Open Access. Powered by Scholars. Published by Universities.®
- Discipline
- Publication
Articles 1 - 5 of 5
Full-Text Articles in Physics
Broadband Acoustic Measurement Of The Agar-Based Tissue Mimicking Material – A Longitudinal Study, Adela Rabell-Montiel, Jacinta Browne, Stephen Pye, Tom Anderson, Carmel Moran
Broadband Acoustic Measurement Of The Agar-Based Tissue Mimicking Material – A Longitudinal Study, Adela Rabell-Montiel, Jacinta Browne, Stephen Pye, Tom Anderson, Carmel Moran
Articles
Commercially available ultrasound quality assurance test phantoms rely upon the long-term acoustic stability of tissue-mimicking-materials (TMMs). The measurement of the acoustic properties can be technically challenging and it is important to ensure its stability. The standard technique is to film-wrap samples of TMM and to measure the acoustic properties in a water bath. In this study, a modified technique is proposed whereby the samples of TMM are measured in a preserving fluid that is intended to maintain their characteristics. The acoustic properties were evaluated using a broadband pulse-echo substitution technique over the frequency range of 4.5 – 50 MHz at …
Broadband Acoustic Measurement Of The Agar-Based Tissue Mimicking Material: A Longitudinal Study, A. Rabell-Montiel, Jacinta Browne, S. D. Pye, T. A. Anderson, C. Moran
Broadband Acoustic Measurement Of The Agar-Based Tissue Mimicking Material: A Longitudinal Study, A. Rabell-Montiel, Jacinta Browne, S. D. Pye, T. A. Anderson, C. Moran
Articles
Commercially available ultrasound quality assurance test phantoms rely on the long-term acoustic stability of the tissue-mimicking-material (TMM). Measurement of the acoustic properties of the TMM can be technically challenging, and it is important to ensure its stability. The standard technique is to film-wrap samples of TMM and to measure the acoustic properties in a water bath. In this study, a modified technique was proposed whereby the samples of TMM are measured in a preserving fluid that is intended to maintain their characteristics. The acoustic properties were evaluated using a broadband pulse-echo substitution technique over the frequency range 4.5–50 MHz at …
Broadband Acoustic Measurement Of The Agar-Based Tissue Mimicking Material: A Longitudinal Study, A. Rabell-Montiel, Jacinta Browne, S. D. Pyke, T. A. Anderson, C. M. Moran
Broadband Acoustic Measurement Of The Agar-Based Tissue Mimicking Material: A Longitudinal Study, A. Rabell-Montiel, Jacinta Browne, S. D. Pyke, T. A. Anderson, C. M. Moran
Articles
Commercially available ultrasound quality assurance test phantoms rely on the long-term acoustic stability of the tissue-mimicking-material (TMM). Measurement of the acoustic properties of the TMM can be technically challenging, and it is important to ensure its stability. The standard technique is to film-wrap samples of TMM and to measure the acoustic properties in a water bath. In this study, a modified technique was proposed whereby the samples of TMM are measured in a preserving fluid that is intended to maintain their characteristics. The acoustic properties were evaluated using a broadband pulse-echo substitution technique over the frequency range 4.5-50 MHz at …
Dielectric Analysis Of Aqueous Poly(L-Glutamic Acid) And Poly-L-(Glutamic Acid4, Tyrosine1) Solutions At High Frequencies From Capacitance Measurements, Jorge Monreal, Tatiana Eggers, Manh-Huong Phan
Dielectric Analysis Of Aqueous Poly(L-Glutamic Acid) And Poly-L-(Glutamic Acid4, Tyrosine1) Solutions At High Frequencies From Capacitance Measurements, Jorge Monreal, Tatiana Eggers, Manh-Huong Phan
Physics Faculty Publications
A new parallel-plate capacitor fixture has been designed and successfully used to measure dielectric loss of polyelectrolyte solutions with volumes as low as droplets of 13–26 μL. It is particularly useful when studying polypeptides that are either high-cost or can be synthesized only in limited quantities. The ease with which the fixture can be used to obtain preliminary dielectric loss data yields savings in time and cost. In this study capacitance measurements were performed in a wide range of frequencies between 1 and 800 MHz using an Agilent 4191RF Impedance Analyzer. Accuracy of measurements was carefully examined through a comparison …
Novel Tissue Mimicking Materials For High Frequency Breast Ultrasound Phantoms, Louise Cannon, Andrew Fagan, Jacinta Browne
Novel Tissue Mimicking Materials For High Frequency Breast Ultrasound Phantoms, Louise Cannon, Andrew Fagan, Jacinta Browne
Articles
The development and acoustical characterisation of a range of novel agar-based tissue mimicking material (TMMs) for use in clinically relevant, quality assurance (QA) and anthropomorphic breast phantoms are presented. The novel agar-based TMMs described in this study are based on a comprehensive, systematic variation of the ingredients in the International Electrotechnical Commission (IEC) TMM. A novel, solid fat-mimicking material was also developed and acoustically characterised. Acoustical characterisation was carried out using an in-house scanning acoustic macroscope at low (7.5 MHz) and high frequencies (20 MHz), using the pulse-echo insertion technique. The speeds of sound range from 1490 to 1570 m. …