Open Access. Powered by Scholars. Published by Universities.®

Physics Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 3 of 3

Full-Text Articles in Physics

Electro-Optical Effect Of 4-N-Alkyl-Sulfanyl-4' Isothiocyanate-Biphenyl Liquid Crystal Homologous Series Under Terahertz Frequency: A Theoretical Approach, Yogesh Kumar, Narinder Kumar Dec 2023

Electro-Optical Effect Of 4-N-Alkyl-Sulfanyl-4' Isothiocyanate-Biphenyl Liquid Crystal Homologous Series Under Terahertz Frequency: A Theoretical Approach, Yogesh Kumar, Narinder Kumar

Makara Journal of Science

This work presented the electro-optical effect of the homologous series 4-n-alkyl-sulfanyl-4'-isothiocyanate-biphenyl (N1SC13H8-SH2n+1Cn) under an electric field with terahertz (THz) frequency. The increase in alkyl sulfanyl chain length reduces the birefringence but increases the order parameter in THz frequency. An inverse relationship exists between the birefringence and order parameter. Meanwhile, the increase in alkyl sulfanyl chain length increases the refractive index with an even–odd effect. Birefringence, refractive index, order parameter, and director angle show an even–odd effect in the THz frequency range. The calculation is performed between 1 and 1,200 THz frequency. The isothiocyanate stretching corresponding to …


Application Of Photoacoustic Imaging For Pneumonia Detection, Caesarany Maqfiroh, Rini Widyaningrum, Ahmad Mujtahid Anas, Mitrayana Mitrayana Jun 2023

Application Of Photoacoustic Imaging For Pneumonia Detection, Caesarany Maqfiroh, Rini Widyaningrum, Ahmad Mujtahid Anas, Mitrayana Mitrayana

Makara Journal of Science

We used photoacoustic imaging (PAI) to visualize and compare acoustic intensity levels in pneumonia-affected and healthy chicken lungs. After histological confirmation of pneumonia, the samples were scanned and subjected to a 532-nm diode laser in a photoacoustic imaging system. The acoustic intensity level of pneumonia-affected tissue was examined and compared with that of healthy lung samples. The optimum laser frequency and duty cycle for imaging the samples were 17 kHz and 30%, respectively. The acoustic intensity levels of pneumonia-affected tissue and healthy lungs were −82.5 ± 1.8 dB and −79.9 ± 1.3 dB, respectively. We found that a simple PAI …


Carbon Dioxide-Induced Corrosion Of Aisi 4140 Steel In Acidified Artificial Geothermal Brine, Anawati Anawati, Rayhan Izzat, Riene Kaelamanda Pragitta, Rafli Ihsan Hernandi Mar 2023

Carbon Dioxide-Induced Corrosion Of Aisi 4140 Steel In Acidified Artificial Geothermal Brine, Anawati Anawati, Rayhan Izzat, Riene Kaelamanda Pragitta, Rafli Ihsan Hernandi

Makara Journal of Science

Carbon dioxide (CO2)-induced corrosion often occurs in the structural materials of geothermal industry. The presence of CO2 influences the formation of various corrosion products. This research investigates the effect of dissolved CO2 in acidic brines on the corrosion behavior of AISI 4140 steel at atmospheric pressure. The brines were the standard brine, Ca-free brine, and high-salinity brine. The corrosion behavior was studied using electrochemical and immersion tests. A cyclic polarization test showed that the corrosion rate was higher in dissolved CO2 brine than in non-CO2 brine, and an immersion test demonstrated a similar result. …