Open Access. Powered by Scholars. Published by Universities.®

Biological and Chemical Physics Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 5 of 5

Full-Text Articles in Biological and Chemical Physics

Heterogeneous Rotational Diffusion Of A Fluorescent Probe In Lipid Monolayers, Christina M. Othon Aug 2014

Heterogeneous Rotational Diffusion Of A Fluorescent Probe In Lipid Monolayers, Christina M. Othon

Christina M Othon

The rotational correlation time of the lipid probe 1-palmitoyl-2-{6-[(7-nitro-2-1,3-benzoxadiazol-4-yl)amino]hexanoyl}-sn-glycero-3-phosphocholine (NBD-PC) is measured using fluorescence anisotropy for two lipid species. We measure the rotational diffusion in a monolayer of 1,2-Didecanoyl-sn-glycero-3-phosphocholine (DPPC) which displays a phase transition at room temperature from the liquid expanded to the liquid-condensed phase. The constant rotational diffusion of the probe throughout the phase transition reflects the measurement of dynamics in only the liquid-expanded phase. We contrast the dynamic changes during this phase coexistence to the continuous density increase observed in 1,2-dimyristoyl-sn-glycero-3-phosphocholine (DMPC) at room temperature. We observe a non-exponential decay of the probe diffusion consistent with heterogeneity …


A Non-Contrast Magnetic Resonance Imaging Technique To Assess Blood-Brain Barrier Permeability, Harini Pandithasekera Jun 2014

A Non-Contrast Magnetic Resonance Imaging Technique To Assess Blood-Brain Barrier Permeability, Harini Pandithasekera

Electronic Thesis and Dissertation Repository

The Blood-brain barrier (BBB) regulates the entry of compounds between the blood and the brain, thus plays an important role in brain homeostasis. Studies indicate in disease states such as Alzheimer’s the BBB integrity is compromised. The motive of this project is to investigate the sensitivity of the diffusion-weighted arterial spin labeling (DW-ASL) technique to detect water exchange. Testing the sensitivity requires a reliable method of opening the barrier at specific locations of the brain. Here, a unique technology named focused ultrasound (FUS) has been used to mimic a compromised BBB environment.

A series of experiments were conducted in a …


Enzyme Entrapment In Polyaniline Films Observed Via Florescence Anisotropy And Antiquenching, Louis R. Nemzer, Marissa Mccaffrey, Arthur J. Epstein Jan 2014

Enzyme Entrapment In Polyaniline Films Observed Via Florescence Anisotropy And Antiquenching, Louis R. Nemzer, Marissa Mccaffrey, Arthur J. Epstein

Louis R Nemzer

The facile entrapment of oxidoreductase enzymes within polyaniline polymer films by inducing hydrophobic collapse using phosphate buffered saline (PBS) has been shown to be a cost-effective method for fabricating organic biosensors. Here, we use fluorescence anisotropy measurements to verify enzyme immobilization and subsequent electron donation to the polymer matrix, both prerequisites for an effective biosensor. Specifically, we measure a three order of magnitude decrease in the ratio of the fluorescence to rotational lifetimes. In addition, the observed fluorescence antiquenching supports the previously proposed model that the polymer chain assumes a severely coiled conformation when exposed to PBS. These results help …


An Unexpected Particle Oscillation For Electrophoresis In Viscoelastic Fluids Through A Microchannel Constriction, Xinyu Lu, Saurin Patel, Meng Zhang, Sang Woo Joo, Shizhi Qian, Amod Ogale, Xiangchun Xuan Jan 2014

An Unexpected Particle Oscillation For Electrophoresis In Viscoelastic Fluids Through A Microchannel Constriction, Xinyu Lu, Saurin Patel, Meng Zhang, Sang Woo Joo, Shizhi Qian, Amod Ogale, Xiangchun Xuan

Mechanical & Aerospace Engineering Faculty Publications

Electrophoresis plays an important role in many applications, which, however, has so far been extensively studied in Newtonian fluids only. This work presents the first experimental investigation of particle electrophoresis in viscoelastic polyethylene oxide (PEO) solutions through a microchannel constriction under pure DC electric fields. An oscillatory particle motion is observed in the constriction region, which is distinctly different from the particle behavior in a polymer-free Newtonian fluid. This stream-wise particle oscillation continues until a sufficient number of particles form a chain to pass through the constriction completely. It is speculated that such an unexpected particle oscillating phenomenon is a …


Microfluidic Electrical Sorting Of Particles Based On Shape In A Spiral Microchannel, John Dubose, Xinyu Lu, Saurin Patel, Shizhi Qian, Sang Woo Joo Jan 2014

Microfluidic Electrical Sorting Of Particles Based On Shape In A Spiral Microchannel, John Dubose, Xinyu Lu, Saurin Patel, Shizhi Qian, Sang Woo Joo

Mechanical & Aerospace Engineering Faculty Publications

Shape is an intrinsic marker of cell cycle, an important factor for identifying a bioparticle, and also a useful indicator of cell state for disease diagnostics. Therefore, shape can be a specific marker in label-free particle and cell separation for various chemical and biological applications. We demonstrate in this work a continuous-flow electrical sorting of spherical and peanut-shaped particles of similar volumes in an asymmetric double-spiral microchannel. It exploits curvature-induced dielectrophoresis to focus particles to a tight stream in the first spiral without any sheath flow and subsequently displace them to shape-dependent flow paths in the second spiral without any …