Open Access. Powered by Scholars. Published by Universities.®

Science and Technology Studies Commons

Open Access. Powered by Scholars. Published by Universities.®

2015

Selected Works

Grid

Articles 1 - 5 of 5

Full-Text Articles in Science and Technology Studies

Novel Modulation And Control Strategy For Five-Level Anpc Converter With Unbalanced Dc Voltage Applied To A Single-Phase Grid Connected Pv System, Hamid R. Teymour, Danny Sutanto, Kashem M. Muttaqi, Phil Ciufo Apr 2015

Novel Modulation And Control Strategy For Five-Level Anpc Converter With Unbalanced Dc Voltage Applied To A Single-Phase Grid Connected Pv System, Hamid R. Teymour, Danny Sutanto, Kashem M. Muttaqi, Phil Ciufo

Dr Philip Ciufo

This paper proposes a new control strategy and a novel modulation technique for a grid-connected photo-voltaic (PV) system using a single-phase five-level flying capacitor (FC) based active-neutral-point-clamped (ANPC) converter. The proposed modulator can control the FC voltage to follow the requested reference value and simultaneously generate the required ac output voltage regardless of the values of the dc capacitor voltages of the converter. By implementing this method, smaller values of dc-link and flying capacitors can be used even in applications that could experience ripple or transient in the capacitors voltage. In the grid-connected single-phase five-level ANPC, where the capacitors can …


Fault Approximation Tool For Grid-Connected Inverter-Interfaced Distributed Generators, Joel Kennedy, Philip Ciufo, Ashish Agalgaonkar Apr 2015

Fault Approximation Tool For Grid-Connected Inverter-Interfaced Distributed Generators, Joel Kennedy, Philip Ciufo, Ashish Agalgaonkar

Dr Philip Ciufo

A novel fault approximation tool (FAT) is presented for use in distribution networks with a high penetration of inverter-interfaced distributed generation. The FAT does not rely on balanced operation nor an absolute reference point for voltage calculations, both of which are required for Newton-Raphson load flow calculations. Simulations show that the FAT provides an accurate representation of the transient and steady-state fault response for unbalanced faults when juxtaposed with a detailed small-signal model. The `sub-transient' response of the inverter-interfaced distributed generation is omitted to remove data considered extraneous from the perspective of distribution line protection analysis. The FAT is not …


Microgrids Of Commercial Buildings: Strategies To Manage Mode Transfer From Grid Connected To Islanded Mode, Lasantha Meegahapola, Duane A. Robinson, Ashish Agalgaonkar, Sarath Perera, Philip Ciufo Apr 2015

Microgrids Of Commercial Buildings: Strategies To Manage Mode Transfer From Grid Connected To Islanded Mode, Lasantha Meegahapola, Duane A. Robinson, Ashish Agalgaonkar, Sarath Perera, Philip Ciufo

Dr Philip Ciufo

Microgrid systems located within commercial premises are becoming increasingly popular and their dynamic behavior is still uncharted territory in modern power networks. Improved understanding in design and operation is required for the electricity utility and building services design sectors. This paper evaluates the design requirements for a commercial building microgrid system to facilitate seamless mode transition considering an actual commercial building microgrid system. A dynamic simulation model of the proposed microgrid system is established (utilizing DIgSILENT Power Factory) to aid the development of planning and operational philosophy for the practical system. An economic operational criterion is developed for the microgrid …


Balancing Energy In The Smart Grid Using Distributed Value Function (Dvf), Hassan Shirzeh, Fazel Naghdy, Philip Ciufo, Montserrat Ros Apr 2015

Balancing Energy In The Smart Grid Using Distributed Value Function (Dvf), Hassan Shirzeh, Fazel Naghdy, Philip Ciufo, Montserrat Ros

Dr Philip Ciufo

As the penetration of renewable energy resources increases in distribution networks, so does the need to manage these resources in an effective manner. Since these resources are installed to displace carbon-based generation and to provide an income stream to the resource owner, it is important that both installation objectives (as a minimum) can be met. With all of these renewable energy resources available, the opportunity also exists to assist with the energy management of this resource-rich distribution network. However, the renewable energy resources do not produce power in a deterministic manner. The available production depends on the time of day …


Point Of Common Coupling (Pcc) Voltage Control Of A Grid-Connected Solar Photovoltaic (Pv) System, Brian K. Perera, Philip Ciufo, Sarath Perera Apr 2015

Point Of Common Coupling (Pcc) Voltage Control Of A Grid-Connected Solar Photovoltaic (Pv) System, Brian K. Perera, Philip Ciufo, Sarath Perera

Dr Philip Ciufo

In future low voltage grids, with multiple inverter interfaced sources connected, voltage regulation may become a necessary task. The potential exists for inverter interfaced sources to be deployed to regulate the voltage at the point of common coupling (PCC) of each inverter interfaced sources. The PCC voltage regulation is attainable with inverter interfaced sources by dynamically controlling the amount of reactive power injected to the power distribution grid by individual systems. In the current research, a closed-loop controller is proposed to regulate the PCC voltage of a solar photovoltaic (PV) system that is connected to a single-phase power distribution feeder …