Review Of Four Novel Dosimeters Developed For Use In Radiotherapy, P Metcalfe, A Quinn, K Loo, M Lerch, M Petasecca, J Wong, N Hardcastle, M Carolan, J Mcnamara, D Cutajar, I Fuduli, A Espinoza, C Porumb, Anatoly Rosenfeld Jan 2015

Review Of Four Novel Dosimeters Developed For Use In Radiotherapy, P Metcalfe, A Quinn, K Loo, M Lerch, M Petasecca, J Wong, N Hardcastle, M Carolan, J Mcnamara, D Cutajar, I Fuduli, A Espinoza, C Porumb, Anatoly Rosenfeld

Anthony A Espinoza Mr

Centre for Medical Radiation Physics (CMRP) is a research strength at the University of Wollongong, the main research theme of this centre is to develop prototype novel radiation dosimeters. Multiple detector systems have been developed by Prof Rosenfelds’ group for various radiation detector applications. This paper focuses on four current detector systems being developed and studied at CMRP. Two silicon array detectors include the magic plate and dose magnifying glass (DMG), the primary focus of these two detectors is high spatial and temporal resolution dosimetry in intensity modulated radiation therapy (IMRT) beams. The third detector discussed is the MOSkin which …


A Two Dimensional Silicon Detectors Array For Quality Assurance In Stereotactic Radiotherapy: Magicplate-512, A Aldosari, M Petasecca, A Espinoza, M Newall, I Fuduli, C Porumb, S Alshaikh, Z Alrowaili, M Weaver, P Metcalfe, M Carolan, M. Lerch, V Perevertaylo, A Rosenfeld Jan 2015

A Two Dimensional Silicon Detectors Array For Quality Assurance In Stereotactic Radiotherapy: Magicplate-512, A Aldosari, M Petasecca, A Espinoza, M Newall, I Fuduli, C Porumb, S Alshaikh, Z Alrowaili, M Weaver, P Metcalfe, M Carolan, M. Lerch, V Perevertaylo, A Rosenfeld

Anthony A Espinoza Mr

Purpose: Silicon diode arrays are commonly implemented in radiation therapy quality assurance applications as they have a number of advantages including: real time operation (compared to the film) and high spatial resolution, large dynamic range and small size (compared to ionizing chambers). Most diode arrays have detector pitch that is too coarse for routine use in small field applications. The goal of this work is to characterize the two-dimensional monolithic silicon diode array named "MagicPlate-512" (MP512) designed for QA in stereotactic body radiation therapy (SBRT) and stereotactic radio surgery (SRS). Methods: MP512 is a silicon monolithic detector manufactured on a …


A Comparative Analysis Of Multichannel Data Acquisition Systems For Quality Assurance In External Beam Radiation Therapy, Iolanda Fuduli, Claudiu Porumb, Anthony Espinoza, Abdullah Aldosari, Martin Carolan, Michael Lf Lerch, Peter E. Metcalfe, Anatoly Rosenfeld, Marco Petasecca Jan 2015

A Comparative Analysis Of Multichannel Data Acquisition Systems For Quality Assurance In External Beam Radiation Therapy, Iolanda Fuduli, Claudiu Porumb, Anthony Espinoza, Abdullah Aldosari, Martin Carolan, Michael Lf Lerch, Peter E. Metcalfe, Anatoly Rosenfeld, Marco Petasecca

Anthony A Espinoza Mr

The paper presents a comparative study performed by the Centre of Medical Radiation Physics (CMRP) on three multichannel Data Acquisition Systems (DAQ) based on different analogue front-ends to suit a wide range of radiotherapy applications. The three front-ends are: a charge-to-frequency converter developed by INFN Torino, an electrometer and a charge-to-digital converter (both commercial devices from Texas Instruments). For the first two (named DAQ A and B), the CMRP has designed the read-out systems whilst the third one (DAQ C) comes with its own evaluation board. For the purpose of the characterization DAQ A and DAQ B have been equipped …


The Feasibility Study And Characterziation Of A Two-Dimensional Diode Array In “Magic Phantom” For High Dose Rate Brachytherapy Quality Assurance, A Espinoza, B Beeksma, M Petasecca, I Fuduli, C Porumb, D L. Cutajar, S Corde, M A. Jackson, M Lf Lerch, Anatoly B. Rosenfeld Jan 2015

