optical Sensor Designed To Detect Particles In Oils., Navya Pandreka
Fabrication And Characterization Of A Robust, Field- Deployable, Optical Sensor Designed To Detect Particles In Oils., Navya Pandreka
Wayne State University Theses
Some types of bacteria and fungus can use iron or non-ferrous metals for their metabolic process. Sulfate-reducing bacteria can corrode pipes in the oil industry and high-end machinery. Both aerobic and anaerobic bacteria often degrade fuel quality and cause fuel system corrosion or alter the chemical properties of the fluid. This causes significant economic damage and safety concerns. Therefore, there is a need for a system to continuously monitor fuel or lubricant oil for the presence of bacteria and fungus.
The main goal of this project was to develop a sensor that can detect bacteria and other ferrous and non-ferrous …
Comparison Of Glucose, Fructose And Sucrose Amperometric And Thermal Sensors For Detection Of Carbohydrates In Living Plant Tissue, Scott Mcadoo
Legacy Theses & Dissertations (2009 - 2024)
Ecologists currently cannot test concentrations of carbohydrates in sap in vivo. Testing carbohydrates with current technology would require destructive tissue sampling. The tissue sampling involves large amounts of time and money to collect and test. Aphids are an insect that can bypass a tree’s passive immune system and feed off a phloem region for weeks. A series of enzymatic biosensors could be used to detect the concentration changes of specific carbohydrates. A calcium chelant can be added to defeat a tree’s immune system like an aphid. The detection of three carbohydrates, fructose, glucose and sucrose are involved in this study. …
Engineering Approaches For Suppressing Deleterious Host Responses To Medical Implants, Connor Mccarthy
Engineering Approaches For Suppressing Deleterious Host Responses To Medical Implants, Connor Mccarthy
Dissertations, Master's Theses and Master's Reports
Small diameter (< 6 mm) vascular grafts suffer from serious deleterious effects not encountered with their larger diameter relatives, leading to premature graft failure through restenosis. Platelet activation, inflammation, and smooth muscle cell proliferation are leading contributors to thrombosis and neointimal hyperplasia, both contributors to the progression of restenosis. It may be possible to suppress negative biological responses to vascular implants through the modification of surface properties and incorporation of drug release into blood contacting materials. In this work, bioengineering approaches are presented to improve the biocompatibility of small diameter vascular grafts.
We demonstrate a novel engineering approach for incorporating natural, decollagenized elastin matrices into PEU 1074A reinforced vascular grafts through spray-coating and electrospinning processes in a manner that retains elastin’s excellent blood contacting properties. A vascular construct with excellent mechanical and surgical handling properties demonstrating the suppression of neointimal hyperplasia is presented after 21 days in vivo.
Nitric oxide (NO) has been investigated over the past several decades due to its platelet, inflammation, and smooth muscle cell suppressing effects; and if appropriately delivered, could positively mediate the contributors to restenosis. Here, we characterize a novel macrocyclic NO …
Biocorrosion Rate And Mechanism Of Metallic Magnesium In Model Arterial Environments, Patrick Bowen
Biocorrosion Rate And Mechanism Of Metallic Magnesium In Model Arterial Environments, Patrick Bowen
Dissertations, Master's Theses and Master's Reports
A new paradigm in biomedical engineering calls for biologically active implants that are absorbed by the body over time. One popular application for this concept is in the engineering of endovascular stents that are delivered concurrently with balloon angioplasty. These devices enable the injured vessels to remain patent during healing, but are not needed for more than a few months after the procedure. Early studies of iron- and magnesium-based stents have concluded that magnesium is a potentially suitable base material for such a device; alloys can achieve acceptable mechanical properties and do not seem to harm the artery during degradation. …
Freeform Extrusion Fabrication Of Titanium Fiber Reinforced 13-93 Bioactive Glass Scaffolds, Albin Thomas
Freeform Extrusion Fabrication Of Titanium Fiber Reinforced 13-93 Bioactive Glass Scaffolds, Albin Thomas
Masters Theses
"Although implants made with bioactive glass have shown promising results for bone repair, their application in repairing load-bearing long bones is limited due to their poor mechanical properties as compared to human bones. This thesis study is on freeform extrusion fabrication of silicate based 13-93 bioactive glass scaffolds reinforced with titanium fibers. A composite paste was prepared with 13-93 bioactive glass filled with titanium fibers (~16 µm in diameter and aspect ratio of ~250) having 0.1 to 0.4 vol. % of the bioactive glass scaffold. This paste was then filled into a syringe manually, and then extruded through a nozzle …
Fabrication, Testing And Analysis Of A Fatigue Sensor For Structural Health Monitoring, Subash Gokanakonda
Fabrication, Testing And Analysis Of A Fatigue Sensor For Structural Health Monitoring, Subash Gokanakonda
Dissertations
A novel fatigue monitoring sensor (FMS) is designed, fabricated and tested for detecting and monitoring the fatigue damage and estimating the remaining life of structures and components subjected to cyclic loads. The concept is based on the characteristics of stress / strain life cycle relationship of engineering materials. Sensor consists of alternate slots and strips having different strain magnification factor with respect to the nominal strain. The sensor is designed in such a way that the strips will experience the strain which closely resemble the actual strain distribution in the notch or critical area of the component. The sensor can …
A Rubric For Electrochemical Testing Of Metallic Biomaterials, Frederick G. De La Fuente
A Rubric For Electrochemical Testing Of Metallic Biomaterials, Frederick G. De La Fuente
Master's Theses
Corrosion is a major factor for the failure of metallic medical implants. Testing a metal’s suseptability to corrosion prior to implantation is key to a successful implantation. Electrochemical processes were used in this study to evaluate the characteristics of corrosion of both AISI 316 stainless steel and titanium alloy Ti6Al4V, welded and non-welded. Linear, potentiodynamic, and cyclic polarization curves were produced by the PARC 2273 potentiostat showing the corrosion tendencies of the metals in four unique solutions 3.5% NaCl, 0.35% NaCl, phosphate buffered saline solution (PBS), and Butterfield phosphate buffered solution (BPS). The concentration of chloride ions in solutions affected …