Magnetic Field Sensors For Detection Of Trapped Flux In Superconducting Radio Frequency Cavities, Ishwari Prasad Parajuli, Gianluigi Ciovati, Jean R. Delayen Jan 2021

Magnetic Field Sensors For Detection Of Trapped Flux In Superconducting Radio Frequency Cavities, Ishwari Prasad Parajuli, Gianluigi Ciovati, Jean R. Delayen

Physics Faculty Publications

Superconducting radio frequency (SRF) cavities are fundamental building blocks of modern particle accelerators. They operate at liquid helium temperatures (2–4 K) to achieve very high quality factors (1010–1011). Trapping of magnetic flux within the superconductor is a significant contribution to the residual RF losses, which limit the achievable quality factor. Suitable diagnostic tools are in high demand to understand the mechanisms of flux trapping in technical superconductors, and the fundamental components of such diagnostic tools are magnetic field sensors. We have studied the performance of commercially available Hall probes, anisotropic magnetoresistive sensors, and flux-gate magnetometers with …


Hom Damper Design For Bnl Eic 197mhz Crab Cavity, Binping Xiao, Jean R. Delayen, Subashini U. De Silva, Z. Li, R. Rimmer, S. Verdu-Andres, Qiong Wu Jan 2021

Hom Damper Design For Bnl Eic 197mhz Crab Cavity, Binping Xiao, Jean R. Delayen, Subashini U. De Silva, Z. Li, R. Rimmer, S. Verdu-Andres, Qiong Wu

Physics Faculty Publications

The interaction region (IR) crab cavity system is a special RF system to compensate the loss of luminosity due to a 25 mrad crossing angle at the interaction point (IP) for Brookhaven National Lab electron ion collider (BNL EIC). There will be six crab cavities, with four 197 MHz crab cavities and two 394 MHz crab cavities, installed on each side of the IP in the proton/ion ring, and one 394 MHz crab cavity on each side of the IP in the electron ring. Both rings share identical 394 MHz crab cavity design to minimize the cost and risk in …