Articles 1 - 2 of 2
Full-Text Articles in Science and Technology Studies
A Comparative Analysis Of Multichannel Data Acquisition Systems For Quality Assurance In External Beam Radiation Therapy, Iolanda Fuduli, Claudiu Porumb, Anthony Espinoza, Abdullah Aldosari, Martin Carolan, Michael Lf Lerch, Peter E. Metcalfe, Anatoly Rosenfeld, Marco Petasecca
A Comparative Analysis Of Multichannel Data Acquisition Systems For Quality Assurance In External Beam Radiation Therapy, Iolanda Fuduli, Claudiu Porumb, Anthony Espinoza, Abdullah Aldosari, Martin Carolan, Michael Lf Lerch, Peter E. Metcalfe, Anatoly Rosenfeld, Marco Petasecca
Anthony A Espinoza Mr
The paper presents a comparative study performed by the Centre of Medical Radiation Physics (CMRP) on three multichannel Data Acquisition Systems (DAQ) based on different analogue front-ends to suit a wide range of radiotherapy applications. The three front-ends are: a charge-to-frequency converter developed by INFN Torino, an electrometer and a charge-to-digital converter (both commercial devices from Texas Instruments). For the first two (named DAQ A and B), the CMRP has designed the read-out systems whilst the third one (DAQ C) comes with its own evaluation board. For the purpose of the characterization DAQ A and DAQ B have been equipped …
X-Tream: A Novel Dosimetry System For Synchrotron Microbeam Radiation Therapy, M Petasecca, A Cullen, I Fuduli, A Espinoza, C Porumb, C Stanton, A H. Aldosari, E Brauer-Krisch, H Requardt, A Bravin, V Perevertaylo, Anatoly B. Rosenfeld, M L. F Lerch
X-Tream: A Novel Dosimetry System For Synchrotron Microbeam Radiation Therapy, M Petasecca, A Cullen, I Fuduli, A Espinoza, C Porumb, C Stanton, A H. Aldosari, E Brauer-Krisch, H Requardt, A Bravin, V Perevertaylo, Anatoly B. Rosenfeld, M L. F Lerch
Anthony A Espinoza Mr
Microbeam Radiation Therapy (MRT) is a radiation treatment technique under development for inoperable brain tumors. MRT is based on the use of a synchrotron generated X-ray beam with an extremely high dose rate ( ~ 20 kGy/sec), striated into an array of X-ray micro-blades. In order to advance to clinical trials, a real-time dosimeter with excellent spatial resolution must be developed for absolute dosimetry. The design of a real-time dosimeter for such a radiation scenario represents a significant challenge due to the high photon flux and vertically striated radiation field, leading to very steep lateral dose gradients. This article analyses …