The Feasibility Study And Characterziation Of A Two-Dimensional Diode Array In “Magic Phantom” For High Dose Rate Brachytherapy Quality Assurance, A Espinoza, B Beeksma, M Petasecca, I Fuduli, C Porumb, D L. Cutajar, S Corde, M A. Jackson, M Lf Lerch, Anatoly B. Rosenfeld

Anthony A Espinoza Mr

High dose rate (HDR) brachytherapy is a radiation treatment technique capable of delivering large dose rates to the tumor. Radiation is delivered using remote afterloaders to drive highly active sources (commonly 192Ir with an air KERMA strength range between 20 000 and 40 000 U, where 1 U = 1 uGy m2/h in air) through applicators directly into the patient's prescribed region of treatment. Due to the obvious ramifications of incorrect treatment while using such an active source, it is essential that there are methods for quality assurance (QA) that can directly and accurately verify the treatment plan and the …


Characterization Of An Innovative P-Type Epitaxial Diode For Dosimetry In Modern External Beam Radiotherapy, A Aldosari, A Espinoza, D Robinson, I Fuduli, C Porumb, S Alshaikh, M Carolan, M Lerch, V Perevertaylo, Anatoly Rosenfeld, M Petasecca Jan 2015

Characterization Of An Innovative P-Type Epitaxial Diode For Dosimetry In Modern External Beam Radiotherapy, A Aldosari, A Espinoza, D Robinson, I Fuduli, C Porumb, S Alshaikh, M Carolan, M Lerch, V Perevertaylo, Anatoly Rosenfeld, M Petasecca

Anthony A Espinoza Mr

Due to the ever-increasing complexity of treatment modalities in radiation therapy, there has been a greater need for detectors to perform quality assurance to ensure patients are treated correctly and safely. Modern radiation therapy techniques involve small field sizes, high dose gradients, and varying intensity of energy and rate. The ideal dosimeter for this treatment should display high spatial resolution, high linearity, accuracy, and radiation hardness. Silicon detectors have been widely used for radiotherapy measurements and have many attractive qualities as a dosimeter; weaknesses of silicon detectors are, however, decreases in sensitivity with accumulated dose. The Centre for Medical Radiation …


X-Tream: A Novel Dosimetry System For Synchrotron Microbeam Radiation Therapy, M Petasecca, A Cullen, I Fuduli, A Espinoza, C Porumb, C Stanton, A H. Aldosari, E Brauer-Krisch, H Requardt, A Bravin, V Perevertaylo, Anatoly B. Rosenfeld, M L. F Lerch Jan 2015

X-Tream: A Novel Dosimetry System For Synchrotron Microbeam Radiation Therapy, M Petasecca, A Cullen, I Fuduli, A Espinoza, C Porumb, C Stanton, A H. Aldosari, E Brauer-Krisch, H Requardt, A Bravin, V Perevertaylo, Anatoly B. Rosenfeld, M L. F Lerch

Anthony A Espinoza Mr

Microbeam Radiation Therapy (MRT) is a radiation treatment technique under development for inoperable brain tumors. MRT is based on the use of a synchrotron generated X-ray beam with an extremely high dose rate ( ~ 20 kGy/sec), striated into an array of X-ray micro-blades. In order to advance to clinical trials, a real-time dosimeter with excellent spatial resolution must be developed for absolute dosimetry. The design of a real-time dosimeter for such a radiation scenario represents a significant challenge due to the high photon flux and vertically striated radiation field, leading to very steep lateral dose gradients. This article analyses …


Multichannel Data Acquisition System Comparison For Quality Assurance In External Beam Radiation Therapy, I Fuduli, M Newall, A Espinoza, C Porumb, M Carolan, M. Lerch, P Metcalfe, A Rosenfeld, M Petasecca Jan 2015

Multichannel Data Acquisition System Comparison For Quality Assurance In External Beam Radiation Therapy, I Fuduli, M Newall, A Espinoza, C Porumb, M Carolan, M. Lerch, P Metcalfe, A Rosenfeld, M Petasecca

Anthony A Espinoza Mr

Megavoltage photon radiation therapies are widely used in modern cancer treatment. The improvement of the treatment has lead to the need of Quality Assurance (QA) devices to detect malfunctioning or human mistakes during the planning phase and treatment verification. Active electronic devices for 2D or 3D QA in external beam radiotherapy are typically based on analogue/digital mixed signal Data Acquisition Systems (DAS) which are required to have high spatial resolution, large dynamic range, high sensitivity, large numbers of channels and fast real-time capabilities. The Centre of Medical Radiation Physics (CMRP) has developed several multichannel DAS architectures based on different analogue …