Open Access. Powered by Scholars. Published by Universities.®

Physics Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 3 of 3

Full-Text Articles in Physics

Modeling Of The Surface Plasmon Resonance (Spr) Effect For A Metal-Semiconductor (M-S) Junction At Elevated Temperatures, Erik De Jesus Sanchez Nov 1993

Modeling Of The Surface Plasmon Resonance (Spr) Effect For A Metal-Semiconductor (M-S) Junction At Elevated Temperatures, Erik De Jesus Sanchez

Dissertations and Theses

The effect of temperature increase on the optical excitation of Surface Plasmon Resonance (SPR) at an Ag-Si metal-semiconductor (M-S) junction at a wavelength of 1 . 1 52 pm is investigated theoretically using computer modeling in Fortran. In order to accurately quantify the SPR, the temperature dependent optical constants for Ag and Si are obtained theoretically or semiempirically , using a Drude model for Ag and previous experimentally determined equations for Si (the behavior of the optical constants for crystalline Si and doped Si are found to have very little deviation between each other for our case). An improvement in …


Comparison Of Ion Adsorption To Phophatidylcholine/Phosphatidylserine And Sarcoplasmic Reticulum Membranes, Martin Mense Jul 1993

Comparison Of Ion Adsorption To Phophatidylcholine/Phosphatidylserine And Sarcoplasmic Reticulum Membranes, Martin Mense

Dissertations and Theses

Artificial lipid membranes have been used in biophysical studies as well defined models of biological membranes. In the present work we studied adsorption of ions to artificial lipid membranes, composed of phosphatidylcholine (PC) and phosphatidylserine (PS), and to biological membrane from sarcoplasmic reticulum (SR). The studies of ion adsorption and electrokinetic characterization of membranes were done by means of microelectrophoresis of PC/PS liposomes and SR vesicles. The ions of interest were positively charged potassium (K), calcium (Ca), tetraphenylarsonium (TPAs), tetraphenylphosphonium (TPP) and negatively charged pentachlorophenol (PCP).

Electrophoretic mobility of PC/PS liposomes and SR vesicles has been measured as a function …


A Retarding-Potential Analyzer For Measuring Energy Distributions In Electron Beams, Li Zhou Jul 1993

A Retarding-Potential Analyzer For Measuring Energy Distributions In Electron Beams, Li Zhou

Dissertations and Theses

An energy analyzer for electron beams, based on a retarding-potential method, has been studied both experimentally and theoretically. In this method a potential energy barrier at right-angles to the beam acts as a high-pass energy filter allowing electrons having energies greater than the barrier height to pass through while turning back electrons of lower energy. The potential barrier in the present study was created by applying a negative potential to an electrode consisting of a 600/inch hexagonal copper mesh or an electrode having a pair of single apertures in series (compound aperture). Two different compound apertures, of diameters 0.4 mm …